Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultimate loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Neural Network Prediction of Aluminum-Lithium Weld Strengths from Acoustic Emission Amplitude Data

Acoustic Emission (AE) flaw growth activity was monitored in aluminum-lithium weld specimens from the onset tensile loading to failure. Data on actual ultimate strengths together with AE data from the beginning of loading up to 25 percent of the expected ultimate strength were used to train a backpropagation neural network to predict ultimate strengths. Architecturally, the fully interconnected network consisted of an input layer for the AE amplitude data, a hidden layer to accommodate failure mechanism mapping, and an output layer for ultimate strength prediction. The trained network was the applied to the prediction of ultimate strengths in the remaining six specimens. The worst case prediction error was found to be +2.6 percent.

Hill, Eric v. K.↗

Long-life assessment of graphite epoxy materials for Space Station Freedom pressure vessels

Graphite/epoxy composite overwrapped pressure vessels are being considered for use on Space Station Freedom because of their light weight and high efficiency. These composite pressure vessels weigh roughly one-third of comparable all-metal aluminum pressure vessels, and could result in a 15,000-lb weight saving for the propulsion and fluid management and distribution systems. These vessels must resist failures under sustained pressure loads for crew safety considerations and adequate protection of the space structure during their 30-yr life. Weibull statistical analysis techniques have been applied, and a model developed, for predicting long-term stress-rupture behavior based on published short-term test data on composite strands and pressure vessels. Graphite/epoxy materials are calculated to have a 99.99-percent probability of surviving stress rupture for 30 yr under a sustained load of 50 percent ultimate failure strength. Stress-rupture lifetimes are predicted to increase as the size of the pressure vessels increases in support of the viscoelastic load-transfer mechanism proposed for stress rupture of fiber/epoxy composite materials.

Thomas, Donald A.↗

Perform - A performance optimizing computer program for dynamic systems subject to transient loadings

A description and applications of a computer capability for determining the ultimate optimal behavior of a dynamically loaded structural-mechanical system are presented. This capability provides characteristics of the theoretically best, or limiting, design concept according to response criteria dictated by design requirements. Equations of motion of the system in first or second order form include incompletely specified elements whose characteristics are determined in the optimization of one or more performance indices subject to the response criteria in the form of constraints. The system is subject to deterministic transient inputs, and the computer capability is designed to operate with a large linear programming on-the-shelf software package which performs the desired optimization. The report contains user-oriented program documentation in engineering, problem-oriented form. Applications cover a wide variety of dynamics problems including those associated with such diverse configurations as a missile-silo system, impacting freight cars, and an aircraft ride control system.

Pilkey, W. D.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mass Mitigation in Structural Designs Via Dynamic Properties

Mass Mitigation in Structural Designs Via Dynamic Properties The reported efforts are focused on mitigating unnecessary mass in aerospace hardware via leveraging dynamic strength of materials and the frequency dependency of strain. Analytically predicted dynamic responses of structures are often applied as static loads in stress analyses that ultimately dictate the weight of a structural design. Assuming a dynamic response is a static load and then comparing resulting stress predictions to a static strength property is a long-standing engineering practice. Doing so is known to be, or is assumed to be, conservative. However, little indication of the order of magnitude of embedded conservatism has been identified. NASA/MSFC efforts in 2011, 2019, 2020, and now in 2021 have begun to qualitatively show the order of magnitude of that conservatism. A quick turnaround engineering method is pursued to leverage the subject facets of physics for the purpose of decreasing the weight of flight hardware. Tests performed using simple beams and significant observations are described.

mass mitigation↗

Mass Mitigation in Structural Designs Via Dynamic Properties

The efforts reported here are focused on mitigating unnecessary mass in aerospace hardware. The approach to remove this undesired mass from the design is to leverage both the dynamic strength of materials and the frequency dependency of strain. Analytically predicted dynamic responses of structures are often applied as static loads in stress analyses that ultimately dictate the weight of a structural design. Assuming a dynamic response is a static load and then comparing resulting stress predictions to a static strength property is a long-standing engineering practice. Doing so is known to be, or is assumed to be, conservative. However, little indication of the order of magnitude of embedded conservatism has been identified. NASA/MSFC efforts in 2011, 2019, 2020, and now in 2021 have begun to qualitatively show the order of magnitude of that conservatism. A quick turnaround engineering method is pursued to leverage the subject facets of physics for the purpose of decreasing the weight of flight hardware. Tests performed using simple beams and significant observations are described.

