Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Results of tests 0A12 and IA9 in the Ames Research Center unitary plan wind tunnels on an 0.030 scale model of the space shuttle vehicle 2A to determine aerodynamic loads, volume 16

Tests were conducted in the NASA/ARC Unitary Plan Wind Tunnels on an 0.030 scale replica of the space shuttle vehicle Configuration 2A. Aerodynamic loads data were obtained at Mach numbers from 0.6 to 3.5. The integrated vehicle was tested at angles of attack and sideslip from -8 degrees to +8 degrees. The isolated orbiter was tested at angles of attack from -15 degrees to +40 degrees and angles of sideslip from -10 degrees to +10 degrees as dictated by trajectory considerations. The effects of orbiter/external tank incidence angle and deflected control surfaces on aerodynamic loads were also investigated.

Spangler, R. H.↗

Results of tests OA12 and IA9 in the Ames Research Center unitary plan wind tunnels on an 0.030-scale model of the space shuttle vehicle 2A to determine aerodynamic loads, volume 18

Tests were conducted, during April and May 1973, on an 0.030-scale replica of the Space Shuttle Vehicle Configuration 2A. Aerodynamic loads data were obtained at Mach numbers from 0.6 to 3.5. The investigation included tests on the integrated (launch) configuration, and on the isolated orbiter (entry configuration). The integrated vehicle was tested at angles of attack and sideslip from -8 degrees to +8 degrees. The isolated orbiter was tested at angles of attack from -15 degrees to +40 degrees and angles of sideslip from -10 degrees to +10 degrees as dictated by trajectory considerations. The effect of orbiter/external tank incidence angle and deflected control surfaces on aerodynamic loads were also investigated.

Spangler, R. H.↗

Orbiting Deep Space Relay Station (ODSRS). Volume 1: Requirement determination

The deep space communications requirements of the post-1985 time frame are described and the orbiting deep space relay station (ODSRS) is presented as an option for meeting these requirements. Under current conditions, the ODSRS is not yet cost competitive with Earth based stations to increase DSN telemetry performance, but has significant advantages over a ground station, and these are sufficient to maintain it as a future option. These advantages include: the ability to track a spacecraft 24 hours per day with ground stations located only in the USA; the ability to operate at higher frequencies that would be attenuated by Earth's atmosphere; and the potential for building very large structures without the constraints of Earth's gravity.

Hunter, J. A.↗

Seasat. Volume 4: Attitude determination

The Seasat project was a feasibility demonstration of the use of orbital remote sensing for global ocean observation. The satellite was launched in June 1978 and was operated successfully until October 1978. A massive electrical failure occurred in the power system, terminating the mission prematurely. The actual implementation of the Seasat Attitude Determination system and the contents of the attitude data files generated by that system are documented. The deviations from plan caused by the anomalous Sun interference with horizon sensors, inflight calibration of Sun sensor head 2 alignment and horizon sensor biomass, estimation of yaw interpolation parameters, Sun and horizon sensor error sources, and yaw interpolation accuracy are included. Examples are given of flight attitude data from all modes of the Orbital Attitude Control System, of the ground processing effects on attitude data, and of cold cloud effects on pitch, and roll data.

Treder, A. J.↗

NASA Conjunction Assessment Organizational Approach and the Associated Determination of Screening Volume Sizes

NASA is committed to safety of flight for all of its operational assets Performed by CARA at NASA GSFC for robotic satellites Focus of this briefing Performed by TOPO at NASA JSC for human spaceflight he Conjunction Assessment Risk Analysis (CARA) was stood up to offer this service to all NASA robotic satellites Currently provides service to 70 operational satellites NASA unmanned operational assets Other USG assets (USGS, USAF, NOAA) International partner assets Conjunction Assessment (CA) is the process of identifying close approaches between two orbiting objects; sometimes called conjunction screening The Joint Space Operations Center (JSpOC) a USAF unit at Vandenberg AFB, maintains the high accuracy catalog of space objects, screens CARA-supported assets against the catalog, performs OD tasking, and generates close approach data.

