Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “walls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

ITER cold VDEs in the limit of perfectly conducting walls

Recently, it has been shown that a vertical displacement event (VDE) can occur in ITER even when the walls are perfect conductors, as a consequence of the current quench (CQ) [A. H. Boozer, Phys. Plasmas 26, 114501 (2019)]. We used the extended-MHD code M3D-C1 with an ITER-like equilibrium and induced a CQ to explore cold VDEs in the limit of perfectly conducting walls, using different wall geometries. In the case of a rectangular first wall with the side walls far away from the plasma, we obtained very good agreement with the analytical model developed by Boozer that considers a top/bottom flat-plates wall. We show that the solution in which the plasma remains at the initial equilibrium position is improved when bringing the side walls closer to the plasma. When approximating the ITER first wall as a perfect conductor, the plasma remains stable at the initial equilibrium position far beyond the value predicted by the flat-plates wall limit. When considering an opposite limit in which only the inner shell of the ITER vacuum vessel acts as a perfect conductor, the plasma is displaced during the CQ, but the edge safety factor remains above 2 longer in the current decay compared to the flat-plates wall limit. In all the simulated cases, the VDE is found to be strongly dependent on the plasma current, in agreement with a similar finding in the flat-plates wall limit, showing an important difference with hot VDEs in which the CQ is not a necessary condition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EXPERIMENTAL VALIDATION OF THEORETICAL BURST STRENGTH SOLUTION FOR DEFECT-FREE THICK-WALLED PIPES

The burst pressure of line pipes is an important strength property required in pipeline design and integrity management. Historically, the Barlow formula in conjunction with the ultimate tensile stress (UTS) of pipeline steels were utilized to estimate the burst strength of line pipes. However, the Barlow formula did not consider the plastic flow effect for ductile steels and is applicable only to thin-walled pipes. In 2006, the present author proposed a new multiaxial plastic yield theory and obtained a theoretical Zhu-Leis solution of burst strength for defect-free thin-walled pipes in term of UTS and strain hardening exponent n of pipeline steels. The Zhu-Leis solution has been validated by various burst test data for thin-walled pipelines for a wide range of steel grades from Grade B to X120. Recently, the present author extended the Zhu-Leis theory of plasticity to thick-walled pipes and obtained the Zhu-Leis solution of burst pressure for thick-walled pipes. The proposed burst pressure solution is applicable to both thin and thick-walled pipes. To experimentally validate the proposed theoretical burst pressure solution, this paper obtains a set of burst test data for three thick-walled pipes in Grade B carbon steel with a nominal diameter of 2.375 inches and three nominal wall thicknesses, resulting in D/t = 15.4, 10.9, 6.9. Through comparisons, these burst data validate the theoretical burst pressure solution for thick-walled pipes. Moreover, two additional burst test datasets collected from literature for thin and thick-walled pipes further validate the proposed burst pressure solution for both thin and thick-walled pipes.

Zhu, Xiankui↗

Comparing Retrofit Wall Performance Predicted from Hygrothermal Simulations to Measurements

Over the past few years ORNL has been showing that WUFI® can be used to predict the moisture performance of walls when exposed to diffusion of water vapor, convection of moist air through the wall, and solar driven moisture. This is accomplished by comparing the hygrothermal simulation results to carefully instruments walls exposed to these phenomena in a climate chamber. In FY 2018, three stick-built walls were succumbed to typical Chicago, Illinois weather conditions in Oak Ridge National Laboratory’s Heat, Air and Moisture chamber. The measured temperature, relative humidity, and moisture content within these walls were compared with WUFI hygrothermal simulation results. In FY 2019, similar experiments and comparisons with WUFI results were completed with two walls, a structural insulated panel-based wall and a concrete masonry unit-based wall. In FY 2020, experiments were completed for a probable exterior retrofit of a wall which included adding cavity and continuous insulation. Two pairs of walls were tested by exposing them to Chicago winter weather with a positive pressure pushing outside air into the wall. The results from the FY 2020 experiments are reported here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerofoil testing in a self-streamlining flexible walled wind tunnel

