Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

DES meets Gaia: discovery of strongly lensed quasars from a multiplet search

We report the discovery, spectroscopic confirmation and first lens models of the first two, strongly lensed quasars from a combined search in WISE and Gaia over the DES footprint. Their Einstein radii span a range between ≈2.0 arcsec and ≈0.4 arcsec. Two of these (WGD2038-4008, RA = 20:38:02.65, Dec. = -40:08:14.64; WGD2021-4115, RA = 20:21:39.45, Dec. = -41:15:57.11) also have confirmed deflector redshifts. The four-image lens WGD2038-4008, with source and deflector redshifts s = 0.777 ± 0.001 and zl = 0.230 ± 0.002, respectively, has a deflector with radius R eff ≈ 3.4 arcsec, stellar mass $\log(M_{\star}/M_{\odot}) = 11.64^{+0.20}_{-0.43}$, and shows extended isophotal shape variation. Simple lens models yield Einstein radii $R_{\rm E}=(1.30\pm0.04)^{\prime\prime},$ axis ratio $q=0.75\pm0.1$ (compatible with that of the starlight) and considerable shear-ellipticity degeneracies. The two-image lens WGD2021-4115 (r.a.=20:21:39.45, dec.=--41:15:57.11) has $z_{s}=1.390\pm0.001$ and $z_l = 0.335 \pm 0.002$, and Einstein radius $R_{\rm E} = (1.1\pm0.1)^{\prime\prime},$ but higher-resolution imaging is needed to accurately separate the deflector and faint quasar image. Finally, we also show high-rank candidate doubles selected this way, some of which have been independently identified with different techniques, and discuss a DES+WISE quasar multiplet selection.

79 ASTRONOMY AND ASTROPHYSICS↗

Sparse Bayesian mass mapping with uncertainties: peak statistics and feature locations

ABSTRACT Weak lensing convergence maps – upon which higher order statistics can be calculated – can be recovered from observations of the shear field by solving the lensing inverse problem. For typical surveys this inverse problem is ill-posed (often seriously) leading to substantial uncertainty on the recovered convergence maps. In this paper we propose novel methods for quantifying the Bayesian uncertainty in the location of recovered features and the uncertainty in the cumulative peak statistic – the peak count as a function of signal-to-noise ratio (SNR). We adopt the sparse hierarchical Bayesian mass-mapping framework developed in previous work, which provides robust reconstructions and principled statistical interpretation of reconstructed convergence maps without the need to assume or impose Gaussianity. We demonstrate our uncertainty quantification techniques on both Bolshoi N-body (cluster scale) and Buzzard V-1.6 (large-scale structure) N-body simulations. For the first time, this methodology allows one to recover approximate Bayesian upper and lower limits on the cumulative peak statistic at well-defined confidence levels.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence procedure for efficient quantum-state tomography

I show that in tomographic experiments, the measurement of a small set of observables suffices to confirm or incrementally amend prior expectations with a high degree of confidence. To this end, I adapt the evidence procedure, an estimation technique used in classical image reconstruction, for use in quantum-state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Terahertz time-domain spectroscopy imaging of pancreatic ductal adenocarcinoma tissues

Pancreatic ductal adenocarcinoma (PDAC) ranks among the malignancies with the highest fatality and morbidity rates. This is predominantly attributable to an absence of understanding the intricate and diverse microenvironment of the tumor. We use terahertz time-domain spectroscopy (THz-TDS) imaging in transmission geometry to probe ex-vivo the heterogenous microenvironment of the genetically modified murine PDAC tissue that closely resembles the PDAC heterogeneity in human malignancy. We introduced a maximum a-posteriori probability estimation algorithm to objectively the tumor’s heterogenous microenvironment using the average values of refractive index and absorption coefficient within the useable terahertz bandwidth as imaging markers. Furthermore, direct comparison of stained histopathologic images and the refractive index and the absorption coefficient high-resolution, two dimensional maps of the same PDAC samples confirms the high potential of the THz-TDS method for tumor tissue characterization.

absorption↗

Comparative Assessment of U-Net-Based Deep Learning Models for Segmenting Microfractures and Pore Spaces in Digital Rocks

