Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “viscosity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Acoustic Experiment to Measure the Bulk Viscosity of Near-Critical Xenon in Microgravity

We plan a rigorous test of the theory of dynamic scaling by accurately measuring the bulk viscosity of xenon in microgravity 50 times closer to the critical temperature T(sub c) than previous experiments. The bulk viscosity zeta (or "second viscosity" or "dilational viscosity") will be determined by measuring the attenuation length of sound alpha lambda and also measuring the frequency-dependence of the speed of sound. For these measurements, we developed a unique Helmholtz resonator and specialized electro-acoustic transducers. We describe the resonator, the transducers, their performance on Earth, and their expected performance in microgravity.

Gillis, K. A.↗

Stirring Up an Elastic Fluid: Critical Viscosity of Xenon-2 (CVX-2)

Whipped cream stays in place even when turned upside down. Yet it readily flows through the nozzle of a spray can to reach the dessert plate. This demonstrates the phenomenon of shear thinning that is important to many industrial and physical processes. Paints, film emulsions, and other complex solutions that are highly viscous under normal conditions but become thin and flow easily under shear forces. A simple fluid, such as water, does not exhibit shear thinning under normal conditions. Very close to the liquid-vapor critical point, where the distinction between liquid and vapor disappears, the fluid becomes more complex and is predicted to display shear thinning. At the critical point, xenon atoms interact over long distances in a classical model of cooperative phenomena. Physicists rely on this system to learn how long-range order arises. The Critical Viscosity of Xenon Experiment (CVX-2) will measure the viscous behavior of xenon, a heavy inert gas used in flash lamps and ion rocket engines, at its critical point. Although it does not easily combine with other chemicals, its viscosity at the critical point can be used as a model for a range of fluids. Viscosity originates from the interactions of individual molecules. It is so complicated that, except for the simplest gas, it cannot be calculated accurately from theory. Tests with critical fluids can provide key data, but are limited on Earth because critical fluids are highly compressed by gravity. CVX-2 employs a tiny metal screen vibrating between two electrodes in a bath of critical xenon. The vibrations and how they dampen are used to measure viscosity. CVX flew on STS-85 (1997), where it revealed that, close to the critical point, the xenon is partly elastic: it can 'stretch' as well as flow. For STS-107, the hardware has been enhanced to determine if critical xenon is a shear-thinning fluid.

Berg, Robert F.↗

Surface Tension and Viscosity of SCN and SCN-acetone Alloys at Melting Points and Higher Temperatures Using Surface Light Scattering Spectrometer

Succinonitrile has been and is being used extensively in NASA's Microgravity Materials Science and Fluid Physics programs and as well as in several ground-based and microgravity studies including the Isothermal Dendritic Growth Experiment (IDGE). Succinonitrile (SCN) is useful as a model for the study of metal solidification, although it is an organic material, it has a BCC crystal structure and solidifies dendriticly like a metal. It is also transparent and has a low melting point (58.08 C). Previous measurements of succinonitrile (SCN) and alloys of succinonitrile and acetone surface tensions are extremely limited. Using the Surface Light Scattering technique we have determined non invasively, the surface tension and viscosity of SCN and SCN-Acetone Alloys at different temperatures. This relatively new and unique technique has several advantages over the classical methods such as, it is non invasive, has good accuracy and measures the surface tension and viscosity simultaneously. The accuracy of interfacial energy values obtained from this technique is better than 2% and viscosity about 10 %. Succinonitrile and succinonitrile-acetone alloys are well-established model materials with several essential physical properties accurately known - except the liquid/vapor surface tension at different elevated temperatures. We will be presenting the experimentally determined liquid/vapor surface energy and liquid viscosity of succinonitrile and succinonitrile-acetone alloys in the temperature range from their melting point to around 100 C using this non-invasive technique. We will also discuss about the measurement technique and new developments of the Surface Light Scattering Spectrometer.

Tin, Padetha↗

Transient Torque Method: A Fast and Non-Intrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of semiconducting or metallic melts. The experimental setup is similar to that for the oscillation cup technique. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate along its axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with the published data. The main advantage of the technique is that the measurement can be completed in one or two minutes, as opposed to the one or two-hour measurement time required by the oscillation cup technique. The method is non-intrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer if desired.

Li, C.↗

Density, Electrical Conductivity and Viscosity of Hg(sub 0.8)Cd(sub 0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt were measures as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(sub 0.8)Cd(sub 0.2)Te melt as the temperature was decreased to below 1090 K.

