Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Investigation of the potential ultralow Q-value β-decay candidates 89 Sr and 139 Ba using Penning trap mass spectrometry

Background: Ultralow Q-value β decays are interesting processes to study with potential applications to nuclear β-decay theory and neutrino physics. While a number of potential ultralow Q-value β-decay candidates exist, improved mass measurements are necessary to determine which of these are energetically allowed. Purpose: To perform precise atomic mass measurements of 89 Y and 139 La. Use these new measurements along with the precisely known atomic masses of 89 Sr and 139 Ba and nuclear energy level data for 89 Y and 139 La to determine if there could be an ultralow Q-value decay branch in the β decay of 89 Sr → 89 Y or 139 Ba → 139 La. Method: High-precision Penning trap mass spectrometry was used to determine the atomic mass of 89 Y and 139 La, from which β-decay Q values for 89 Sr and 139 Ba were obtained. Results: The 89 Sr → 89 Y and 139 Ba → 139 La β-decay Q values were measured to be Q Sr = 1502.20(0.35) keV and Q Ba = 2308.37(0.68) keV. These results were compared to energies of excited states in 89 Y at 1507.4(0.1) keV, and in 139La at 2310(19) keV and 2313(1) keV to determine Q values of -5.20(0.37) keV for the potential ultralow β-decay branch of 89 Sr and -1.6(19.0) keV and -4.6(1.2) keV for those of 139 Ba. Conclusion: The potential ultralow Q-value decay branch of 89 Sr to the 89 Y (3/2 - , 1507.4 keV) state is energetically forbidden and has been ruled out. The potential ultralow Q-value decay branch of 139 Ba to the 2313 keV state in 139 La with unknown J π has also been ruled out at the 4σ level, while more precise energy level data is needed for the 139 La (1/2 + , 2310 keV) state to determine if an ultralow Q-value β-decay branch to this state is energetically allowed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism

As different types of radionuclides (e.g., {sup 131}Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically used for years, such as {sup 125}I and {sup 103}Pd, the sources have been manufactured and marketed by several vendors with different designs and structures. Because of the nature of emission of low energy photons for these radionuclides, energy spectra of the sources are very dependent on their individual designs. Though values of the HVL or the TVL in certain commonly used shielding materials are relatively small for these low energy photon emitting sources, the question remains how the variations in energy spectra affect the HVL (or TVL) values and whether these values can be calculated with a relatively simple method. A more fundamental question is whether a method can be established to derive the HVL (TVL) values for any brachytherapy sources and for different materials in a relatively straightforward fashion. This study was undertaken to answer these questions. Based on energy spectra, a well established semiempirical mass attenuation coefficient computing scheme was utilized to derive the HVL (TVL) values of different materials for different types of brachytherapy sources. The method presented in this study may be useful to estimate HVL (TVL) values of different materials for brachytherapy sources of different designs and containing different radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.

60 APPLIED LIFE SCIENCES↗

Capacity Value of Concentrating Solar Power Plants

This study estimates the capacity value of a concentrating solar power (CSP) plant at a variety of locations within the western United States. This is done by optimizing the operation of the CSP plant and by using the effective load carrying capability (ELCC) metric, which is a standard reliability-based capacity value estimation technique. Although the ELCC metric is the most accurate estimationtechnique, we show that a simpler capacity-factor-based approximation method can closely estimate the ELCC value. Without storage, the capacity value of CSP plants varies widely depending on the year and solar multiple. The average capacity value of plants evaluated ranged from 45%?90% with a solar multiple range of 1.0-1.5. When introducing thermal energy storage (TES), the capacity value ofthe CSP plant is more difficult to estimate since one must account for energy in storage. We apply a capacity-factor-based technique under two different market settings: an energy-only market and an energy and capacity market. Our results show that adding TES to a CSP plant can increase its capacity value significantly at all of the locations. Adding a single hour of TES significantly increasesthe capacity value above the no-TES case, and with four hours of storage or more, the average capacity value at all locations exceeds 90%.