Segmentation of high-resolution X-ray microcomputed tomography (µCT) images is crucial in digital rock physics (DRP), affecting the characterization and analysis of microscale phenomena in the porous media. The complexity of geological structures and nonideal scanning conditions pose significant challenges to conventional image segmentation approaches. Motivated by the recent increasing popularity of deep learning (DL) techniques in image processing, this work undertakes a comparative study of DL models, specifically U-Net and its variants, for segmenting multiple targets with distinguished features in digital rocks, including discrete fracture networks (DFNs), pore spaces, and solid rock. Particularly, DFNs have a smaller volumetric fraction over others, bringing in a substantial challenge of imbalanced segmentation. The primary focus is to evaluate the architecture and feature enhancement strategies of various DL models, including U-Net, attention U-Net, residual U-Net, U-Net++, and residual U-Net++. The models were designed as 2.5D, utilizing a central 2D image and its two adjacent upper and lower 2D images as input to provide a pseudo-3D context. In addition, because the ground truth of segmentation was unknown for real-world digital rocks, we created a benchmark data set following the inverse operations of segmentation. The data synthesis started from the label images (i.e., solid rock, pore spaces, and DFNs), followed by simulating partial volume blurring, adding random background noise, and introducing ring artifacts to mimic real raw X-ray µCT images. The data set, which included various rock types (i.e., sandstone and artificial data), scanning resolution, and magnitudes of noise and artifacts, was divided into training and testing data sets with a 90% and 10% ratio, respectively. Moreover, in addition to the conventional pixel-wise evaluation metrics, the physics-based metric of the lattice-Boltzmann method (LBM) simulated permeability provided more comprehensive assessments. The results demonstrated that the residual connections, nested architectures, and redesigned skip connections contribute to the model performance and give the residual U-Net++ the highest accuracy. The improvements were mainly on the boundaries and small targets, especially the DFNs, which dominate the interconnectivity and therefore affect the permeability greatly. This study also rigorously evaluated the efficiency and generalization of each model, demonstrating that the sophisticated architectures achieved excellent practicability and maintained robust performance on completely unseen data, ensuring their suitability for diverse and challenging DRP applications.

58 GEOSCIENCES↗

Gold Nanoparticles AuNP Decorated on Fused Graphene-like Materials for Application in a Hydrogen Generation

The search for a sustainable, alternative fuel source to replace fossil fuels has led to an increased interest in hydrogen fuel. This combustible gas is not only clean-burning but can readily be produced via the hydrolysis of sodium borohydride. The main drawback of this reaction is that the reaction occurs relatively slowly and requires a catalyst to improve efficiency. This study explored a novel composite material made by combining gold nanoparticles and fused graphene-like materials (AuFGLM) as a catalyst for generating hydrogen via sodium borohydride. The novel fused graphene-like material (FGLM) was made with a sustainable dextrose solution and by using a pressure-processing method. Imaging techniques showed that FGLM appears to be an effective support template for nanoparticles. Transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and Raman spectroscopy were used to characterize and determine the size, shape, and structure of nanoparticles and composites. The TEM study characterized the fused carbon backbone as it began to take on a rounder shape. The TEM images also revealed that the average diameter of the gold nanoparticle was roughly 23 nm. The FTIR study confirmed O-H, C-C, and C=O as functional groups in the materials. The EDS analysis showed that the composite contained approximately 6.3% gold by weight. The crystal structures of FGLM and AuFGLM were identified via P-XRD analysis. Various reaction conditions were used to test the catalytic ability of AuFGLM, including various solution pHs, temperatures, and doses of NaBH 4 . It was observed that optimal reaction conditions included high temperature, an acidic solution pH, and a higher dose of NaBH 4 . The activation energy of the reaction was determined to be 45.5 kJ mol -1 , and it was found that the catalyst could be used multiple times in a row with an increased volume of hydrogen produced in ensuing trials. The activation energy of this novel catalyst is competitive compared to similar catalysts and its ability to produce hydrogen over multiple uses makes the material an exciting choice for catalyzing the hydrolysis of NaBH 4 for use as a hydrogen fuel source.

08 HYDROGEN↗

WISE PHOTOMETRY FOR 400 MILLION SDSS SOURCES

We present photometry of images from the Wide-Field Infrared Survey Explorer (WISE) of over 400 million sources detected by the Sloan Digital Sky Survey (SDSS). We use a “forced photometry” technique, using measured SDSS source positions, star–galaxy classification, and galaxy profiles to define the sources whose fluxes are to be measured in the WISE images. We perform photometry with The Tractor image modeling code, working on our “unWISE” coaddds and taking account of the WISE point-spread function and a noise model. The result is a measurement of the flux of each SDSS source in each WISE band. Many sources have little flux in the WISE bands, so often the measurements we report are consistent with zero given our uncertainties. However, for many sources we get 3σ or 4σ measurements; these sources would not be reported by the “official” WISE pipeline and will not appear in the WISE catalog, yet they can be highly informative for some scientific questions. In addition, these small-signal measurements can be used in stacking analyses at the catalog level. The forced photometry approach has the advantage that we measure a consistent set of sources between SDSS and WISE, taking advantage of the resolution and depth of the SDSS images to interpret the WISE images; objects that are resolved in SDSS but blended together in WISE still have accurate measurements in our photometry. Our results, and the code used to produce them, are publicly available at http://unwise.me.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for Subsecond Stellar Variability with Wide-field Star Trails and Deep Learning