conservative design loads↗

Failure of Laminated Composites at Thickness Discontinuities: An Experimental and Analytical Study

Failure initiation of laminated composites at a thickness discontinuity is studied experimentally with the aid of an optical microscope under combined loading of tension, transverse shear and bending, making use of three- and four-point bending arrangements. Because transverse shear produced relatively small effects in failure initiation results are presented as tension-bending interactions. Two loading frames for three- and four-point bending were designed to apply moment and tension simultaneously to produce failure by generating a ply crack; this initiation was evaluated by finite element analysis using ABAQUS. For cross-plies bounding the interface at the base of the step it is found that a maximum strain criterion applied to the continuing (long) ply describes the failure initiation. Ultimate failure resulted at loads on the order of 25 to 35% higher than those at failure initiation.

Lee, Sangwook↗

Developing a Genetic Variant Calling Pipeline for Quantifying the Complex Mutagenic Load Accumulated in BioNutrients-1 Production Pack Samples

Microorganisms hold great promise for on demand production of labile nutrients and pharmaceuticals as well recycling and in situ resource utilization. The utilization of microorganisms for such tasks on space missions is hindered by the limited data on how microbes respond to spaceflight. For example, the genetic stability of microorganisms, and the genomic engineered traits added to deliver desired functions, over long-term storage in the spacecraft environment is poorly understood. The BioNutrients-1 (BN-1) mission conducted a 5-year study of desiccated storage in Low Earth Orbit (LEO) to evaluate the suitability of eight synthetic biology chassis organisms for long-duration space missions. We are employing high-depth, whole genome sequencing (WGS) to determine the mutagenic load that accumulated during long-term storage. Mutation analysis pipelines are well established for homogenous culture grown from a single colony, but the mutational landscape of the BN-1 samples present a unique analysis challenge, as every cell in the BN-1 samples had a unique genetic journey of DNA damage and repair. Consequently, sequence variants are expected at low allele frequency within samples. To address this genetic complexity, we apply two distinct computational approaches to identify mutations in pre-existing WGS data collected from populations of Chlamydomonas reinhardtii that were exposed to UV mutagenesis and growth in LEO. For reference genome free mutation detection, we utilized DiscoSNP++, which is a de Bruijn graph approach. For reference genome-based mutation detection we utilize GATK for Microbes, which is a Bayesian probabilistic approach. We will benchmark these approaches against the mutations originally identified using CRISP, a method optimized for pooled samples. Ultimately, quantifying the mutation load imposed by storage or growth on the ISS will help identify chassis organisms with both high levels of genome stability and viability, which are desirable traits for implementation of bioproduction in long-duration missions.

SNP↗

In-Plane Cracking Behavior and Ultimate Strength for 2D Woven and Braided Melt-Infiltrated SiC/SiC Composites Tensile Loaded in Off-Axis Fiber Directions

The tensile mechanical properties of ceramic matrix composites (CMC) in directions off the primary axes of the reinforcing fibers are important for architectural design of CMC components that are subjected to multi-axial stress states. In this study, 2D-woven melt-infiltrated (MI) SiC/SiC composite panels with balanced fiber content in the 0 degree and 90 degree directions were tensile loaded in-plane in the 0 degree direction and at 45 degree to this direction. In addition, a 2D triaxially-braided MI composite panel with balanced fiber content in the plus or minus 67 degree bias directions and reduced fiber content in the axial direction was tensile loaded perpendicular to the axial direction tows (i.e., 23 degrees from the bias fibers). Stress-strain behavior, acoustic emission, and optical microscopy were used to quantify stress-dependent matrix cracking and ultimate strength in the panels. It was observed that both off-axis loaded panels displayed higher composite onset stresses for through-thickness matrix cracking than the 2D-woven 0/90 panels loaded in the primary 0 degree direction. These improvements for off-axis cracking strength can in part be attributed to higher effective fiber fractions in the loading direction, which in turn reduces internal stresses on critical matrix flaws for a given composite stress. Also for the 0/90 panel loaded in the 45 degree direction, an improved distribution of matrix flaws existed due to the absence of fiber tows perpendicular to the loading direction. In addition, for the +67/0/-67 braided panel, the axial tows perpendicular to the loading direction were not only low in volume fraction, but were also were well separated from one another. Both off-axis oriented panels also showed relatively good ultimate tensile strength when compared to other off-axis oriented composites in the literature, both on an absolute strength basis as well as when normalized by the average fiber strength within the composites. Initial implications are discussed for constituent and architecture design to improve the directional cracking of SiC/SiC CMC components with MI matrices.

