Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “two phase flow boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Flow boiling of R134a in a large surface area microchannel array for high-flux laser diode cooling

Packaging high average power laser diode arrays that generate heat at an area average flux in excess of 1 kW·cm -2 is a significant engineering challenge. While liquid microchannel coolers have demonstrated up to 11.9 kW·cm -2 , two-phase microchannel array coolers have not achieved 1 kW cm -2 due to critical heat flux and flow instabilities. In the current study, flow boiling heat transfer was characterized by a 1 &times; 10 mm heated zone centered over a 5 &times; 10 mm array of 125 very small channels (45 &times; 200 &mu;m) with R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio. A test facility was used to characterize the heat transfer performance of boiling R134a over a range of saturation temperatures (15&deg;C to 25&deg;C), mass fluxes (735-2230 kg·m -2 ·s -1 ), and heat duties (< 110.3 W). During the tests, the calculated outlet vapor quality exceeded 61%, and the base heat flux at the heater reached a maximum of 1.1 kW·cm -2 . The resulting average experimental flow boiling heat transfer coefficients are found to be as large a 13.4 kW·m -2 ·K -1 over the approximately 3 mm two-phase region, with an average uncertainty of ± 2.72%. A substantial amount of heat was spread downstream via the low thermal resistance silicon floor. Specifically, between 29.5% and 55.1% of the heat dissipated in the two-phase region was dissipated over the heater. Finally, the remaining heat dissipated in the two-phase region was dissipated in the 2 mm of channel downstream of the heater. This suggests that heat spreading from the hotspot played a vital role in dissipating the heat load.

42 ENGINEERING↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Improved Method For Experiments In Vertical-Flow Boiling

Improved method of experimentation in boiling and adiabatic vertical flows provides for simultaneous determination of two-phase frictional pressure drop and vapor-volume fraction. Gravitational pressure drop determined from precise measurements of temperatures and differential pressures in conjunction with quick closure of valves.

Klausner, J. F.↗

Bubble Generation in a Flowing Liquid Medium and Resulting Two-Phase Flow in Microgravity

An experimental and theoretical research program is described herein to study bubble generation in a liquid flow in a pipe under reduced gravity conditions. The objective of the work is to study the bubble size and frequency of the generation and the resulting two-phase flow but it also concerns the fluid mechanical aspects of boiling in forced flow in microgravity. By injecting a gas into a liquid flow in a pipe through a small hole in the pipe wall we will investigate how the bubble expands and detaches from the wall, without involving the complexities of boiling. The experiments will be conducted both under isothermal conditions and with heat transfer from the wall. In the experiments with heat transfer the effect of thermocapillarity on the bubble formation and detachment will be the main subject.

Kamotani, Yasuhiro↗

Demonstration of fully coupled simplified extended station black-out accident simulation with RELAP-7

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The RELAP-7 code develop-ment effort started in October of 2011 and by the end of the second development year, a number of physical components with simplified two phase flow capability have been de-veloped to support the simplified boiling water reactor (BWR) extended station blackout (SBO) analyses. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for the safety relief valve (SRV), the reactor core isolation cooling (RCIC) system, and the wet well. Three scenar-ios for the SBO simulations have been considered. Since RELAP-7 is not a severe acci-dent analysis code, the simulation stops when fuel clad temperature reaches damage point. Scenario I represents an extreme station blackout accident without any external cooling and cooling water injection. The system pressure is controlled by automatically releasing steam through SRVs. Scenario II includes the RCIC system but without SRV. The RCIC system is fully coupled with the reactor primary system and all the major components are dynamically simulated. The third scenario includes both the RCIC system and the SRV to provide a more realistic simulation. This paper will describe the major models and dis-cuss the results for the three scenarios. The RELAP-7 simulations for the three simplified SBO scenarios show the importance of dynamically simulating the SRVs, the RCIC sys-tem, and the wet well system to the reactor safety during extended SBO accidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced two-phase subchannel method via non-linear iteration

A fast-running, robust two-phase flow, sub-channel model is presented based on non-linear solution of the steady-state subchannel fluid flow equations. The drift-flux model solves for conservation of liquid and vapor mass, mixture energy, and axial and transverse mixture momentum as part of an efficient planar marching scheme and nonlinear, nested outer and inner iteration. Here, models based on mechanistic subcooled boiling, two-phase turbulent void mixing, and drift are included. Solution verification and mesh convergence studies were performed for modern GE 10 × 10 fuel geometry and are shown to have excellent convergence behavior. Run time performance for a 50 axial mesh model showed 2.2 seconds on a single CPU core to tightly converge all 3D distributions (flow, void, pressure) for the GE 10 × 10 fuel geometry, supporting its efficient use within the Virtual Environment for Reactor Applications boiling water reactor framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

effect of ambient pressure on the behavior of single-component fuels in a gasoline multi-hole injector

