Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Photocatalytic water splitting for large-scale solar-to-chemical energy conversion and storage

Sunlight-driven water splitting allows renewable hydrogen to be produced from abundant and environmentally benign water. Large-scale societal implementation of this green fuel production technology within energy generation systems is essential for the establishment of sustainable future societies. Among various technologies, photocatalytic water splitting using particulate semiconductors has attracted increasing attention as a method to produce large amounts of green fuels at low cost. The key to making this technology practical is the development of photocatalysts capable of splitting water with high solar-to-fuel energy conversion efficiency. Furthermore, advances that enable the deployment of water-splitting photocatalysts over large areas are necessary, as is the ability to recover hydrogen safely and efficiently from the produced oxyhydrogen gas. This lead article describes the key discoveries and recent research trends in photosynthesis using particulate semiconductors and photocatalyst sheets for overall water splitting, via one-step excitation and two-step excitation (Z-scheme reactions), as well as for direct conversion of carbon dioxide into renewable fuels using water as an electron donor. We describe the latest advances in solar water-splitting and carbon dioxide reduction systems and pathways to improve their future performance, together with challenges and solutions in their practical application and scalability, including the fixation of particulate photocatalysts, hydrogen recovery, safety design of reactor systems, and approaches to separately generate hydrogen and oxygen from water.

30 DIRECT ENERGY CONVERSION↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Nuclear Fuel Cycle: Safe Management of Spent Nuclear Fuel

The aim for storage of spent nuclear fuel (SNF) either in wet or in dry storage systems is to ensure general safety objective s are met throughout a desired storage period. Staff at the Savannah River National Laboratory (SRNL), in collaborations with partners at other national laboratories, industry research organizations, and the University of South Carolina (UofSC), have performed materials aging testing and analyses, and have established nuclear materials aging management programs to support extended periods of safe storage of research reactor (RR) SNF and of commercial power reactor (PR) SNF pending ultimate disposal. Several example challenges include susceptibility of aluminum SNF from research reactors to corrosion in poor quality water (wet storage). In dry storage, aluminum SNF can release hydrogen via radiolysis of the hydrated oxides on the aluminum cladding. Austenitic stainless steel canisters used for dry storage are susceptible to chloride-induced stress corrosion cracking (outside-in attack) that threaten the confinement boundary provided by the canister. This paper further describes these challenges, among others, and the formulated solutions to support extended safe storage of SNF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The weathered bedrock vadose zone: A hidden control on water availability in the western United States (Final Technical Report)

This report summarizes the research completed during the project entitled "The weathered bedrock vadose zone: A hidden control on water availability in the western United States" (Award: DE-SC0018039). The report covers work completed between 9/15/17 and 9/14/20. The objective of the exploratory project work was to evaluate the overarching hypothesis that the subsurface underlying actively eroding landscapes is systematically structured as a result of a balance between weathering and erosion and that this structure leads to dynamic moisture storage within weathered rock. To accomplish project objectives, we characterized hillslope weathering profile structure and conducted subsurface moisture monitoring across four study sites with comparable bedrock types but differing erosion rate and hydroclimate: The Angelo Coast Range Reserve (ACRR), Sagehorn-Russell Ranch (SRR), Antelope Valley Ranch (AVR), and the LBNL Watershed Function Scientific Focus Area (SFA). New characterization and monitoring infrastructure at the AVR and SFA sites was established through this project and enables long-term monitoring of hydrologic and carbon fluxes at the sites for comparison with long-term monitoring in other sites. Deep drilling, downhole logging, and characterization of chemistry and porosity of rock recovered from drilling reveals two weathering fronts across the sites. A shallower front is marked by the extent of pervasive fracturing and oxidation of pyrite and organic carbon. A deeper weathering front is marked by the appearance of open fractures and discoloration. At the AVR site, multiple ridge tops of different hillslope length were investigated to establish the relationship between the weathering front and topography. Drilling reveals that the fraction of the hillslope relief that is weathered scales with hillslope length, consistent with the theoretical framework that guided the project relating groundwater drainage with landscape evolution. With the establishment of new boreholes, we have documented significant water storage in weathered bedrock using low-field borehole nuclear magnetic resonance (NMR) across all four sites. In the upper 4 m of bedrock, the average water contents at ACRR, AVR, SRR, and SFA are approximately 25%, 16%, 25%, 23% respectively. At the ACRR site, where long-term monitoring via neutron probe surveys and time-domain transmission sensors are available, we have demonstrated that NMR reliably records moisture content and importantly, moisture content dynamics in weathered bedrock. Across all sites, our NMR monitoring has also revealed that a considerable fraction of the water storage occurs in fractures or pores that are significantly larger than the fine-grained bedrock matrix of the parent rock. To identify the proportion of water storage occurring in fractures and large pores, we analyzed the NMR signal by evaluating both the sum of echoes and an inversion of the NMR signal for a distribution of T2 relaxation times. Both methods reveal that at least 20% of the water storage occurs in fractures and larger pores across all sites. To constrain the interpretation of the in-situ field-scale NMR measurements, we compare the NMR response in the field to independent pore-structure information obtained via helium pycnometry. Results support the inference that dynamic seasonal water storage is dominantly restricted to the fracture network, which can reach 7% of the total volume. This dynamic range in water content is comparable to that of some soils, underscoring the need to understand how this region of the Earth System is structured, and functions as a hydrologic reservoir.

