Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ATM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The ablation of graphitic materials in the sublimation regime.

A large variety of graphitic materials have been tested in an arc heated air stream at a surface pressure of 4.3 atm and a nominal surface temperature of 3925 K. Included were commercial and developmental grades of artificial graphites, both two and three dimensional carbon-carbon composites, composites seeded with refractory compounds, and several special materials such as pyrolytic graphite, mesophase graphite, glassy carbon, and natural graphite. ATJ graphite was used as a control material. Except for the seeded materials which had poor performance, the mass loss rate for all the man-made graphitic materials fell within the range of 17 per cent less to 30 per cent more than the rate for ATJ. Thus it is concluded that wide variations in constituents, processing, fabrication and structure have relatively little effect on the ablation performance of graphitic materials, at least under the conditions of the present tests. Particulate mass loss was observed for all the materials tested and is the dominant mechanism for mass removal at the present test conditions. It is suggested that this mechanism results from physical failure, primarily by compressive thermal stress.

Lundell, J. H.↗

Pressure effect on the sensitivity of quartz Bourdon tube gauges.

The sensitivity change for a commercial fused quartz Bourdon tube precision pressure gauge, due to a change in absolute pressure level, has been analytically computed and experimentally confirmed. The computed differential pressure error is 2.5% of full scale at a 100 atm absolute pressure level. The experimental method compared the fused quartz Bourdon tube gauge digital output to the results obtained from a nitrogen gas pressure system which had a high pressure, well-type mercury manometer as the differential pressure reference.

Szaniszlo, A. J.↗

Intensity and half width measurements of the /00 2 - 00 0/ band of N2O.

Measurements of the intensities and half widths of the lines of the (00 2 - 00 0) band of N2O have been made with a spectral resolution better than 0.06/cm. The band intensity has been determined to be 1.29/sq cm per atm at 296 K. The half widths have been measured for both N2 and self broadening.

Margolis, J. S.↗

Line shape parameters for HCl and HF in a CO2 atmosphere.

Results of high-resolution (0.1 cm/cm) on several CO2-broadened lines in the fundamentals of HCl35 and HCl37. Line intensities, half-widths, and shapes were determined at room temperature. Half-widths in HCl-CO2 collisions were computed for several temperatures, employing Anderson's (1949) theory. The measured shapes of HCl lines broadened by CO2 are described by a semiempirical super-Lorentzian shape. The curve-of-growth for this line shape is derived in terms of a function similar to the Ladenburgh-Reiche function. Absorption between R(0) and P(1) is affected by the appearance of several pressure-induced Q-branch lines, at the pressures from 1 to 10 atm used in the present study.

Varanasi, P.↗

Silica reinforcement and char reactions in the Apollo heat shield.

Reactions of the silica reinforcement fiber and ablation char of the Apollo heat shield have been investigated by laboratory tests in an arc image furnace (at temperature levels up to 5000 R, pressures up to 0.7 atm, and heat flux similar to reentry) and by an actual reentry test. Microchemical analyses and X-ray diffraction studies have been made to determine the presence of SiC formation in the char. Experimental data and analytical predictions of thermal and density profiles have been compared for the ablation of virgin heat shield and precharred materials to determine the effects of SiC formation on ablation performance. In all analyses, general agreement was found between chemical composition and the thermal predictions for laboratory tests and reentry materials. In all ablated materials, SiC was formed in the front surface of the char. The highest SiC content found was 58% by weight and found in a high-pressure environment. The SiC formed was found to act as a heat sink in the ablation process and can lower the front surface temperature by 300 R.

Cagliostro, D. E.↗

Auto-ignition of hydrocarbons behind reflected shock waves.

The paper reports on the study of auto-ignition of hydrocarbon-oxygen mixtures behind reflected shock waves. Because of their bearing on the problem of knock in internal combustion engines, n-heptane and iso-octane were chosen as the combustible species. Their stoichiometric mixtures with oxygen had to be diluted with 70% argon to reduce the influence of the boundary layer. Photographic records demonstrated the existence of two different modes of ignition, as has been previously established for the hydrogen-oxygen system. The pressure-temperature limits between these regions of mild and strong ignition were determined. From the same experimental tests, induction time data were obtained over the pressure range of 1-4 atm and the temperature interval of 1200-1700 K.

Vermeer, D. J.↗

The composition of the Martian atmosphere - Minor constituents.

The Mariner 6 and 7 infrared spectrometers provided data which, in principle, determine upper limits on the possible atmospheric abundance of every gaseous substance that was undetected but which has recognized absorptions in the accessible spectral region, 1.9 to 14.4 microns. Through supporting laboratory determinations of curves of growth under pressure-broadening conditions appropriate to Mars, upper limits can be specified (expressed first in cm-atm, STP, for a vertical column and then in parts per million) for NO2, NH3, C3O2, SO2, OCS, NO, O3, CH4, N2O, HCL, HBr, and H2S. In addition, considerations of band contours, moments of inertia, and experimental absorption coefficients make it possible to place useful upper limits on 27 additional substances that were not detected and for which curves of growth have not been measured.

