Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ATLAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Keck Infrared Transient Survey. I. Survey Description and Data Release 1

Abstract We present the Keck Infrared Transient Survey, a NASA Key Strategic Mission Support program to obtain near-infrared (NIR) spectra of astrophysical transients of all types, and its first data release, consisting of 105 NIR spectra of 50 transients. Such a data set is essential as we enter a new era of IR astronomy with the James Webb Space Telescope (JWST) and the upcoming Nancy Grace Roman Space Telescope (Roman). NIR spectral templates will be essential to search JWST images for stellar explosions of the first stars and to plan an effective Roman SN Ia cosmology survey, both key science objectives for mission success. Between 2022 February and 2023 July, we systematically obtained 274 NIR spectra of 146 astronomical transients, representing a significant increase in the number of available NIR spectra in the literature. Here, we describe the first release of data from the 2022A semester. We systematically observed three samples: a flux-limited sample that includes all transients <17 mag in a red optical band (usually ZTF r or ATLAS o bands); a volume-limited sample including all transients within redshift z < 0.01 ( D ≈ 50 Mpc); and an SN Ia sample targeting objects at phases and light-curve parameters that had scant existing NIR data in the literature. The flux-limited sample is 39% complete (60% excluding SNe Ia), while the volume-limited sample is 54% complete and is 79% complete to z = 0.005. Transient classes observed include common Type Ia and core-collapse supernovae, tidal disruption events, luminous red novae, and the newly categorized hydrogen-free/helium-poor interacting Type Icn supernovae. We describe our observing procedures and data reduction using PypeIt , which requires minimal human interaction to ensure reproducibility.

Tinyanont, S. (ORCID:0000000214814676)↗

Understanding PDF uncertainty in W boson mass measurements*

Abstract We study the dependence of the transverse mass distribution of charged leptons and the missing energy on parton distributions (PDFs) adapted to W boson mass measurements at the CDF and ATLAS experiments. We compare the shape variations of the distribution induced by different PDFs and find that the spread of predictions from different PDF sets can be significantly larger than the PDF uncertainty predicted by a specific PDF set. We suggest analyzing the experimental data using up-to-date PDFs to gain a better understanding of the PDF uncertainties in W boson mass measurements. We also perform a series of Lagrange multiplier scans to identify the constraints on the transverse mass distribution imposed by individual data sets in the CT18 global analysis. In the case of the CDF measurement, the distribution is mostly sensitive to d -quark PDFs in the intermediate x region, which are largely constrained by DIS and Drell-Yan data on deuteron targets and Tevatron lepton charge asymmetry data.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating Diverse HEP Workflows on Heterogeneous Architectures

We evaluate key patterns and estimate throughput bounds of simulated transformation of conventional high energy physics (HEP) data processing workflows to heterogeneous equivalents. The simulation parameter space includes the number of offloaded tasks, CPU/accelerator ratios of intra-task computations, offload latencies, and run time efficiency of offloaded computations. The simulation is performed for a diverse set of state-of-the-art event reconstruction scenarios from ATLAS, LHCb and CMS - the frontier HEP experiments of the Large Hadron Collider project.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{sup 58}Ni({sup 3}He,t){sup 58}Cu*({gamma}) Measurements with GODDESS to Constrain the Astrophysical Rate of {sup 57}Ni(p,{gamma}){sup 58}Cu

The observation of γ rays from the decay of 44Ti in the remnants of core-collapse supernovae (CCSNe) provides crucial information regarding the nucleosynthesis occurring in these events, as 44Ti production is sensitive to CCSNe conditions. The final abundance of 44Ti is also sensitive to specific nuclear input parameters, one of which is the 57Ni(p,γ) 58Cu reaction rate. A precise rate for 57Ni(p,γ) 58Cu is thus critical if 44Ti production is to be an effective probe into CCSNe. To experimentally constrain the 57Ni(p,γ) 58Cu rate, the structure properties of 58Cu were measured via the 58Ni(3He,t)58Cu*(γ) reaction using GODDESS (GRETINA ORRUBA Dual Detectors for Experimental Structure Studies) at Argonne National Laboratory’s ATLAS facility. Details of the experiment, ongoing analysis, and plans are presented.

