A Review of Distributed Secondary Control Architectures in Islanded-Inverter-Based Microgrids

The increasing energy demand, the shortage of energy resources, and the environmental challenges faced by conventional power-generation systems are some of the ongoing challenges faced by modern power systems. Therefore, many efforts have been made by the scientific community to develop comprehensive solutions to overcome these issues. For instance, current technological advances have allowed the integration of distributed generators into the power systems, promoting the use of microgrids to overcome these issues. However, the use of renewable distributed generators have introduced new challenges to the traditional control system schemes. To overcome these challenges, a hierarchical control approach has been proposed for distributed renewable sources. In other words, the control scheme have been divided into three hierarchical levels, primary, secondary, and tertiary, to overcome the new challenges present in modern power systems. Due to extensiveness of this topic, this overview is focused on secondary control systems, mainly for AC isolated microgrids. To improve the power quality of modern systems, several secondary control schemes have been proposed to overcome the well-known problem of frequency and voltage deviation. Some of these schemes have also introduced adequate active/reactive power sharing techniques to optimize the utilization of resources. Additionally, other secondary control schemes have also focused on reducing the communication load, to lower the network cost and adding robustness against communication problems. This article presents an insight of the different control techniques used to overcome power quality and communication problems. A comprehensive overview of distributed secondary control techniques for islanded microgrids is presented. In addition, the implementation of these techniques is explained in an orderly and sequential manner.

14 SOLAR ENERGY↗

Steady-state and dynamic characteristics of a 20-kHz spacecraft power system - Control of harmonic resonance

A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.

Wasynczuk, O.↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

Improving the electrostatic design of the Jefferson Lab 300 kV DC photogun

The 300 kV DC high voltage photogun at Jefferson Lab was redesigned to deliver electron beams with a much higher bunch charge and improved beam properties. The original design provided only a modest longitudinal electric field ( E z ) at the photocathode, which limited the achievable extracted bunch charge. To reach the bunch charge goal of approximately few nC with 75 ps full-width at half-maximum Gaussian laser pulse width, the existing DC high voltage photogun electrodes and anode–cathode gap were modified to increase E z at the photocathode. In addition, the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the non-symmetric nature of the inverted insulator photogun design. We present the electrostatic design of the original photogun and the modified photogun and beam dynamics simulations that predict vastly improved performance. We also quantify the impact of the photocathode recess on beam quality, where recess describes the actual location of the photocathode inside the photogun cathode electrode relative to the intended location. A photocathode unintentionally recessed/misplaced by sub-millimeter distance can significantly impact the downstream beam size.

47 OTHER INSTRUMENTATION↗

Voltage Optimization

Voltage optimization refers to a volt-var optimization technique which was originally designed to minimize energy consumption and improve end-use efficiency on the distribution system. This reduces source voltage at a substation, which lowers generation demand, reduces system losses, and improves system stability. This has been the conventional implementation of voltage optimization: focusing on regulation of voltages throughout the distribution system via coordinated adjustments of load tap changers, line-voltage regulators, switched shunt compensation, and the targeted placement of new shunt compensation. These methods have received increased focus following a growth in distributed-energy resources (DERs) interconnecting at the distribution level, given their developing capability to participate in voltage regulation. This is paired with the intermittency challenges they pose, load imbalances, and voltage fluctuations. Voltage optimization has long been an area of extensive research within the distribution system, with various strategies and philosophies demonstrating a range of effects. The conventional focus on the distribution system owes to the typical operation of transmission systems, which assumes firm local resources and flows strictly from generation resources to loads. The strategies employed in distribution have also been optimized for this typically radial configuration and operation of the distribution system.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

Caldera Infrastructure Charge Module (ICM)

Caldera ICM is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. The foundation of Caldera ICM is it’s first-of-its-kind library of high-fidelity charging models for a wide variety of vehicles, validated by test data under a range of operating conditions. The charging models are used to accurately model the EV charging on an electric vehicle supply equipment (EVSE) – also known as a charger. ICM uses as inputs, the EV characteristics such as battery size, battery chemistry (i.e. NMC, LTO), watt hour per mile, inverter efficiency and max charge rate; as well as EVSE characteristics such as max current and supply equipment type (i.e. L2 vs XFC). Using these inputs Caldera ICM creates an uncontrolled charging profile curve for each compatible EV-EVSE pair. These charge profiles can be used stand alone to estimate charge duration given start State Of Charge (SOC) and end SOC or charge energy size given start SOC and charge duration. In Caldera Grid, another tool in the Caldera software platform, these charge profiles are used to represent EV charging as a load on the grid using charge event data such as EV type, SE type, start SOC, final SOC, park start time and park end time. ICM currently supports energy shifting Smart Charge Management (SCM) strategies such as "Time Of Use (TOU) immediate”, “TOU random” and “random start” by delaying the charge to start at a preferable time with respect to the strategy and, one voltage support SCM strategy named autonomous voltage control strategy by providing reactive power back to the electric grid.

Sundarrajan, ManojKumar Cebol↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