Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Longitudinal Changes in Immune Activation Serum Biomarkers Prior to Diagnosis and Risk of B-cell NHL Subtypes

To examine the contribution of B-cell activation molecules to B-cell follicular lymphoma (FL) and diffuse large B-cell lymphoma (DLBCL), a prospective study was conducted using pre-diagnosis serial serum samples from the US Department of Defense Serum Repository. Each case (n = 142 FL, n = 211 DLBCL) was matched to two controls on age, gender, race, military branch, and blood collection dates. Immune activation molecules (IL1β, IL2, IL4, IL5, IL6, IL10, IL12, CXCL13, IL8, TNFα, IFNγ, GM-CSF, VEGF, sCD30, IgE) were quantified using ELISA or multiplex immunometric (Luminex) assay. Longitudinal data were analyzed using linear mixed modeling. As serial specimens were collected over several years before diagnosis, we evaluated the temporal dynamics of these markers. Increased serum levels of sCD30, CXCL13, and to a lesser extent IL10, were associated with both FL and DLBCL in cases compared with controls, with a median follow-up of 5.5 years from the earliest specimen collection to diagnosis date. Significant increasing sCD30 and CXCL13 trajectories for FL and DLBCL subtypes were noted starting at the earliest time points and with IL10 levels increasing significantly at time points closer to diagnosis. In conclusion, these results suggest that sCD30, CXCL13, and IL10 may contribute to the etiology of FL and DLBCL and are potential biomarkers for these non–Hodgkin lymphoma subtypes. The increasing trajectories of the B-cell activation molecules, sCD30, CXCL13, and to a lesser extent IL10, may indicate early disease-induced effects or reflect the chronic stimulation of B-cells that promotes the development of FL and DLBCL subtypes.

60 APPLIED LIFE SCIENCES↗

A New Inelastic Neutron Spectrometer HODACA

In this study, a new multiplex-type inelastic neutron scattering spectrometer, HOrizontally Defocusing Analyzer Concurrent data Acquisition spectrometer (HODACA), was recently developed and built at the C1-1 cold neutron beam port in the neutron source reactor JRR-3 at Japan Atomic Energy Agency. The spectrometer is suitable for dynamics measurements in the energy range of -1 meV ≲ ℏω ≲ 7 meV, catering to a broad array of research fields in physics and material science. HODACA combines 24 detectors and 132 pieces of analyzer crystals and has an estimated measurement efficiency that is 70 times greater than the existing conventional triple-axis spectrometer at the C1-1 beam port. The concept, design, specification, and results of commissioning experiments are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal kinetic inductance detectors for millimeter-wave detection

Thermal Kinetic-Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of millimeter-wave instruments. In this paper, we first discuss the expected noise sources in TKIDs and derive the limits where the phonon noise contribution dominates over the other detector noise terms: generation–recombination, amplifier, and two-level system noise. Second, we characterize aluminum TKIDs in a dark environment. We present measurements of TKID resonators with quality factors of about 10 5 at 80 mK. We also discuss the bolometer thermal conductance, heat capacity, and time constants. These were measured by the use of a resistor on the thermal island to excite the bolometers. These dark aluminum TKIDs demonstrate a noise equivalent power, NEP = 2 × 10 − 17 W / Hz , with a 1 / f knee at 0.1 Hz, which provides background noise limited performance for ground-based telescopes observing at 150 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SPT-3G+ Experiment on the South Pole Telescope

Observations of the cosmic microwave background (CMB) offer an unparalleled opportunity to advance our understanding of fundamental physics. SPT-3G+ is an upgraded receiver for the arcminute-resolution South Pole Telescope (SPT) that plans to deploy in late 2028. SPT-3G+ will increase the CMB mapping speed of SPT by nearly an order of magnitude over the currently installed SPT-3G receiver. SPT-3G+ will have ~24,000 transition-edge sensor (TES) bolometers in two frequency bands with center frequencies at 95 GHz and 150 GHz that will be read out with microwave multiplexing. SPT-3G+ will measure the CMB lensing spectrum and galaxy clusters to constrain the growth of structure, dark matter, and dark energy. SPT-3G+ will also reach critical thresholds on inflationary constraints by combining data with BICEP/Keck, forming the South Pole Observatory (SPO). BICEP/Keck has deep degree-angular scale measurements but is currently delensing-limited, while SPT-3G+ will provide deep lensing measurements. Forecasts show that SPO will reach an uncertainty on the tensor-to-scalar ratio $r$ of $\sigma(r) \sim 1.2\times 10^{-3}$ by 2034. A detection at these levels would provide evidence of inflation and probe new physics at grand unified theory energy scales, while no detection would exclude large classes of models and shift the scientific paradigm describing the early universe. I will give an overview of SPT-3G+ including its design and current status.

