Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemical “Pickling” of Phosphite Additives Mitigates Impedance Rise in Li Ion Batteries

The use of high-voltage, high-capacity positive electrodes in lithium-ion batteries presents a challenge, given their tendency to degrade organic electrolytes. To prevent this damage, electrolyte additives modifying the cathode surface are required. Tris(trimethylsilyl) phosphite (TMSPi) is one of such electrolyte additives. However, the mechanism for its protective action (similarly to other phosphite, borate, and boroxane compounds) remains not completely understood. In LiPF6 containing carbonate electrolytes, TMSPi undergoes reactions yielding numerous products. Here we demonstrate that one of these products, PF2OSiMe3, is responsible for mitigation of impedance rise that occurs in aged cells during charge/discharge cycling. This same agent can also be responsible for reducing parasitic oxidation currents and transition metal loss during prolonged cell cycling. Mechanistic underpinnings of this protective action are examined using computational methods. Our study suggests that this beneficial action originates mainly through inhibition of catalytic centers for electrolyte oxidation that are present on the cathode surface, by forming capping ligands on the transition metal ions that block solvent access to such centers.

capacity fade↗

Unraveling the Voltage-Fade Mechanism in High-Energy-Density Lithium-Ion Batteries: Origin of the Tetrahedral Cations for Spinel Conversion

Discovery of high-voltage layered lithium-and manganese-rich (LMR) composite oxide electrode has dramatically enhanced the energy density of current Li-ion energy storage systems. However, practical usage of these materials is currently not viable because of their inability to maintain a consistent voltage profile (voltage fading) during subsequent charge-discharge cycles. This report rationalizes the cause of this voltage fade by providing the evidence of layer to spinel-like (LSL) structural evolution pathways in the host Li 1.2 Mn 0.55 Ni 0.15 Co 0.1 O 2 LMR composite oxide. By employing neutron powder diffraction, and temperature dependent magnetic susceptibility, we show that LSL structural rearrangement in LMR oxide occurs through a tetrahedral cation intermediate via: i) diffusion of lithium atoms from octahedral to tetrahedral sites of the lithium layer [(Li Li oct →Li Li tet] which is followed by the dispersal of the lithium ions from the adjacent octahedral site of the metal layer to the tetrahedral sites of lithium layer [Li TM oct → Li Li tet]; and ii) migration of Mn from the octahedral sites of the transition metal layer to the permanent octahedral site of lithium layer via tetrahedral site of lithium layer [Mn TM oct Mn Li tet Mn Li oct)]. The findings opens the door to the potential routes to mitigate this atomic restructuring in the high-voltage LMR composite oxide cathodes by manipulating the composition/structure for practical use in high-energy-density lithium-ion batteries.

25 ENERGY STORAGE↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

A Voltage Bias Effect on Catalytic Activity of Electrically Continuous Pt/TiO 2 Nanocomposites

Abstract Recently, efforts to optimize catalytic performance have included the utilization of catalytic nanoparticles with careful control over their shape and size, chemical composition, surface functionalization, and structural architecture. Here, direct measurements are reported detailing the impact of applied external bias on the exothermic catalytic formation of water for a Pt/TiO 2 nanocomposite under exposure to gaseous oxyhydrogen environments. As external voltages of opposite polarity are applied to the system, the surface temperature kinetics, total pressure kinetics within the analytical chamber, and water turnover frequency transition in a reproducible manner between two well‐defined states which result in 1) decreased catalytic activity, 2) decreased initial molecular adsorption onto the Pt catalyst, and 3) lower rates of water production under negative voltage. These findings pave the road toward the realization of a catalytic switch that can be activated by applying a voltage to Schottky barrier systems to enhance or mitigate catalytic surface reactions.