Two-dimensional self-streamlining flexible walled test sections eliminate, as far as experimentally possible, the top and bottom wall interference effects in transonic aerofoil testing. The test section sidewalls are rigid, while the impervious top and bottom walls are flexible and contoured to streamline shapes by a system of jacks, without reference to the aerofoil model. The concept of wall contouring to eliminate or minimise test section boundary interference in two-dimensional testing was first demonstrated by the National Physical Laboratory (NPL) in England during the early 1940's. The transonic streamlining strategy proposed, developed and used by NPL has been compared with several modern strategies. The NPL strategy has proved to be surprisingly good at providing a wall interference-free test environment, giving model performance indistinguishable from that obtained when using the modern strategies over a wide range of test conditions. In all previous investigations the achievement of wall streamlining in flexible walled test sections has been limited to test conditions up to those which result in the model's shock just extending to a streamlined wall. This work, however, has also successfully demonstrated the feasibility of two-dimensional wall streamlining at test conditions where both model shocks have reached and penetrated through their respective flexible walls. Appropriate streamlining procedures have been established and are uncomplicated, enabling flexible walled test sections to easily cope with these high transonic flows.

Mark Charles Lewis↗

Experience with some repeat tests on the 9 inch chord CAST-10-2/DOA 2 airfoil model in the Langley 0.3-m TCT adaptive wall test section

A co-operative testing program is in progress between the Langley Research Center (NASA) and the National Aeronautical Establishment (NAE, Canada) to validate two different techniques of airfoil testing at transonic speeds. The procedure employed is to test the same airfoil model in the NAE two-dimensional tunnel and the Langley 0.3-m Transonic Cryogenic Tunnel (0.3-m TCT). The airfoil model used in testing was CAST-10-2/DOA-2 super-critical airfoil. The Langley 0.3-m TCT has a relatively small cross section of 13 in x 13 in, giving a (h/c) ratio of 1.44 for the same 9 in chord model. The approach employed in the 0.3-m TCT aims towards eliminating the wall effects by using active walls. The top and bottom walls are flexible. By changing the wall shapes during a test in an iterative manner, the wall interference effects are reduced. The method employed to change the wall shapes is the adaptive wall technique. The current test program provided an opportunity to validate the adaptive wall technique in the 0.3-m TCT. The relatively long chord airfoil represents a severe test case to test the efficacy of the adaptive wall technique under cryogenic conditions. The program also involved removal of side wall boundary-layer thus increasing the complexity of the wall adaptation technique. This paper deals with some salient results obtained regarding repeatability of test data and possible residual interference effects.

Murthy, A. V.↗

On the assumption of vanishing temperature fluctuations at the wall for heat transfer modeling

Boundary conditions for fluctuating wall temperature are required for near-wall heat transfer modeling. However, their correct specifications for arbitrary thermal boundary conditions are not clear. The conventional approach is to assume zero fluctuating wall temperature or zero gradient for the temperature variance at the wall. These are idealized specifications and the latter condition could lead to an ill posed problem for fully-developed pipe and channel flows. In this paper, the validity and extent of the zero fluctuating wall temperature condition for heat transfer calculations is examined. The approach taken is to assume a Taylor expansion in the wall normal coordinate for the fluctuating temperature that is general enough to account for both zero and non-zero value at the wall. Turbulent conductivity is calculated from the temperature variance and its dissipation rate. Heat transfer calculations assuming both zero and non-zero fluctuating wall temperature reveal that the zero fluctuating wall temperature assumption is in general valid. The effects of non-zero fluctuating wall temperature are limited only to a very small region near the wall.

