Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Tomographic optical emission spectroscopy of an atmospheric pressure plasma jet and surface ionization waves on planar and structured surfaces

Here in this paper, an approach for 3D plasma structure diagnostics using tomographic optical emission spectroscopy (Tomo-OES) of a nanosecond pulsed atmospheric pressure plasma jet (APPJ) is presented. In contrast to the well-known Abel inversion, Tomo-OES does not require cylindrical symmetry to recover 3D distributions of plasma light emission. Instead, many 2D angular projections are measured with intensified cameras and the multiplicative algebraic reconstruction technique is used to recover the 3D distribution of light emission. This approach solves the line-of-sight integration problem inherent to optical diagnostics, allowing recovery of localized OES information within the plasma that can be used to better infer plasma parameters within complex plasma structures. Here, Tomo-OES was applied to investigate an APPJ operated with helium in ambient air and impinging on planar and structured dielectric surfaces. Surface charging caused the guided streamer from the APPJ to transition to a surface ionization wave (SIW) that propagated along the surface. The SIW experienced variable geometrical and electrical material properties as it propagated, leading to 3D configurations that were non-symmetric and spatially complex. Light emission from He, N$_2^+$, and N2 were imaged at ten angular projections and the respective time-resolved 3D emission distributions in the plasma were then reconstructed. The spatial resolution of each tomographic reconstruction was 7.4 µm and the temporal resolution was 5 ns, sufficient to observe the guided streamer and the effects of the structured surface on the SIW. Emission from He showed the core of the jet and emission from N$_2^+$ and N2 indicated effects of entrainment of ambient air. Penning ionization of N2 created a ring or outer layer of N$_2^+$ that spatially converged to form the 'plasma bullet' or spatially diverged across a surface as part of a SIW. The SIW entered trenches of size 150 µm, leading to decreases in plasma light emission in regions above the trenches. The plasma light emission was higher in some regions with trenches, possibly due to effects of field enhancement.

plasma interactions with complex surfaces↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted]↗

Longitudinal Phase Space Tomography for the Booster Synchrotron (Abstract Only)

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted, US]↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography had been employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor signal, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted; Fermilab]↗

Mineral and organic matrix interaction in normally calcifying tendon visualized in three dimensions by high-voltage electron microscopic tomography and graphic image reconstruction

To define the ultrastructural accommodation of mineral crystals by collagen fibrils and other organic matrix components during vertebrate calcification, electron microscopic 3-D reconstructions were generated from the normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo. Embedded specimens containing initial collagen mineralizing sites were cut into 0.5-micron-thick sections and viewed and photographed at 1.0 MV in the Albany AEI-EM7 high-voltage electron microscope. Tomographic 3-D reconstructions were computed from a 2 degree tilt series of micrographs taken over a minimum angular range of +/- 60 degrees. Reconstructions of longitudinal tendon profiles confirm the presence of irregularly shaped mineral platelets, whose crystallographic c-axes are oriented generally parallel to one another and directed along the collagen long axes. The reconstructions also corroborate observations of a variable crystal length (up to 170 nm measured along crystallographic c-axes), the presence of crystals initially in either the hole or overlap zones of collagen, and crystal growth in the c-axis direction beyond these zones into adjacent overlap and other hole regions. Tomography shows for the first time that crystal width varies (30-45 nm) but crystal thickness is uniform (approximately 4-6 nm at the resolution limit of tomography); more crystals are located in the collagen hole zones than in the overlap regions at the earliest stages of tendon mineralization; the crystallographic c-axes of the platelets lie within +/- 15-20 degrees of one another rather than being perfectly parallel; adjacent platelets are spatially separated by a minimum of 4.2 +/- 1.0 nm; crystals apparently fuse in coplanar alignment to form larger platelets; development of crystals in width occurs to dimensions beyond single collagen hole zones; and a thin envelope of organic origin may be present along or just beneath the surfaces of individual mineral platelets. Implicit in the results is that the formation of crystals occurs at different sites and times by independent nucleation events in local regions of collagen. These data provide the first direct visual evidence from 3-D imaging describing the size, shape, orientation, and growth of mineral crystals in association with collagen of a normally mineralizing vertebrate tissue. They support concepts that c-axial crystal growth is unhindered by collage hole zone dimensions, that crystals are organized in the tendon in a series of generally parallel platelets, and that crystal growth in width across collagen fibrils may follow channels or grooves formed by adjacent hole zones in register.

Non-NASA Center↗

Tomographic and analog 3-D simulations using NORA

The results of two computer simulations demonstrate the feasibility of using the nonoverlapping redundant array (NORA) to form three-dimensional images of objects with X-rays. Pinholes admit the X-rays to nonoverlapping points on a detector. The object is reconstructed in the analog mode by optical correlation and in the digital mode by tomographic computations. Trials were run with a stick-figure pyramid and extended objects with out-of-focus backgrounds. Substitution of spherical optical lenses for the pinholes increased the light transmission sufficiently that objects could be easily viewed in a dark room. Out-of-focus aberrations in tomographic reconstruction could be eliminated using Chang's (1976) algorithm.

