Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Precursory Locking Precedes Slip Events on Laboratory Fault

Earthquakes occur through repeated cycles of locking and slip. What is the relationship between transiently locked patches and the size, location, and timing of the subsequent slip events? Here we use an experimental fault made of transparent rubber to image the slip history of over 18,000 events. The soft elastic system allows for contained ruptures and thus a natural evolution of stress heterogeneity over multiple earthquake cycles. We observe a precursory locking phase preceding slip nucleation for events of all sizes. The integrated locking distance increases linearly with the moment of the eventual event. The most intense (largest slip deficit) locking events are spatially and temporally correlated with the hypocenters of the largest rupture events. These results show that the transient locking is statistically, but not deterministically, predictive of the location, timing, and size of the eventual slip event.

earthquakes↗

Effect of Accurate Modeling of Converter Interfaced Generation (CIG) on a Practical Bulk Power System

With increased penetration of converter interfaced generation (CIG) in power systems, it becomes imperative to adequately model them in both steady-state and dynamic simulations. There are several modeling approaches and simulation platforms for CIG. In addition, it is noted that suitability of modeling approaches and models is also dependent on the system conditions. However, their suitability has yet to be systematically analyzed, and this becomes a challenge in the industry without a systemic method. To tackle these challenges, in this paper, we first develop a methodology for identifying the maximum penetration of aggregated rooftop sources that can be represented as negative loads in both the steady state and dynamic analysis. Then we verify the suitability of positive-sequence performance-based model and detailed electromagnetic transient (EMT) model for utility-scale PV plants under different fault conditions. Based on the results, we perform dynamic simulations on a large practical system with both positive-sequence transient stability(TS) and EMT-TS hybrid simulation. Our study shows that positive-sequence performance based PV plant model is more suitable for study cases with faults relatively far away from the point of connection, and that positive-sequence models and TS simulation approach can produce comparable results with reference to EMT-TS hybrid simulation for normally-cleared single-line-to-ground faults, but the inadequacy of positive-sequence based model and simulation approach becomes obvious for prolonged-tripping of unbalanced faults in proximity of the PV plants.

Huang, Qiuhua↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Implementing Admittance Relaying for Microgrid Protection

An earlier study evaluated issues with microgrid protection. This highlighted the difficulties with microgrid protection, which include: 1. lack of fault current from inverter-interfaced generation, 2. varying fault current between grid-connected and islanded modes, 3. potential for normally-meshed operation and 4. unbalanced operation due to single-phase loads. It is worth noting that not all microgrid designs will include all these challenges. For example, microgrids could choose to omit meshed operation. Previous work identified differential protection based on the discrete S-transform for line protection and admittance protection for load protection as possible solutions . However, some severe limitations were identified. This included the potential for blinding of the discrete S-transform protection when fault contribution on either end of the line is similar, and loss of protection selectivity for admittance protection in the case of upstream line-ground faults. This report investigates admittance protection as a solution for line and load protection in greater detail by comparing analytical and simulated results. Section 2 describes the protection schemes analyzed and the behavior of inverter-interfaced microgrids under faults in more detail. Section 3 derives sequence networks for the fault cases considered. Section 4 presents a transient model constructed to validate the impedances calculated from the sequence networks. Section 5 compares the results from the sequence networks and transient model. Last, Section 6 presents the conclusions of this study in terms of the suitability of admittance relaying for protection of inverter-interfaced microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Fringe Reading Facility at the Max-Planck-Institut fuer Stroemungsforschung

A Mach-Zehnder interferometer is used for optical flow measurements in a transonic wind tunnel. Holographic interferograms are reconstructed by illumination with a He-Ne-laser and viewed by a video camera through wide angle optics. This setup was used for investigating industrial double exposure holograms of truck tires in order to develop methods of automatic recognition of certain manufacturing faults. Automatic input is achieved by a transient recorder digitizing the output of a TV camera and transferring the digitized data to a PDP11-34. Interest centered around sequences of interferograms showing the interaction of vortices with a profile and subsequent emission of sound generated by this process. The objective is the extraction of quantitative data which relates to the emission of noise.