Ray, Nathan J.↗

Impact of Lithium‐Free Borate Additives on the Cycle Life and Calendar Aging of Silicon‐Based Lithium‐Ion Batteries

Silicon-anode lithium-ion batteries (LIBs) suffer from limited cycle life and poor calendar life, constraining their large-scale commercialization. Integrating additives into electrolytes is a simple and cost-effective strategy to improve these aspects. The effects of lithium-free boron-based additives on cycling and calendar performance of high-loading Si-anode LIBs remain largely unexplored. In this work, the influence of five Li-free borate additives, each with distinct molecular structures and elemental compositions, is systematically investigated. All additives enhance cycle life to varying extents. Notably, the addition of 1 v/v% tri(2,2,2-trifluoroethyl) borate to the baseline electrolyte nearly doubles the cycle life at 50% state of health. This enhancement is attributed to three key factors. Specifically, borate additives 1) improve electrochemical activity, 2) act as anion receptors that interact with [PF6]- anions and carbonate solvents to reduce electrolyte decomposition, and 3) promote the formation of a stable and polymeric solid electrolyte interphase layer. Furthermore, these additives exhibited negligible impact in mitigating leakage current during a 180 h voltage-hold calendar-aging test, indicating their limited effect in calendar life. These findings provide insight into the role of Li-free borate additives in improving cycle life while addressing the knowledge gap regarding their influence on calendar aging.

Li, Defu↗

A layered Prussian blue analogue as fast-charging negative electrode material for lithium-ion batteries

The simultaneous achievement of fast-charging and high specific capacity remains a critical challenge for lithium-ion battery negative electrodes. Here we report a layered manganese-based Prussian blue analogue, synthesized through vacancy control and subsequent thermal transformation. As a conversion-type negative electrode, this material exhibits high-rate performance, delivering a specific capacity of 510 mAh g −1 at a specific current of 8 A g −1 , and operates at a moderate average voltage of approximately 1.2 V vs. Li/Li + , which mitigates lithium plating risks. This high-rate capability stems from the analogue’s specific linkage configurations, which facilitate a high content of active transition metal and strong Li+ adsorption at nitrogen sites. The high transition metal content enables a high reversible capacity, while strong Li + adsorption promotes an efficient initial crystalline-to-amorphous transformation. This process induces dynamically reversible component migration during subsequent cycling, thereby enhancing conversion reaction kinetics. Our findings provide insights into the application of Prussian blue analogues as fast-charging negative electrode materials. The development of fast-charging and high-capacity negative electrodes is critical for advanced lithium-ion batteries. Here, authors use a vacancy engineering strategy to develop a layered Prussian blue analogue with competitive rate capability, delivering a specific capacity of 510 mAh g −1 at a specific current of 8 A g −1 .

25 ENERGY STORAGE↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Quasi-Static Time-Series PV Hosting Capacity Methodology and Metrics

Distributed photovoltaic systems (DPV) can cause adverse grid impacts, including voltage or thermal violations. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current methods for determining hosting capacity tend to be conservative by either only considering infrequent worst-case snapshots in time and/or only capturing coarse time and spatial resolution. Additionally, current hosting capacity methods do not accurately capture the time-dependence making them unable to capture the behavior of voltage regulating equipment and of some advanced controls mitigations. This can trigger delays from unnecessary engineering analysis or deter solar installations in areas that are actually suitable. We propose a quasi-static-time-series (QSTS) based PV hosting capacity methodology to address these issues. With this approach, we conduct power flow analysis over the course of a full year, to capture time-varying parameters and control device actions explicitly. We show that this approach can more fully capture grid impacts of DPV than traditional methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sacramento Municipal Utility District PV and Smart Grid Pilot at Anatolia

Under DE-FOA-0000085 High Penetration Solar Deployment, the U. S. Department of Energy funded agreements with SMUD and Navigant Consulting, SunPower, GridPoint, the National Renewable Energy Laboratory, and the California Energy Commission for this pilot demonstration project. Funding was $5,962,409.00. Cost share of $500,000 was also provided by the California Energy Commission. The project has strategic implications for SMUD, other utilities and the PV and energy-storage industries in business and resource planning, technology deployment and asset management. These implications include: -At this point, no dominant business models have emerged and the industry is open for new ideas. -Demonstrated two business models for using distributed PV and energy storage, and brainstormed several dozen more, each with different pros and cons for SMUD, its customers and the industry. -Energy storage can be used to manage high penetrations of PV and mitigate potential issues such as reverse power flow, voltage control violations, power quality issues, increased wear and tear on utility equipment, and system wide power supply issues. - Smart meters are another tool utilities can use to manage high penetrations of PV. The necessary equipment and protocols exist, and the next step is to determine how to integrate the functionality with utility programs and what level of utility control is required. - Time-of-use rates for the residential customers who hosted energy storage systems did not cause a significant change in energy usage patterns. However, the rates we used were not optimized for PV and energy storage. Opportunities exist for utilities to develop new structures.