Carmichael, S. R.↗

Accelerating LHC event generation with simplified pilot runs and fast PDFs

High-precision calculations are an indispensable ingredient for the success of the LHC physics programme, yet their poor computing efficiency has been a growing cause for concern, threatening to become a paralysing bottleneck in the coming years. We present solutions to eliminate the apprehension by focussing on two major components of generalpurpose Monte Carlo event generators: the evaluation of parton distribution functions, and the generation of perturbative matrix elements. We show that for the cost-driving event samples employed by the ATLAS experiment to model omnipresent, irreducible Standard Model backgrounds, such as weak boson or top-quark pair production in association with jets, these computational components dominate the overall run time by up to 80 %. We demonstrate that a reduction of the computing footprint of LHAPDF and SHERPA by factors of around 40 can be achieved for multi-leg NLO event generation.

Bothmann, Enrico [Gottingen U.]↗

Experimental study of different silicon sensor options for the upgrade of the CMS Outer Tracker

During the high-luminosity phase of the LHC (HL-LHC), planned to start in 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to 7.5×10 34 cm –2 s –1 . A total integrated luminosity of 3000 or even 4000 fb –1 is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC,with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the new tracking system will be exposed to a significantly higher radiation than the current tracker, requiring new radiation-hard sensors. CMS initiated an extensive irradiation and measurement campaign starting in 2009 to systematically compare the properties of different silicon materials and design choices for the Outer Tracker sensors. Several test structures and sensors were designed and implemented on 18 different combinations of wafer materials, thicknesses, and production technologies. The devices were electrically characterized before and after irradiation with neutrons,and with protons of different energies, with fluences corresponding to those expected at different radii of the CMS Outer Tracker after 3000 fb –1 . The tests performed include studies with β sources, lasers, and beam scans. This paper compares the performance of different options for the HL-LHC silicon sensors with a focus on silicon bulk material and thickness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of radiation hardness of High-Voltage silicon vertical JFETs

In the future ATLAS Inner Tracker, each silicon strip module will be equipped with a switch able to separate the high voltage supply from the sensor in case the latter becomes faulty. The switch, placed in between the HV supply and the sensor, needs to sustain a high voltage in its OFF state, to offer a low resistance path for the sensor leakage current in the ON state, and be radiation hard up to 1.2 * 10 15 neq/cm 2 along with other requirements. While GaN JFETs have been selected as suitable rad-hard switch, a silicon vertical HV-JFET was developed by Brookhaven National Laboratory as an alternative option. Pre-irradiation results showed the functionality of the device and proved that the silicon HV-JFET satisfied the pre-irradiation requirements for the switch. To assess its suitability after irradiation, a few p-type HV-JFETs have been neutron irradiated at Jozef Stefan Institute (JSI, Ljubljana, Slovenia). Overall, this paper reports the static characterization of these irradiated devices and the TCAD numerical simulations used to get an insight of the physics governing the post-irradiation behaviour.

47 OTHER INSTRUMENTATION↗

200 mm sensor development using bonded wafers

Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to > 200m 2 for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than 200 m 2 of silicon and the CMS High Granularity Calorimeter (HGCAL) will require more than 600 m 2 . The cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the size of the silicon sensors. In addition to large area, the devices must be radiation hard, which requires the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work. In this paper we describe work on development of thin sensors on 200 mm wafers using wafer bonding technology. Results of development runs with float zone, Silicon-on-Insulator and Silicon-Silicon bonded wafer technologies are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

The quality control programme for ITk strip tracker module assembly

The assembly of the ATLAS Inner Tracker requires the construction of 19,000 silicon strip sensor detector modules in eight different geometries. Modules will be assembled and tested at 31 institutes on four continents from sensors, readout chips, and flexes. In order to adhere to the module specifications defined for sufficient tracking performance, a rigorous programme of quality control (QC) was established to cover components at every stage of assembly. Here, this contribution presents an overview of the QC programme for ITk strip tracker modules, issues encountered during the pre-production phase (5% of the production volume), and their solutions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AI-assisted detector design for the EIC (AID(2)E)