Becker, F.↗

Automatic recognition of intermittent failures - An experimental study of field data

A methodology is proposed for recognizing the symptoms of persistent problems in large systems. The system error rate is used to identify the error states among which relationships may exist. Statistical techniques are used to validate and quantify the strength of the relationship among these error states. As input, the approach takes the raw error logs containing a single entry for each error that is detected as an isolated event. As output, it produces a list of symptoms that characterize persistent errors. Thus, given a failure, it is determined whether the failure is an intermittent manifestation of a common fault or whether it is an isolated (transient) incident. The technique is shown to work on two CYBER systems and an IBM 3081 multiprocessor system. Comparisons to real failure/repair information obtained from field engineers show that, in about 85 percent of the cases, the error symptoms recognized by this approach correspond to real problems. The remaining 15 percent of the cases, although not directly supported by field data, are confirmed as being valid problems.

Iyer, Ravishankar K.↗

Summary of Test Results From a 1 kW(sub e)-Class Free-Piston Stirling Power Convertor Integrated With a Pumped NaK Loop

As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors was modified to operate with a NaK liquid metal pumped loop for thermal energy input. This was the first-ever attempt at powering a free-piston Stirling engine with a pumped liquid metal heat source and is a major FSP project milestone towards demonstrating technical feasibility. The tests included performance mapping the convertors over various hot and cold-end temperatures, piston amplitudes and NaK flow rates; and transient test conditions to simulate various start-up and fault scenarios. Performance maps of the convertors generated using the pumped NaK loop for thermal input show increases in power output over those measured during baseline testing using electric heating. Transient testing showed that the Stirling convertors can be successfully started in a variety of different scenarios and that the convertors can recover from a variety of fault scenarios.

Briggs, Maxwell H.↗

Summary of Test Results From a 1 kWe-Class Free-Piston Stirling Power Convertor Integrated With a Pumped NaK Loop

As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors was modified to operate with a NaK liquid metal pumped loop for thermal energy input. This was the first-ever attempt at powering a free-piston Stirling engine with a pumped liquid metal heat source and is a major FSP project milestone towards demonstrating technical feasibility. The tests included performance mapping the convertors over various hot and cold-end temperatures, piston amplitudes and NaK flow rates; and transient test conditions to simulate various start-up and fault scenarios. Performance maps of the convertors generated using the pumped NaK loop for thermal input show increases in power output over those measured during baseline testing using electric heating. Transient testing showed that the Stirling convertors can be successfully started in a variety of different scenarios and that the convertors can recover from a variety of fault scenarios.

Briggs, Maxwell H.↗

Imaging of Earthquake Faults Using Small UAVs as a Pathfinder for Air and Space Observations

Large earthquakes cause billions of dollars in damage and extensive loss of life and property. Geodetic and topographic imaging provide measurements of transient and long-term crustal deformation needed to monitor fault zones and understand earthquakes. Earthquake-induced strain and rupture characteristics are expressed in topographic features imprinted on the landscapes of fault zones. Small UAVs provide an efficient and flexible means to collect multi-angle imagery to reconstruct fine scale fault zone topography and provide surrogate data to determine requirements for and to simulate future platforms for air- and space-based multi-angle imaging.

Donnellan, Andrea↗

Xilinx Kintex-UltraScale Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

This is an independent investigation that evaluates the single event destructive and transient susceptibility of the Xilinx Kintex-UltraScale device. Design/Device susceptibility is determined by monitoring the device under test (DUT) for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) is monitored throughout heavy-ion testing by examining device current. This device does not have embedded mitigation. Hence, user implemented mitigation is investigated using Synopsys mitigation tools.

Single Event Transient (SET)↗

Modeling of periodic great earthquakes on the San Andreas fault: Effects of nonlinear crustal rheology

We analyze the cycle of great earthquakes along the San Andreas fault with a finite element numerical model of deformation in a crust with a nonlinear viscoelastic rheology. The viscous component of deformation has an effective viscosity that depends exponentially on the inverse absolute temperature and nonlinearity on the shear stress; the elastic deformation is linear. Crustal thickness and temperature are constrained by seismic and heat flow data for California. The models are for anti plane strain in a 25-km-thick crustal layer having a very long, vertical strike-slip fault; the crustal block extends 250 km to either side of the fault. During the earthquake cycle that lasts 160 years, a constant plate velocity v(sub p)/2 = 17.5 mm yr is applied to the base of the crust and to the vertical end of the crustal block 250 km away from the fault. The upper half of the fault is locked during the interseismic period, while its lower half slips at the constant plate velocity. The locked part of the fault is moved abruptly 2.8 m every 160 years to simulate great earthquakes. The results are sensitive to crustal rheology. Models with quartzite-like rheology display profound transient stages in the velocity, displacement, and stress fields. The predicted transient zone extends about 3-4 times the crustal thickness on each side of the fault, significantly wider than the zone of deformation in elastic models. Models with diabase-like rheology behave similarly to elastic models and exhibit no transient stages. The model predictions are compared with geodetic observations of fault-parallel velocities in northern and central California and local rates of shear strain along the San Andreas fault. The observations are best fit by models which are 10-100 times less viscous than a quartzite-like rheology. Since the lower crust in California is composed of intermediate to mafic rocks, the present result suggests that the in situ viscosity of the crustal rock is orders of magnitude less the rock viscosity determined in the laboratory.