The injection characteristics of neat ethanol and pure isooctane are studied under different ambient pressure and temperature conditions. Injection underflash-boiling conditions can enhance liquid atomization and evaporation, providing the possibility of improvement in the fuel/air mixing. These superheated conditions often introduce phenomena that are not taken into account in the standard modeling of sprays for engine applications. The present work proposes a numerical investigation of the behavior of Engine Combustion Network's 8-hole spray-G injector, starting at the subcooled nominal condition and reducing the ambient pressure at constant low temperature to reach the flare flash-boiling condition. To initialize the properties of the injected fuel, the flow in the nozzle is simulated with a Eulerian approach, handling the two phases with a mixture model and the phase change, due to cavitation and flash boiling, with the Homogenous Relaxation Model. A map of the mixture's kinematic and thermal behavior is obtained at the interface between the injector and the chamber to initialize the Lagrangian simulations. A literature-based vaporization model is implemented to obtain the proper description of the characteristic features of a multi-hole spray under super-heated conditions, like plume-plume interaction. The numerical representation of the spray is validated in terms of penetration and radial spreading on DBI images, reproducing the light attenuation profiles caused by the presence of the liquid spray. Simulations show that coupled nozzle flow and spray calculations capture the spray morphology and shape better compared to calculations performed without considering the nozzle flow simulation details, especially under flare flash conditions.

Nocivelli, Lorenzo↗

Development of Electrical Capacitance Sensors for Accident Tolerant Fuel (ATF) Testing at the Transient Reactor Test (TREAT) Facility

A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Boiling Flow in a Helical Coil Using a Homogeneous Equilibrium Model with the Nek-2P CFD Code

Recent developments in the field of nuclear energy have lead to an increased interest in the design of helically coiled steam generators. In particular, their compact size, and high heat transfer rates make them ideal for small modular reactors. This has lead to a renewed effort to investigate the characteristics of fluid flow and heat transfer in and around helical coils both numerically and experimentally. The focus of this work is on the development of a consistent modeling, formulation, and simulation framework for boiling flows in helical coils using the highly scalable Nek-2P CFD code. As a first step, two phase flow is accounted for using a homogeneous equilibrium model. Results for both single and multiphase flows are compared to results obtained from Star-CCM+. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling of internal and near-nozzle flow for a GDI fuel injector

A numerical study of two-phase flow inside the nozzle holes and the issuing spray jets for a multi-hole direct injection gasoline injector has been presented in this work. The injector geometry is representative of the Spray G nozzle, an eight-hole counterbore injector, from the Engine Combustion Network (ECN). Simulations have been carried out for a fixed needle lift. Effects of turbulence, compressibility and non-condensable gases have been considered in this work. Standard k -ε turbulence model has been used to model the turbulence. Homogeneous Relaxation Model (HRM) coupled with Volume of Fluid (VOF) approach has been utilized to capture the phase change phenomena inside and outside the injector nozzle. Three different boundary conditions for the outlet domain have been imposed to examine non-flashing and evaporative, non-flashing and non-evaporative and flashing conditions. Noticeable hole-to-hole variations have been observed in terms of mass flow rates for all the holes under all the operating conditions considered in this study. Inside the nozzle holes mild cavitation-like and in the near-nozzle region flash boiling phenomena have been predicted when liquid fuel is subjected to superheated ambiance. Under favorable conditions considerable flashing has been observed in the near-nozzle regions. An enormous volume is occupied by the gasoline vapor, stantial computational cost. Volume-averaging instead of mass-averaging is observed to be more effective, especially for finer mesh resolutions.

