Development Specification for the FN-323/324, Oxygen Ventilation Loop Fan Assembly

This specification establishes the requirements for design, performance, safety, and manufacture of the FN-323/324, Oxygen Ventilation Loop Fan Assembly as part of the Advanced EMU (AEMU) Portable Life Support System (PLSS). Fan development for the advanced Portable Life Support System (PLSS) began in 2009 with the development of Fan 1.0. This fan was used in PLSS 2.0 for circulation of the ventilation loop gas. Fan 2.0 was delivered in 2015 and will be used in the PLSS 2.5 Live Loads test series. This fan used the same motor as Fan 1.0, but had a larger volute and impeller in hopes of achieving lower speeds. The next iteration of the advanced PLSS fan is the subject of the requirements contained within this document, and will be used with the PLSS 2.5 -302 configuration.

Ralston, Russell↗

Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

particulate matter filtration↗

Development of a Multi-Stage Filter System for Cabin Ventilation Systems on the ISS and Future Deep Space Missions

The National Aeronautics and Space Administration's (NASA's) deep space exploration missions will be of significant duration requiring long-life and reliably performing spacecraft cabin ventilation filters. A particulate filter system is being developed at NASA Glenn Research Center (GRC) to meet the challenges of these remote and long duration missions. The capabilities and features of the filter system are expected to expand the life and reduce the maintenance requirements over that of the current ISS (International Space Station) filter by providing pre-filtration stages with novel self-cleaning and regenerable techniques. The filter provides two regenerable pre-filtration stages using a screen mesh media and an impactor collection system, and also provides intermediate stage filtration employing self-replacing filter media. The filter system is also designed to be compatible with the interfaces and performance requirements of the ISS distributed ventilation architecture in the US modules to facilitate testing on ISS type test or mock up platforms. Currently, a prototype of the filter system is undergoing tests in a custom configured filter test stand at the NASA GRC. The test stand provides the same range of flow rates produced on the ISS distributed architecture, and is equipped and instrumented to perform filter tests based on industrial test standards. The test stand has been used successfully to perform filter and flow performance test on returned ISS Bacterial Filter Elements. Similar test protocols were used to characterize the performance of the current filter system. Different performing grades of filter media will be installed and tested on the filter system, and different test particle standards will be used to simulate the range of particulate matter particles and debris the filter will see during a mission. This paper will present results and analysis of the test data to guide and provide input to the next generation filter system.

ISS↗

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery↗

A review of computing-based automated fault detection and diagnosis of heating, ventilation and air conditioning systems

We report faults in Heating, Ventilation, and Air Conditioning (HVAC) systems of buildings result in significant energy waste in building operation. With fast-growing sensing data availability and advancement in computing, computational modeling has demonstrated strong capability to detect and diagnose HVAC system faults, hence, ensuring efficient building operation. This paper comprehensively reviews the state-of-the-art computing-based fault detection and diagnosis (FDD) for HVAC systems. Overall, the reviewed computing-based FDD methods are classified as two major approaches: knowledge-based and data-driven approaches. We then identify multiple important topics, including data availability, training data size, data quality, approach generality, capability, interpretability, and required modeling efforts, along with corresponding metrics to summarize the most updated FDD development. Generally, the knowledge-based approaches are further divided as physics-based modeling, Diagnostic Bayesian Network, and performance indicator-based methods while data-driven approaches include supervised learning, unsupervised learning, and regression and statistics-based methods. State-of-the-art FDD development, remaining challenges, and future research directions are further discussed to push forward FDD in practice. Availability of fault data, capability of existing methods to deal with complex fault situations (such as simultaneous faults), modeling interpretability for data-driven methods, and required engineering efforts for physics-based methods are identified as remaining challenges in FDD development. Improving modeling fidelity and reducing modeling efforts are essential for applying physics-based methods in real buildings. Meanwhile, addressing fault data availability, increasing algorithm adaptability, and handling multiple faults are essential to further enhance the applicability of data-driven FDD approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Different Types of Entrances on Natural Ventilation in a Subway Station

In this study, the natural ventilation of a horizontal entrance of a typical subway station is investigated based on numerical simulations and experiments. In addition, a renormalization group k-e model (RNG k-e model) is applied to compute both the internal and external airflow patterns. Computational fluid dynamics (CFD) simulations are validated based on the experimental results. Furthermore, a multiple variable regression model is employed to study how the different parameters affect the internal airflow rates of the subway station statistically, according to the experimental results. For this typical model, the parameter importance can be ranked as follows: (1) outdoor wind speed; (2) flow resistance of the subway station; (3) height of the wind catcher; and (4) length of the wind catcher. To understand the detailed pressure distribution of the horizontal entrance of the subway station with and without the wind catcher, 3D numerical simulations are conducted for different scenarios. We attempt to alter the size of the wind catcher (including the length and height) to study the characteristics of the pressure on the horizontal entrance of the subway station under outdoor wind-driven conditions. The pressure distributions for the entrance for different scenarios are compared and analyzed. Finally, the interactions between the internal and external flows are investigated by changing the resistance of the subway station. When the internal flow resistance is changed, the pressure coefficient (Cp) of the entrance is different as well. Hence, the Cp is not only affected by the outdoor environment, but is also influenced by the internal airflows.