14 SOLAR ENERGY↗

Empirical Indicators of Transmission Value in the Southeast United States

Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Value of Regression Models in Determining Industrial Energy Savings

Determination of industrial facility energy savings is commonly undertaken to comply with legal requirements, meet sustainability goals, and quantify greenhouse gas emissions, cost savings, and as one way to demonstrate energy performance improvement per the requirements of an energy management system standard, such as ISO 50001. At their most basic level, energy savings are determined through a process of accounting for baseline and reporting period energy consumption followed by a calculation of energy savings as the difference in the levels of energy consumption between the two periods. The determination of industrial facility-wide energy savings can be undertaken in a wide variety of ways and in relation to energy performance improvement, energy savings can be expressed as any number of energy performance indicators (EnPIs). Energy savings values will vary depending upon if an absolute, intensity, or regression basis of calculation is selected for use. The use of one of the three basis of energy savings calculation will alter the relevance, meaning, and comparability of the resulting energy savings values To increase consistency in the determination of energy savings values, standards such as the International Performance Measurement and Verification Protocol (IPMVP), ISO 17747 – Determination of Energy Savings in Organization, and the U.S. Department of Energy (U.S. DOE) Superior Energy Performance (SEP) program Measurement and Verification Protocol (SEP M&V Protocol) have been published. Industrial facilities in the United States, Mexico, and Canada are certified to the U.S. DOE SEP program after becoming ISO 50001 certified and verification by a third party of calculated energy savings per the SEP M&V Protocol. This paper discusses some of the different meanings energy savings values will have when calculated by using the three different bases. Additionally, data from five SEP certified industrial facilities are used to calculate energy savings values using the three bases and compared as energy performance improvement percentage (EPI %) values. Discussion of why a large degree in variation in EPI % values are seen for any given set of data is provided. Ultimately, while each energy saving calculation basis has merit and can be used appropriately in its own context, the regression basis is shown to best translates energy savings values into contextualized energy performance improvement values by conveying comparable information regarding operational and behavioural improvements not otherwise observable with the absolute or intensity bases.

Therkelsen, Peter↗

Distributed metadata servers for cluster file systems using shared low latency persistent key-value metadata store

A cluster file system is provided having a plurality of distributed metadata servers with shared access to one or more shared low latency persistent key-value metadata stores. A metadata server comprises an abstract storage interface comprising a software interface module that communicates with at least one shared persistent key-value metadata store providing a key-value interface for persistent storage of key-value metadata. The software interface module provides the key-value metadata to the at least one shared persistent key-value metadata store in a key-value format. The shared persistent key-value metadata store is accessed by a plurality of metadata servers. A metadata request can be processed by a given metadata server independently of other metadata servers in the cluster file system. A distributed metadata storage environment is also disclosed that comprises a plurality of metadata servers having an abstract storage interface to at least one shared persistent key-value metadata store.

97 MATHEMATICS AND COMPUTING↗

Residual value analysis of plug-in vehicles in the United States

Knowledge about the value of used plug-in electric vehicles (PEVs), known as residual value, is critical for potential PEV purchasers, corporations, and governments who wish to consider the lifetime cost effectiveness of PEVs. In this study, we investigate the residual values of PEVs and compare them with those of other vehicle powertrain technologies using the “true market value” data from Edmunds.com, and considering U.S. federal incentives. We define the adjusted retention rate as the ratio between resale value and the manufacturer’s suggested retail price, subtracting incentives. We develop statistical models to quantify the effects of powertrain technologies on residual value while controlling key factors, including vehicle size, brand, and market segments. We find that the long-range high-performance Tesla Model S holds value significantly better than any other vehicle type evaluated, including internal combustion engine vehicles. Hybrid electric vehicles and plugin hybrid electric vehicles are comparable to one another. They hold slightly less value than internal combustion engine vehicles, but significantly more than short-range (<125 miles) battery electric vehicles. However, short-range battery electric vehicles have a faster improvement in 3-year adjusted retention rate than any other powertrain technology from model year 2013–2014. Finally, the other factor that significantly influences adjusted retention rate is the home country of the vehicle manufacturer (e.g., United States, Japan, or Germany).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct determination of the La 138 β -decay Q value using Penning trap mass spectrometry