Morscher, Gregory N.↗

Importance of anisotropy on design of compression-loaded composite corrugated panels

An investigation is conducted of the importance of anisotropic terms in the design of composite corrugated panels, for a range of axial compressive load intensities. The two panel configurations treated were panels with tailored laminates and panels with a continuous laminate; both are of interest to aircraft designers and prone to anisotropic effects which are of as-yet undetermined extent. The importance of the anisotropic terms is measured by the difference between the design load and the buckling load obtained from the ultimate structural analysis.

Gurdal, Zafer↗

Stiffened Carbon/Carbon Compression Panels

Panels with integral stiffeners made with woven fabric in two-dimensional, cross-ply layups. Local skin buckling does not cause collapse of panels, and ultimate failure occurs at loads 10 to 20 percent above buckling loads. For panels subjected to in-plane loading, separation of stiffeners from panel skins was not problem. High-temperature structural applications on advanced aircraft and spacecraft include leading edges, fairings, and control surfaces.

Sawyer, James W.↗

Elevated temperature biaxial fatigue

A 3 year experimental program for studying elevated temperature biaxial fatigue of a nickel based alloy Hastelloy-X has been completed. A new high temperature fatigue test facility with unique capabilities has been developed. Effort was directed toward understanding multiaxial fatigue and correlating the experimental data to the existing theories of fatigue failure. The difficult task of predicting fatigue lives for nonproportional loading was used as an ultimate test for various life prediction methods being considered. The primary means of reaching improved understanding were through several critical nonproportional loading experiments. The direction of cracking observed on failed specimens was also recorded and used to guide the development of the theory. Cyclic deformation responses were permanently recorded digitally during each test. It was discovered that the cracking mode switched from primarily cracking on the maximum shear planes at room temperature to cracking on the maximum normal strain planes at 649 C. In contrast to some other metals, loading path in nonproportional loading had little effect on fatigue lives. Strain rate had a small effect on fatigue lives at 649 C. Of the various correlating parameters the modified plastic work and octahedral shear stress were the most successful.

Jordan, E. H.↗

Elevated temperature biaxial fatigue

A three year experimental program for studying elevated temperature biaxial fatigue of a nickel based alloy Hastelloy-X has been completed. A new high temperature fatigue test facility with unique capabilities has been developed. Effort was directed toward understanding multiaxial fatigue and correlating the experimental data to the existing theories of fatigue failure. The difficult task of predicting fatigue lives for non-proportional loading was used as an ultimate test for various life prediction methods being considered. The primary means of reaching improved undertanding were through several critical non-proportional loading experiments. It was discovered that the cracking mode switched from primarily cracking on the maximum shear planes at room temperature to cracking on the maximum normal strain planes at 649 C.

Jordan, E. H.↗

Micromechanics Modeling of Textiles for Re-Entry Parachute Applications

Recent flight test projects and NASA missions have highlighted the challenges associated with accurately and efficiently modeling the behavior of parachute deployment systems needed for parachute design. Moreover, parachute deployment has been identified as one of the higher risk components for such missions. The analysis of textile fabrics used for atmospheric entry is inherently complex due to the multiple scales present in the fabric structure, including individual fiber filaments at the microscale, yarn bundles of fibers at the mesoscale, and the overall woven fabric at the macroscale. Computational tools for simulating fabric behavior must be able to account for the different mechanisms present at each scale without sacrificing computational efficiency. This work examines the generalized multiscale method of cells micromechanics theory, which has previously been used for the analysis of reinforced composite structures, to unreinforced textile fabrics. Modifications to the existing composite multiscale framework, implemented in NASA’s Multiscale Analysis Tool (NASMAT), include the specific mechanics unique to unreinforced textile fabrics, and overcoming the assumptions of a fixed fiber angle. It looks to assess the feasibility of using the NASMAT tool for efficient prediction of the response of unreinforced fabrics to loading such that it can ultimately be applied to fluid structure interaction tools for the prediction of parachute deployment systems. In this work, fabric behavior is simulated in NASMAT through homogenization of a triply periodic repeating unit cell, where the geometry of the subcells can change as a function of loading to represent the relative rotation and uncrimping that can occur in fabric tows. Predictions from the amended NASMAT code are compared to experimental data for uniaxial and off-axis tension to verify the ability of the code to incorporate lower-scale mechanics in prediction of unreinforced fabrics under loading.