Sommer, T. P.↗

A wall interference assessment/correction system

A Wall Signature method originally developed by Hackett was selected to be adapted for the Ames 12-ft Wind Tunnel Wall Interference Assessment/Correction (WIAC) System in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interference at the model location. The lifting interference will be treated separately by representing in a horseshoe vortex system for the model's lifting effects. The development and implementation of a working prototype will be completed, delivered, and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method - Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. The following two additional tasks are included in the supplement No. 1 to the basic Grant. On-line wall interference calculation: The developed wall signature method (modified Hackett's method) for Ames 12-ft Tunnel will be the pre-computed coefficients which facilitate the on-line calculation of wall interference; and support system effects estimation: The effects on the wall pressure measurements due to the presence of the model support systems will be evaluated.

Lo, Ching F.↗

A method for the modelling of porous and solid wind tunnel walls in computational fluid dynamics codes

Porous wall wind tunnels have been used for several decades and have proven effective in reducing wall interference effects in both low speed and transonic testing. They allow for testing through Mach 1, reduce blockage effects and reduce shock wave reflections in the test section. Their usefulness in developing computational fluid dynamics (CFD) codes has been limited, however, by the difficulties associated with modelling the effect of a porous wall in CFD codes. Previous approaches to modelling porous wall effects have depended either upon a simplified linear boundary condition, which has proven inadequate, or upon detailed measurements of the normal velocity near the wall, which require extensive wind tunnel time. The current work was initiated in an effort to find a simple, accurate method of modelling a porous wall boundary condition in CFD codes. The development of such a method would allow data from porous wall wind tunnels to be used more readily in validating CFD codes. This would be beneficial when transonic validations are desired, or when large models are used to achieve high Reynolds numbers in testing. A computational and experimental study was undertaken to investigate a new method of modelling solid and porous wall boundary conditions in CFD codes. The method utilized experimental measurements at the walls to develop a flow field solution based on the method of singularities. This flow field solution was then imposed as a pressure boundary condition in a CFD simulation of the internal flow field. The effectiveness of this method in describing the effect of porosity changes on the wall was investigated. Also, the effectiveness of this method when only sparse experimental measurements were available has been investigated. The current work demonstrated this approach for low speed flows and compared the results with experimental data obtained from a heavily instrumented variable porosity test section. The approach developed was simple, computationally inexpensive, and did not require extensive or intrusive measurements of the boundary conditions during the wind tunnel test. It may be applied to both solid and porous wall wind tunnel tests.

Beutner, Thomas John↗

Wall interaction effects for a full-scale helicopter rotor in the NASA Ames 80- by 120-foot wind tunnel

A full-scale helicopter rotor test was conducted in the NASA Ames 80- by 120-Foot Wind Tunnel with a four-bladed S-76 rotor system. This wind tunnel test generated a unique and extensive data base covering a wide range of rotor shaft angles-of-attack and rotor thrust conditions from 0 to 100 knots. Three configurations were tested: (1) empty tunnel; (2) test stand body (fuselage) and support system; and (3) fuselage and support system with rotor installed. Empty tunnel wall pressure data are evaluated as a function of tunnel speed to understand the baseline characteristics. Aerodynamic interaction effects between the fuselage and the walls of the tunnel are investigated by comparing wall, ceiling, and floor pressures for various tunnel velocities and fuselage angles-of-attack. Aerodynamic interaction effects between the rotor and the walls of the tunnel are also investigated by comparing wall, ceiling, and floor pressures for various rotor shaft angles, rotor thrust conditions, and tunnel velocities. Empty tunnel wall pressure data show good repeatability and are not affected by tunnel speed. In addition, the tunnel wall pressure profiles are not affected by the presence of the fuselage apart from a pressure shift. Results do not indicate that the tunnel wall pressure profiles are affected by the presence of the rotor. Significant changes in the wall, ceiling, and floor pressure profiles occur with changing tunnel speeds for constant rotor thrust and shaft angle conditions. Significant changes were also observed when varying rotor thrust or rotor shaft angle-of-attack. Other results indicate that dynamic rotor loads and blade motion are influenced by the presence of the tunnel walls at very low tunnel velocity and, together with the wall pressure data, provide a good indication of flow breakdown.