Background: The understanding and description of forbidden decays provides interesting challenges for nuclear theory. These calculations could help to test underlying nuclear models and interpret experimental data. Purpose: Compare a direct measurement of the 138 La $\beta$-decay $Q$ value with the beta-decay spectrum end-point energy measured by Quarati et al. using LaBr 3 detectors [Appl. Radiat. Isot. 108, 30 (2016)]. Use new precise measurements of the 138 La $\beta$-decay and electron capture (EC) $Q$ values to improve theoretical calculations of the $\beta$-decay spectrum and EC probabilities. Method: High-precision Penning trap mass spectrometry was used to measure cyclotron frequency ratios of 138 La, 138 Ce and 138 Ba ions from which beta-decay and EC Q values for 138 La were obtained.Results: The 138 La beta-decay and EC Q values were measured to be Q$_\beta$ = 1052.42(41) keV and $Q_{EC}$ = 1748.41(34) keV, improving the precision compared to the values obtained in the most recent atomic mass evaluation [Wang, et al., Chin. Phys. C 41, 030003 (2017)] by an order of magnitude. These results are used for improved calculations of the 138 La $\beta$-decay shape factor and EC probabilities. New determinations for the 138 Ce 2EC $Q$ value and the atomic masses of 138 La, 138 Ce, and 138 Ba are also reported. Conclusion: The 138 La $\beta$-decay Q value measured by Quarati et al. is in excellent agreement with our new result, which is an order of magnitude more precise. Uncertainties in the shape factor calculations for 138 La $\beta$-decay using our new $Q$ value are reduced by an order of magnitude. Uncertainties in the EC probability ratios are also reduced and show improved agreement with experimental data.

138La↗

Comparison of Spectroscopic Techniques for Determining the Peroxide Value of 19 Classes of Naturally Aged, Plant-Based Edible Oils

The peroxide value of edible oils is a measure of the degree of oxidation, which directly relates to the freshness of the oil sample. Several studies previously reported in the literature have paired various spectroscopic techniques with multivariate analyses to rapidly determine peroxide values using field portable and process instrumentation; those efforts presented “best-case scenarios” with oils from narrowly defined training and test sets. The purpose of this paper is to evaluate the use of near- and mid-infrared absorption and Raman scattering spectroscopies on oil samples from different oil classes, including seasonal and vendor variations, to determine which measurement technique or combination thereof is best for predicting peroxide values. Following peroxide value assays of each oil class using an established titration-based method, global and global-subset calibration models were constructed from spectroscopic data collected on the 19 oil classes used in this study. Spectra from each optical technique were used to create partial least squares regression calibration models to predict the peroxide value of unknown oil samples. A global peroxide value model based on near-infrared (8 mm optical path length) oil measurements produced the lowest RMSEP (4.9), followed by 24 mm optical path length near infrared (5.1), Raman (6.9) and 50 µm optical path length mid-infrared (7.3). However, it was determined that the Raman RMSEP resulted from chance correlations. Global peroxide value models based on low-level fusion of the NIR (8 and 24 mm optical path length) data and all infrared data produced the same RMSEP of 5.1. Global subset models, based on any of the spectroscopies and olive oil training sets from any class (pure, extra light, extra virgin), all failed to extrapolate to the non-olive oils. However, the near-infrared global subset model built on extra virgin olive oil could extrapolate to test samples from other olive oil classes. This work demonstrates the difficulty of developing a truly global method for determining peroxide value of oils.