Yin, L. I.↗

Exploring the Great Pyramid

For centuries, the pyramids at Giza have been the object of frequent speculation and study. L. Alvarez et al. in 1970 and the ScanPyramids collaboration in 2017 have very successfully implemented HEP detector technology to image the pyramid of Khafre and the Great Pyramid of Khufu, respectively. Numerous questions about Khufu’s structure remain, however. The EGP project aims to undertake a new study of this enigmatic monument’s interior by applying high-resolution tomographic imaging and reconstruction, which will permit a detailed understanding of internal variations in density and may offer insight regarding exactly how Egypt’s largest pyramid was built.

43 PARTICLE ACCELERATORS↗

Computer tomography of flows external to test models

Computer tomographic techniques for reconstruction of three-dimensional aerodynamic density fields, from interferograms recorded from several different viewing directions were studied. Emphasis is on the case in which an opaque object such as a test model in a wind tunnel obscures significant regions of the interferograms (projection data). A method called the Iterative Convolution Method (ICM), existing methods in which the field is represented by a series expansions, and analysis of real experimental data in the form of aerodynamic interferograms are discussed.

Prikryl, I.↗

Optical tomography for flow visualization of the density field around a revolving helicopter rotor blade

In this paper, a tomographic procedure for reconstructing the density field around a helicopter rotor blade tip from remote optical line-of-sight measurements is discussed. Numerical model studies have been carried out to investigate the influence of the number of available views, limited width viewing, and ray bending on the reconstruction. Performance is measured in terms of the mean-square error. It is found that very good reconstructions can be obtained using only a small number of views even when the width of view is smaller than the spatial extent of the object. An iterative procedure is used to correct for ray bending due to refraction associated with the sharp density gradients (shocks).

Snyder, R.↗

Quantitative determination of the mineral distribution in different collagen zones of calcifying tendon using high voltage electron microscopic tomography

High voltage electron microscopic tomography was used to make the first quantitative determination of the distribution of mineral between different regions of collagen fibrils undergoing early calcification in normal leg tendons of the domestic turkey, Meleagris gallopavo. The tomographic 3-D reconstruction was computed from a tilt series of 61 different views spanning an angular range of +/- 60 degrees in 2 degrees intervals. Successive applications of an interactive computer operation were used to mask the collagen banding pattern of either hole or overlap zones into separate versions of the reconstruction. In such 3-D volumes, regions specified by the mask retained their original image density while the remaining volume was set to background levels. This approach was also applied to the mineral crystals present in the same volumes to yield versions of the 3-D reconstructions that were masked for both the crystal mass and the respective collagen zones. Density profiles from these volumes contained a distinct peak corresponding only to the crystal mass. A comparison of the integrated density of this peak from each profile established that 64% of the crystals observed were located in the collagen hole zones and 36% were found in the overlap zones. If no changes in crystal stability occur once crystals are formed, this result suggests the possibilities that nucleation of mineral is preferentially and initially associated with the hole zones, nucleation occurs more frequently in the hole zones, the rate of crystal growth is more rapid in the hole zones, or a combination of these alternatives. All lead to the conclusion that the overall accumulation of mineral mass is predominant in the collagen hole zones compared to overlap zones during early collagen fibril calcification.

NASA Program Space Biology↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Automatic 3D image registration for nano-resolution chemical mapping using synchrotron spectro-tomography

Nano-resolution synchrotron X-ray spectro-tomography has been demonstrated as a powerful tool for probing the three-dimensional (3D) structural and chemical heterogeneity of a sample. By reconstructing a number of tomographic data sets recorded at different X-ray energy levels, the energy-dependent intensity variation in every given voxel fingerprints the corresponding local chemistry. The resolution and accuracy of this method, however, could be jeopardized by non-ideal experimental conditions, e.g. instability in the hardware system and/or in the sample itself. Herein is presented one such case, in which unanticipated sample deformation severely degrades the data quality. Here, to address this issue, an automatic 3D image registration method is implemented to evaluate and correct this effect. The method allows the redox heterogeneity in partially delithiated Li x Ta 0.3 Mn 0.4 O 2 battery cathode particles to be revealed with significantly improved fidelity.

3D image registration↗

Hybrid-dual-fourier tomographic algorithm for a fast three-dimensionial optical image reconstruction in turbid media

A reconstruction technique for reducing computation burden in the 3D image processes, wherein the reconstruction procedure comprises an inverse and a forward model. The inverse model uses a hybrid dual Fourier algorithm that combines a 2D Fourier inversion with a 1D matrix inversion to thereby provide high-speed inverse computations. The inverse algorithm uses a hybrid transfer to provide fast Fourier inversion for data of multiple sources and multiple detectors. The forward model is based on an analytical cumulant solution of a radiative transfer equation. The accurate analytical form of the solution to the radiative transfer equation provides an efficient formalism for fast computation of the forward model.

Alfano, Robert R.↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