Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmissive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Evaluation of Power Transmission Lines Hardening Scenarios Using a Machine Learning Approach

The power transmission infrastructure is vulnerable to extreme weather events, particularly hurricanes and tropical storms. A recent example is the damage caused by Hurricane Maria (H-Maria) in the archipelago of Puerto Rico in September 2017, where major failures in the transmission infrastructure led to a total blackout. Numerous studies have been conducted to examine strategies to strengthen the transmission system, including burying the power lines underground or increasing the frequency of tree trimming. However, few studies focus on the direct hardening of the transmission towers to accomplish an increase in resiliency. This machine learning-based study fills this need by analyzing three direct hardening scenarios and determining the effectiveness of these changes in the context of H-Maria. A methodology for estimating transmission tower damage is presented here in this study as well as an analysis of impact of replacing structures with a high failure rate with more resilient ones. We found the steel self-support-pole to be the best replacement option for the towers with high failure rate. Furthermore, the third hardening scenario, where all wooden poles were replaced, exhibited a maximum reduction in damaged towers in a single line of 66% while lowering the mean number of damaged towers per line by 10%.

54 ENVIRONMENTAL SCIENCES↗

Regional Relative Risk, a Physics-Based Metric for Characterizing Airborne Infectious Disease Transmission

Airborne infectious disease transmission events occur over a wide range of spatial scales and can be an important means of disease transmission. Physics- and biology-based models can assist in predicting airborne transmission events, overall disease incidence, and disease control strategy efficacy. We describe a new theory that extends current approaches for the case in which an individual is infected by a single airborne particle, including the scenario in which numerous infectious particles are present in the air but only one causes infection. A single infectious particle can contain more than one pathogenic microorganism and be physically larger than the pathogen itself. This approach allows robust relative risk estimates even when there is wide variation in (i) individual exposures and (ii) the individual response to that exposure (the pathogen dose-response function can take any mathematical form and vary by individual). Based on this theory, we propose the regional relative risk—a new metric, distinct from the traditional relative risk metric, that compares the risk between two regions. In theory, these regions can range from individual rooms to large geographic areas. In this paper, we apply the regional relative risk metric to outdoor disease transmission events over spatial scales ranging from 50 m to 20 km, demonstrating that in many common cases minimal input information is required to use the metric. Also, we demonstrate that the model predictions are consistent with data from prior outbreaks. Future efforts could apply and validate this theory for other spatial scales, such as transmission within indoor environments. This work provides context for (i) the initial stages of an airborne disease outbreak and (ii) larger-scale disease spread, including unexpected low-probability disease “sparks” that potentially affect remote populations, a key practical issue in controlling airborne disease outbreaks.

54 ENVIRONMENTAL SCIENCES↗

Transmission estimation at the quantum Cramér-Rao bound with macroscopic quantum light

The field of quantum metrology seeks to apply quantum techniques and/or resources to classical sensing approaches with the goal of enhancing the precision in the estimation of a parameter beyond what can be achieved with classical resources. Theoretically, the fundamental minimum uncertainty in the estimation of a parameter for a given probing state is bounded by the quantum Cramér-Rao bound. From a practical perspective, it is necessary to find physical measurements that can saturate this fundamental limit and to show experimentally that it is possible to perform measurements with the required precision to do so. Here we perform experiments that saturate the quantum Cramér-Rao bound for transmission estimation over a wide range of transmissions when probing the system under study with a continuous wave bright two-mode squeezed state. To properly take into account the imperfections in the generation of the quantum state, we extend our previous theoretical results to incorporate the measured properties of the generated quantum state. For our largest transmission level of 84%, we show a 62% reduction over the optimal classical protocol in the variance in transmission estimation when probing with a bright two-mode squeezed state with -8 dB of intensity-difference squeezing. Given that transmission estimation is an integral part of many sensing protocols, such as plasmonic sensing, spectroscopy, calibration of the quantum efficiency of detectors, etc., the results presented promise to have a significant impact on a number of applications in various fields of research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Hubble Space Telescope's Near-UV and Optical Transmission Spectrum of Earth as an Exoplanet