Shinoda, Patrick M.↗

Assembly and enlargement of the primary cell wall in plants

Growing plant cells are shaped by an extensible wall that is a complex amalgam of cellulose microfibrils bonded noncovalently to a matrix of hemicelluloses, pectins, and structural proteins. Cellulose is synthesized by complexes in the plasma membrane and is extruded as a self-assembling microfibril, whereas the matrix polymers are secreted by the Golgi apparatus and become integrated into the wall network by poorly understood mechanisms. The growing wall is under high tensile stress from cell turgor and is able to enlarge by a combination of stress relaxation and polymer creep. A pH-dependent mechanism of wall loosening, known as acid growth, is characteristic of growing walls and is mediated by a group of unusual wall proteins called expansins. Expansins appear to disrupt the noncovalent bonding of matrix hemicelluloses to the microfibril, thereby allowing the wall to yield to the mechanical forces generated by cell turgor. Other wall enzymes, such as (1-->4) beta-glucanases and pectinases, may make the wall more responsive to expansin-mediated wall creep whereas pectin methylesterases and peroxidases may alter the wall so as to make it resistant to expansin-mediated creep.

NASA Discipline Plant Biology↗

Microfibril orientation and compositional heterogeneity in fiber and vessel cell walls of poplar xylem studied by AFM-IR and SFG spectroscopy

Understanding the structural organization of cellulose microfibrils (CMFs) within individual plant cell walls is essential for connecting cell wall architecture to its mechanical and physiological functions. However, due to the complex hierarchical structure and nanoscale heterogeneity of cell walls, it remains technically challenging to resolve detailed compositional and orientational information at subcellular levels of individual cell walls. This study investigates the internal 3D structure, chemical composition, and sublayer organization of fiber and vessel cell walls in the xylem tissue of a two-year-old field-grown hybrid poplar tree (Populus alba × P. glandulosa) using photothermal atomic force microscopy coupled with infrared spectroscopy (AFM-IR) and sum frequency generation (SFG) hyperspectral microscopy. AFM-IR provided nanoscale chemical imaging, revealing localized compositional heterogeneity, including variations between adjacent cell walls and transitional layers beyond the traditional S1, S2, and S3 sublayers. SFG microscopy revealed that CMFs in fiber walls are highly aligned along the stem axis, consistent with their role in mechanical support, while vessel cell walls exhibited slightly tilted CMFs, reflecting their function in hydraulic transport. Together, these results offer new insights into cell-type-specific CMF organization and compositional gradients in hybrid poplar xylem. These findings highlight the structural and chemical complexity of secondary cell walls in woody plants and demonstrate the value of AFM-IR and SFG spectroscopy in elucidating plant cell wall architecture.

60 APPLIED LIFE SCIENCES↗

Pectin methylesterase selectively softens the onion epidermal wall yet reduces acid-induced creep

De-esterification of homogalacturonan (HG) is thought to stiffen pectin gels and primary cell walls by increasing calcium cross-linking between HG chains. Contrary to this idea, recent studies found that HG de-esterification correlated with reduced stiffness of living tissues, measured by surface indentation. The physical basis of such apparent wall softening is unclear, but possibly involves complex biological responses to HG modification. To assess the direct physical consequences of HG de-esterification on wall mechanics without such complications, we treated isolated onion (Allium cepa) epidermal walls with pectin methylesterase (PME) and assessed wall biomechanics with indentation and tensile tests. In nanoindentation assays, PME action softened the wall (reduced the indentation modulus). In tensile force/extension assays, PME increased plasticity, but not elasticity. These softening effects are attributed, at least in part, to increased electrostatic repulsion and swelling of the wall after PME treatment. Despite softening and swelling upon HG de-esterification, PME treatment alone failed to induce cell wall creep. Instead, acid-induced creep, mediated by endogenous α-expansin, was reduced. We conclude that HG de-esterification physically softens the onion wall, yet reduces expansin-mediated wall extensibility.

