Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The potential value of early (1939-1967) upper-air data in atmospheric climate reanalysis

In recent years a number of reanalysis datasets have been published that cover the past century or more, including the ‘Twentieth Century Reanalysis’ 20CRv2 and the European Reanalysis of the twentieth century ERA-20C. These datasets are widely used, showing the need for, and possible benefit of, reanalysis data products designed for climate applications.The twentieth-century reanalyses so far have assimilated only surface observations, and rely on independent estimates of monthly averaged sea-surface temperatures and sea ice concentrations as boundary conditions. While 20CRv2 uses only observations of surface and sea-level pressure, ERA-20C additionally assimilates marine winds.Here we describe an experimental reanalysis, referred to as ERA-PreSAT, which covers the period 1939–1967 and also assimilates historical upper-air data. Assessments of this dataset including comparisons with independent data show that (i) temperature biases in the Northern Hemisphere are largely reduced compared to reanalyses that assimilate surface data only, (ii) concentration of 1940s upper-air data in the northern extra tropics created a strong interhemispheric asymmetry which is likely not realistic, (iii) the forecast skill in the Northern Hemisphere has increased substantially compared to reanalyses that assimilate surface data only, (iv) day-to-day and (in the northern extratropics) month-to-month correlations with independent observations (of total column ozone, upper-air data) increase over time, (v) interannual variability is well captured in the reanalysis, (vi) a signature of the stratospheric Quasi-Biennial Oscillation is present as far back as the 1940s,and (vii) tropical cyclones are not well represented. Furthermore, the generally encouraging results from the experimental ERA-PreSAT reanalysis underline that early upper-air data greatly contribute to our knowledge on the troposphere and lower stratosphere over the twentieth century.

54 ENVIRONMENTAL SCIENCES↗

Lewis Acid Site Assisted Bifunctional Activity of Tin Doped Gallium Oxide and Its Application in Rechargeable Zn‐Air Batteries

The enhanced safety, superior energy, and power density of rechargeable metal‐air batteries make them ideal energy storage systems for application in energy grids and electric vehicles. However, the absence of a cost‐effective and stable bifunctional catalyst that can replace expensive platinum (Pt)‐based catalyst to promote oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) at the air cathode hinders their broader adaptation. Here, in this work, it is demonstrated that Tin (Sn) doped β‐gallium oxide (β‐Ga 2 O 3 ) in the bulk form can efficiently catalyze ORR and OER and, hence, be applied as the cathode in Zn‐air batteries. The Sn‐doped β‐Ga 2 O 3 sample with 15% Sn (Sn x =0.15 ‐Ga 2 O 3 ) displayed exceptional catalytic activity for a bulk, non‐noble metal‐based catalyst. When used as a cathode, the excellent electrocatalytic bifunctional activity of Sn x =0.15 ‐Ga 2 O 3 leads to a prototype Zn‐air battery with a high‐power density of 138 mW cm −2 and improved cycling stability compared to devices with benchmark Pt‐based cathode. The combined experimental and theoretical exploration revealed that the Lewis acid sites in β‐Ga 2 O 3 aid in regulating the electron density distribution on the Sn‐doped sites, optimize the adsorption energies of reaction intermediates, and facilitate the formation of critical reaction intermediate (O*), leading to enhanced electrocatalytic activity.

Lewis acid sites↗

Interfacial and Kinetic Origins of Voltage Loss in Neutral Zinc‐Air Batteries

Rechargeable zinc-air batteries are promising candidates for grid-scale energy storage; however, their practical deployment is limited by oxygen electrocatalysis inefficiencies and interfacial instabilities, particularly outside conventional alkaline electrolytes. Here, in this work, zinc-air batteries operating under neutral electrolyte conditions using ZnCl 2 soaked KC-PAA-PAM gel polymer electrolytes and electrochemically synthesized Ni/Fe layered double hydroxide electrocatalysts is investigated. Ni/Fe-LDH is intentionally employed as an OER-biased benchmark catalyst to diagnose electrolyte and interface driven limitations rather than as a bifunctional ORR/OER solution. Full cells exhibit highly stable cycling over hundreds of hours, yet operate at substantially suppressed charge and discharge voltages relative to the thermodynamic value. Electrochemical impedance analysis shows that ohmic losses contribute only minimally to this voltage suppression. Post-mortem X-ray photoelectron spectroscopy reveals metallic zinc accumulation on the air cathode and chloride-containing species on the anode, indicating parasitic interfacial processes. Synchrotron-based soft X-ray absorption spectroscopy confirms stable Ni 2+ and Fe 3+ oxidation states during cycling, consistent with OER-biased catalytic behavior, while neutral-electrolyte oxygen evolution measurements demonstrate strong electrolyte-induced suppression of oxygen kinetics. Together, these results show that electrolyte chemistry and cathode-side parasitic processes, rather than catalyst identity alone, dominate voltage losses in neutral zinc-air batteries, providing mechanistic insight into the fundamental challenges associated with neutral electrolyte operation.