Conjunction↗

Volumetric measurement of tank volume

A method is disclosed for determining the volume of compressible gas in a system including incompressible substances in a zero-gravity environment consisting of measuring the change in pressure (delta P) for a known volume change rate (delta V/delta t) in the polytrophic region between isothermal and adiabatic conditions. The measurements are utilized in an idealized formula for determining the change in isothermal pressure (delta P sub iso) for the gas. From the isothermal pressure change (delta iso) the gas volume is obtained. The method is also applicable to determination of gas volume by utilizing work (W) in the compression process. In a passive system, the relationship of specific densities can be obtained.

Walter, Richard T.↗

Assessment of Uncertainty-Based Screening Volumes for NASA Robotic LEO and GEO Conjunction Risk Assessment

Conjunction Assessment operations require screening assets against the space object catalog by placing a pre-determined spatial volume around each asset and predicting when another object will violate that volume. The selection of the screening volume used for each spacecraft is a trade-off between observing all conjunction events that may pose a potential risk to the primary spacecraft and the ability to analyze those predicted events. If the screening volumes are larger, then more conjunctions can be observed and therefore the probability of a missed detection of a high risk conjunction event is small; however, the amount of data which needs to be analyzed increases. This paper characterizes the sensitivity of screening volume size to capturing typical orbit uncertainties and the expected number of conjunction events observed. These sensitivities are quantified in the form of a trade space that allows for selection of appropriate screen-ing volumes to fit the desired concept of operations, system limitations, and tolerable analyst workloads. This analysis will specifically highlight the screening volume determination and selection process for use in the NASA Conjunction Assessment Risk Analysis process but will also provide a general framework for other Owner / Operators faced with similar decisions.

Narvet, Steven W.↗

Methods for determining enzymatic activity comprising heating and agitation of closed volumes

Methods for determining thermophilic enzymatic activity include heating a substrate solution in a plurality of closed volumes to a predetermined reaction temperature. Without opening the closed volumes, at least one enzyme is added, substantially simultaneously, to the closed volumes. At the predetermined reaction temperature, the closed volumes are agitated and then the activity of the at least one enzyme is determined. The methods are conducive for characterizing enzymes of high-temperature reactions, with insoluble substrates, with substrates and enzymes that do not readily intermix, and with low volumes of substrate and enzyme. Systems for characterizing the enzymes are also disclosed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas volume contents within a container, smart volume instrument

A method for determining the volume of an incompressible gas in a system including incompressible substances in a zero-gravity environment. The method includes inducing a volumetric displacement within a container and measuring the resulting pressure change. From this data, the liquid level can be determined.

Kelley, Anthony R.↗

From QCD to physical resonances

Here in this talk, we present the first chiral extrapolation of a resonant scattering amplitude obtained from lattice QCD. Finite-volume spectra, determined by the Hadron Spectrum Collaboration at m π = 236 MeV [1], for the isotriplet ππ channel are analyzed using the Lüscher method to determine the infinite-volume scattering amplitude. Unitarized Chiral Perturbation Theory is then used to extrapolate the scattering amplitude to the physical light quark masses. The viability of this procedure is demonstrated by its agreement with the experimentally determined scattering phase shift up to center-of-mass energies of 1.2 GeV. Finally, we analytically continue the amplitude to the complex plane to obtain the ρ -pole at [ 755 ( 2 ) ( 1 ) ( 02 20 ) - i 2 129 ( 3 ) ( 1 ) ( 1 7 ) ]

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of depth-viewing volumes for stereo three-dimensional graphic displays