CFD↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Validation of measurements of ventilation-to-perfusion ratio inequality in the lung from expired gas

The analysis of the gas in a single expirate has long been used to estimate the degree of ventilation-perfusion (Va/Q) inequality in the lung. To further validate this estimate, we examined three measures of Va/Q inhomogeneity calculated from a single full exhalation in nine anesthetized mongrel dogs under control conditions and after exposure to aerosolized methacholine. These measurements were then compared with arterial blood gases and with measurements of Va/Q inhomogeneity obtained using the multiple inert gas elimination technique. The slope of the instantaneous respiratory exchange ratio (R slope) vs. expired volume was poorly correlated with independent measures, probably because of the curvilinear nature of the relationship due to continuing gas exchange. When R was converted to the intrabreath Va/Q (iV/Q), the best index was the slope of iV/Q vs. volume over phase III (iV/Q slope). This was strongly correlated with independent measures, especially those relating to inhomogeneity of perfusion. The correlations for iV/Q slope and R slope considerably improved when only the first half of phase III was considered. We conclude that a useful noninvasive measurement of Va/Q inhomogeneity can be derived from the intrabreath respiratory exchange ratio.

NASA Discipline Cardiopulmonary↗

Highlights of Aeroacoustic Tests of a Metal Spacecraft Cabin Ventilation Fan Prototype

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and tested in the NASA Glenn Research Center Acoustical Testing Laboratory. The fan design featured a low-noise blade-vane count that was chosen to reduce the rotor-stator interaction tone noise. The fan was throttled through its operating range, and results indicate that the measured aerodynamic and acoustic performance was in good agreement with predictions. Recommendations for further research of quiet high-performance fans intended to support long duration human space exploration missions are offered. This small fan aerodynamic and acoustic test rig and the NASA Glenn Acoustical Testing Laboratory are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Fan↗

Highlights of Aeroacoustic Tests of a Metal Spacecraft Cabin Ventilation Fan Prototype

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and tested in the NASA Glenn Research Center Acoustical Testing Laboratory. The fan design featured a low-noise blade-vane count that was chosen to reduce the rotor-stator interaction tone noise. The fan was throttled through its operating range, and results indicated that the measured aerodynamic and acoustic performance was in good agreement with predictions. Recommendations for further research of quiet high-performance fans intended to support long duration human space exploration missions are offered. This small fan aerodynamic and acoustic test rig and the NASA Glenn Acoustical Testing Laboratory are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Fan, Noise, Ventilation↗

Quiet Spacecraft Cabin Ventilation Fan: Vibration Measurements Results

Quiet, efficient fans with minimal vibrations are needed to maximize the mechanical life of atmospheric revitalization system fans used for human life support systems for long duration space exploration missions. Several metal spacecraft cabin ventilation fan prototypes have been designed, built, and tested at the NASA Glenn Research Center Acoustical Testing Laboratory. Tests performed in 2021 of the first prototype of the metal fan measured vibrations greater than desired at design point speed and backpressure conditions. To try to reduce those vibrations, a second prototype of the fan design was developed which included a new lighter rotor with a tighter balance tolerance, a new collet to attach the rotor to the motor shaft more securely and repeatably, and a new bracket to center and hold the motor in the fan centerbody more precisely. The second prototype of the fan was tested in 2023 and the vibrations were measured with the fan operating at design point speeds in isolation but not throttled to design point back pressure conditions since it was not installed with inlet and exhaust ducting. Peak vibration was reduced from 4 mm/s to 1 mm/s. This paper is part of a series of reports documenting the performance of the prototype fan.

Fan↗

Spacecraft Cabin Ventilation Fan: Wake Measurements Results

Quiet, efficient fans with minimal vibrations are required for revitalization system fans used for human support system in long duration space exploration missions. A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed in NASA Glenn research center. Two copies of the fan assembly were fabricated and tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot-wire measurements of the fan wake. Hot-wire measurements were obtained by radially traversing a x-wire probe downstream of the rotor. This report documents the phase-locked wake velocity, flow angle and turbulence measurements from the hot-wire surveys as part of a series of reports.

Hotwire Measurement↗

Quiet Spacecraft Cabin Ventilation Fan: Vibration Measurements Results

The vibrations of a metal spacecraft cabin ventilation fan that tested in 2021 were greater than desired. We diagnosed the problem and modified the rotor assembly in 2022 to try and reduce those vibrations. The design changes included a new lighter rotor with a tighter balance tolerance, a new collet to attach the rotor to the motor shaft more securely and repeatably, and a new bracket to center and hold the motor a little better. The redesigned rotor was tested in 2023 and vibrations were significantly reduced. The measured peak vibration was reduced from 4 mm/s second to less than 1 mm/s, corresponding to a reduction from a balance grade G4 to a grade G 0.6.

Fan, Noise, Ventilation↗

Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in) in diameter and 0.223 m (9.00 in) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.0709 m3/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 rpm to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

fan↗

Lessons Learned From Ventilation and Glovebox Flooding Via Overfilling of the Wet Vacuum System in a Plutonium Facility

In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