Direct imaging of neural currents using ultra-low field magnetic resonance techniques

Using resonant interactions to directly and tomographically image neural activity in the human brain using magnetic resonance imaging (MRI) techniques at ultra-low field (ULF), the present inventors have established an approach that is sensitive to magnetic field distributions local to the spin population in cortex at the Larmor frequency of the measurement field. Because the Larmor frequency can be readily manipulated (through varying B.sub.m), one can also envision using ULF-DNI to image the frequency distribution of the local fields in cortex. Such information, taken together with simultaneous acquisition of MEG and ULF-NMR signals, enables non-invasive exploration of the correlation between local fields induced by neural activity in cortex and more `distant` measures of brain activity such as MEG and EEG.

60 APPLIED LIFE SCIENCES↗

Magnetic field induced differential neutron phase contrast imaging

Besides the attenuation of a neutron beam penetrating an object, induced phase changes have been utilized to provide contrast in neutron and x-ray imaging. In analogy to differential phase contrast imaging of bulk samples, the refraction of neutrons by magnetic fields yields image contrast. Here, it will be reported how double crystal setups can provide quantitative tomographic images of magnetic fields. The use of magnetic air prisms adequate to split the neutron spin states enables a distinction of field induced phase shifts and these introduced by interaction with matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Segmentation, statistical analysis, and modelling of the wall system in ceramic foams

Closed walls in otherwise open foam structures may have a great impact on macroscopic properties of the materials. In this paper, we present two algorithms for the segmentation of such closed walls from micro-computed tomography images of the foam structure. The techniques are compared on simulated data and applied to tomographic images of ceramic filters. This allows for a detailed statistical analysis of the normal directions and sizes of the walls. Finally, we explain how the information derived from the segmented wall system can be included in a stochastic microstructure model for the foam.

36 MATERIALS SCIENCE↗

QUANTITATIVE HOMOGENEITY AND IN-CONTACT PARTICLES OF HIGH TEMPERATURE REACTORS (HTR) COMPACTS DETERMINATION VIA X-RAY TOMOGRAPHY

In AREVA Nuclear Power's High Temperature Reactor (HTR) design called ANTARES, fuel consists of compacts composed of few thousands millimetric quasi-spherical particles dispersed in a graphite matrix. Compact homogeneity, defined as the homogeneous particles spatial distribution in the matrix, as well as the possibility of obtaining particles in contact, need to be assessed since they condition the thermo-mechanical behavior of the nuclear fuel under irradiation. In this paper, image and data processing algorithms are developed to do so, based on X-Ray tomographic images.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

The second-order differential phase contrast and its retrieval for imaging with x-ray Talbot interferometry

Purpose: The x-ray differential phase contrast imaging implemented with the Talbot interferometry has recently been reported to be capable of providing tomographic images corresponding to attenuation-contrast, phase-contrast, and dark-field contrast, simultaneously, from a single set of projection data. The authors believe that, along with small-angle x-ray scattering, the second-order phase derivative {Phi}{sup Double-Prime }{sub s}(x) plays a role in the generation of dark-field contrast. In this paper, the authors derive the analytic formulae to characterize the contribution made by the second-order phase derivative to the dark-field contrast (namely, second-order differential phase contrast) and validate them via computer simulation study. By proposing a practical retrieval method, the authors investigate the potential of second-order differential phase contrast imaging for extensive applications. Methods: The theoretical derivation starts at assuming that the refractive index decrement of an object can be decomposed into {delta}={delta}{sub s}+{delta}{sub f}, where {delta}{sub f} corresponds to the object's fine structures and manifests itself in the dark-field contrast via small-angle scattering. Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the contribution made by {delta}{sub s}, which corresponds to the object's smooth structures, to the dark-field contrast are derived. Through computer simulation with specially designed numerical phantoms, an x-ray differential phase contrast imaging system implemented with the Talbot interferometry is utilized to evaluate and validate the derived formulae. The same imaging system is also utilized to evaluate and verify the capability of the proposed method to retrieve the second-order differential phase contrast for imaging, as well as its robustness over the dimension of detector cell and the number of steps in grating shifting. Results: Both analytic formulae and computer simulations show that, in addition to small-angle scattering, the contrast generated by the second-order derivative is magnified substantially by the ratio of detector cell dimension over grating period, which plays a significant role in dark-field imaging implemented with the Talbot interferometry. Conclusions: The analytic formulae derived in this work to characterize the second-order differential phase contrast in the dark-field imaging implemented with the Talbot interferometry are of significance, which may initiate more activities in the research and development of x-ray differential phase contrast imaging for extensive preclinical and eventually clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.200900420) and the Radiation Technology Research and Development program (Grant No.2013043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