Horn, D.↗

The physical properties of the Jovian atmosphere inferred from eclipses of the Galilean satellites. II - 1971 apparition.

Further simultaneous two-color photoelectric photometry of Ganymede was carried out at blue (4500 A) and yellow (5790 A) wavelengths during its eclipse by Jupiter on Mar. 10, 1971. In both colors, the shape of the ingress light curve was again reliably determined for extinctions up to 9 mag. Neither curve showed any evidence of a refraction tail. The observations have been interpreted in terms of the local optical transmission properties of the Jovian atmosphere. At gas number densities of about 5 x 10 to the 18th power per cu cm the maximum photon scattering mean free path at visual wavelengths was 47 km atm. Evidence indicates that neither a simple reflecting-layer model or a semiinfinite homogeneous scattering model provides an adequate physical description of the atmosphere.

Price, M. J.↗

Development of RF plasma simulations of in-reactor tests of small models of the nuclear light bulb fuel region

Experiments were conducted to develop test configurations and technology necessary to simulate the thermal environment and fuel region expected to exist in in-reactor tests of small models of nuclear light bulb configurations. Particular emphasis was directed at rf plasma tests of approximately full-scale models of an in-reactor cell suitable for tests in Los Alamos Scientific Laboratory's Nuclear Furnace. The in-reactor tests will involve vortex-stabilized fissioning uranium plasmas of approximately 200-kW power, 500-atm pressure and equivalent black-body radiating temperatures between 3220 and 3510 K.

Roman, W. C.↗

Spectral absorption coefficients of argon and silicon and spectral reflectivity of aluminum

A theoretical investigation was conducted to estimate the spectral properties of argon as a function of pressure, temperature, and wave number. The spectral characteristics of the argon buffer gas exert a strong influence on radiative energy transfer in the in-reactor test configuration of the nuclear light bulb engine. An existing computer program was modified and used to calculate the spectral absorption coefficients of argon at total pressures of 50, 100, 250, 500, 750 and 1000 atm in the temperature interval between 1000 and 30,000 K. At each pressure and temperature, spectral properties were calculated for forty-seven wave numbers in the interval between 1000 and 1,000,000 cm/1. Estimates of the spectral absorption coefficients of silicon were made as part of an evaluation of silicon vapor as a possible buffer-gas seeding agent for the reference nuclear light bulb engine. Existing cross-section data were used to calculate the spectral characteristics of silicon at twenty-four temperatures in the interval between 2000 and 10,000 K.

Krascella, N. L.↗

Tests of a mixed compression axisymmetric inlet with large transonic mass flow at Mach numbers 0.6 to 2.65

A 38.8-cm (15.28-in.) capture diameter model of a mixed-compression axisymmetric inlet system with a translating cowl was designed and tested. The internal contours, designed for Mach number 2.65, provided a throat area of 59 percent of the capture area when the cowl was retracted for transonic operation. Other model features included a boundary-layer removal system, vortex generators, an engine airflow bypass system, cowl support struts, and rotating rakes at the engine face. All tunnel testing was conducted at a tunnel total pressure of about 1 atm (a unit Reynolds number of about 8.53 million/m at Mach number 2.65) at angles of attack from 0 deg to 4 deg. Results for the following were obtained: total-pressure recovery and distortion at the engine face as a function of bleed mass-flow ratio, the effect of bleed and vortex generator configurations on pressure recovery and distortion, inlet tolerance to unstart due to changes in angle of attack or Mach number, surface pressure distributions, boundary-layer profiles, and transonic additive drag. At Mach number 2.65 and with the best bleed configurations, maximum total pressure recovery at the engine face ranged from 91 to 94.5 percent with bleed mass-flow ratios from 4 to 9 percent, respectively, and total-pressure distortion was less than 10 percent. At off-design supersonic Mach numbers above 1.70, maximum total-pressure recoveries and corresponding bleed mass flows were about the same as at Mach number 2.65, with about 10 to 15 percent distortion. In the transonic Mach number range, total pressure recovery was high (above 96 percent) and distortion was low (less than 15 percent) only when the inlet mass-flow ration was reduced 0.02 to 0.06 from the maximum theoretical value (0.590 at Mach number 1.0).

Smeltzer, D. B.↗

Comparison of primary zone combustor liner wall temperatures with calculated predictions

Calculated liner temperatures based on a steady-state radiative and convective heat balance at the liner wall were compared with experimental values. Calculated liner temperatures were approximately 8 percent higher than experimental values. A radiometer was used to experimentally determine values of flame temperature and flame emissivity. Film cooling effectiveness was calculated from an empirical turbulent mixing expression assuming a turbulent mixing level of 2 percent. Liner wall temperatures were measured in a rectangular combustor segment 6 by 12 in. and tested at pressures up to 26.7 atm and inlet temperatures up to 922 K.