58 GEOSCIENCES↗

A Perspective on the Successes of the NNSS Underground Test Area (UGTA) Activity - 20221

Between 1951 and 1992, 828 underground nuclear tests were performed at the Nevada National Security Site (NNSS). Underground testing was done in five major testing areas, which included (1) Frenchman Flat, (2) Rainier Mesa/Shoshone Mountain, (3) Yucca Flat/Climax Mine (4) Central Pahute Mesa, and (5) Western Pahute Mesa. About one third of the underground tests were detonated near, at or below the water table, and thus radioactive contamination was introduced to the groundwater system. The U.S. Department of Energy's Underground Test Area (UGTA) Activity was established in the late 1990's to address the fate and movement of residual radioactivity in groundwater, and characterize the risk that it may pose to NNSS workers and the offsite public. It has accomplished this goal through a process of iterative groundwater sampling and numerical groundwater flow and transport modeling, and long-term monitoring. The UGTA Activity draws on the expertise of scientists in the fields of geology, hydrology, radiochemistry, and risk assessment from the U.S. DOE staff, the lead contractor (currently Navarro) and many other organizations, in cooperation with the governing regulatory body, the State of Nevada's Division of Environmental Protection (NDEP). Los Alamos National Laboratory (LANL) is one of the participating research organizations involved with the UGTA Activity. Under the direction of DOE and the lead contractor, LANL's role in UGTA has evolved over time from an initial focus on geologic characterization, to conducting field and laboratory experiments, and finally to its current role of providing modeling and geochemistry expertise to characterize the rates and directions of groundwater and radionuclide movement. In its current role, LANL has either developed or provided the numerical tools for developing flow and transport models in each of the four major testing areas. In addition, LANL has provided an independent assessment of future groundwater flow and transport behavior through the analysis of naturally-occurring geochemical and isotopic tracers in groundwater. The five major testing areas are now in different stages of investigation or closure: (1) Frenchman Flat is in its fifth year of post closure modeling; (2) The Rainier Mesa/Shoshone Mountain Closure Report has been submitted to NDEP and is awaiting approval; (3) The Yucca Flat/Climax Mine Closure Report is under development; and (4) Central and (5) Western Pahute Mesa is still undergoing investigation and flow and transport model development. The success of the UGTA Activity in reaching or approaching closure in three of the five major testing areas is primarily due to the DoE's focus on regulatory closure requirements, but also is in part attributable to a rigorous internal review process and the involvement of NDEP and Nye County water professionals as participants and observers in the reviews. County and state involvement in the internal review process has promoted trust that the U.S. DOE is deeply committed to ensuring the present and future safely of NNSS workers and the surrounding communities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating How Climate Adaptation Measures Affect the Interconnected Water‐Energy Resource Systems of the Western United States