Long duration energy storage↗

The substantial role of May soil temperature over Central Asia for summer surface air temperature variation and prediction over Northeastern China

The slowly varying soil temperature can exert local and nonlocal influences on regional climate system, and may thus provide a critical source of subseasonal-to-seasonal climate prediction. In this study, we identify that soil temperature in May over the key region of Central Asia (42 °N–50 °N, 62 °E–80 °E, KRCA) from Noah, Mosaic, CLM and ERA-interim datasets is closely linked to variations of the surface air temperature, daily maximum temperature and hot days over Northeastern China in summer (June-July-August), with correlation coefficients of regional average detrended time series ranging from 0.42 to 0.54, and all significant at the 99% confidence level for the period of 1979-2018. The possible physical mechanism behind the substantial downstream impacts of soil temperature over Central Asia are explored via diagnostical analysis combined with regional climate model experiments. Warmer soil temperature in May over the KRCA tends to cause positive anomalies of geopotential height in summer over Northeastern China through the Rossby wave propagation, and associated stronger subsidence warming, less cloud cover, more solar radiation reaching the surface, higher planetary boundary layer, and stronger thermal advection at 850 hPa, which provide favorable conditions for warmer surface air temperature particularly in the daytime as well as more hot days. Here this study further reveals that soil temperature over Central Asia in May makes important contribution to prediction of summer surface air temperature, daily maximum temperature and hot days over Northeastern China in terms of regional average time series and spatial patterns. Our findings highlight the previously-unknown substantial role of antecedent soil temperature condition over Central Asia for summer surface air temperature variation and prediction over Northeastern China.

54 ENVIRONMENTAL SCIENCES↗

Well-to-wheels greenhouse gas and air pollutant emissions from battery electric vehicles in China

Electric vehicles (EVs) play a crucial role in addressing climate change and urban air quality concerns. China has emerged as the global largest EV market with 1.2 million EVs sold in 2018. This study established a novel life cycle energy use and emission inventory collecting up-to-date data including the electricity generation mix, emission controls in the power and industrial sectors, and the energy use in the fuel transport to estimate the well-to-wheels (WTW) greenhouse gas (GHG), and air pollutant emissions for battery electric vehicles (BEVs) and gasoline passenger vehicles in China. The results show that an average BEV has 35% lower WTW GHG emissions than an average gasoline car. BEVs reduce volatile organic compounds (VOCs) and nitrogen oxides (NOX) emissions by 98% and 34%, respectively, but have comparable or slightly higher primary fine particulate matter (PM2.5) and sulfur dioxide (SO2) emissions. Compact and small-size vehicles generally have lower GHG and air pollutant emissions than mid- and large-size vehicles. Class A vehicles contribute the most in the absolute amount of GHG and air pollutant emissions and therefore have the biggest potential for emission reduction. Our results suggest that global policymakers should continue to promote the transition to clean power sources, emission control, and fuel economy regulations, which are critical to enhancing emission mitigation benefits of BEVs. We also suggest EV development strategies should be formulated targeting vehicle class with the biggest emission mitigation potentials.