Norgren, C. T.↗

Preliminary study of a wall stabilized constructed arc

An iterative, implicit, finite-difference numerical technique is described which is suitable for obtaining solutions to the governing equations for a gas flowing in an axially symmetric constricted-arc heater. The method is shown to provide adequate solutions for three cases of simple pipe flows found in the literature, and for flow in a constricted-arc heater by direct comparison with experimental data. The comparison with arc-heater data includes static pressure, arc voltage, and wall heat flux, all as a function of axial location, and a radial temperature profile at one axial station. The arc-heater data were taken with air as the test gas at a heater inlet pressure approximately 0.40 atm and two flow rates of 2.2 and 4.8 g/sec. The arc currents investigated were between 377 and 584 amperes.

Graves, R. A.↗

Evaluation of new plastic compression (Ziegler) type of seals for long life planetary batteries

A program was initiated to develop improved types of terminal seals for aerospace Ni-Cd batteries. The approach used has not involved attempts, such as employed elsewhere, to improve the ceramic-to-metal seal that is now extensively employed for this application. Rather the approach has been directed toward the development and evaluation of new types of seals. Of prime interest in this initial investigation has been the Ziegler type of compression seal and in particular the injection molded version developed by the Bell Telephone Laboratories (BTL). A number of these units were designed, fabricated, and evaluated on an accelerated life test under a simulated battery environment. Results have shown that there are no major problems involved in scaling up the BTL small-size (5-amp) seal to a larger size (up to 50-amp) seal suitable for most JPL flight batteries. Five out of five such seals successfully completed over 10 months of continuous thermal cycling without developing any leaks greater than 1.8 x to 10 to the minus 9th power atm-cc-He/s.

Frank, H. A.↗

Effect of premixing on nitric oxide formation

Emissions from a simple 10-cm (4-in.) diameter tube combustor burning a premixed, gaseous propane/air mixture were measured. Inlet conditions included a temperature of 590 K (600 F), pressure of 5.5 atm, and reference velocity of 23 m/s (75 ft/s) for a range of equivalence ratios from the lean limit to slightly richer than stoichiometric. A nitric oxide emission index of 1 g NO2/kg fuel was measured for an equivalence ratio of 0.57.

Anderson, D. N.↗

Cavity temperature and flow characteristics in a gas-core test reactor

A test reactor concept for conducting basic studies on a fissioning uranium plasma and for testing various gas-core reactor concepts is analyzed. The test reactor consists of a conventional fuel-element region surrounding a 61-cm-(2-ft-) diameter cavity region which contains the plasma experiment. The fuel elements provide the neutron flux for the cavity region. The design operating conditions include 60-MW reactor power, 2.7-MW cavity power, 200-atm cavity pressure, and an average uranium plasma temperature of 15,000 K. The analytical results are given for cavity radiant heat transfer, hydrogen transpiration cooling, and uranium wire or powder injection.

Putre, H. A.↗

Effect of fuel vapor concentrations on combustor emissions and performance

Effects of fuel vaporization on the exhaust emission levels of oxides of nitrogen, carbon monoxide, total hydrocarbons, and smoke number were obtained in an experimental turbojet combustor segment. Two different fuel injectors were used in which liquid ASTM A-1 jet fuel and vapor propane fuel were independently controlled to simulate varying degrees of vaporization. Tests were conducted over a range of inlet-air temperatures from 478 to 700 K, pressures from 4 to 20 atm, and combustor reference velocities from 15.3 to 27.4 m/sec. Converting from liquid to complete vapor fuel resulted in oxides of nitrogen reductions of as much as 22 percent and smoke number reductions up to 51 percent. Supplement data are also presented on flame emissivity, flame temperature, and primary-zone liner wall temperatures.

Norgren, C. T.↗

Apparatus and method for generating large mass flow of high temperature air at hypersonic speeds

A description is given of tests performed in the Mach number 8 to 10 regime to generate high temperature air at hypersonic speeds. The test flow was obtained by pressuring a ceramic lined storage tank with air to a pressure of about 100 to 200 atm. The air is heated to temperatures of 7,000 R to 8,000 R prior to introduction into the tank by passing air through an electric arc heater. The air cools to 5,500 R to 6,000 R while in the tank and then it is rapidly released through a Mach number 8 to 10 nozzle. Cold air or hot driver gas under pressure is injected simultaneously with the release of pressurized hot air and regulated to enter the tank at the same rate the hot air is leaving. This holds pressure in the tank constant during the test. Alternatively, the driver gas is introduced into the tank prior to the discharge of the hot air to increase the pressure in the tank and permit tests at higher pressures than can be handled by the arc heater.

Boatright, W. B.↗