Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING↗

Ushering in the New Age of Laboratories: Smart Labs in Practice; Preprint

Ventilation is the first line of defense against airborne hazards produced during research activities in laboratories. A vital component to maintaining healthy, safe, indoor air quality, laboratory ventilation systems are often victim to ineffective operation, posing a risk to an organization's most important asset - the researchers. Furthermore, system inefficiencies can lead to up to 50% wasted energy. By providing a framework to improve the safety and energy efficiency through optimized ventilation and operations, the Smart Labs Toolkit guides laboratory stakeholders through a straight-forward, holistic approach to achieving a dynamic Smart Labs program. A Smart Labs program employs a combination of physical, administrative, and management techniques to plan, assess, optimize, and manage high-performance laboratories. Grounded in the Smart Labs methodology, the National Renewable Energy Laboratory (NREL) implemented a successful Smart Labs program to oversee the design, construction, maintenance, and operations of its laboratories. To accomplish this effort, NREL's key stakeholders created an internal partnership to align NREL's existing laboratories with Smart Labs principles and solidify organizational roles for the safe and efficient operation of laboratory assets. The program provides the groundwork for decarbonization strategies centered around building operation. This paper outlines best practices employed by NREL to develop a cross-cutting Smart Labs team, garner managerial support, and effectively communicate of goals around safety and energy. Strategies include specific Smart Labs best practices, such as implementing a Laboratory Ventilation Risk Assessment - a systematic process for identifying risk due to airborne hazards and informing dynamic, demand-based ventilation to optimize safety and efficiency.

decarbonization↗

Experimental analysis of gas dynamics in the reactor cavity section of a High-Temperature Gas-Cooled Reactor during an accident scenario

Here, this study investigates the behavior of a High-Temperature Gas-Cooled Reactor (HTGR) during a break of the helium pressure boundary event. Understanding the gas dynamics that occur during a break could help develop safety systems that reduce the probability of air entering the reactor core. To achieve this objective, experimental studies were conducted in a scaled-down HTGR experimental facility to provide information on the air-helium gas mixture within the confinement building and the impact of the ventilation system on the helium/air gas concentration following the depressurization event. The study evaluated different configurations, including active ventilation time scales, break sizes, and locations. The analysis of the active ventilation time revealed that a ventilation time of 22 seconds produced positive results, and smaller break sizes resulted in longer depressurization times, which improved the ventilation process. The orientation and elevation of the breaks had little effect on the oxygen concentration in the cavity but did impact the gas velocities.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Are low-cost sensors good enough for IAQ controls?

This study used laboratory testing to evaluate low-cost (about $\$ 200$ US) IAQ monitors that measured PM2.5 to determine if they are suitable for controlling IAQ for ventilation or air cleaning systems. Current Indoor Air Quality (IAQ) standards and approaches to minimizing pollutants depend almost exclusively on using dilution with outdoor air for some generic, continuously generated contaminant (e.g., ASHRAE Standard 62.2-2016). Some standards include measurement of CO 2 (e.g., EN 13779 standard (CEN, 2007) and NEN 8088 (NEN, 2011)) – however this is not because CO 2 itself is a pollutant of concern, but rather because it can be used as an occupancy indicator or as something that correlates with bioeffluents. Ideally, we would like to measure contaminant concentrations directly and ventilate to control their concentration within acceptable limits. This would ensure that concentrations do not got too high (as they can if emission rates exceed our assumptions) and also allow for ventilation reductions, and resulting energy savings, if concentrations are low. Until recently, it was impractical to consider direct contaminant control in residential (and many commercial) spaces due to the high cost and maintenance requirements for monitoring equipment. In the past couple of years low-cost sensors have been developed for some contaminants of concern – the greatest example of which is for particles. These sensors have been incorporated into low-cost (<$250 US) IAQ monitors. Finally, this has opened up the possibility of direct control of ventilation (and filtration systems) by sensing particles. However, it is important to evaluate these monitors to determine if their results are sufficiently good to control a ventilation system.