We observed the 2019 January total lunar eclipse with the Hubble Space Telescope’s STIS spectrograph to obtain the first near-UV (1700–3200 Å) observation of Earth as a transiting exoplanet. The observatories and instruments that will be able to perform transmission spectroscopy of exo-Earths are beginning to be planned, and characterizing the transmission spectrum of Earth is vital to ensuring that key spectral features (e.g., ozone, or O{sub 3}) are appropriately captured in mission concept studies. O{sub 3} is photochemically produced from O{sub 2}, a product of the dominant metabolism on Earth today, and it will be sought in future observations as critical evidence for life on exoplanets. Ground-based observations of lunar eclipses have provided the Earth’s transmission spectrum at optical and near-IR wavelengths, but the strongest O{sub 3} signatures are in the near-UV. We describe the observations and methods used to extract a transmission spectrum from Hubble lunar eclipse spectra, and identify spectral features of O{sub 3} and Rayleigh scattering in the 3000–5500 Å region in Earth’s transmission spectrum by comparing to Earth models that include refraction effects in the terrestrial atmosphere during a lunar eclipse. Our near-UV spectra are featureless, a consequence of missing the narrow time span during the eclipse when near-UV sunlight is not completely attenuated through Earth’s atmosphere due to extremely strong O{sub 3} absorption and when sunlight is transmitted to the lunar surface at altitudes where it passes through the O{sub 3} layer rather than above it.

79 ASTRONOMY AND ASTROPHYSICS↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking

As distributed energy resources (DERs) play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled HELICS-based co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. These results are compared to the same distribution system run without co-simulation using a fixed feed-in voltage. Results show that even without advanced voltage controls, the feed-in voltage response when coupled to the transmission system results a lower level of voltage excursions, suggesting the importance of using this type of realistic, tightly coupled, transmission and distribution co-simulation when assessing DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Cyber-Physical Events Emulation Based Transmission and Distribution Co-Simulation for Situation Awareness and Grid Anomaly (SAGA) Detection: Preprint

Energy management of transmission and distribution networks is becoming more challenged with the accelerated increasing of distributed energy resources (DERs) such as distributed photovoltaic (PV) generation and distributed energy storage. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive transmission and distribution co-simulation platform should be developed. Furthermore, with DERs more actively participated in system operation such as providing real time grid services, their cyber vulnerability should be better understood to maintain system reliability. This paper discussed a cyber-physical events emulation based transmission & distribution co-simulation platform to perform different cyber events emulation and analyze the impacts of cyber physical events happened in distribution system on the T&D system operation. The case studies with both a transmission network and a synthetic distribution network data validate that the proposed T&D co-simulation platform can perform comprehensive cyber physical events emulation. Therefore, with extensive simulation using the proposed model, the system operator can accumulate adequate training data for the system situation awareness and grid anomaly detection purpose.

31 CESER - Office of Cybersecurity, Energy Securit↗

Assessing the Reliability Benefits of Energy Storage as a Transmission Asset

Utilizing energy storage solutions to reduce the need for traditional transmission investments has been recognized by system planners and supported by federal policies in recent years. This work demonstrates the need for detailed reliability assessment for quantitative comparison of the reliability benefits of energy storage and traditional transmission investments. First, a mixed-integer linear programming expansion planning model considering candidate transmission lines and storage technologies is solved to find the least-cost investment decisions. Next, operations under the resulting system configuration are simulated in a probabilistic reliability assessment which accounts for weather-dependent forced outages. The outcome of this work, when applied to TPPs, is to further equalize the consideration of energy storage compared to traditional transmission assets by capturing the value of storage for system reliability.

co-optimization↗

Barriers and Opportunities To Realize the System Value of Interregional Transmission

This report identifies barriers within existing rules and operational practices that may limit the system value interregional transmission can provide and identifies a suite of options that could enable greater utilization of and value from interregional transmission. To allow for the variety of power sector structures that exist across the United States, the report divides the evaluation of barriers and opportunities into three sections: common issues that are found in all regions, barriers between non-market or hybrid areas, and barriers between market areas. The report also identifies ambitious, transformative national actions that could unlock transmission value across both market and non-market areas. In the analysis of barriers and potential opportunities for improvement, we recognize these are complex issues that with a diverse set of power system stakeholders and considerations that must be taken into account. The aim of this report is not to make recommendations but to identify options to improve the use of interregional transmission that could be considered alongside other local, state, and regional objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ribavirin targets sugar transporter 6 to suppress acquisition and transmission of rice stripe tenuivirus by its vector Laodelphax striatellus

Abstract BACKGROUND Rice stripe tenuivirus (RSV) is one of the most destructive pathogens of rice and other cereal crops. The virus is transmitted by the small brown planthopper (SBPH, Laodelphax striatellus ) in a circulative‐propagative manner. Thus, blocking transmission by the insect vector would provide an effective strategy to prevent epidemic outbreaks of the disease. RESULTS In this study, we explored the effect of ribavirin on acquisition and transmission of the virus by specifically inhibiting the expression of sugar transporter 6 (LsSt‐6), which was recently reported as a key vector component for RSV transmission. Ribavirin at the highest concentration tested (250 μmol L ‐1 ) significantly reduced RSV acquisition and transmission efficiency by SBPHs through inhibiting LsSt‐6 messenger RNA (mRNA) level. Survival of the model insect Spodoptera frugiperda cell line (Sf9) was 95.0 ± 2.2 and 85.6 ± 2.1% after exposure to 250 μmol L ‐1 ribavirin or 8‐azaguanine, respectively. Further study confirmed that 250 μmol L ‐1 ribavirin also significantly reduced LsSt‐6 mRNA and protein levels in Sf9 cells. However, 8‐azaguanine did not significantly inhibit viral infectivity and LsSt‐6 mRNA levels in SBPH or the Sf9 cell line. CONCLUSION This result provides evidence that ribavirin has the potential to disrupt LsSt‐6 expression but not others like viral RNAs to prevent acquiring RSV, which leads to less viral accumulation in SBPH tissues and thereby lower transmission efficiency. © 2020 Society of Chemical Industry