36 MATERIALS SCIENCE↗

Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

14 SOLAR ENERGY↗

The effects of storage on the net calorific value of wood pellets

The wood pellet export from Canada to Europe has been increasing steadily in recent years (roughly 1.8 million ton in 2013). Due to distances involved, wood pellets remain in transit and storage for months before their final consumption. The net calorific value determines the price of wood pellet purchase in Europe. There have been concerns about the changes of net calorific values over time. In this study, the effects of storage time, storage configuration, storage temperature, and wood pellet quality on the net calorific value of wood pellets for a period of 6 months were investigated. Storage configurations were open or closed and storage temperatures were 25 °C, 35 °C and 45 °C. Two types of wood pellets used were whitewood and mixed. The results in closed storage indicated that storage time had a positive effect on the net calorific value where the net calorific value increased by 1% to 2% over the storage period. In open storage, the moisture content had the most significant impact on the net calorific value. The net calorific values of the two types of wood pellets were found to be significantly different at p < 0.001. A multivariable linear regression and analyses of variance performed verified the graphical results. Lastly, the authors postulated that the higher energy potential compounds, such as aldehyde and ketone, produced during pellet storage, caused the increase in net calorific values.

09 BIOMASS FUELS↗

Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement

Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann–Whitney U test was used to determine significant differences, with P < 0.05 indicating significance for all tests. Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uplifting winds: The surprisingly positive community-wide impact of wind energy installations on property values

A primary concern of stakeholders when considering a new wind project is the potential negative effects wind turbines may have on home values. Yet, what has been surprisingly overlooked in the literature and general discourse around wind energy is that the well-researched positive economic development and fiscal and amenity benefits of wind energy (e.g., increased tax base, tax revenue, better public services and employment gains) might positively affect jurisdiction-wide housing values. With a focus on school districts in the United States, we compare home values in school districts with wind energy installations, before and after a wind energy installation becomes operational, to home values in other school districts located in the same county but without a wind energy installation to provide some of the first causal evidence on the relationship between wind energy projects and district-wide property values. We find that wind projects lead to economically meaningful increases in district-wide housing values of approximately 3 %, when those values are compared to similar homes located in school districts in same-county without wind energy. The effect is strongly correlated with wind project size. The mechanisms, our research suggests, are likely related to relatively large increases in school district per-pupil revenues and expenditures, which are also correlated with wind project size. We suggest other possible mechanisms for the increased values as well.

Attitudes↗

Seismic monitoring of EGS fracture stimulations at Utah FORGE (Part 1): Time-lapse variations of b-values and Shear-wave Splitting Rates of induced microearthquakes

Characterizing geologic formations near geothermal wells is crucial for efficient extraction of subsurface geothermal energy resources. To monitor effective fracture stimulation of enhanced geothermal systems (EGS), we analyze a catalog of induced microearthquakes to characterize seismicity induced by Phase 2C fracture stimulations of the Utah FORGE project and derive the b-values for 424 induced microearthquakes in three stages of fracture stimulation. Here, we find the time-lapse variations of these b-values. We apply eigenvector rotation and waveform correlation to 3C geophone data to separate fast S 1 and slow S 2 waves, determine their directions, measure their lag time, and calculate the S-wave splitting rate (SSR) for six induced microearthquakes in Stage 1 and 21 in Stage 3. Both SSR values and b-values increase with time. The increase in these values may be related to heavily fractured zones created by fracture stimulations during Stage 2 injections. Large and highly variable SSR values in Stage 3 may reflect heterogeneities in the fracture zones. Time-lapse variations of SSR values and b-values may be one of the most useful approaches to monitoring and characterizing the effectiveness and efficiency of various types of fracture stimulations.