Simon, Sara M. [Fermilab] (ORCID:0009000006683584)↗

Spin-Photon Entanglement of a Single Er 3 + Ion in the Telecom Band

Entanglement between photons and a quantum memory is a key component of quantum repeaters, which allow long-distance quantum entanglement distribution in the presence of fiber losses. Spin-photon entanglement has been implemented with a number of different atomic and solid-state qubits with long spin coherence times, but none directly emit photons into the 1.5 − μ m telecom band where losses in optical fibers are minimized. Here, we demonstrate spin-photon entanglement using a single rare earth ion in the solid-state Er 3 + coupled to a silicon nanophotonic cavity, which directly emits photons at 1532.6 nm. We infer an entanglement fidelity of 73(3)% after propagating through 15.6 km of optical fiber. This work opens the door to large-scale quantum networks based Er 3 + ions, leveraging scalable silicon device fabrication and spectral multiplexing. Published by the American Physical Society 2025

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-shot complete spatiotemporal measurement of terawatt laser pulses

In this work, we demonstrate, for the first time, a single-shot, complete spatiotemporal measurement of pulses from a terawatt-scale, multi-stage-amplified, low repetition-rate laser source. The ultrashort pulse electric field, E(x,y,z,t), is spatiotemporally complex due to distortions that accrue from multiple chirped-pulse amplifiers, which requires a complete characterization. Meanwhile, the instability of the laser source introduces field profiles that vary significantly from pulse to pulse, which, together with the low repetition-rate (15 shots/hour), requires the use of a single-shot measurement technique. To accomplish the measurements, we used a wavelength-multiplexed, digital-holographic technique called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, specially tailored to measure picosecond pulses at a wavelength of about 1 μm. Specifically, individual pulses from the compact multipulse terawatt laser were measured, with up to 0.3 J per shot of energy and ~2 ps pulse durations, at 1052 nm. With these measurements, we characterized several major spatiotemporal distortions that affect the peak intensity at the laser focus, as well as the pulse-shape instability on a shot-to-shot basis. Our technique allows detailed diagnosis of laser pulses (especially high-order spatiotemporal distortions) and provides straightforward four-dimensional animations of pulse propagation to a focus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Warping Functions Design for Long Warped ZT-DFT-s-OFDM

Time-frequency warped waveform is a novel type of well-contained waveform composed of raised cosine (RC) pulses with roll-off factors profile customized for spectrally efficient signal containment. The waveform is suited for massive machine-type communication (mMTC), and Internet-of-Things (IoT) applications. The paper is a follow-up to the original work of time-frequency warped waveforms; here, we are proposing a warping function suited for length-independent symbols, which is missing from the previous work. The paper proposes the design steps starting from a piecewise warping function with parts of straight segments and other curved parts. A maximum Out-of-band leakage is used as a criterion to determine the warping function parameters. The roll-off factors profile determined in the previous study is used as a minimum bound for the leakage limits. Gains are presented over Windowed Zero-tail Discrete Fourier Transform-spread-Orthogonal Frequency Division Multiplexing (ZT-DFT-s-OFDM) in the simulations section.

Ibrahim, Mostafa↗

Multi-Functional Distributed Fiber Sensors for Pipeline Monitoring and Methane Detections. Final Report

As an abundant and cheap fossil energy source, natural gas has become a significant energy supply to support the United States’ economy. However, the large-scale extraction and utilization of natural gas also impose significant challenges on methane leakage. This problem is exacerbated by aging gas utility delivery systems, including interstate high-pressure pipelines, storage, and transmission facilities. This project aims to develop a cost-effective fiber optical sensing method that can perform multi-parameter real-time measurements of natural gas pipelines across long interrogation distances up to 100 km with 1-meter spatial resolution. This sensing tool can evaluate overall pipeline efficiency and reduce methane emissions for mid-stream methane infrastructures. To accomplish this objective, research and development efforts funded by this project have resulted in the following accomplishments: This project successfully has developed new functional sensory polymer materials using Metal-Organic Frameworks (MOFs) that can be coated on optical fiber through the reel-to-reel coating process. Functional polymer-coated optical fibers can perform sensitive methane detection through evanescence wave interaction and strain-based measurements to achieve 1% detection sensitivities. The new sensors fibers support both distributed measurements and multiplexed fiber sensors array for multi-point measurements. This project developed and optimized a new multi-core optical fiber that supports simultaneous and distributed measurements of strain and temperatures with 1-meter spatial resolutions across up to 100-km interrogation distance. This new fiber, combined with sensory polymercoated fiber, could perform both distributed temperature and methane detections. This project developed a new artificial intelligence big data algorithm approach that can effectively analyze high-resolution data harnessed by distributed fiber sensors to protect natural gas pipelines against external threats and detect internal defects induced by corrosion. Working with our industry partner, this project developed new optical fibers that support fiber sensor fabrications through polymer coating after the fibers are drawn. These new fibers eliminate the need for direct sensor fabrication when the fiber is fabricated on a fiber draw tower, which drastically expands fiber sensors' applicability. This research project has significantly advanced the distributed fiber sensing technology. It will dramatically increase the applicability and adaptability of distributed fiber sensors for a wide array of applications in energy, sustainability, and environmental science, including structural health monitoring of natural gas pipelines, oil infrastructures, hydrogen facilities, and environmental monitoring of carbon storage sites, water supply systems, and others.

