Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Results of a study to build a gamma-ray telescope in an external tank

In response to the ever-present need for a very large gamma-ray detector for energies greater than 100 MeV, a concept to build a telescope of 250,000 sq cm sensitive area using a Space Shuttle External Tank (ET) is presented. In the Space Station era, for the first time, large detectors can be constructed on-orbit which would otherwise be limited in size by the launch vehicle. The ET will serve both as the spacecraft and the Cherenkov pressure vessel. The significant feature is that the sensitive area will be forty times that of the high energy detector on GRO and will be able to locate even the faintest sources from the GRO survey to a few arc minutes. The detection technique is based upon that originally proposed by Greisen.

Koch, D.↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

NuSTAR Observations of X-Ray Bursts from the Magnetar 1E 1048.1-5937

We report the detection of eight bright X-ray bursts from the 6.5 s magnetar 1E 1048.1−5937, during a 2013 July observation campaign with the Nuclear Spectroscopic Telescope Array. We study the morphological and spectral properties of these bursts and their evolution with time. The bursts resulted in count rate increases by orders of magnitude, sometimes limited by the detector dead time, and showed blackbody spectra with kT is approx. 6-8 keV in the T90 duration of 1-4 s, similar to earlier bursts detected from the source. We find that the spectra during the tail of the bursts can be modeled with an absorbed blackbody with temperature decreasing with flux. The burst flux decays followed a power law of index 0.8-0.9. In the burst tail spectra, we detect a is approx. 13 keV emission feature, similar to those reported in previous bursts from this source as well as from other magnetars observed with the Rossi X-ray Timing Explorer.We explore possible origins of the spectral feature such as proton cyclotron emission, which implies a magnetic field strength of B is approx. 2×10(exp15) G in the emission region. However, the consistency of the energy of the feature in different objects requires further explanation.

MAGNETAR 1E 1048.1-5937↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic Background Rejection of the ICARUS experiment at Fermilab

The Short Baseline Neutrino program at Fermilab aims to explore significant regions of parameter space, applicable to sterile neutrinos at the eV mass scale, as suggested by existing experimental anomalies. To this purpose it exploits Liquid Argon Time Projection Chamber detectors located along the Booster Neutrino Beamline to measure both νe appearance and νµ disappearance: the Short Baseline Neutrino Detector and the ICARUS-T600 detector at 110 and 600 m from the neutrino source, respectively. The ICARUS T-600 Far Detector, located at shallow depth, is surrounded by a Cosmic Ray Tagger system to mitigate the cosmic ray background. On average ~ 11 muon tracks are expected to cross the detector during the ~ 1 ms drift time. The cosmic ray tagger is composed of plastic scintillator bars, ensuring near 4π coverage of the detector aiming at tagging cosmic muons and thus reject 𝛾s produced by muon interactions in the surrounding materials that can generate an electromagnetic showers mimicking a νe signal. The system allows one to disentangle cosmic rays from particles originated in a neutrino interaction inside the detector by measuring their position and crossing time. A synchronization of the cosmic ray tagger with the ICARUS photon detection system with a nanosecond accuracy allows one to reject cosmic particles recorded during the beam spill and thus select an enriched sample of neutrino triggered events ahead of the event reconstruction. An overview of the cosmic ray tagger system as well as its role in the neutrino events identification and cosmic background rejection will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle-based fast jet simulation at the LHC with variational autoencoders

Abstract We study how to use deep variational autoencoders (VAEs) for a fast simulation of jets of particles at the Large Hadron Collider. We represent jets as a list of constituents, characterized by their momenta. Starting from a simulation of the jet before detector effects, we train a deep VAE to return the corresponding list of constituents after detection. Doing so, we bypass both the time-consuming detector simulation and the collision reconstruction steps of a traditional processing chain, speeding up significantly the events generation workflow. Through model optimization and hyperparameter tuning, we achieve state-of-the-art precision on the jet four-momentum, while providing an accurate description of the constituents momenta, and an inference time comparable to that of a rule-based fast simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment and Mission Planning Capability For Quantitative Aerothermodynamic Flight Measurements Using Remote Imaging