Air pollutant emissions↗

Experimental and Numerical Study of Coating Thickness Using Multi-slot Air Knives

Gas-jet wiping is a widely employed production technology for controlling the final zinc coating thickness on a moving substrate during continuous hot-dip galvanizing. This paper presents an experimental investigation and numerical analysis of a prototype multi-slot air knife, which offers an increase in wiping efficiency relative to the traditional single-slot jet geometry in the continuous galvanizing process. The applicability of the analytical coating weight model of Elsaadawy et al. (Metall Mater Trans B, 38:413-424, 2007) to predict the final coating weight was determined for the multi-slot geometry, where particular focus was devoted to the effect of geometric parameters. Experimental measurements under a variety of knife geometry and process conditions agreed with the coating weight predictions of the analytical model. It was also shown that the air-knife geometric parameters had a significant effect on the pressure profile and shear stress distribution applied by the air knives to the moving substrate. It was determined that the final coating thickness was significantly affected by the auxiliary jet width, D{sub a}, where lighter coating weights at higher strip velocities (up to 5.4 pct at V{sub s} = 1.5 m/s) could be achieved by using the multi-slot air-knives prototype vs. the conventional single-slot configuration.

36 MATERIALS SCIENCE↗

Dry Sliding Behavior of a TiZr-Based Alloy under Air and Vacuum Conditions

In this study, dry sliding tribological properties of a TiZr-based alloy with the chemical composition Ti-20Zr-6.5Al-4V (wt.%) were tested in air and vacuum under different normal loads (10, 20, and 30 N) at various sliding velocities. Results showed that the coefficient of friction in air was lower than that in vacuum, whereas the wear volume at sliding velocity presented an opposite trend. The surfaces and cross-sectional morphology of wear scar on the TiZrAlV alloy was analyzed through scanning electron microscopy to determine the wear mechanisms. The observations showed that abrasive wear and delamination wear were dominant in air. In vacuum, the main wear mechanism changed from slightly abrasive and adhesive wear to severe adhesive wear and delamination wear as the normal load increased. Wear mechanism maps were also constructed and compared. The comparison showed that severe wear (including delamination wear) was prevalent in air.

36 MATERIALS SCIENCE↗

Research needs targeting direct air capture of carbon dioxide: Material & process performance characteristics under realistic environmental conditions

The extraction of CO 2 from ambient air, or direct air capture (DAC), is a crucial negative CO 2 emissions technology with great potential for contributing to the mitigation of global warming and climate change. Furthermore, nearly all published research on DAC has been conducted under indoor temperature conditions, i.e. 20 to 30 °C. In contrast, the future global implementation of DAC requires it to be operational across a wide expanse of geographical areas, of which the local temperatures can vary between -30 to 50 °C. Similarly, the absolute humidity can vary from ~0 to 84 g/m 3 in various locations. Due to the massive amount of air that would be processed, it may be impractical to preheat or dehumidify the air before the CO 2 separation. Therefore, it is important to develop DAC materials with good performance at realistic outdoor conditions, especially at sub-ambient conditions, i.e. -30 to 20 °C. In addition to material development, system-level studies at sub-ambient conditions are also needed for the DAC processes to reach optimal designs, which may be very different from those at ambient conditions. In this perspective article, we first assess the literature to identify the technical gaps that need to be filled for DAC to be applicable at realistic outdoor conditions. We then suggest additional research directions needed for DAC to be viable under varied conditions from the perspectives of materials and system designs. For materials, we discuss the expected physical and chemical property changes for the sorbents when the temperature or humidity reaches extremes within their range, and how that will impact performance. Similarly, for system design, we indicate how varied conditions will impact performance and how these changes will impact process optimization.

20 FOSSIL-FUELED POWER PLANTS↗

Comparative life cycle assessment of woody biomass processing: air classification, drying, and size reduction powered by bioelectricity versus grid electricity

Sulfur accumulation during biofuel production is pollutive and toxic to conversion catalysts and causes the premature breakdown of processing equipment. Air classification is an effective preprocessing technology for ash and sulfur reduction from biomass feedstocks. Here, a life cycle assessment (LCA) sought to understand the environmental impact of implementing air classification as a sulfur-mitigation technique to improve feedstock quality for pine residues using a grid electricity scenario (GES) versus a bioelectricity scenario (BES). Global warming potential (GWP) for preprocessing was simulated using inventory databases embedded in SimaPro and the Argonne National Laboratory’s GREET model, specifically focusing on comparing the GWP of a GES versus a BES. Overall, the GES had a GWP impact over seven times that of the BES (136 versus 18 kg CO 2 equivalent per tonne of usable feedstock), with steam generation during rotary drying accounting for 57% of the GES’s GWP. Air classification represents 0.4% and 1.6% of the total GWP impact for the GES and BES, respectively. Therefore, air classification can facilitate a 30% reduction in feedstock sulfur content to improve feedstock quality for biofuel conversion and lessen corrosion of equipment while contributing minimal GWP impact during preprocessing.