Li, C.↗

Torque Transient of Magnetically Drive Flow for Viscosity Measurement

Viscosity is a good indicator of structural changes for complex liquids, such as semiconductor melts with chain or ring structures. This paper discusses the theoretical and experimental results of the transient torque technique for non-intrusive viscosity measurement. Such a technique is essential for the high temperature viscosity measurement of high pressure and toxic semiconductor melts. In this paper, our previous work on oscillating cup technique was expanded to the transient process of a magnetically driven melt flow in a damped oscillation system. Based on the analytical solution for the fluid flow and cup oscillation, a semi-empirical model was established to extract the fluid viscosity. The analytical and experimental results indicated that such a technique has the advantage of short measurement time and straight forward data analysis procedures

Ban, Heng↗

Density, Electrical Conductivity and Viscosity of Hg(0.8)Cd(0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(0.8)Cd(0.2)Te melt were measured as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(0.8)Cd(0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(0.8)Cd(0.2)Te melt as the temperature was decreased to below 1090 K

Li, C.↗

Progress on Acoustic Measurements of the Bulk Viscosity of Near-Critical Xenon (BVX)

We plan to determine the bulk viscosity of xenon 10 times closer [in reduced temperature tau = (T-Tc)/Tc] to its liquid-vapor critical point than ever before. (Tc is the critical temperature.) To do so, we must measure the dispersion and attenuation of sound at frequencies 1/100 of those used previously. In general, sound attenuation has contributions from the bulk viscosity acting throughout the volume of the xenon as well as contributions from the thermal conductivity and the shear viscosity acting within thin thermoacoustic boundary layers at the interface between the xenon and the solid walls of the resonator. Thus, we can determine the bulk viscosity only when the boundary layer attenuation is small and well understood. We present a comparison of calculations and measurements of sound attenuation in the acoustic boundary layer of xenon near its liquid-vapor critical point.

Gillis, Keith A.↗

An Experimental Investigation of the Influence of the Lubricant Viscosity and Additives on Gear Wear

The influence of lubricant viscosity and additives on the average wear rate of spur gear pairs was investigated experimentally. The gear specimens of a comprehensive gear durability test program that made use of seven lubricants covering a range of viscosities were examined to measure gear tooth wear. The measured wear was related to the as-manufactured surface roughness, the elastohydrodynamic film thickness, and the experimentally determined contact fatigue lives of the same specimens. In general, the wear rate was found to be inversely proportional to the viscosity of the lubricant and to the lambda ratio (also sometimes called the specific film thickness). The data also show an exponential trend between the average wear rates and the surface fatigue lives. Lubricants with similar viscosities but differing additives and compositions had somewhat differing gear surface fatigue lives and wear rates.

Krantz, Timothy L.↗

Fluid Merging Viscosity Measurement (FMVM) Experiment on the International Space Station

The concept of using low gravity experimental data together with fluid dynamical numerical simulations for measuring the viscosity of highly viscous liquids was recently validated on the International Space Station (ISS). After testing the proof of concept for this method with parabolic flight experiments, an ISS experiment was proposed and later conducted onboard the ISS in July, 2004 and subsequently in May of 2005. In that experiment a series of two liquid drops were brought manually together until they touched and then were allowed to merge under the action of capillary forces alone. The merging process was recorded visually in order to measure the contact radius speed as the merging proceeded. Several liquids were tested and for each liquid several drop diameters were used. It has been shown that when the coefficient of surface tension for the liquid is known, the contact radius speed can then determine the coefficient of viscosity for that liquid. The viscosity is determined by fitting the experimental speed to theoretically calculated contact radius speed for the same experimental parameters. Experimental and numerical results will be presented in which the viscosity of different highly viscous liquids were determined, to a high degree of accuracy, using this technique.

Antar, Basil N.↗

Results of the Fluid Merging Viscosity Measurement International Space Station Experiment

The purpose of FMVM is to measure the rate of coalescence of two highly viscous liquid drops and correlate the results with the liquid viscosity and surface tension. The experiment takes advantage of the low gravitational free floating conditions in space to permit the unconstrained coalescence of two nearly spherical drops. The merging of the drops is accomplished by deploying them from a syringe and suspending them on Nomex threads followed by the astronaut s manipulation of one of the drops toward a stationary droplet till contact is achieved. Coalescence and merging occurs due to shape relaxation and reduction of surface energy, being resisted by the viscous drag within the liquid. Experiments were conducted onboard the International Space Station in July of 2004 and subsequently in May of 2005. The coalescence was recorded on video and down-linked near real-time. When the coefficient of surface tension for the liquid is known, the increase in contact radius can be used to determine the coefficient of viscosity for that liquid. The viscosity is determined by fitting the experimental speed to theoretically calculated contact radius speed for the same experimental parameters. Recent fluid dynamical numerical simulations of the coalescence process will be presented. The results are important for a better understanding of the coalescence process. The experiment is also relevant to liquid phase sintering, free form in-situ fabrication, and as a potential new method for measuring the viscosity of viscous glass formers at low shear rates.