Hajano, Jamal‐U‐Ddin↗

Dislocation transmission across Σ3{112} incoherent twin boundary: a combined atomistic and phase-field study

Grain boundaries (GBs) in polycrystalline materials act as impediments to dislocation motion and result in strengthening. Understanding slip transmission through GBs, specifically twin boundaries, is essential to understand the plastic deformation behavior of polycrystalline fcc materials. Here the interaction between a glide dislocation and Σ3{112} incoherent twin boundary (ITB) in copper is investigated using a combined atomistic and mesoscale approach. The material parameters and structure of the GB in the mesoscale phase field dislocation dynamics (PFDD) model are informed from Molecular Statics (MS) simulations. The structural unit of the ITB consists of an array of three partial dislocations. The interaction between a glide dislocation impinging on each of the GB partial dislocations is investigated using both PFDD and Molecular Dynamics (MD) with two boundary conditions. Transmission planes predicted by both PFDD and MD (NVT) are in agreement, and show that not all transmission events are direct. Critical transmission stresses predicted by PFDD are in the range of 276 MPa to 1380 MPa, while MD predictions are in the range from 100 MPa to 700 MPa. The PFDD and MD predictions of slip transmission are explained using dislocation theory based on isotropic linear elasticity.

36 MATERIALS SCIENCE↗

PC-RPL: Joint Control of Routing Topology and Transmission Power in Real Low-Power and Lossy Networks

We present PC-RPL , a transmission power-controlled IPv6 routing protocol for low-power and lossy wireless networks that significantly improves the end-to-end packet delivery performance under heavy traffic compared to the standard RPL. We show through actual design, implementation, and experiments that a multihop wireless network can achieve better throughput and routing stability when transmission power and routing topology are “jointly and adaptively” controlled. Our experiments show that the predominant “fixed and uniform” transmission power strategy with “link quality and hop distance”–based routing topology construction (i.e., RPL) loses significant bandwidth due to hidden terminal and load imbalance problems. We design an adaptive and distributed control mechanism for transmission power and routing topology, named PC-RPL , on top of the standard RPL routing protocol for hidden terminal mitigation and load balancing. We implement PC-RPL on real embedded devices and evaluate its performance on a 49-node multihop testbed. PC-RPL reduces total end-to-end packet losses by approximately sevenfold without increasing hop distance compared to RPL with the highest transmission power, resulting in 17% improvement in aggregate bandwidth and 64% improvement for the worst-case node by successfully alleviating both hidden terminal and load imbalance problems.

Computer Science↗

Historic Context, Character-Defining Elements, And Photographic Record For A 26.45-Mile Segment Of The 138-Kilovolt Power Transmission System, Areas 3, 5, 6, And 23, Nevada National Security Site, Nye County, Nevada

The subject of this report is the 138-kilovolt (kV) power transmission line on the Nevada National Security Site (NNSS) (see Figure 1). The NNSS, formerly the Nevada Test Site (NTS), was the main continental nuclear test site for the United States between 1951 and 1992. Known as the battleground of the Cold War, the NNSS hosted a total of 928 nuclear tests during that period. It also served as the location of numerous scientific advancements in the fields of rocketry, big-hole drilling, nuclear waste management, and defense. From its construction in the 1960s through the present day, the 138 kV line has provided electrical power to the numerous buildings, facilities, experiments, and tests on the NNSS. The Department of Energy (DOE), in consultation with the Nevada State Historic Preservation Officer (SHPO), has determined that it may contribute to the character and significance of the Mercury Historic District (MHD) on the NNSS, as well as other historic districts that have not been recorded or evaluated yet. The purpose of this report is to fulfill two of the stipulations in the Memorandum of Agreement DEGM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site (MOA). The MOA was executed as part of the DOE’s obligations under Section 106 of the National Historic Preservation Act (NHPA) to mitigate the adverse effects of two undertakings on historic properties. In particular, this report fulfills MOA Stipulations III.C.1-3, which state that the Department of Energy (DOE) will prepare the following: A historic context for the 138 kV transmission line and identification of the line’s characterdefining elements; High-quality digital images of the 26.45-mile segment of the 138 kV transmission line that is subject to the two undertakings for which the MOA was executed; and Photograph catalogs and map keys showing photograph viewpoints and directions.