Air classification↗

The impact of climate on solvent-based direct air capture systems

Direct air capture (DAC) is increasingly seen as a critical technology to reach mid-century net-zero targets and limit climate change to well below 2 °C. While the commercialization of DAC technologies is being pursued by numerous companies, there remains remarkably little information on their performance under “real-world” conditions. In this paper, for the first time, we investigate the influence of temperature and relative humidity of air on the CO 2 capture rate at the air contactor, overall energy requirement, CO 2 capture efficiency, and levelized cost of liquid-solvent based DAC systems. We observe that the overall energy demand decreases from 11.1 to 8.3 GJ/tCO 2 as the CO 2 capture rate increases from 40 to 85 % and that high capture rates can only be achieved in hot and humid climate conditions. We observe that a CO 2 capture rate of 75 % is only possible above 17 °C and 90 % relative humidity, and this drops dramatically at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low relative humidity, as expected. The sensitivity analysis showed that CO 2 capture efficiency is relatively insensitive to climate conditions for the liquid-solvent based DAC plant. Lastly, the levelized cost of natural gas standalone scenario varies from $240/tCO 2 to $409/tCO 2 , and this is more sensitive to temperature than relative humidity. The levelized cost of the natural gas stand-alone case is between 7 % and 10 % lower than that of an electric grid-connected case across all climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Impact of air distribution on dew point evaporative cooler thermal performance

A new geometry of the dew-point indirect evaporative cooler structure was proposed which enables uniform distribution of water in the working channels and application in traditional air handling units. This arrangement requires a complicated structure of the product channel in which the air is cooled. Further, the airflow direction changes and complicated structure it is associated with local losses affecting the total pressure loss. High-pressure drop limits the use of this dew point evaporative cooler as an alternative source of cooling. Therefore, a verified method based on numerical fluid dynamics (CFD) was used to determine the pressure drop and air distribution in the exchanger. The combination of the CFD method and modified epsilon-NTU allows the thermal performance of the device including the uniformity of air distribution, cooling capacity, and coefficient of performance to be determined. Finally, the appropriate exchanger dimensions, i.e., the channel height, or final distribution regulation may be found depending on the exchanger application.

42 ENGINEERING↗

RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

54 ENVIRONMENTAL SCIENCES↗

Measurement of OH density and gas temperature in incipient spark-ignited hydrogen-air flame

To investigate the electrostatic ignition of hydrogen-air mixtures, the density of OH radicals and the gas temperature are measured in an incipient spark-ignited hydrogen-air flame using laser-induced predissociation fluorescence (LIPF). The assessment of the electrostatic hazard of hydrogen is necessary for developing hydrogen-based energy systems in which hydrogen is used in fuel cells. The spark discharge occurs across a 2-mm gap with pulse duration approximately 10 ns. First, a hydrogen (50%)-air mixture is ignited by spark discharge with E=1.35E{sub -}, where E is the spark energy and E{sub -} is the minimum ignition energy. In this mixture, OH density decreases after spark discharge. It is 3 x 10{sup 16}cm{sup -3} at t=0{mu}s and 4 x 10{sup 15}cm{sup -3} at t=100{mu}s, where t is the postdischarge time. On the other hand, the gas temperature increases after spark discharge. It is 900 K at t=30{mu}s and 1400 K at t=200{mu}s. Next, a stoichiometric (hydrogen (30%)-air) mixture is ignited by spark discharge with E=1.25E{sub -}. In this mixture, OH density is approximately constant at 4 x 10{sup 16}cm{sup -3} for 150 {mu}s after spark discharge, and the gas temperature increases from 1000 K (t=0{mu}s) to 1800 K (t=150{mu}s). (author)

08 HYDROGEN↗

The effect of low-NO{sub x} combustion on residual carbon in fly ash and its adsorption capacity for air entrainment admixtures in concrete