Artificial Intelligence is poised to transform the design of complex, large-scale detectors like ePIC at the future Electron Ion Collider. Featuring a central detector with additional detecting systems in the far forward and far backward regions, the ePIC experiment incorporates numerous design parameters and objectives, including performance, physics reach, and cost, constrained by mechanical and geometric limits. This project aims to develop a scalable, distributed AI-assisted detector design for the EIC (AID(2)E), employing state-of-the-art multiobjective optimization to tackle complex designs. Supported by the ePIC software stack and using G EANT 4 simulations, our approach benefits from transparent parameterization and advanced AI features. The workflow leverages the PanDA and iDDS systems, used in major experiments such as ATLAS at CERN LHC, the Rubin Observatory, and sPHENIX at RHIC, to manage the compute intensive demands of ePIC detector simulations. Tailored enhancements to the PanDA system focus on usability, scalability, automation, and monitoring. Ultimately, this project aims to establish a robust design capability, apply a distributed AI-assisted workflow to the ePIC detector, and extend its applications to the design of the second detector (Detector-2) in the EIC, as well as to calibration and alignment tasks. Additionally, we are developing advanced data science tools to efficiently navigate the complex, multidimensional trade-offs identified through this optimization process.

97 MATHEMATICS AND COMPUTING↗

Target development using the method of High-Intensity Vibrational Powder Plating (HIVIPP) at the Center for Accelerator Target Science (CATS) at Argonne National Laboratory (ANL)

One of the primary goals of the Center for Accelerator Target Science (CATS) is to provide targets and foils in support of the ATLAS User Facility and the Low-Energy community at large. While a wide array of target production techniques are available at CATS, new methods that must be explored invariably arise. One such technique, the High-Intensity Vibrational Powder Plating (HIVIPP), was first reported in 1997 by Isao Sugai. It was developed to produce targets and stripper foils that were difficult to make by standard methods. At Argonne National Laboratory (ANL), we have successfully constructed and tested a simple system for this purpose. We have produced targets of carbon and titanium on various metal backings using the HIVIPP method. We are currently in the exciting phase of exploring the production of other elements, including isotopically enriched and radioactive material. This work is in progress and will be further detailed with specific examples.

47 OTHER INSTRUMENTATION↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Silicon wafer fracture stress for tracking sensors in particle physics experiments

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below -35°C, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between -35°C and -70°C) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

Detector design and construction technologies and ↗

miss-SNF: a multimodal patient similarity network integration approach to handle completely missing data sources

Abstract Motivation Precision medicine leverages patient-specific multimodal data to improve prevention, diagnosis, prognosis, and treatment of diseases. Advancing precision medicine requires the non-trivial integration of complex, heterogeneous, and potentially high-dimensional data sources, such as multi-omics and clinical data. In the literature, several approaches have been proposed to manage missing data, but are usually limited to the recovery of subsets of features for a subset of patients. A largely overlooked problem is the integration of multiple sources of data when one or more of them are completely missing for a subset of patients, a relatively common condition in clinical practice. Results We propose miss-Similarity Network Fusion (miss-SNF), a novel general-purpose data integration approach designed to manage completely missing data in the context of patient similarity networks. miss-SNF integrates incomplete unimodal patient similarity networks by leveraging a non-linear message-passing strategy borrowed from the SNF algorithm. miss-SNF is able to recover missing patient similarities and is “task agnostic”, in the sense that can integrate partial data for both unsupervised and supervised prediction tasks. Experimental analyses on nine cancer datasets from The Cancer Genome Atlas (TCGA) demonstrate that miss-SNF achieves state-of-the-art results in recovering similarities and in identifying patients subgroups enriched in clinically relevant variables and having differential survival. Moreover, amputation experiments show that miss-SNF supervised prediction of cancer clinical outcomes and Alzheimer’s disease diagnosis with completely missing data achieves results comparable to those obtained when all the data are available. Availability and implementation miss-SNF code, implemented in R, is available at https://github.com/AnacletoLAB/missSNF.

Biochemistry & Molecular Biology↗