54 ENVIRONMENTAL SCIENCES↗

Ground-based Transmission Spectroscopy with VLT FORS2: Evidence for Faculae and Clouds in the Optical Spectrum of the Warm Saturn WASP-110b

We present a ground-based optical transmission spectrum for the warm Saturn-mass exoplanet WASP-110b from two transit observations made with the FOcal Reducer and Spectrograph on the Very Large Telescope. The spectrum covers the wavelength range from 4000–8333 Å, which is binned in 46 transit depths measured to an averaged precision of 220 parts per million (ppm) over an averaged 80 Å bin for a Vmag = 12.8 star. The measured transit depths are unaffected by a dilution from a close A-type field dwarf, which was fully resolved. The overall main characteristic of the transmission spectrum is an increasing radius with wavelength and a lack of the theoretically predicted pressure-broadened sodium and potassium absorption features for a cloud-free atmosphere. We analyze archival high-resolution optical spectroscopy and find evidence for low to moderate activity of the host star, which we take into account in the atmospheric retrieval analysis. Using the AURA retrieval code, we find that the observed transmission spectrum can be best explained by a combination of unocculted stellar faculae and a cloud deck. Transmission spectra of cloud-free and hazy atmospheres are rejected at a high confidence. With a possible cloud deck at its terminator, WASP-110b joins the increasing population of irradiated hot-Jupiter exoplanets with cloudy atmospheres observed in transmission.

47 OTHER INSTRUMENTATION↗

HST PanCET Program: A Complete Near-UV to Infrared Transmission Spectrum for the Hot Jupiter WASP-79b

We present a new optical transmission spectrum of the hot Jupiter WASP-79b. We observed three transits with the STIS instrument mounted on the Hubble Space Telescope (HST), spanning 0.3–1.0 μm. Combining these transits with previous observations, we construct a complete 0.3–5.0 μm transmission spectrum of WASP-79b. Both HST and ground-based observations show decreasing transit depths toward blue wavelengths, contrary to expectations from Rayleigh scattering or hazes. We infer atmospheric and stellar properties from the full near-UV to infrared transmission spectrum of WASP-79b using three independent retrieval codes, all of which yield consistent results. Our retrievals confirm previous detections of H{sub 2}O (at 4.0σ confidence) while providing moderate evidence of H{sup -} bound–free opacity (3.3σ) and strong evidence of stellar contamination from unocculted faculae (4.7σ). The retrieved H{sub 2}O abundance (~1%) suggests a superstellar atmospheric metallicity, though stellar or substellar abundances remain consistent with present observations (O/H = 0.3–34× stellar). All three retrieval codes obtain a precise H{sup -} abundance constraint: log(X{sub H{sup -}}) ≈ -8.0 ± 0.7. The potential presence of H{sup -} suggests that James Webb Space Telescope observations may be sensitive to ionic chemistry in the atmosphere of WASP-79b. The inferred faculae are ~500 K hotter than the stellar photosphere, covering ~15% of the stellar surface. Our analysis underscores the importance of observing UV–optical transmission spectra in order to disentangle the influence of unocculted stellar heterogeneities from planetary transmission spectra.

47 OTHER INSTRUMENTATION↗

Measurements of the UV and VUV transmission of optical materials during high energy electron irradiation

An experimental program was conducted in which the optical transmission of several transparent materials was measured during high energy electron irradiation. These experiments were conducted using the Dynamitron electron accelerator as a continuous source of 1.5 MeV electrons and the LINAC electron accelerator as a pulsed source of 5-7 MeV electrons. The experimental program consisted of three major portions. The first portion, the optical transmission of fused silica, BeO, MgF2, and LiF was measured at vacuum ultraviolet wavelengths in the range 1550-2000 A during ambient temperature, 1.5 MeV electron irradiation at ionizing dose rates to 0.5 Mrad/sec. In the second portion of the program, the optical transmission of fused silica and BeO was measured in the range 2000-3000 A during high dose rate, elevated temperature 1.5 MeV electron irradiation. In particular, accurate measurements of the optical transmission were made at ionizing dose rates as high as 10 Mrad/sec. In the final portion of the program, the optical transmission of fused silica and BeO was measured in the wavelength range 2000-3000 A during pulsed 5 and 7 MeV electron irradiation from the LINAC accelerator. The maximum time averaged ionizing dose rate was limited to 0.75 Mrad/sec due to accelerator limitations.

Palma, G. E.↗