42 ENGINEERING↗

Assessment of the Subchannel Code CTF for Single- and Two-Phase Flows

As part of the Consortium for Advanced Simulation of Light Water Reactors, the subchannel code CTF is being used for single-phase and two-phase flow analysis under light water reactor operating conditions. Accurate determination of flow distribution, pressure drop, and void content is crucial for predicting margins to thermal crisis and ensuring more efficient plant performance. In preparation for the intended applications, CTF has been validated against data from experimental facilities comprising the General Electric (GE) 3 × 3 bundle, the boiling water reactor full-size fine-mesh bundle tests (BFBTs), the Risø tube, and the pressurized water reactor subchannel and bundle tests (PSBTs). Meanwhile, the licensed, well-recognized subchannel code VIPRE-01 was used to generate a baseline set of simulations for the targeted tests and solution parameters were compared to the CTF results.The flow split verification problem and single-phase GE 3 × 3 results are essentially in perfect agreement between the two codes. For the two-phase GE 3 × 3 cases, flow and quality discrepancies arise in the annular-mist flow regime, yet significant improvement is observed in CTF when void drift and two-phase turbulent mixing enhancement are considered. The BFBT pressure drop benchmark shows close agreement between predicted and measured results in general, although considerable overprediction by CTF is observed at relatively high void locations of the facility. This overestimation tendency is confirmed by the Risø cases. While overall statistics are satisfactory, both BFBT and PSBT bubbly-to-churn flow void contents are markedly overpredicted by CTF.The issues with two-phase closures such as turbulent mixing, interfacial and wall friction, and subcooled boiling heat transfer need to be addressed. As a result, preliminary sensitivity studies are presented herein, but more advanced models and code stability analysis require further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of a Smoothed Particle Hydrodynamics Method for Thin Film on Textured Surfaces

A large number of previous studies suggest that the behavior of the near-wall liquid micro-layer plays a key role in boiling heat transfer and boiling crisis; see examples. The thin liquid layer interacts with heater surface and 'external' two-phase flow. The net effects of these interactions define the micro-hydrodynamics that leads to dryout. As a result, a good understanding of the thin-layer hydrodynamics is significant for the accurate prediction of CHF. Recently, with the advent of nanotechnology including micro-scale manufacturing, it becomes possible to perform high heat-flux boiling experiments with controlled surface conditions. Although many reports show rich observations about the effects of surface characteristics on CHF, physical mechanisms remain not fully understood. In order to have better understanding of the above phenomena, several computational models are developed, ranging from the lubrication theory to CFD methods. The former models are limited to one-dimensional formulation and unable to deal with the dry-out phenomena. It turns out that CFD methods have a greater potential for the mechanistic study of boiling. Towards the study objective, a particle-based CFD method called Smoothed Particle Hydrodynamics (SPH) is adopted. SPH is a Lagrangian particle method for solving systems of partial differential equations. Originally SPH is proposed for fluid dynamics in the context of astrophysical problems. Because mass and density are introduced during the particle approximation, SPH is also applied in fluid dynamic problems, where mass and density are important parameters to determine, without mass loss (a limitation of interface capturing schemes in mesh-based methods). Besides, geometrically complex and/or dynamic boundaries and interfaces can be handled without undue difficulty in SPH. Currently, most SPH simulations focus on large-scale scenarios (meter scale), like flooding and solitary wave. Also some works have been done with SPH in pore-scale. As for micro- or nano-scale simulation, people usually apply Dissipative Particle Dynamics (DPD) and Molecular Dynamics (MD) for particle-based simulation. Almost no work has been done on micro-scale with SPH, so assessments are needed to investigate the capability of SPH in application of micro-hydrodynamics. The Phenomena Identification and Ranking Table (PIRT) is applied to align application's technical requirements with associated physics and materials, models, simulation code capabilities and verification, validation and uncertainty quantification activities. The figures of merit are determined as: (1) Timing of micro-layer rewetting dry surface; (2) Effects of surface features. The corresponding key phenomena are determined as: (1) Hydrodynamics; (2) Interface Dynamics; (3) Energy; (4) Surface Effect. This study deals with isothermal scenario and no energy term is considered. Based on the current needs, a new SPH package, Micro-SPH, is compiled based on SPHysics with surface tension and wettability built in. Test cases are performed with Micro-SPH to assess the capability of SPH to each phenomenon identified. NEUTRINO with incompressible SPH solver is employed to investigate micro-fluid dynamics on a surface with uniformly distributed cylindrical pillars for application purposes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5 Model of a Two-phase ThermoSyphon Experimental Facility for Fuels and Materials Irradiation