We present here a method that enables wide-field ground-based telescopes to scan the sky for subsecond stellar variability. The method has operational and image processing components. The operational component takes star trail images. Each trail serves as a light curve for its corresponding source and facilitates subexposure photometry. We train a deep neural network to identify stellar variability in wide-field star trail images. We use the Large Synoptic Survey Telescope Photon Simulator to generate simulated star trail images and include transient bursts as a proxy for variability. The network identifies transient bursts on timescales down to 10 ms. We argue that there are multiple fields of astrophysics that can be advanced by the unique combination of time resolution and observing throughput that our method offers.

79 ASTRONOMY AND ASTROPHYSICS↗

Object Classification at the Nearby Supernova Factory

We present the results of applying new object classification techniques to the supernova search of the Nearby Supernova Factory. In comparison to simple threshold cuts, more sophisticated methods such as boosted decision trees, random forests, and support vector machines provide dramatically better object discrimination: we reduced the number of nonsupernova candidates by a factor of 10 while increasing our supernova identification efficiency. Methods such as these will be crucial for maintaining a reasonable false positive rate in the automated transient alert pipelines of upcoming large optical surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-90: Medical Physicists' Implication in Diagnostic CT in Switzerland: Results of After One Year of Experience

Purpose: Since January 1st 2008, the Swiss ordinance on radiation protection requires the involvement of a medical physicist to support the optimization process of medical imaging techniques using ionizing radiation. After a long process of implementation, this requirement is satisfied all over the country since the beginning of 2013. The goal of this contribution is to summarize the main results obtained in this first year of experience in CT. Methods: We assessed the output and clinical use of 45 CT units using a three-pronged approach. First, we assessed the output of the device (CTDIvol, primary beam collimation and HU in water at different tube tensions). Secondly, we characterized the local chest and abdomen acquisition and reconstruction protocols using the Catphan 600 phantom. Lastly, we assessed the clinical use of the machine by analyzing an extract of a dozen clinical examinations per unit. Results: 9 out of 45 units had incorrect collimator settings, e.g. 4mm instead of 1mm. We witnessed also a large spread in reconstruction parameters, especially for reconstructed slice thickness, thus showing notable variations in low contrast detectability performances. Clinical practice is also clearly spread out. For example, estimated patient effective dose per abdomen examination lies at 18.7+/−12.7mSv (min: 2.0mSv — max: 112.0mSv). Chest and brain scans have a narrower dispersion, but patient effective dose is also spread by about a factor of 10 to 20. Conclusion: The spread in clinical practice being fairly large, it appears of crucial importance to collaborate more closely with radiologists and technologists to assess it. The lack of statistical precision will imply that we analyze clinical practice according to a specific medical demand rather than an anatomical region. Furthermore, low contrast sensitivity (LCD) being a crucial parameter, an objective method using a model observer will be used to assess LCD.

60 APPLIED LIFE SCIENCES↗

Process-Structure-Property Modeling for Severe Plastic Deformation Processes Using Orientation Imaging Microscopy and Data-Driven Techniques

Machining is a severe plastic deformation process, wherein the workpiece material is subjected to high deformation rates and temperatures. During metal machining, the dynamic recrystallization mechanism causes grain refinement into the sub-micron range. In this study, we investigate the microstructure evolution of oxygen-free high conductivity copper (OFHC Cu) subject to a machining process where the cutting speed and rake angle are controlled to manipulate the process strain, strain rate, and temperatures. Microstructures of the deformed chips are quantified using orientation imaging microscopy and novel statistical descriptors that capture the morphology and local lattice misorientations generated during the several mechanistic stages of the dynamic recrystallization process. Mechanical properties of the resulting chips are quantified using spherical nanoindentation protocols. A multiple output Gaussian process regression model is used to simultaneously model the structure-property evolution, which differs from more common approaches that establish such relationships sequentially. This modeling strategy is particularly attractive since it can flexibly provide both structure and property uncertainty estimates. In addition, the statistical modeling framework allows for the inclusion of multi-fidelity data. The statistical metrics utilized serve as efficient microstructure descriptors, which retain the physics of the observed structures without having to introduce ad hoc microstructure feature definitions.