59 BASIC BIOLOGICAL SCIENCES↗

Observation of Antiferroelectric Domain Walls in a Uniaxial Hyperferroelectric

Abstract Ferroelectric domain walls are a rich source of emergent electronic properties and unusual polar order. Recent studies show that the configuration of ferroelectric walls can go well beyond the conventional Ising‐type structure. Néel‐, Bloch‐, and vortex‐like polar patterns have been observed, displaying strong similarities with the spin textures at magnetic domain walls. Here, the discovery of antiferroelectric domain walls in the uniaxial ferroelectric Pb 5 Ge 3 O 11 is reported. Highly mobile domain walls with an alternating displacement of Pb atoms are resolved, resulting in a cyclic 180° flip of dipole direction within the wall. Density functional theory calculations show that Pb 5 Ge 3 O 11 is hyperferroelectric, allowing the system to overcome the depolarization fields that usually suppress the antiparallel ordering of dipoles along the longitudinal direction. Interestingly, the antiferroelectric walls observed under the electron beam are energetically more costly than basic head‐to‐head or tail‐to‐tail walls. The results suggest a new type of excited domain‐wall state, expanding previous studies on ferroelectric domain walls into the realm of antiferroic phenomena.

36 MATERIALS SCIENCE↗

The nonlinear mechanics of highly extensible plant epidermal cell walls

Plant epidermal cell walls maintain the mechanical integrity of plants and restrict organ growth. Mechanical analyses can give insights into wall structure and are inputs for mechanobiology models of plant growth. To better understand the intrinsic mechanics of epidermal cell walls and how they may accommodate large deformations during growth, we analyzed a geometrically simple material, onion epidermal strips consisting of only the outer (periclinal) cell wall, ~7 μm thick. With uniaxial stretching by >40%, the wall showed complex three-phase stress–strain responses while cyclic stretching revealed reversible and irreversible deformations and elastic hysteresis. Stretching at varying strain rates and temperatures indicated the wall behaved more like a network of flexible cellulose fibers capable of sliding than a viscoelastic composite with pectin viscosity. We developed an analytic framework to quantify nonlinear wall mechanics in terms of stiffness, deformation, and energy dissipation, finding that the wall stretches by combined elastic and plastic deformation without compromising its stiffness. We also analyzed mechanical changes in slightly dehydrated walls. Their extension became stiffer and more irreversible, highlighting the influence of water on cellulose stiffness and sliding. This study offers insights into the structure and deformation modes of primary cell walls and presents a framework that is also applicable to tissues and whole organs.

59 BASIC BIOLOGICAL SCIENCES↗

Saccharide analysis of onion outer epidermal walls

Abstract Background Epidermal cell walls have special structural and biological roles in the life of the plant. Typically they are multi-ply structures encrusted with waxes and cutin which protect the plant from dehydration and pathogen attack. These characteristics may also reduce chemical and enzymatic deconstruction of the wall for sugar analysis and conversion to biofuels. We have assessed the saccharide composition of the outer epidermal wall of onion scales with different analytical methods. This wall is a particularly useful model for cell wall imaging and mechanics. Results Epidermal walls were depolymerized by acidic methanolysis combined with 2M trifluoracetic acid hydrolysis and the resultant sugars were analyzed by high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD). Total sugar yields based on wall dry weight were low (53%). Removal of waxes with chloroform increased the sugar yields to 73% and enzymatic digestion did not improve these yields. Analysis by gas chromatography/mass spectrometry (GC/MS) of per- O -trimethylsilyl (TMS) derivatives of the sugar methyl glycosides produced by acidic methanolysis gave a high yield for galacturonic acid (GalA) but glucose (Glc) was severely reduced. In a complementary fashion, GC/MS analysis of methyl alditols produced by permethylation gave substantial yields for glucose and other neutral sugars, but GalA was severely reduced. Analysis of the walls by 13 C solid-state NMR confirmed and extended these results and revealed 15% lipid content after chloroform extraction (potentially cutin and unextractable waxes). Conclusions Although exact values vary with the analytical method, our best estimate is that polysaccharide in the outer epidermal wall of onion scales is comprised of homogalacturonan (~ 50%), cellulose (~ 20%), galactan (~ 10%), xyloglucan (~ 10%) and smaller amounts of other polysaccharides. Low yields of specific monosaccharides by some methods may be exaggerated in epidermal walls impregnated with waxes and cutin and call for cautious interpretation of the results.