Abstract The Western US faces increasing water stress from the impacts of climate change, making it difficult to meet water demands for the region's cities, agriculture, and hydropower generators. Existing literature suggests that climate adaptation measures such as water conservation, cropland retirement, wastewater recycling, and managed aquifer recharge can alleviate some of these challenges. Few analyses, however, compare the relative efficacy and system‐wide effects of these adaptations under different climate projections across the entire Western United States. Here we use a Western US‐wide water systems model to evaluate, by sector and sub‐region, how the widespread implementation of these adaptive measures impacts water demands, water deliveries, and electricity use related to the water system for three different climate projections. We find that wastewater recycling has greater potential to lower unmet indoor water demands than urban indoor water conservation measures. However, when implemented at scale, indoor water conservation reduces electricity use by an average of 683 Terawatt hours while wastewater recycling increases energy use by an average of 721 Terawatt hours, cumulatively from 2020 to 2070. Cropland retirement and aquifer recharge adaptations increase the ability to meet agricultural water demand, increase groundwater storage, and reduce summertime electricity use. While most of these findings are consistent across different climate projections, the benefits of aquifer recharge are sensitive to spatial variation of precipitation. Given the limitations and tradeoffs of each individually, the results suggest that a portfolio of adaptation measures will be needed for a climate‐resilient water and energy future in the Western US. Plain Language Summary The Western US faces increased water stress from the impacts of climate change, making it difficult to meet demands for cities, agriculture, and hydropower facilities. Adaptation measures like water conservation, retiring agricultural lands, recycling wastewater, and storing water underground can address these challenges. However, there is little modeling to understand the impact of these adaptations if they were implemented across the entire Western US while also considering climate change. We use a Western US‐wide water systems model to evaluate how implementing adaptation measures impacts groundwater levels, the ability to meet water demands, and electricity use related to water in three different possible climate futures. We find that recycling wastewater to drinking water standards does a better job of meeting urban water demands than water conservation measures. However, indoor water conservation reduces energy use for water while recycling wastewater increases energy use for water. Retiring agricultural lands and storing water underground both increase the ability to meet agricultural water demands, increase underground water storage, and reduce summertime energy use. No adaptation measures provides benefits across every metric we track. Therefore, multiple adaptation measures will likely be needed to achieve a climate‐resilient future for energy and water in the Western US. Key Points Water‐related climate change adaptations have different benefits and tradeoffs for interconnected water‐energy systems in the Western U.S. Wastewater recycling most increases urban water coverage, but has a significant tradeoff in the form of greater electricity use Cropland retirement and aquifer recharge benefit water and electricity systems most in the summer when those systems are most stressed

Singhal, A↗

A miniature jet pump for slurries

Here, this work reports on the design and performance of a jet pump system to pump slurries. The jet pump uses a high-velocity water jet to entrain and pump the slurry. This pumping action requires no valves and does not use moving solid parts. Hence, the system can be readily sealed, and the pumping action creates no observable mechanical damage to slurry particles. We tested carbon black beads suspended in water at concentrations of 0.0, 0.2, and 2.0 wt% at primary jet flow rates of 50 and 100 mL/min. Our measurements show an approximately linear decrease in entrainment ratio (slurry-to-jet flow rate) and absolute slurry flow rate with increasing adverse (load) pressure difference. The entrainment ratio is a strong function of the absolute jet flow rate. Pump performance was insensitive to slurry composition. Micron-resolution particle image velocimetry (micro-PIV) revealed qualitative changes in the pump’s internal flow due to changes in absolute jet flow rate, including evidence of the suppression of a vortex at higher flow rates. These findings establish key operational parameters for the jet pump and highlight its potential in a variety of slurry flow pumping applications. The pump is particularly suited for flow electrode slurries (e.g. as used for energy storage and water treatment) as it maintains particle integrity and can be used with standard tubing, tube fittings, and sealing methods.

42 ENGINEERING↗

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗

Evaluation of Nominal Energy Storage at Existing Hydropower Reservoirs in the US

Long-term planning and operation of hydropower reservoirs require an understanding of both water and energy storage. As energy storage needs of the evolving grid increase, we must account for the water and energy storage potential of these reservoirs. Given the limitations of current data on existing hydropower, we compile statistics related to storage volume and hydraulic head from publicly available data sets and examine differences in descriptions of US hydropower storage. Assembled characteristics are used to calculate nominal energy storage capacity, a simple measure of potential to generate power from a given volume of water, not factoring in detailed constraints. Inventory-based estimates of energy storage are calculated at 2,075 dams, which helps put the potential for US hydropower to support energy storage in context with similar evaluations in other regions and with other energy storage technologies. The national energy storage capacity ranges between 34.5 and 45.1 TWh depending on the information used, with 52% of energy storage located at the 10 largest reservoirs in the US. Energy storage capacities are also calculated at 236 dams with historical volume and elevation data. Finally, reservoir inflows provide context for the storage volumes and sensitivities to hydrologic variability. Larger reservoirs with greater storage volume to inflow ratios are concentrated in the Western US, but the majority of hydropower reservoirs store less than the annual inflow. We address several infrastructure and water resource informatics challenges and highlight remaining issues, including representing seasonal or shorter variability in water volumes and representing connected hydropower facilities.