Segmentation of nanotomographic cortical bone images for quantitative characterization of the osteoctyte lacuno-canalicular network

A newly developed data processing method able to characterize the osteocytes lacuno-canalicular network (LCN) is presented. Osteocytes are the most abundant cells in the bone, living in spaces called lacunae embedded inside the bone matrix and connected to each other with an extensive network of canals that allows for the exchange of nutrients and for mechanotransduction functions. The geometrical three-dimensional (3D) architecture is increasingly thought to be related to the macroscopic strength or failure of the bone and it is becoming the focus for investigating widely spread diseases such as osteoporosis. To obtain 3D LCN images non-destructively has been out of reach until recently, since tens-of-nanometers scale resolution is required. Ptychographic tomography was validated for bone imaging in [1], showing clearly the LCN. The method presented here was applied to 3D ptychographic tomographic images in order to extract morphological and geometrical parameters of the lacuno-canalicular structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Optimizing Magnetite Nanoparticles for Mass Sensitivity in Magnetic Particle Imaging

Purpose: Magnetic particle imaging (MPI), using magnetite nanoparticles (MNPs) as tracer material, shows great promise as a platform for fast tomographic imaging. To date, the magnetic properties of MNPs used in imaging have not been optimized. As nanoparticle magnetism shows strong size dependence, we explore how varying MNP size impacts imaging performance in order to determine optimal MNP characteristics for MPI at any driving field frequency f 0 . Methods: Monodisperse MNPs of varying size were synthesized and their magnetic properties characterized. Their MPI response was measured experimentally, at an arbitrarily chosen f 0 = 250 kHz, using a custom-built MPI transceiver designed to detect the third harmonic of MNP magnetization. Results were interpreted using a model of dynamic MNP magnetization that is based on the Langevin theory of superparamagnetism and accounts for sample size distribution, and size-dependent magnetic relaxation. Results: Our experimental results show clear variation in the MPI signal intensity as a function of MNP size that is in good agreement with modeled results. A maxima in the plot of MPI signal vs. MNP size indicates there is a particular size that is optimal for the chosen frequency of 250 kHz. Conclusions: For MPI at any chosen frequency, there will exist a characteristic particle size that generates maximum signal amplitude. We illustrate this at 250 kHz with particles of 15 nm core diameter.

36 MATERIALS SCIENCE↗

Expediting model-based optoacoustic reconstructions with tomographic symmetries

Purpose: Image quantification in optoacoustic tomography implies the use of accurate forward models of excitation, propagation, and detection of optoacoustic signals while inversions with high spatial resolution usually involve very large matrices, leading to unreasonably long computation times. The development of fast and memory efficient model-based approaches represents then an important challenge to advance on the quantitative and dynamic imaging capabilities of tomographic optoacoustic imaging. Methods: Herein, a method for simplification and acceleration of model-based inversions, relying on inherent symmetries present in common tomographic acquisition geometries, has been introduced. The method is showcased for the case of cylindrical symmetries by using polar image discretization of the time-domain optoacoustic forward model combined with efficient storage and inversion strategies. Results: The suggested methodology is shown to render fast and accurate model-based inversions in both numerical simulations andpost mortem small animal experiments. In case of a full-view detection scheme, the memory requirements are reduced by one order of magnitude while high-resolution reconstructions are achieved at video rate. Conclusions: By considering the rotational symmetry present in many tomographic optoacoustic imaging systems, the proposed methodology allows exploiting the advantages of model-based algorithms with feasible computational requirements and fast reconstruction times, so that its convenience and general applicability in optoacoustic imaging systems with tomographic symmetries is anticipated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4D insights into lithium-ion battery sidewall rupture during thermal runaway

Thermal runaway (TR), characterized by rapid exothermic reactions, presents a serious safety risk in lithium-ion batteries (LiBs). External triggers such as high temperatures, mechanical abuse, or internal short circuits (ISCs) can initiate TR, often resulting in sidewall rupture, which may escalate to catastrophic battery pack failure. In this study, we developed and applied high-speed synchrotron imaging techniques to investigate sidewall rupture mechanisms in LiBs subjected to different triggering scenarios. Using in situ 4D tomographic imaging, we visualized the dynamic evolution of sidewall rupture with high spatial and temporal resolution. The results revealed distinct failure behaviors linked to each trigger, underscoring the complex and condition-specific nature of sidewall breach and battery failure. These insights highlight the critical importance of implementing tailored safety strategies across diverse applications. Our findings demonstrate the powerful potential of synchrotron high-speed tomography as a diagnostic tool for advanced safety testing and cell qualification.