Reches, Ze'ev↗

Testing For EM Upsets In Aircraft Control Computers

Effects of transient electrical signals evaluated in laboratory tests. Method of evaluating nominally fault-tolerant, aircraft-type digital-computer-based control system devised. Provides for evaluation of susceptibility of system to upset and evaluation of integrity of control when system subjected to transient electrical signals like those induced by electromagnetic (EM) source, in this case lightning. Beyond aerospace applications, fault-tolerant control systems becoming more wide-spread in industry; such as in automobiles. Method supports practical, systematic tests for evaluation of designs of fault-tolerant control systems.

Belcastro, Celeste M.↗

Microsemi RTG4 Rev C Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

The goal of this study was to perform an independent investigation of single event destructive and transient susceptibility of the Microsemi RTG4 device. The devices under test were the Microsemi RTG4 field programmable gate array (FPGA) Rev C. The devices under test will be referenced as the DUT or RTG4 Rev C throughout this document. The DUT was configured to have various test structures that are geared to measure specific potential susceptibilities of the device. DesignDevice susceptibility was determined by monitoring the DUT for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) was checked throughout heavy-ion testing by monitoring device current.

Field Programmable Gate Array (FPGA)↗

The viscoelastic stiffness model of seismicity

A viscoelastic stiffness model of seismicity is developed by introducing a viscoelastic element into the stiffness model for fault dynamics. The introduction of this element permits modeling of transient anelastic deformations in response to stress loading and relaxation and provides a mechanism for partial stress recovery following an earthquake. As a consequence, several phenomena not present in elastic stiffness theory emerge. These include postseismic creep, foreshocks, and aftershocks. Numerical simulations of fault motion also reveal episodes of stable sliding, tertiary creep preceeding earthquakes, and long-term aseismic creep.

Cohen, S. C.↗

Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids

Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions if transmission faults occur during restoration. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. Furthermore, this paper is significant to address recommendations by the North American Electric Reliability Corporation.

17 WIND ENERGY↗

Deep learning model for fast, science-based forecasting of fluid migration along faults in geologic carbon storage scenarios

Effective long-term geologic storage depends on robust site selection and credible, science-based forecasting of subsurface behavior to ensure storage integrity. For this work, we develop a deep learning–based reduced-order model (ROM) to quantify potential carbon dioxide (CO₂) and brine migration through geological faults. The ROM combines a Transformer model for binary classification and a Stacked Ensemble for regression, trained on a comprehensive dataset generated from 1400 physics-based reservoir simulations. Key geologic and operational parameters—including fault geometry, reservoir structure, and injection conditions—were systematically varied to capture a wide range of fluid migration scenarios. The ROM accurately predicts the onset of migration, cumulative migration volumes of both CO₂ and brine, and associated migration rates, as compared to an independent set of validation simulations, while significantly reducing computational cost compared to traditional simulation methods. Model performance was evaluated across diverse fault configurations, revealing that shallow reservoir geometry and fault angle are among the most influential factors governing migration behavior. Sensitivity analysis using SHapley Additive exPlanations (SHAP) provided interpretability, revealing distinct patterns in how geological and operational features drive transient versus cumulative migration outcomes. The ROM’s ability to rapidly simulate fault migration scenarios enables efficient sensitivity analyses, scenario evaluations, and decision support for site selection and monitoring design. This approach enhances the safety, scalability, and long-term operational performance of geologic carbon storage (GCS) systems by providing a robust, interpretable tool for predicting subsurface fluid migration and assessing fault-related migration potential.

42 ENGINEERING↗

Analog-digital simulation of transient-induced logic errors and upset susceptibility of an advanced control system

A simulation study is described which predicts the susceptibility of an advanced control system to electrical transients resulting in logic errors, latched errors, error propagation, and digital upset. The system is based on a custom-designed microprocessor and it incorporates fault-tolerant techniques. The system under test and the method to perform the transient injection experiment are described. Results for 2100 transient injections are analyzed and classified according to charge level, type of error, and location of injection.

Carreno, Victor A.↗