Micromechanics↗

Bearing Tests of Magnesium-alloy Sheet

Bearing tests of AM-3S, AM-52S, and AM-C57S magnesium-alloy sheet in various thicknesses and tempers were made. Bearing yield and ultimate strengths were determined and compared for various edge distances and for various ratios of loading-pin diameter to sheet thickness. Tensile strengths were determined and ratios of average bearing yield and ultimate strength to tensile strength are given. The results of the tests indicated that ultimate bearing strengths increased with edge distances up to 1.5 to 2 times the diameter of the loading pin; that ultimate bearing strengths are a function of the ratio of pin diameter to sheet thickness; and that these properties are effected only slightly by increases in edge distance greater than 1.5 diameters.

Sharp, W H↗

Evaluation of hybrid composite materials in cylindrical specimen geometries

Static and fatigue properties of three composite materials and hybrids were examined. The materials investigated were graphite/epoxy, S-glass/epoxy, PRD-49 (Kevlar 49)/epoxy, and hybrids in angle-ply configurations. A new type of edgeless cylindrical specimen was developed. It is a flattened tube with two flat sides connected by curved sections and it is handled much like the standard flat coupon. Special specimen fabrication, tabbing, and tab region reinforcing techniques were developed. Axial modulus, Poisson's ratio, strength, and ultimate strain were obtained under static loading from flattened tube specimens of nine laminate configurations. In the case of graphite/epoxy the tubular specimens appeared to yield somewhat higher strength and ultimate strain values than flat specimens. Tensile fatigue tests were conducted with all nine types of specimens and S-N curves obtained. Specimens surviving 10 million cycles of tensile loading were subsequently tested statically to failure to determine residual properties.

Liber, T.↗

Analysis and Tests of Reinforced Carbon-Epoxy/Foam-Core Sandwich Panels with Cutouts

The results of a study of a low-cost structurally efficient minimum-gage shear-panel design that can be used in light helicopters are presented. The shear-panel design is based on an integrally stiffened syntactic-foam stabilized-skin with an all-bias-ply tape construction for stabilized-skin concept with an all-bias-ply tape construction for the skins. This sandwich concept is an economical way to increase the panel bending stiffness weight penalty. The panels considered in the study were designed to be buckling resistant up to 100 lbs/in. of shear load and to have an ultimate strength of 300 lbs/in. The panel concept uses unidirectional carbon-epoxy tape on a syntactic adhesive as a stiffener that is co-cured with the skin and is an effective concept for improving panel buckling strength. The panel concept also uses pultruded carbon-epoxy rods embedded in a syntactic adhesive and over-wrapped with a bias-ply carbon-epoxy tape to form a reinforcing beam which is an effective method for redistributing load around rectangular cutout. The buckling strength of the reinforced panels is 83 to 90 percent of the predicted buckling strength based on a linear buckling analysis. The maximum experimental deflection exceeds the maximum deflection predicted by a nonlinear analysis by approximately one panel thickness. The failure strength of the reinforced panels was two and a half to seven times of the buckling strength. This efficient shear-panel design concept exceeds the required ultimate strength requirement of 300 lbs/in by more than 100 percent.

Baker, Donald J.↗

Translating Fundamental Insights into Ag-Based Bimetallic Electrocatalysts to Anion-Exchange Membrane Fuel Cells

To address challenges of high costs and scalability for fuel cells, it is essential to develop af-fordable and earth-abundant materials that are Pt-group-metal (PGM)-free. Recent advance-ments in PGM-free electrocatalysis for the oxygen reduction reaction (ORR) in alkaline media show that high catalyst loadings are needed to achieve high reaction rates; however, there are associated mass transport limitations. To address this issue, we develop low-loading ionomer-less Ag-bimetallic thin films by alloying with 3d block elements or Sn. We bridge knowledge from fundamental rotating disk electrode (RDE) studies to gas-diffusion cathodes in high-temperature anion-exchange membrane fuel cells (HT-AEMFCs), resulting in high-activity ORR catalysis and peak power densities up to 1.2 W cm-² geo for the Ag-Sn and Ag-Co alloys. Here, experimental post-characterization and theoretical calculations reveal small Co or Sn oxide nano-islands on Ag as likely active sites enhancing ORR activity, ultimately offering these low-loading PGM-free ORR materials as a viable path towards sustainable energy conversion.

Catalysts↗