25 ENERGY STORAGE↗

TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion: Quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The PICASSO digital detector for Diffraction Enhanced Imaging at ELETTRA

A clinical mammography program is in progress at the medical beamline SYRMEP of the Italian synchrotron radiation laboratory ELETTRA in Trieste. A conventional screen-film system is utilized as detector for the examinations on patients. For the next experimental step a digital detector has been designed taking into account the essential requirements for mammography such as high spatial and contrast resolution, high efficiency for low dose examinations and high speed for short acquisition time. A double-layer prototype has already been tested in the frame of the PICASSO project. In addition, an analyzer crystal set-up for Diffraction Enhanced Imaging (DEI) has been available for many years at the SYRMEP beamline. Applying the DEI technique several successful experiments have been carried out in biomedical imaging and in particular in-vitro breast imaging utilizing commercially available detectors. Recently a system upgrade yielded a double-crystal analyzer set-up with improved stability and higher angular resolution. In this study the PICASSO detector has been utilized in combination with the new analyzer set-up for imaging in-vitro breast tissue samples. In order to test the potential of the combined system planar and tomographic images have been acquired and the first results are here presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-FG-CAMPUS-JeP1-05: Water Equivalent Path Length Calculations Using Scatter-Corrected Head and Neck CBCT Images to Evaluate Patients for Adaptive Proton Therapy

Purpose: To establish a method to evaluate the dosimetric impact of anatomic changes in head and neck patients during proton therapy by using scatter-corrected cone-beam CT (CBCT) images. Methods: The water equivalent path length (WEPL) was calculated to the distal edge of PTV contours by using tomographic images available for six head and neck patients received photon therapy. The proton range variation was measured by calculating the difference between the distal WEPLs calculated with the planning CT and weekly treatment CBCT images. By performing an automatic rigid registration, six degrees-of-freedom (DOF) correction was made to the CBCT images to account for the patient setup uncertainty. For accurate WEPL calculations, an existing CBCT scatter correction algorithm, whose performance was already proven for phantom images, was calibrated for head and neck patient images. Specifically, two different image similarity measures, mutual information (MI) and mean square error (MSE), were tested for the deformable image registration (DIR) in the CBCT scatter correction algorithm. Results: The impact of weight loss was reflected in the distal WEPL differences with the aid of the automatic rigid registration reducing the influence of patient setup uncertainty on the WEPL calculation results. The WEPL difference averaged over distal area was 2.9 ± 2.9 (mm) across all fractions of six patients and its maximum, mostly found at the last available fraction, was 6.2 ± 3.4 (mm). The MSE-based DIR successfully registered each treatment CBCT image to the planning CT image. On the other hand, the MI-based DIR deformed the skin voxels in the planning CT image to the immobilization mask in the treatment CBCT image, most of which was cropped out of the planning CT image. Conclusion: The dosimetric impact of anatomic changes was evaluated by calculating the distal WEPL difference with the existing scatter-correction algorithm appropriately calibrated. Jihun Kim, Yang-Kyun Park, Gregory Sharp, and Brian Winey have received grant support from the NCI Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Calculating Trajectories Associated With Solute Transport in a Heterogeneous Medium

Here, we present a trajectory-based technique for calculating solute transport in a porous medium that has several advantages over existing methods. Unlike streamlines, the extended trajectories are influenced by each of the important parameters governing transport, including molecular diffusion and transverse dispersion. The approach is complete and does not require any additional techniques, such as operator splitting or particle tracking, in order to account for the full dispersion tensor. The semianalytic expressions make it clear how the flow field, the concentration distribution, and the dispersion tensor contribute to the velocity field of an injected solute. The equations are valid for an arbitrary porous medium, including those with rapid spatial variations in properties, overcoming limitations faced by previous approaches based upon asymptotic techniques. A test on a layered model with sharp boundaries indicates that the extended trajectories are compatible with the results of a numerical simulator and differ from streamlines. We also describe a new form of the dispersion tensor that incorporates a known asymmetry. The trajectories indicate that the modifications of the dispersion tensor lead to more focused transport within regions of high conductivity. The trajectories are used to define a semianalytic relationship between solute travel times and variations in solute velocities along a path that may be used for tomographic imaging. In an application to the injection of a radioactive tracer into a Berea sandstone core, monitored using micropositron emission tomographic (micro-PET) observations, the sensitivities are used to map the spatial variations of permeability within the core.

42 ENGINEERING↗