Ethridge, Edwin C.↗

High-Fidelity Simulations of Gravity Currents Using a High-Order Finite-Difference Spectral Vanishing Viscosity Approach

This numerical work investigates the potential of a high-order finite-difference spectral vanishing viscosity approach to simulate gravity currents at high Reynolds numbers. The method introduces targeted numerical dissipation at small scales through altering the discretisation of the second derivatives of the viscous terms in the incompressible Navier-Stokes equations to mimic the spectral vanishing viscosity (SVV) operator, originally designed for the regularisation of spectral element method (SEM) solutions of pure advection problems. Using a sixth-order accurate finite-difference scheme, the adoption of the SVV method is straightforward and comes with a negligible additional computational cost. In order to assess the ability of this high-order finite-difference spectral vanishing viscosity approach, we performed large-eddy simulations (LES) of a gravity current in a channelised lock-exchange set-up with our SVV model and with the well-known explicit static and dynamic Smagorinsky sub-grid scale (SGS) models. The obtained data are compared with a direct numerical simulation (DNS) based on more than 800 million mesh nodes, and with experimental measurements. A framework for the energy budget is introduced to investigate the behaviour of the gravity current. First, it is found that the DNS is in good agreement with the experimental data for the evolution of the front location and velocity field as well as for the stirring and mixing inside the gravity current. Secondly, the LES performed with less than 0.4% of the total number of mesh nodes compared to the DNS, can reproduce the main features of the gravity currents, with the SVV model yielding slightly more accurate results. It is also found that the dynamic Smagorinsky model performs better than its static version. For the present study, the static and dynamic Smagorinsky models are 1.8 and 2.5 times more expensive than the SVV model, because the latter does not require the calculation of explicit SGS terms in the Navier-Stokes equations nor spatial filtering operations.

direct numerical simulation↗

Stability, Combustion, and Compatibility of High-Viscosity Heavy Fuel Oil Blends with a Fast Pyrolysis Bio-Oil

Properties related to the combustion, stability, and compatibility of blends composed of high-viscosity heavy fuel oil (HFO) and highly acidic pyrolysis bio-oil were determined to assess the utility of bio-oil as a marine fuel. The addition of bio-oil was shown to be fully stable with HFO at blend levels up to 50 mass % for up to 2 weeks. Bio-oil concentrations as low as 5 mass % significantly reduced the viscosity of HFO at 25 and 50 °C. Aging studies at 50 and 90 °C showed that the HFO inhibited the polymerization of bio-oil. The heating value and lubricity showed a linear dependency with bio-oil content, and combustion quality was acceptable for blends containing up to 15% bio-oil. The highly acidic bio-oil was found to be corrosive to carbon steel, 2.25Cr-1Mo steel, and 409 stainless steels, but not 304L and 316L. When blended into HFO at levels less than 19 mass %, no measurable corrosion was observed on any of the steel materials, but a 50 mass % concentration produced low-to-moderate corrosion in the carbon steel, 2.25Cr-1Mo steel, and 409 stainless steel grades. The combination of good blend stability, polymerization inhibition, reduced viscosity, and acceptable compatibility for low blend levels suggests that bio-oils may be suitable for use as a marine fuel.

09 BIOMASS FUELS↗

Investigation of resonant layer response in electron viscosity regime

We present a supplementary study of previous work in Waybright and Park [Phys. Plasmas 31, 022502 (2024)] which demonstrates a substantial effect of electron viscosity on the resonant layer response to non-axisymmetric magnetic perturbations. A main refinement is to include a curl element of electron viscosity in the generalized Ohm's law. The refinement reveals a resonant layer response in the electron viscosity regime corresponding to slowly rotating and highly viscous plasmas.

Asymptotic analysis↗

Variable domain mutational analysis to probe the molecular mechanisms of high viscosity of an IgG 1 antibody

Subcutaneous injection is the preferred route of administration for many antibody therapeutics for reasons that include its speed and convenience. However, the small volume limit (typically ≤2 mL) for subcutaneous delivery often necessitates antibody formulations at high concentrations (commonly ≥100 mg/mL), which may lead to physicochemical problems. For example, antibodies with large hydrophobic or charged patches can be prone to self-interaction giving rise to high viscosity. Here, we combined X-ray crystallography with computational modeling to predict regions of an anti-glucagon receptor (GCGR) IgG 1 antibody prone to self-interaction. An extensive mutational analysis was undertaken of the complementarity-determining region residues residing in hydrophobic surface patches predicted by spatial aggregation propensity, in conjunction with residue-level solvent accessibility, averaged over conformational ensembles from molecular dynamics simulations. Dynamic light scattering (DLS) was used as a medium throughput screen for self-interaction of ~200 anti-GCGR IgG 1 variants. A negative correlation was found between the viscosity determined at high concentration (180 mg/mL) and the DLS interaction parameter measured at low concentration (2–10 mg/mL). Additionally, anti-GCGR variants were readily identified with reduced viscosity and antigen-binding affinity within a few fold of the parent antibody, with no identified impact on overall developability. The methods described here may be useful in the optimization of other antibodies to facilitate their therapeutic administration at high concentration.