14 SOLAR ENERGY↗

The Effects of Background Pressure on SPT-140 Thruster Performance at Multiple Power Levels

NASA's planned Psyche mission is scheduled to launch in 2022 and begin a 3.5-year cruise to the metallic asteroid Psyche, where it would examine this unique body. The baseline spacecraft design is a hybrid of JPL's deep-space heritage subsystems with commercial partner SSL's power, structure, and SPT-140 electric propulsion subsystems. Since the deep-space implementation of the SPT-140 differs from the commercial implementation, primarily in the need for deep power throttling, characterization of the system at lower powers is necessary. One specific area of interest is the sensitivity of thruster performance to background pressure in ground-based test facilities, which can have an impact on the prediction of in-space performance. Measurements of this pressure dependence were performed on a qualification-model SPT-140 thruster over the 0.9-4.5 kW range of interest for the Psyche mission. Thrust sensitivity to pressure, in an absolute sense, was largest at 4.5 kW and decreased with power until there was little-to-no measurable effect at 0.9 kW. In a relative sense, thrust sensitivity was similar at all powers above 0.9 kW with about 2-4% higher thrust measured at 10 μTorr than at the lowest operating pressure. Thruster stability margin, examined as a function of magnet current, did not have a strong dependence on facility pressure. Finally, an investigation of low-power operation at the lowest facility pressure showed that a combination of added cathode keeper current and additional cathode propellant flow significantly mitigated the larger negative cathode-to-ground voltages that were observed. These test results, combined with thruster life test results, inform the selection of proper low-power operating conditions for Psyche.

Snyder, John S.↗

The Effects of Background Pressure on SPT-140 Hall Thruster Performance

NASA’s planned Psyche mission is scheduled to launch in 2022 and begin a 3.5-year cruise to the metallic asteroid Psyche, where it would examine this unique body. The baseline spacecraft design is a hybrid of JPL’s deep-space heritage subsystems with commercial partner SSL’s power, structure, and SPT-140 electric propulsion subsystems. Since the deepspace implementation of the SPT-140 differs from the commercial implementation, primarily in the need for deep power throttling, characterization of the system at lower powers is necessary. One specific area of interest is the sensitivity of thruster performance to background pressure in ground-based test facilities, which can have an impact on the prediction of in-space performance. Measurements of this pressure dependence were performed on a qualification-model SPT-140 thruster over the 0.9-4.5 kW range of interest for the Psyche mission. Thrust sensitivity to pressure, in an absolute sense, was largest at 4.5 kW and decreased with power until there was little-to-no measurable effect at 0.9 kW. In a relative sense, thrust sensitivity was similar at all powers above 0.9 kW with about 2-4% higher thrust measured at 10 µ µTorr than at the lowest operating pressure. Thruster magnetic field sensitivity, examined as a function of magnet current, did not have a strong dependence on facility pressure. Finally, an investigation of low-power operation at the lowest facility pressure showed that a combination of added cathode keeper current and additional cathode propellant flow significantly mitigated the larger negative cathode-to-ground voltages that were observed. These test results, combined with thruster life test results, inform the selection of proper low-power operating conditions for Psyche.

Mackey, Jonathan A.↗

Quasi-Static Times Series PV Hosting Capacity Methodology and Metrics: Preprint

Distributed photovoltaic systems (DPV) can cause adverse grid impacts, including voltage or thermal violations. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current methods for determining hosting capacity tend to be conservative by either only considering infrequent worst-case snapshots in time and/or only capturing coarse time and spatial resolution. Additionally, current hosting capacity methods do not accurately capture the time-dependence making them unable to capture the behavior of voltage regulating equipment and of some advanced controls mitigations. This can trigger delays from unnecessary engineering analysis or deter solar installations in areas that are actually suitable. We propose a quasi-static-timeseries (QSTS) based PV hosting capacity methodology to address these issues. With this approach, we conduct power flow analysis over the course of a full year, to capture time-varying parameters and control device actions explicitly. We show that this approach can more fully capture grid impacts of DPV than traditional methods.