Fly ash from pulverized coal combustion contains residual carbon that can adsorb the air-entraining admixtures (AEAs) added to control the air entrainment in concrete. This is a problem that has increased by the implementation of low-NO{sub x} combustion technologies. In this work, pulverized fuel has been combusted in an entrained flow reactor to test the impact of changes in operating conditions and fuel type on the AEA adsorption of ash and NO{sub x} formation. Increased oxidizing conditions, obtained by improved fuel-air mixing or higher excess air, decreased the AEA requirements of the produced ash by up to a factor of 25. This was due to a lower carbon content in the ash and a lower specific AEA adsorptivity of the carbon. The latter was suggested to be caused by changes in the adsorption properties of the unburned char and a decreased formation of soot, which was found to have a large AEA adsorption capacity based on measurements on a carbon black. The NO{sub x} formation increased by up to three times with more oxidizing conditions and thus, there was a trade-off between the AEA requirements of the ash and NO{sub x} formation. The type of fuel had high impact on the AEA adsorption behavior of the ash. Ashes produced from a Columbian and a Polish coal showed similar AEA requirements, but the specific AEA adsorptivity of the carbon in the Columbian coal ash was up to six times higher. The AEA requirements of a South African coal ash was unaffected by the applied operating conditions and showed up to 12 times higher AEA adsorption compared to the two other coal ashes. This may be caused by larger particles formed by agglomeration of the primary coal particles in the feeding phase or during the combustion process, which gave rise to increased formation of soot. (author)

01 COAL, LIGNITE, AND PEAT↗

Using E-PRTR data on point source emissions to air and water—First steps towards a national chemical footprint

There is a great need for indicators to monitor the use and potential impacts of hazardous chemicals. Today there is a huge lack of data, methods and results and method development and studies should be given urgent priority. The aim of this paper was to develop and test an approach to calculate the potential environmental impacts of chemicals for a whole country using the E-PRTR (European Pollutant Release and Transfer Register) as a database and Sweden as an example. Swedish data from 2008 on emissions to air and water for 54 substances from point sources were retrieved from an open database. The data were transformed and aggregated using USEtox, a life-cycle impact assessment (LCIA) method for calculating potential human toxicity and ecotoxicity, both from industrial emissions directly and after input–output analysis (IO analysis) to reallocate emissions to product categories. Zinc to air and water contributed most to human toxicity followed by mercury to air. The largest contribution by industry to potential human toxicity came from the metal industry, followed by the paper and paper product industry. For potential ecotoxicity, zinc, fluoranthene and copper contributed the most. The largest contributions by industry came from the paper and paper products manufacturing sector, followed by the basic metals manufacturing sector. The approach used here can be seen as the first step towards a chemical footprint for nations. By adding data from other countries and other sources, a more complete picture can be gained in line with other footprint calculations. Furthermore, diffuse emissions from, for example, transport or emissions of pesticides could also be added for a more holistic assessment. Since the area of chemicals is complicated, it is probably necessary to develop and use several indicators that complement each other. It is suggested that the approach outlined here could be useful in developing a method for establishing a national chemical footprint. - Highlights: • European Pollutant and Transfer Register (E-PRTR) used to develop indicators • Study combined emissions to air and water from E-PRTR with USEtox and IO analysis • Metals and especially zinc contributed most to potential human toxicity and ecotoxicity • Paper and metal industries contribute most to potential human toxicity and ecotoxicity • This new assessment could be used by many countries and can be developed further.

54 ENVIRONMENTAL SCIENCES↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

A novel method to determine air leakage in heat pump clothes dryers

A heat pump clothes dryer offers the potential to save a significant amount of energy as compared with conventional vented electric dryers. Although heat pump clothes dryers (HPCD) offer higher energy efficiency; it has been observed that they are prone to air leakages, which inhibits the HPCD's gain in efficiency. This study serves to develop a novel method of quantifying leakage, and to determine specific leakage locations in the dryer drum and air circulation system. The basis of this method is the American Society of Testing and Materials (ASTM) standard E779 10, which is used to determine air leakage area in a household ventilation system through fan pressurization. This ASTM method is adapted to the dryer system, and the leakage area is determined by an analysis of the leakage volumetric flow - pressure relationship. Easily accessible leakage points were quantified: the front and back crease (in the dryer drum), the leakage in the dryer duct, the air filter, and the remaining leakage in the drum. The procedure allows investigators to determine major components contributing to leakage in HPCDs, thus improving component design features that result in more efficient HPCD systems.

42 ENGINEERING↗