47 OTHER INSTRUMENTATION↗

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building↗

Comparative experimental study of heat transfer processes in accumulation energy recovery exchangers

In this study, an experimental comparison between three different energy accumulating ceramic heat exchangers for energy recovery in ventilation systems was presented. The units were selected to represent three different approaches on the energy recovery process: honeycomb structure with more accumulation mass (more energy can be stored in one unit)- Unit 1.1, honeycomb structure with lower accumulation mass- Unit 1.2, and a rectangular structure with expanded heat transfer surface- Unit 1.3. The achieved results are useful for the future application of such units in ventilation systems. It was established that all evaluated units demonstrated an acceptable effectiveness of thermal energy recovery from the exhaust air. Their average energy recovery efficiency ranged between 70 % and 80 %, aligning with expected performance benchmarks for regenerative heat exchangers employed in contemporary mechanical ventilation systems. It was also established that the factor which has the highest impact on thermal effectiveness is the heat transfer surface available in the tested heat exchangers. Units with the highest number of channels (i.e., with the highest amount of single channel walls, which can be used for heat transfer) achieve the highest thermal effectiveness. However, higher thermal effectiveness can negatively affect the ventilation potential of the units. Unit 1.3, which was characterized by the highest thermal efficiency, was also characterized by the lowest achievable flow rate. It was also found that the important technical aspect that should be taken into account when analyzing accumulation energy recovery units is also the fluctuation of the supply air temperature. The ability to ensure minimal temperature fluctuations is a significant operational advantage, as it ensures a higher level of safety at lower outside temperatures.

Energy recovery↗

How New Mexico Leveraged a COVID-19 Case Forecasting Model to Preemptively Address the Healthcare Needs of the State: Quantitative Analysis

Prior to the COVID-19 pandemic, US hospitals relied on static projections of future trends for long-term planning and were only beginning to consider forecasting methods for short-term planning of staffing and other resources. With the overwhelming burden imposed by COVID-19 on the health care system, an emergent need exists to accurately forecast hospitalization needs within an actionable timeframe. Our goal was to leverage an existing COVID-19 case and death forecasting tool to generate the expected number of concurrent hospitalizations, occupied intensive care unit (ICU) beds, and in-use ventilators 1 day to 4 weeks in the future for New Mexico and each of its five health regions. We developed a probabilistic model that took as input the number of new COVID-19 cases for New Mexico from Los Alamos National Laboratory’s COVID-19 Forecasts Using Fast Evaluations and Estimation tool, and we used the model to estimate the number of new daily hospital admissions 4 weeks into the future based on current statewide hospitalization rates. The model estimated the number of new admissions that would require an ICU bed or use of a ventilator and then projected the individual lengths of hospital stays based on the resource need. By tracking the lengths of stay through time, we captured the projected simultaneous need for inpatient beds, ICU beds, and ventilators. We used a postprocessing method to adjust the forecasts based on the differences between prior forecasts and the subsequent observed data. Thus, we ensured that our forecasts could reflect a dynamically changing situation on the ground. Forecasts made between September 1 and December 9, 2020, showed variable accuracy across time, health care resource needs, and forecast horizon. Forecasts made in October, when new COVID-19 cases were steadily increasing, had an average accuracy error of 20.0%, while the error in forecasts made in September, a month with low COVID-19 activity, was 39.7%. Across health care use categories, state-level forecasts were more accurate than those at the regional level. Although the accuracy declined as the forecast was projected further into the future, the stated uncertainty of the prediction improved. Forecasts were within 5% of their stated uncertainty at the 50% and 90% prediction intervals at the 3- to 4-week forecast horizon for state-level inpatient and ICU needs. However, uncertainty intervals were too narrow for forecasts of state-level ventilator need and all regional health care resource needs. Real-time forecasting of the burden imposed by a spreading infectious disease is a crucial component of decision support during a public health emergency. Our proposed methodology demonstrated utility in providing near-term forecasts, particularly at the state level. This tool can aid other stakeholders as they face COVID-19 population impacts now and in the future.

60 APPLIED LIFE SCIENCES↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants' chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies: Preprint

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants’ chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Modeling and mitigating airborne pathogen risk factors in school buses

Computational fluid dynamics (CFD) models were developed to simulate the impact of different ventilation scenarios on airborne exposure risks in a 72-passenger school bus. Here, scenarios and factors that were investigated included a moving vs. stationary bus, impacts of a heating unit within the bus, and impacts of alternative ventilation scenarios with different combinations of openings (e.g., windows, door, emergency hatch). Results of the simulations showed that when the bus was stationary, use of the heater increased receptor concentrations unless there was another opening. When the bus was moving, simulations with at least two sets of openings separated from each other in the forward and aft directions produced a through-flow condition that reduced concentrations via dilution from outside air by a factor of ten or more. A single opening in a moving bus generally increased concentrations throughout the cabin due to increased mixing with minimal ventilation. The cumulative exposure risk (time-averaged concentrations) was found to be inversely correlated to the air exchange rate. Stationary and moving-bus scenarios that yielded above ~20 air changes per hour resulted in the lowest cumulative exposures. Recommendations from this study were implemented in new safety and operating procedures by the Albuquerque Public Schools Transportation Center.

60 APPLIED LIFE SCIENCES↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