The High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) does not have a separate materials-irradiation flow loop and requires most materials and all fuel experiments to be placed inside a containment. This is necessary to ensure that internal contaminants such as fission products cannot be released into the primary coolant. As part of the safety basis justification, HFIR also requires that all experiments be able to withstand various accident conditions (e.g., loss of coolant) without generating vapor bubbles on the surface of the experiment in the primary coolant. As with any parallel flow system, HFIR is vulnerable to flow excursion events when vapor is generated in one of those flow paths. The effects of these requirements are to artificially increase experiment temperatures by introducing a barrier between the experimental materials and the HFIR coolant and to reduce experiment heat loads to ensure boiling doesn t occur. A new experimental facility for materials irradiation and testing in the HFIR is currently being developed to overcome these limitations. The new facility is unique in that it will have its own internal cooling flow totally independent of the reactor primary coolant and boiling is permitted. The reactor primary coolant will cool the outside of this facility without contacting the materials inside. The ThermoSyphon Test Loop (TSTL), a full scale prototype of the proposed irradiation facility to be tested outside the reactor, is being designed and fabricated (Ref. 1). The TSTL is a closed system working as a two-phase thermosyphon. A schematic is shown in Fig. 1. The bottom central part is the boiler/evaporator and contains three electric heaters. The vapor generated by the heaters will rise and be condensed in the upper condenser, the condensate will drain down the side walls and be circulated via a downcomer back into the bottom of the boiler. An external flow system provides coolant that simulates the HFIR primary coolant. The two-phase flow code RELAP5-3D (Ref. 2) is the main tool employed in this design. The model has multiple challenges: boiling, condensation and natural convection flows need to be modeled accurately.

RELAP5 ThermoSyphon fuels irradiation↗

Two-Phase Turbulence Statistics from High Fidelity Dispersed Droplet Flow Simulations in a Pressurized Water Reactor (PWR) Sub-Channel with Mixing Vanes

In the dispersed flow film boiling regime (DFFB), which exists under post-LOCA (loss-of-coolant accident) conditions in pressurized water reactors (PWRs), there is a complex interplay between droplet dynamics and turbulence in the surrounding steam. Experiments have accredited particular significance to droplet collision with the spacer-grids and mixing vane structures and their consequent positive feedback to the heat transfer recorded in the immediate downstream vicinity. Enabled by high-performance computing (HPC) systems and a massively parallel finite element-based flow solver—PHASTA (Parallel Hierarchic Adaptive Stabilized Transient Analysis)—this work presents high fidelity interface capturing, two-phase, adiabatic simulations in a PWR sub-channel with spacer grids and mixing vanes. Selected flow conditions for the simulations are informed by the experimental data found in the literature, including the steam Reynolds number and collision Weber number (Wec={40,80}), and are characteristic of the DFFB regime. Data were collected from the simulations at an unprecedented resolution, which provides detailed insights into the continuous phase turbulence statistics, highlighting the effects of the presence of droplets and the comparative effect of different Weber numbers on turbulence in the surrounding steam. Further, axial evolution of droplet dynamics was analyzed through cross-sectionally averaged quantities, including droplet volume, surface area and Sauter mean diameter (SMD). The downstream SMD values agree well with the existing empirical correlations for the selected range of Wec. The high-resolution data repository from the simulations herein is expected to be of significance to guide model development for system-level thermal hydraulic codes.

Saini, Nadish↗

Time-resolved measurements of liquid–vapor thermal interactions throughout the full life-cycle of sliding bubbles at subcooled flow boiling conditions

The local thermal response of the liquid phase to the presence of sliding bubbles was measured with an infrared camera in subcooled flow-boiling conditions. These measurements were complemented with two high-speed cameras to capture the corresponding bubbles’ dynamics. The liquid–vapor interactions were captured in detail over the full life-cycle of sliding bubbles. Four distinctive phases for the bubble life-cycle were identified: A) Spherical bubble growth with strong attachment, B) Deformed bubble growth with weak attachment, C) Detachment with hot liquid quenching, and D) Cold liquid quenching. Here, to the best of the authors’ knowledge, it is the first time that the “detachment with hot liquid quenching phase has been observed. This phase is characterized by a “hot” thermal footprint during the bubble detachment process. It is believed that this footprint is constituted partially from hot liquid released during the condensation of the recently detached bubble, and from released hot fluid previously collected by the bubble during sliding. In addition, this work reveals that using traditional high-speed visualization techniques (side-view camera only) can lead to an underestimation of approximately 40% of the actual bubble–wall contact diameter (dc) which was inferred from the infrared camera measurements.

42 ENGINEERING↗

Definition of two-phase flow behaviors for spacecraft design

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. A boiling and condensing experiment was built in which R-12 was used as the working fluid. A two-phase pump was used to circulate a freon mixture and allow separate measurements of the vapor and liquid flow streams. The experimental package was flown five times aboard the NASA KC-135 aircraft which simulates zero-g conditions by its parabolic flight trajectory. Test conditions included stratified and annual flow regimes in 1-g which became bubbly, slug, or annular flow regimes on 0-g. A portion of this work is the analysis of adiabatic flow regimes. The superficial velocities of liquid and vapor have been obtained from the measured flow rates and are presented along with the observed flow regimes.

Reinarts, Thomas R.↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