03 NATURAL GAS↗

Covalent Surface Modification Effects on Single‐Walled Carbon Nanotubes for Targeted Sensing and Optical Imaging

Abstract Optical nanoscale technologies often implement covalent or noncovalent strategies for the modification of nanoparticles, whereby both functionalizations are leveraged for multimodal applications but can affect the intrinsic fluorescence of nanoparticles. Specifically, single‐walled carbon nanotubes (SWCNTs) can enable real‐time imaging and cellular delivery; however, the introduction of covalent SWCNT sidewall functionalizations often attenuates SWCNT fluorescence. Recent advances in SWCNT covalent functionalization chemistries preserve the SWCNT's pristine graphitic lattice and intrinsic fluorescence, and here, such covalently functionalized SWCNTs maintain intrinsic fluorescence‐based molecular recognition of neurotransmitter and protein analytes. The covalently modified SWCNT nanosensor preserves its fluorescence response towards its analyte for certain nanosensors, presumably dependent on the intermolecular interactions between SWCNTs or the steric hindrance introduced by the covalent functionalization that hinders noncovalent interactions with the SWCNT surface. These SWCNT nanosensors are further functionalized via their covalent handles with a targeting ligand, biotin, to self‐assemble on passivated microscopy slides, and these dual‐functionalized SWCNT materials are explored for future use in multiplexed sensing and imaging applications.

Chio, Linda↗

Coherent electronic-vibrational dynamics in deuterium bromide probed via attosecond transient-absorption spectroscopy

Ultrafast laser excitation can trigger multiplex coherent dynamics in molecules. Here, we report attosecond transient-absorption experiments addressing simultaneous probing of electronic and vibrational dynamics in a prototype molecule, deuterium bromide (DBr), following its strong-field ionization. Electronic and vibrational coherences in the ionic X$^2\Pi_{3/2}$ and X$^2\Pi_{1/2}$ states are characterized in the Br-$3d$ core-level absorption spectra via quantum beats with 12.6-fs and 19.9-fs periodicities, respectively. Polarization scans reveal that the phase of the electronic quantum beats depends on the probe direction, experimentally showing that the coherent electronic motion corresponds to the oscillation of the hole density along the ionization-field direction. The vibrational quantum beats are found to maintain a relatively constant amplitude, whereas the electronic quantum beats exhibit a partial decrease in time. Quantum wave-packet simulations show that the decoherence effect from the vibrational motion is insignificant because of the parallel relation between the X$^2\Pi_{3/2}$ and X$^2\Pi_{1/2}$ potentials. Finally, a comparison between the DBr and HBr results suggests that rotation motion is responsible for the decoherence since it leads to initial alignment prepared by the strong-field ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Expanding the genetic toolkit: adenine and cytosine base editors for gene disruption in Aspergillus niger

Despite revolutionizing fungal genetic engineering, conventional CRISPR/Cas9-mediated knockouts rely on DNA double-strand breaks (DSBs), which can cause unwanted insertions and deletions, chromosomal abnormalities, and cytotoxicity. Base editors such as adenine base editors (ABEs), which convert A‧T to G‧C, and cytosine base editors (CBEs), which convert C‧G to T‧A, offer a safer alternative by enabling predictable, target-specific single-nucleotide changes without introducing DSBs. To overcome the limitations of traditional genome editing in filamentous fungi, we developed efficient base-editing systems in Aspergillus niger . For the first time, we constructed an ABE in A. niger , achieving up to 80% editing efficiency and inducing predictable A-to-G mutations at the intended intron sites, disrupting gene function through mRNA mis-splicing. We also developed a highly efficient CBE system, capable of introducing premature stop codons with 50–100% efficiency. To broaden the editing scope, we implemented a Cas9-NG variant recognizing a relaxed PAM sequence requiring only a single guanine (G), enabling editing at start codons and splice sites. Leveraging this expanded scope, we established gene disruption approaches by targeting start codons via ABE-mediated A-to-G conversions (ATG-to-GTG and ATG-to-ACG) and CBE-mediated C-to-T conversion (ATG-to-ATA). Additionally, our base-editing systems enable multiplex gRNA delivery and marker-free editing of multiple genes. Collectively, the scope-expanding strategies increase the number of genes targetable for disruption by base-editing in A. niger by 26.3% and enable near-complete coverage of 96% of the coding genes. Overall, this work demonstrates the potential of ABE and CBE systems as versatile, efficient, and safer alternatives to DSBs-based gene disruption in filamentous fungi.