59 BASIC BIOLOGICAL SCIENCES↗

Classical and quantum computing of shear viscosity for ( 2 + 1 ) D SU(2) gauge theory

We perform a nonperturbative calculation of the shear viscosity for ( 2 + 1 )-dimensional SU(2) gauge theory by using the lattice Hamiltonian formulation. The retarded Green’s function of the stress-energy tensor is calculated from real time evolution via exact diagonalization of the lattice Hamiltonian with a local Hilbert space truncation, and the shear viscosity is obtained via the Kubo formula. When taking the continuum limit, we account for the renormalization group flow of the coupling but no additional operator renormalization. We find the ratio of the shear viscosity and the entropy density η s is consistent with a well-known holographic result 1 4 π at several temperatures on a 4 × 4 honeycomb lattice with the local electric representation truncated at j max = 1 2 . We also find the ratio of the spectral function and frequency ρ x y ( ω ) ω exhibits a peak structure when the frequency is small. Both the exact diagonalization method and simple matrix product state classical simulation method beyond j max = 1 2 on bigger lattices require exponentially growing resources. So we develop a quantum computing method to calculate the retarded Green’s function and analyze various systematics of the calculation including j max truncation and finite size effects, Trotter errors and the thermal state preparation efficiency. Our thermal state preparation method still requires resources that grow exponentially with the lattice size, but with a very small prefactor at high temperature. We test our quantum circuit on both the Quantinuum emulator and the IBM simulator for a small lattice and obtain results consistent with the classical computing ones. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nickel Hydroxide Nanofluid Cathodes with High Solid Loadings and Low Viscosity for Energy Storage Applications

Nanofluid electrodes with high loading of active solid materials have significant potential as high energy density flow battery electrolytes; however, two key criteria need to be met: they must have a manageable viscosity for pumping and simultaneously exhibit good electrochemical activity. A typical dispersion of nickel hydroxide nanoparticles (~100 nm) is limited to 5–10 wt.% of solids, above which it has a paste-like consistency, incompatible with flow applications. We report on the successful formulation of stable dispersions of a nano-scale nickel hydroxide cathode (β-Ni(OH) 2 ) with up to 60 wt.% of solids and low viscosity (32 cP at 25 °C), utilizing a surface graft of small organic molecules. The fraction of grafting moiety is less than 3 wt.% of the nanoparticle weight, and its presence is crucial for the colloidal stability and low viscosity of suspensions. Electrochemical testing of the pristine and modified β-Ni(OH) 2 nanoparticles in the form of solid casted electrodes were found to be comparable with the latter exhibiting a maximum discharge capacity of ~237 mAh/g over 50 consecutive charge–discharge cycles, close to the theoretical capacity of 289 mAh/g.

25 ENERGY STORAGE↗

Renewable low viscosity polyester-polyols for biodegradable thermoplastic polyurethanes

In the transition to renewably sourced, biodegradable polymers, the preparation of low viscosity polyester-polyols has posed a challenge for renewable polyurethane (PU) development. Low viscosity polyols not only reduce the requirement for high process temperatures but also decrease manufacturing time. In our efforts to incorporate increasing ratios of bio-based monomers into renewable PUs, we mixed diacids such as even carbon sebacic acid and odd carbon azelaic acid along with a renewable diol. This provided library of 2000 g/mol molecular weight polyester-polyols, and structures were established by 1 H and 13 C NMR analysis. The prepared polyester-polyols offered lower viscosity and enable lower fabrication temperatures to make TPUs, and their structure and material metrics were evaluated. The formation of TPUs is ascertained from FTIR and NMR analysis. The final TPUs displayed good physical and mechanical properties. Further, these TPUs exhibited T g in the range of -56.5 to -39.7°C, corresponding to TPU soft block structure, and T m between 98.3 and 105.1°C originating from the hard segment. Prepared TPUs exhibit excellent biodegradation under compost environmental conditions. These TPUs showed up to 57% decrease in molecular weight by GPC analysis after 9 weeks of biodegradation, and respirometer analysis displayed up to 97% biodegradation over 120 days.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