36 MATERIALS SCIENCE↗

An innovative digital image correlation technique for in-situ process monitoring of composite structures in large scale additive manufacturing

As additive manufacturing (AM) continues to develop and become a standardized manufacturing method, there will be a continued need to provide in-situ monitoring during the manufacturing of polymer composite printed components. Thermal residual stress is a primary cause of failures such as interlayer disbonds or delamination, micro cracking, and dimensional instability, which can occur during or after the build. Here, we report a novel digital image correlation (DIC) adaptation to monitor thermal residual stresses during the entire print process for large-scale AM. In this work, DIC has been investigated (a) by the natural speckle produced by the polymer surface for correlation, (b) to monitor AM build, and (c) to evaluate the effect of thermal residual stress on warpage of the printed component. The natural speckle pattern of the AM material resulted in a respectable 3.57% error compared to the traditional painted speckle pattern of 3.05% error. DIC measured a 190% increase in vertical displacement at the edge of the wall compared to the center, indicating warpage during AM. This work is a step towards a non-intrusive residual stress measuring technique using DIC for large-scale AM.

36 MATERIALS SCIENCE↗

Optimization of oncological {sup 18}F-FDG PET/CT imaging based on a multiparameter analysis

Purpose: This paper describes a method to achieve consistent clinical image quality in {sup 18}F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. Methods: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. Results: The adoption of different schemes for three body mass ranges (<60 kg, 60–90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. Conclusions: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Generalized Optimization of High-Capacity Compressive Imaging Systems

One of the greatest challenges in applying compressive sensing (CS) signal processing techniques to electromagnetic imaging applications is designing a sensing matrix that has good reconstruction capabilities. Compressive reflector antennas (CRAs) are a class of antennas that have been shown to provide enhanced image reconstruction performance over traditional reflector antennas (TRAs) when CS techniques are employed. In this article, we present a unified CRA design method, which considers both the sensing capacity and efficiency of the antenna and can be used for both compressive imaging and multiple-input multiple-output (MIMO) communication applications. The unified design method is assessed for a CRA configuration in which dielectric scatterers are added to the surface of a TRA. The design results demonstrate the ability of the unified design method to enhance the CS reconstruction capabilities of the CRA.

42 ENGINEERING↗

Measurement and image processing evaluation of surface modifications of dental implants G4 pure titanium created by different techniques

Foreign substances and organic tissue interaction placed into the jaw in order to eliminate tooth loss involves a highly complex process. Many biological reactions take place as well as the biomechanical forces that influence this formation. Osseointegration denotes to the direct structural and functional association between the living bone and the load-bearing artificial implant's surface. Taking into consideration of the requirements in the manufacturing processes of the implants, surface characterizations with high precise measurement techniques are investigated and thus long-term success of dental implant is emphasized on the importance of these processes in this study. In this research, the detailed surface characterization was performed to identify the dependence of the manufacturing techniques on the surface properties by using the image processing methods and using the scanning electron microscope (SEM) for morphological properties in 3D and Taylor Hobson stylus profilometer for roughness properties in 2D. Three implant surfaces fabricated by different manufacturing techniques were inspected, and a machined surface was included into the study as a reference specimen. The results indicated that different surface treatments were strongly influenced surface morphology. Thus 2D and 3D precise inspection techniques were highlighted on the importance for surface characterization. Different image analyses techniques such as Dark-light technique were used to verify the surface measurement results. The computational phase was performed using image processing toolbox in Matlab with precise evaluation of the roughness for the implant surfaces. The relationship between the number of black and white pixels and surface roughness is presented. FFT image processing and analyses results explicitly imply that the technique is useful in the determination of surface roughness. The results showed that the number of black pixels in the image increases with increase in surface roughness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark energy survey year 3 results: weak lensing shape catalogue

ABSTRACT We present and characterize the galaxy shape catalogue from the first 3 yr of Dark Energy Survey (DES) observations, over an effective area of 4143 deg2 of the southern sky. We describe our data analysis process and our self-calibrating shear measurement pipeline metacalibration, which builds and improves upon the pipeline used in the DES Year 1 analysis in several aspects. The DES Year 3 weak-lensing shape catalogue consists of 100 204 026 galaxies, measured in the riz bands, resulting in a weighted source number density of neff = 5.59 gal arcmin−2 and corresponding shape noise σe = 0.261. We perform a battery of internal null tests on the catalogue, including tests on systematics related to the point spread function (PSF) modelling, spurious catalogue B-mode signals, catalogue contamination, and galaxy properties.

79 ASTRONOMY AND ASTROPHYSICS↗