13 HYDRO ENERGY↗

Water Contamination Impacts on Biodiesel Antioxidants and Storage Stability

Biodiesel (fatty acid methyl esters) can oxidize in storage to form acids and gums that negatively impact engine performance and durability. Antioxidant additives are used to increase biodiesel storage stability, and previous studies that evaluated the effectiveness of antioxidants demonstrated that more polar antioxidants tend to be the most effective (provide the largest improvement in stability per unit of antioxidant added). However, polar antioxidants have significant water solubility, and diesel fuel storage tanks are commonly contaminated with water (forming a layer of water under the fuel). This study investigates whether nonpolar antioxidants, which are less effective in dry environments, might be more effective under wet conditions simulating real-world storage. Biodiesel blends treated with polar and nonpolar antioxidants were subjected to accelerated aging using the ASTM D4625 protocol (storage at 43 °C, open to air, for up to 24 weeks) both with and without added water. Fuels treated with polar/higher-effectiveness compounds and stored in contact with water (simulating water in a storage tank) or high humidity showed accelerated loss of stability compared to dry storage. The same fuel treated with a nonpolar antioxidant and stored in the same conditions did not exhibit accelerated stability loss and thus had higher storage stability over the long term despite treatment with an initially less effective additive. Analysis of the fuels during aging showed that this loss of stability was not due to oxidation but rather extraction of the polar antioxidant into the water layer. Antioxidant additives that are incompatible with wet or humid storage conditions were found to cause faster-than-anticipated loss of stability, which was preventable with use of nonpolar additives.

09 BIOMASS FUELS↗

Drying Spent Magnox Fuel for Interim Dry Storage

Spent Magnox fuel is usually stored under water for shielding and cooling following use in-reactor, but the storage water can react with Magnox clad fuel and cause corrosion and forms a sludge which generates a secondary waste product. One option to prevent unwanted corrosion and avoid expensive waste management is to dry the wet fuel. This project aims to test a drying process which will convert wet and corroded Magnox fuel to a stable form to demonstrate viability for conversion from wet to dry storage. Samples of corroded Magnox supplied by National Nuclear Laboratory. Corrosion product retrieved by various methods including dry scraping, ultrasonic treatment to form sludge and sludge drying to isolate suspension. TGA undertaken on Sample 1 and Sample 2, with brucite and hydromagnesite for comparison. Both samples showed ∼10% mass loss up to 250 deg. C attributable to water held in sample. Mass loss from dehydroxylation which liberates further water in both samples. TGA data plotted alongside chemically pure brucite and hydromagnesite shows expected similarities/differences between Sample 1(mostly brucite) and Sample 2 (brucite/hydromagnesite mixture). Following treatment, dried samples observed to slowly gain mass in ambient conditions. Presumed to be hygroscopic absorption of air water vapour as effect is reversible, with similar effect observed for hydromagnesite and brucite. Etched Magnox vacuum dried for 3.5 h at 90 deg. C to test for reaction with residual water - some discoloration but no noticeable corrosion observed. Drying etched Magnox metal to observe surface effects/corrosion during drying process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iron as a driver of organic carbon fate in permafrost regions

Iron (Fe) and its biogeochemical interactions with organic carbon (OC) exert critical controls over carbon storage and water quality across Arctic and sub-Arctic landscapes. Permafrost thaw affects Fe–organic carbon interactions by exposing thawed material and driving shifts in hydrologic regimes. Here we propose a conceptual framework describing how Fe–OC interactions respond to permafrost thaw and the implications for global carbon cycling. The framework builds on current understanding of hydrologically driven processes that are altered by permafrost thaw, including microbial Fe reduction that influences OC decomposition and carbon emissions; Fe cycling through redox transformations and sulfide oxidation; dissolution and reprecipitation of Fe–OC assemblages; and Fe export to river networks. We put forward four testable hypotheses—on topics from Fe supply to its role in soil OC storage and transfer to rivers—to advance understanding of the coupled environmental controls on pore-scale reactions (that is, microscale reactions at mineral–water–microorganism interfaces) that are central to global Fe–OC cycling. Our framework highlights how soil-profile- and landscape-scale processes, such as hydrologic connectivity and redox dynamics, regulate pore-scale Fe–OC reactions.