09 BIOMASS FUELS↗

Plant Cell Wall Polysaccharide O-Acetyltransferases

Plant cell walls are largely composed of polysaccharide polymers, including cellulose, hemicelluloses (xyloglucan, xylan, mannan, and mixed-linkage β-1,3/1,4-glucan), and pectins. Among these cell wall polysaccharides, xyloglucan, xylan, mannan, and pectins are often O-acetylated, and polysaccharide O-acetylation plays important roles in cell wall assembly and disease resistance. Genetic and biochemical analyses have implicated the involvement of three groups of proteins in plant cell wall polysaccharide O-acetylation: trichome birefringence-like (TBL)/domain of unknown function 231 (DUF231), reduced wall acetylation (RWA), and altered xyloglucan 9 (AXY9). Although the exact roles of RWAs and AXY9 are yet to be identified, members of the TBL/DUF231 family have been found to be O-acetyltransferases responsible for the O-acetylation of xyloglucan, xylan, mannan, and pectins. Here, we provide a comprehensive overview of the occurrence of O-acetylated cell wall polysaccharides, the biochemical properties, structural features, and evolution of cell wall polysaccharide O-acetyltransferases, and the potential biotechnological applications of manipulations of cell wall polysaccharide acetylation. Further in-depth studies of the biochemical mechanisms of cell wall polysaccharide O-acetylation will not only enrich our understanding of cell wall biology, but also have important implications in engineering plants with increased disease resistance and reduced recalcitrance for biofuel production.

Plant Sciences↗

Experiments suitable for wind tunnel wall interference assessment/correction

Three experiments suitable for wall interference assessment and evaluation of proposed correction methods are presented. The experiments are: (1) a series of airfoil tests using a newly designed transonic flow facility that employs side-wall boundary layer suction and upper- and lower-wall shaping; (2) tests on a swept airfoil section spanning a solid-wall wind tunnel with fixed contouring on all four walls; and (3) tests on a swept wing of aspect ratio 3 mounted in a solid-wall wind tunnel with fixed flat walls. Each of the experiments provides data on the airfoil sections as well as on the wind tunnel walls. All the experiments were performed in solid wall wind tunnels corrected for boundary layer displacement effects. Although the experiments were performed primarily to evaluate computer code performance, it is believed that they also provide information that can be used to evaluate methods for assessing and correcting wall interference effects.

Marvin, J. G.↗

Effect of boundary layers on solid walls in three-dimensional subsonic wind tunnels

A solution for the tunnel wall boundary layer effects for three-dimensional subsonic tunnels is presented. The model potentials are represented with simple singularities placed on the centerline of the tunnel and Laplace's equation in cylindrical coordinates is solved for either the conventional homogeneous slotted-wall boundary condition, the solid-wall viscous boundary condition, or a combination of them. The most pronounced wall boundary layer effect is on solid blockage for completely closed wind tunnels. Boundary layers on the wall reduce the blockage from the solid-wall, no-boundary-layer case in a manner similar to opening slots in a solid wall. Additionally, for solid-wall tunnel configurations, the streamline curvature interference factor is reduced by a significant amount, whereas the lift interference factor at the model station does not depend on the boundary layer parameter. For combination wall configurations, the slot effect of the horizontal walls dominates the viscous effect of the solid sidewalls.

Adcock, J. B.↗