58 GEOSCIENCES↗

Investigating Habitat Value in Support of Contaminant Remediation Decisions: Case Study

Habitat valuation methods were implemented to support remedial decisions for aquatic and terrestrial contaminated sites at the East Tennessee Technology Park (ETTP) on the US Department of Energy (DOE) Oak Ridge Reservation in Oak Ridge, TN, USA. The habitat valuation was undertaken for six contaminated sites: Contractor's Spoil Area, K-901-N Disposal Area, K-770 Scrapyard, K-1007-P1 pond, K-901 pond, and the Mitchell Branch stream. Four of these sites are within the industrial use area of ETTP and two are in the Black Oak Ridge Conservation Easement. These sites represent terrestrial and aquatic habitat for vertebrates, terrestrial habitat for plants, and aquatic habitat for benthic invertebrates. Current and potential future, no-action (no remediation) scenarios were evaluated primarily using existing information. Valuation metrics and scoring criteria were developed in a companion paper, this volume. The habitat valuation consists of extensive narratives, as well as scores for aspects of site use value, site rarity, and use value added from spatial context. Metrics for habitat value were expressed with respect to different spatial scales, depending on data availability. There was significant variation in habitat value among the six sites, among measures for different taxa at a single site, between measures of use and rarity at a single site, and among measures for particular taxa at a single site with respect to different spatial scales. Most sites had aspects of low, medium, and high habitat value. Few high scores for current use value were given. These include: wetland plant communities at all aquatic sites, Lepomid sunfish and waterbirds at 1007-P1 pond, and Lepomid sunfish and amphibians at K-901 pond. Aquatic sites create a high-value ecological corridor for waterbirds, and the Contractor's Spoil Area and possibly the K-901-N Disposal Site have areas that are part of a strong terrestrial ecological corridor. The only example of recent observations of rare species at these sites is the gray bat observed at the K-1007-P1 pond. Some aspects of habitat value are expected to improve under no-action scenarios at a few of the sites. Methods are applicable to other contaminated sites where sufficient ecological data are available for the site and region.

54 ENVIRONMENTAL SCIENCES↗

Effect of pH value on particle morphology and electrochemical properties of LiFePO{sub 4} by hydrothermal method

Graphical abstract: The pH value of system is adjusted in the range of 2.5-8.8 by using dilute sulfuric acid and ammonia water. The results indicated that the particle exhibits acute angle diamond flake-like morphology at pH = 2.5. With increase of pH value, the particle gradually becomes to round flake-like and irregular flake-like morphology. The optimal sample synthesized at pH = 6.4 exhibits discharge capacities of 151.8 mAh g{sup -1} at 0.2 C rate and 129.3 mAh g{sup -1} at 3 C rate. Highlights: {yields} The pH value of solution affects greatly on particle morphology. {yields} The solubility product determined the transition of interphases. {yields} The disorder of atoms in crystal is affected by pH value. {yields} LiFePO{sub 4} with high capacity could be synthesized at slight acid or neutral conditions. -- Abstract: Lithium iron phosphate was prepared by hydrothermal synthesis using LiOH.H{sub 2}O, FeSO{sub 4}.7H{sub 2}O and H{sub 3}PO{sub 4} as raw materials. The effects of pH value of reaction solution on particle morphology and electrochemical property were investigated. The pH value of the reaction solution was adjusted in the range of 2.5-8.8 by dilute sulfuric acid and ammonia water. The samples were characterized by field-emission scanning electronic microscope (FE-SEM), X-ray powder diffraction (XRD), constant-current charge/discharge cycling tests and chemical analysis. The results indicated that the particles exhibited acute angle diamond flake-like morphology at pH = 2.5, and as the pH value increased, the particle became hexagon flake-like, round flake-like and irregular flake-like morphology gradually. The optimal sample synthesized at pH = 6.4 exhibited discharge capacities of 151.8 mAh g{sup -1} at 0.2 C rate and 129.3 mAh g{sup -1} at 3 C rate. It was found that pH value affected the morphologies and properties of the product by means of different crystal growth rates.

36 MATERIALS SCIENCE↗

Evaluation of the 235 U resonance parameters to fit the standard recommended values

A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235 U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235 U interaction in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235 U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235 U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235 U resonance parameters including the recommended standard values as well as new cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