High resolution calibrated infrared imagery of vehicles during hypervelocity atmospheric entry or sustained hypersonic cruise has the potential to provide flight data on the distribution of surface temperature and the state of the airflow over the vehicle. In the early 1980 s NASA sought to obtain high spatial resolution infrared imagery of the Shuttle during entry. Despite mission execution with a technically rigorous pre-planning capability, the single airborne optical system for this attempt was considered developmental and the scientific return was marginal. In 2005 the Space Shuttle Program again sponsored an effort to obtain imagery of the Orbiter. Imaging requirements were targeted towards Shuttle ascent; companion requirements for entry did not exist. The engineering community was allowed to define observation goals and incrementally demonstrate key elements of a quantitative spatially resolved measurement capability over a series of flights. These imaging opportunities were extremely beneficial and clearly demonstrated capability to capture infrared imagery with mature and operational assets of the US Navy and the Missile Defense Agency. While successful, the usefulness of the imagery was, from an engineering perspective, limited. These limitations were mainly associated with uncertainties regarding operational aspects of data acquisition. These uncertainties, in turn, came about because of limited pre-flight mission planning capability, a poor understanding of several factors including the infrared signature of the Shuttle, optical hardware limitations, atmospheric effects and detector response characteristics. Operational details of sensor configuration such as detector integration time and tracking system algorithms were carried out ad hoc (best practices) which led to low probability of target acquisition and detector saturation. Leveraging from the qualified success during Return-to-Flight, the NASA Engineering and Safety Center sponsored an assessment study focused on increasing the probability of returning spatially resolved scientific/engineering thermal imagery. This paper provides an overview of the assessment task and the systematic approach designed to establish confidence in the ability of existing assets to reliably acquire, track and return global quantitative surface temperatures of the Shuttle during entry. A discussion of capability demonstration in support of a potential Shuttle boundary layer transition flight test is presented. Successful demonstration of a quantitative, spatially resolved, global temperature measurement on the proposed Shuttle boundary layer transition flight test could lead to potential future applications with hypersonic flight test programs within the USAF and DARPA along with flight test opportunities supporting NASA s project Constellation.

Horvath, Thomas↗

Prospects for measuring the time variation of astrophysical neutrino sources at dark matter detectors

We study the prospects for measuring the time variation of solar and atmospheric neutrino fluxes at future large-scale xenon and argon dark matter detectors. For solar neutrinos, a yearly time variation arises from the eccentricity of Earth’s orbit and, for charged current interactions, from a smaller energy-dependent day-night variation due to flavor regeneration as neutrinos travel through Earth. For a 100-ton xenon detector running for ten years with a xenon-136 fraction of ≲ 0.1 % , in the electron recoil channel a time-variation amplitude of about 0.8% is detectable with a power of 90% and the level of significance of 10%. This is sufficient to detect time variation due to eccentricity, which has amplitude of ∼ 3 % . In the nuclear recoil channel, the detectable amplitude is about 10% under current detector resolution and efficiency conditions, and this generally reduces to about 1% for improved detector resolution and efficiency, the latter of which is sufficient to detect time variation due to eccentricity. Our analysis assumes both known and unknown periods. We provide scalings to determine the sensitivity to an arbitrary time-varying amplitude as a function of detector parameters. Identifying the time variation of the neutrino fluxes will be important for distinguishing neutrinos from dark matter signals and other detector-related backgrounds and extracting properties of neutrinos that can be uniquely studied in dark matter experiments. Published by the American Physical Society 2024

Zhuang, Yi (ORCID:0000000277138724)↗

Performance study of a 3×1×1 m 3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fatigue failure load indicator

An indicator for recording the load at which a fatigue specimen breaks during the last cycle of a fatigue test is described. A load cell is attached to the specimen which is alternately subjected to tension and compression loads. The output of the load cell which is proportional to the load on the specimen is applied to the input of a peak detector. Each time the specimen is subjected to a compression load, means are provided for applying a positive voltage to the rest of the peak detector to reset it. During the last cycle of the tension load the peak detector measures the maximum load on the specimen. Means are provided for disconnecting the load cell from the peak detector when there is a failure in the specimen.

Imig, L. A.↗

Generation-recombination noise in extrinsic photoconductive detectors

A theory of generation-recombination noise is presented and applied to the analysis of the performance limitations of extrinsic photoconductive detectors. The theory takes account both of the photoinduced generation of carriers and of thermal generation that is due to the finite temperature of the detector. Explicit formulas are derived that relate the detector response time, responsivity, and noise equivalent power to the material properties of the photoconductor (such as the presence of compensating impurities) and to the detector's operating conditions, such as its temperature and the presence of background radiation. The detector's performance is shown to degrade at high background levels because of saturation effects.

Brukilacchio, T. J.↗

MLA instruments and SWIR focal-plane technology

It is pointed out that next-generation sensors for earth observation will utilize Multispectral Linear Array (MLA) technology wherein linear detector arrays will scan the earth in pushbroom fashion. MLA instruments will permit a dramatic increase in detector dwell time, which can be utilized to improve spatial, spectral, and radiometric resolution. In connection with the considered applications for MLA sensors, the employed detector arrays should cover the visible, near-infrared, and shortwave infrared (SWIR) spectral bands. The present paper is mainly concerned with the development of mercury-cadmium-telluride focal-plane arrays for the SWIR spectral regime (1-2.5 microns). Attention is given to the requirements, design details regarding the detector array, the employed multiplexer technique, the hybrid concept, packaging, and the program status.

Brown, F. G.↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