Herndon, Elizabeth [ORNL] (ORCID:0000000291945493)↗

Green Hydrogen: A Briefing for Land Managers

Decarbonization goals for the U.S. are emphasizing reliance on clean hydrogen produced from renewable resources. Hydrogen can be produced by splitting water, stored, transported, and converted to energy or chemicals. These activities require land, water, and energy. This fact sheet provides insight for federal and state land managers on the resources required to facilitate clean hydrogen production and related activities.

electrolysis↗

Shifting Trade-offs: Finding the Sustainable Nexus of Hydropower and Environmental Flows in the San Joaquin River Watershed, California

Environmental flow management in watersheds with multi-objective reservoirs is often presented as an additional constraint to an already strained and over-allocated stream system. Nevertheless, environmental flow legislation and regulatory policies are increasingly being developed and implemented globally. In California, USA, recent legislative and regulatory policies place environmental flows at the forefront of the state’s water management objectives; however, the increased reliance on hydropower to support climate change mitigation goals may complicate efforts on both issues. This study modelled alternative environmental flow strategies in the major tributaries to the San Joaquin River in California. Strategies included detailed water management rules for hydropower production, flood control, and water deliveries, and three methodological approaches to environmental flow releases: minimum instream flows (“baseline”) year-round, 40% of full natural flow (FNF) during the spring runoff season and minimum releases the remainder of the year, and functional flows year-round. Results show that environmental flow strategies affect downstream flow releases in each of the San Joaquin’s four sub-basins differently depending on infrastructure capacity, water management objectives, and hydrologic year types. While hydropower production was comparable or declined in the Stanislaus, Tuolumne, and Merced basins, functional flow and 40% FNF strategies increased hydropower production in the Upper San Joaquin basin by 11%. Uncontrolled spill of high flow events decreased when high flow releases were based on hydrologic cues rather than exclusively on flood storage capacity. Water deliveries were reduced in all years regardless of environmental flow strategy. The 40% FNF and functional flow strategies both increased water released to the river relative to baseline, but in different ways. The functional flow strategy allocated water in a holistic approach that enhanced ecological functions in all years, but particularly in moderate and wet years. In contrast, the 40% FNF strategy provided increased flows relative to baseline and some ecological benefit in dry years, but less ecological benefit in other years. This study shows that alternative environmental flow strategies will have different and important trade-offs for integrated water management, and may mutually benefit seemingly conflicting objectives.

13 HYDRO ENERGY↗

Structure-Property Relationships of Hydrogel-Salt Composites for Extreme Sorption Performance

Hydrogel-salt composites have emerged as a promising low-cost material for a wide range of sorption applications including thermal energy storage, atmospheric water harvesting, and dehumidification. Despite significant efforts devoted to the synthesis of novel hydrogels and their implementation in sorption devices, very little is known about the fundamental connection between the hydrogel structure and composition with their material-level properties. This knowledge, however, is critical to enable the rational design of high-performance hydrogels targeted at the various applications. In this work, we elucidate via experiments and modeling the link between the hydrogel structure, including its salt content and polymer nanostructure, and its sorption properties. Using lithium chloride-embedded polyacrylamide hydrogels as model systems, we demonstrate that the hydrogel uptake and its kinetics are dominated by the content and properties of the salt. In fact, the polymer nanostructure has no a minor effect in its sorption performance. Based on our experimental insights, we develop a model for the simultaneous diffusion of water and salts in hydrogels, which helps to explain the observed relationship between hydrogel structure and its sorption properties. Furthermore, we leverage these insights to synthesize hydrogels with record-high water vapor uptakes of 1.79 g/g, 2.58 g/g, 3.86 g/g, and 8.51 g/g at 30%, 50%, 70%, and 90% relative humidity, respectively, owing to the use of large amounts of highly hygroscopic salts. By demonstrating the structure-property relationships, this work enables the rational design of salt-embedded hydrogels for low-cost and high-performance thermal energy storage, atmospheric freshwater production, and space conditioning.

Díaz-Marín, Carlos D↗

High-Temperature Alkaline Water Electrolysis

Hydrogen production for mobile and energy storage applications from water electrolysis is attractive due to its high efficiency, fast ramp rates, and potential for the clean energy economy. However, current hydrogen production from electrolysis comprises only a small fraction of the global hydrogen market due to the high cost associated with expensive stack materials (membrane, catalyst, and bipolar plates) and electricity consumption of the commercial electrolysis systems. In this project, we aimed to develop a high temperature alkaline water electrolyzer (HTAWE) that can simultaneously reduce the electrolyzer cost (by adopting cheap material) and improve energy efficiency (by enabling high-temperature operation).

08 HYDROGEN↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