Aspergillus↗

Nitrogen thermometry in an inductively coupled plasma torch using broadband nanosecond coherent anti-Stokes Raman scattering

The development of atmospheric hypersonic flight and re-entry capabilities requires the characterization of the thermo-chemical state of representative test environments. This study demonstrates the usage of multiplex nanosecond N 2 coherent anti-Stokes Raman scattering (CARS) to measure temperatures in an atmospheric, high-temperature (>6000K), air plasma plume, generated by an inductively coupled plasma torch. These are some of the highest temperatures ever accessed via gas-phase CARS, to our knowledge. Temperatures of N 2 in the equilibrium plasma plume are determined via theoretical fits to measured CARS spectra. We discuss the practical implementation of CARS at very high temperatures, including the scaling of the N 2 CARS signal strength from 300 to 6700 K, where the expected peak signal from the high-temperature plasma torch gases is two orders of magnitude less than commonly encountered in combustion environments. An intensified CCD camera enables single-laser-shot detection at temperatures as high as 6200 K, by increasing sensitivity and providing a time gate against intense background luminosity. We also discuss the impacts of unwanted two-beam CARS contributions from outside the nominal three-beam measurement volume. We present mean axial and radial temperature profiles, as well as time-series data derived from both single-laser-shot and accumulated CARS spectra. The single-laser-shot precision is 1.7%–2.6% at temperatures of 3500 to 6200 K. The presented results pave the way for the use of CARS at very high temperatures and the measurement of spatially resolved interface processes in high-enthalpy flows.

Fries, Dan (ORCID:0000000229513294)↗

Quantification of Metabolic Products from Microbial Hosts in Complex Media Using Optically Diffracting Hydrogels

In this work, we herein describe a highly versatile platform approach for the in situ and real-time screening of microbial biocatalysts for enhanced production of bioproducts using photonic crystal hydrogels. This approach was demonstrated by preparing optically diffracting films based on polymerized N-isopropylacrylamide that contracted in the presence of alcohols and organic acids. The hydrogel films were prepared in a microwell plate format, which allows for high-throughput screening, and characterized optically using a microwell plate reader. While demonstrating the ability to detect a broad range of relevant alcohols and organic acids, we showed that the response of the films correlated strongly with the octanol-water partition coefficient (log P) of the analyte. Differences in the secretion of ethanol and succinic acid from strains of Zymomonas mobilis and Actinobacillus succinogenes, respectively, were further detected via optical characterization of the films. These differences, which in some cases were as low as ~3 g/L, were confirmed by high-performance liquid chromatography, thereby demonstrating the sensitivity of this approach. Our findings highlight the potential utility of this multiplexed approach for the detection of small organic analytes in complex biological media, which overcomes a major challenge in conventional optical sensing methods.

09 BIOMASS FUELS↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace-Level, Multi-Gas Detection for Food Quality Assessment Based on Decorated Silicon Transistor Arrays

Multiplexed gas detection at room temperature is critical for practical applications, such as for tracking the complex chemical environments associated with food decomposition and spoilage. Here, an integrated array of multiple silicon-based, chemical-sensitive field effect transistors (CSFETs) is presented to realize selective, sensitive, and simultaneous measurement of gases typically associated with food spoilage. CSFETs decorated with sensing materials based on ruthenium, silver, and silicon oxide are used to obtain stable room-temperature responses to ammonia (NH 3 ), hydrogen sulfide (H 2 S), and humidity, respectively. For example, one multi-CSFET sensor signal changes from its baseline by 13.34 in response to 1 ppm of NH 3 , 724.45 under 1 ppm H 2 S, and 23.46 under 80% relative humidity, with sensitive detection down to 10 ppb of NH 3 and H 2 S. To demonstrate this sensor for practical applications, the CSFET sensor array is combined with a custom-printed circuit board into a compact, fully integrated, and portable system to conduct real-time monitoring of gases generated by decomposing food. By using existing silicon-based manufacturing methodologies, this room-temperature gas sensing array can be fabricated reproducibly and at low cost, making it an attractive platform for ambient gas measurement needed in food safety applications.

36 MATERIALS SCIENCE↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