14 SOLAR ENERGY↗

Design Challenges in High-Current Pulsed Striplines

The Long Baseline Neutrino Facility (LBNF) will produce the worlds most intense neutrino beam. Three series connected magnetic horns will require 5 kV, 300 kA, 800 $\mu$s pulses at a rate of 1.4 Hz to focus the beam. Connecting a single power supply to these focusing horns will require a low impedance connection measuring over 60 m in length. To meet the challenging requirements of connecting the horns to the power supply, this connection is engineered as a nine-conductor, high-current pulsed stripline. It must pass through a harsh radiation environment, be passively cooled, and have an operational lifetime of at least 30 years. This paper discusses mechanical and electrical considerations such as high-voltage holdoff, clamped joint performance, and Lorentz force mitigations in order to meet the specified requirements. The results of tests and experiments on several prototypes of key design features will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Mitigating Band Tailing in Kesterite Solar Absorbers: Ab Initio Quantum Dynamics

Open-circuit voltage deficits are limiting factors in kesterite solar cells. Addressing this issue by suppressing band tailing and nonradiative charge recombination is essential for enhancing the performance. We employ ab initio nonadiabatic molecular dynamics to elucidate the origin of band tailing and charge losses and propose a mitigation strategy. The simulations show that Cu–Zn disorder, associated with antisite defect clusters [Cu Zn +Zn Cu ], is a significant source of band tailing in kesterites, as evidenced by the much larger Urbach energy in disordered than ordered kesterites. Cu–Zn disorder gives rise to new sulfur-centered coordination polyhedra, increases structural inhomogeneity, changes electrostatic potential at sulfur centers, and shifts the S(3p) orbital energy. Differences in the S(3p)/Cu(3d) and S(3p)/Sn(5s) hybridization strengths and the S(3p) orbital energy shift reduce the band gap by 0.37 eV. Furthermore, Cu–Zn disorder enhances vibrational motion of sulfur anions and surrounding cations, increasing band gap fluctuations by 15 meV. The stronger electron–phonon interactions reduce charge carrier lifetimes and limit the kesterite solar cell efficiency. Partial substitution of Zn with Cd facilitates structural ordering and significantly suppresses band tailing, particularly in disordered systems. The improvement can be attributed to the larger atomic radius and mass of Cd, which weakens bonding around the anion, suppresses S-related vibrations within the covalent tetrahedra, and reduces nonadiabatic coupling, thereby increasing charge carrier lifetimes. The reported results establish the key influence of cation disorder on band tailing and reduced charge carrier lifetimes in kesterites and highlight cation disorder engineering as a strategy to achieve high-efficiency kesterite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cyberattack Detection and Mitigation on Central Volt‐VAr Using Circuit Law and Machine Learning

ABSTRACT In a distribution grid, voltage is maintained within a nominal range through a Volt‐VAr function that controls capacitor banks, reactive power of distributed energy resources (DER), and on‐load tap changers (OLTC). Availability of communications helps with the implementation of central Volt‐VAr control; however, it also opens the system to cyberattacks, causing voltage disturbances. Previous work has shown the adverse impacts of false data injection (FDI) on the central Volt‐VAr control; however, very few works have studied methods to detect and mitigate FDI on Volt‐VAr control. This paper addresses gaps in the detection and mitigation of FDI on the measurement packets of a central Volt‐VAr control. This work uses a two‐stage algorithm for cyberattack detection since the accuracy of a single‐stage machine learning (ML)–based detection method decreases while dealing with unseen data. The first stage is based on the verification of measurements against circuit laws, and the second stage utilizes a tree search algorithm and an ML method to detect the falsified data. This paper compares long short‐term memory (LSTM) and bidirectional LSTM (BiLSTM) as the employed ML algorithms. Finally, the mitigation algorithm replaces the falsified data with the estimated output of the ML algorithm. The effectiveness of the proposed method is tested for several cases using the IEEE 13‐bus test system in PSCAD software.

Beikbabaei, Milad [Bradley Department of Electrica↗

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