Real-world, 3-D, pictorial displays incorporating true depth cues via stereopsis techniques offer a potential means of displaying complex information in a natural way to prevent loss of situational awareness and provide increases in pilot/vehicle performance in advanced flight display concepts. Optimal use of stereopsis requires an understanding of the depth viewing volume available to the display designer. Suggested guidelines are presented for the depth viewing volume from an empirical determination of the effective region of stereopsis cueing (at several viewer-CRT screen distances) for a time multiplexed stereopsis display system. The results provide the display designer with information that will allow more effective placement of depth information to enable the full exploitation of stereopsis cueing. Increasing viewer-CRT screen distances provides increasing amounts of usable depth, but with decreasing fields-of-view. A stereopsis hardware system that permits an increased viewer-screen distance by incorporating larger screen sizes or collimation optics to maintain the field-of-view at required levels would provide a much larger stereo depth-viewing volume.

Parrish, Russell V.↗

Tank gauging apparatus and method

Apparatus for gauging the amount of liquid in a container of liquid and gas under flow or zero gravity net conditions includes an accumulator and appropriate connector apparatus for communicating gas between the accumulator and the container. In one form of the invention, gas is removed from the container and compressed into the accumulator. The pressure and temperature of the fluid in the container is measured before and after removal of the gas; the pressure and temperature of gas in the accumulator is measured before and after compression of the gas into the accumulator from the container. These pressure and temperature measurements are used in determining the volume of gas in the container, whereby the volume of liquid in the container can be determined from the difference between the known volume of the container and the volume of gas in the container. Gas from the accumulator may be communicated into the container in a similar process as a verification of the gauging of the liquid volume, or as an independent process for determining the volume of liquid in the container.

Morris, Brian G.↗

Echocardiographic measurements of left ventricular mass by a non-geometric method

The accuracy of a new nongeometric method for calculating left ventricular myocardial volumes from two-dimensional echocardiographic images was assessed in vitro using 20 formalin-fixed normal human hearts. Serial oblique short-axis images were acquired from one point at 5-deg intervals, for a total of 10-12 cross sections. Echocardiographic myocardial volumes were calculated as the difference between the volumes defined by the epi- and endocardial surfaces. Actual myocardial volumes were determined by water displacement. Volumes ranged from 80 to 174 ml (mean 130.8 ml). Linear regression analysis demonstrated excellent agreement between the echocardiographic and direct measurements.

Parra, Beatriz↗

Determination of Internal Target Volume From a Single Positron Emission Tomography/Computed Tomography Scan in Lung Cancer

Purpose: The use of four-dimensional computed tomography (4D-CT) to determine the tumor internal target volume (ITV) is usually characterized by high patient radiation exposure. The objective of this study was to propose and evaluate an approach that relies on a single static positron emission tomography (PET)/CT scan to determine the ITV, thereby eliminating the need for 4D-CT and thus reduce patient radiation dose. Methods and Materials: The proposed approach is based on the concept that the observed PET image is the result of a joint convolution of an ideal PET image (free from motion and partial volume effect) with a motion-blurring kernel (MBK) and partial volume effect. In this regard, the MBK and tumor ITV are then estimated from the deconvolution of this joint model. To test this technique, phantom and patient studies were performed using different sphere/tumor sizes and motion trajectories. In all studies, a 4D-CT and a PET/CT image of the sphere/tumor were acquired. The ITV from the proposed technique was then compared to the maximum intensity projection (MIP) volume of the 4D-CT images. A Dice coefficient of the two volumes was calculated to represent the similarity between the two ITVs. Results: The average ITVs of the proposed technique were 97.2% {+-} 0.3% and 81.0% {+-} 16.7% similar to the MIP volume in the phantom and patient studies, respectively. The average dice coefficients were 0.87 {+-} 0.05 and 0.73 {+-} 0.16, respectively, for the two studies. Conclusion: Using the proposed approach, a single static PET/CT scan has the potential to replace a 4D-CT to determine the tumor ITV. This approach has the added advantage of reducing patient radiation exposure and determining the tumor MBK compared to 4D-CT/MIP-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