Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effect of Insertion of a Heat Flux Gage into a High Temperature Cylindrical Blackbody Cavity on the Gage

Detailed transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels. These heat flux levels are of interest to the reciprocating and gas turbine engine industries as well as the aerospace industry. The transient models are based on existing, experimentally validated steady state models of a cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system, time-varying electrical current that passes through the resistance heated blackbody, and the resulting heating of the heat flux gage. Heat fluxes computed using detailed transient models were compared to experimental measurements. The calculated and measured transient heat fluxes agreed to within 2 percent, indicating that the models had captured the physical phenomena in the transient calibration. The predicted and measured transient heat fluxes were also compared for two different blackbody configurations. The effect of convection on the blackbody extension was evaluated and found to be a minor factor.

Abdelmessih, Amanie N.↗

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗

Advanced synthetic aperture radar for remote sensing

A program initiated by NASA was formed to address some key earth resources synthetic aperture radar (SAR) needs. Major steps in the SAR system development are summarized, and the objective of the advanced SAR (ASAR) program is defined. The program rationale and specific objectives are discussed, including system calibration, wide-band technique evaluation, a system resolution of 10 m or better at 45 deg, and an airborne system to cover four bands within 1 to 10 GHz. The ASAR conceptual system design, consisting of a modulator, transmitter, antenna, receiver, calibrator, and data system modules is also presented, and ASAR capability expansions are discussed. The program, scheduled for 1983, will provide a data source which is not available to applications investigations at this time, and will produce design approaches that are flexible and multimission to the maximum extent for application to a Shuttle or a freeflyer system.

Krishen, K.↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation

A system for wirelessly measuring the volume of fluid in tanks at non-horizontal orientation is predicated upon two technologies developed at Langley Research Center. The first is a magnetic field response recorder that powers and interrogates magnetic field response sensors [ Magnetic Field Response Measurement Acquisition System, (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28]. Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields and when electrically active respond with their own magnetic fields whose attributes are dependent upon the magnitude of the physical quantity being measured. The response recorder facilitates the use of the second technology, which is a magnetic field response fluid-level sensor ["Wireless Fluid- Level Sensors for Harsh Environments," (LAR-17155), NASA Tech Briefs, Vol. 33, No. 4 (April 2009), page 30]. The method for powering and interrogating the sensors allows them to be completely encased in materials (Fig. 1) that are chemically resilient to the fluid being measured, thereby facilitating measurement of substances (e.g., acids, petroleum, cryogenic, caustic, and the like) that would normally destroy electronic circuitry. When the sensors are encapsulated, no fluid (or fluid vapor) is exposed to any electrical component of the measurement system. There is no direct electrical line from the vehicle or plant power into a fuel container. The means of interrogating and powering the sensors can be completely physically and electrically isolated from the fuel and vapors by placing the sensor on the other side of an electrically non-conductive bulkhead (Fig. 2). These features prevent the interrogation system and its electrical components from becoming an ignition source.

Woodward, Stanley E.↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Leo Imagers to the Same Calibration Reference

The NASA CERES project provides climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used in tandem with the MODIS and VIIRS instruments to retrieve cloud properties required for converting CERES radiance observations into fluxes. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua-MODIS reference to retrieve consistent imager cloud properties between sensors. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun-synchronous orbit but spaced equally apart, allowing for no simultaneous nadir overpasses (SNO) to inter-calibrate the VIIRS imagers to each other. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between neither MODIS nor VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers. The study will demonstrate the use of EPIC to radiometrically scale VIIRS and MODIS imagers to the same Aqua-MODIS calibration reference. The EPIC-based NPP and N20-VIIRS scaling factors will be compared with the Aqua-MODIS based NPP and N20-VIIRS scaling factors.

C. O. Haney↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Multiple VIIRS Sensors Over Tropical Earth Views

The NASA CERES project provides Energy Balanced and Filled (EBAF) product climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 satellites. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua- MODIS reference to retrieve consistent imager cloud properties between sensors, which are used to retrieve cloud properties required for converting CERES radiance observations into fluxes. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun- synchronous orbit but spaced equally apart, which means that no simultaneous nadir overpasses (SNO) may be used to inter-calibrate the VIIRS imagers to each one another. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua-MODIS can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between either MODIS and or VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers and is especially suited for drifting orbits because EPIC imager frequently samples the Earth diurnally. The study will demonstrate the use of EPIC as a transfer radiometer to radiometrically scale the NPP and NOAA-20 VIIRS imagers. The scaling factors will be compared with the scaling factors using Aqua-MODIS as the transfer radiometer.

Conor Haney↗

Using DSCOVR EPIC as an Additional Calibration Reference to Radiometrically Scale the Geo Imagers for the NASA CERES Project

The NASA CERES project provides climate-quality observed TOA and calculated surface fluxes to the climate community. The CERES instruments are mounted on the Aqua, Terra, NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used alongside the VIIRS and MODIS based cloud properties necessary for converting CERES radiance observations into fluxes. The CERES SYN1deg product provides the regional hourly fluxes in between the Terra and Aqua/NOAA-20-CERES observations based on geostationary imager (GEO) radiances. The GEO radiances are radiometrically scaled to the MODIS or VIIRS calibration references. The GEO and MODIS inter-calibration events are limited by the Aqua-MODIS or VIIRS local equator crossing time of 1:30 PM. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth, and the Earth Polychromatic Imaging Camera (EPIC) instrument onboard DSCOVR has a constant view of the sunlit side of the Earth while taking images ranging from the UV to the NIR throughout the day. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that EPIC is radiometrically stable, which allows it to potentially be used as a transfer radiometer between imagers. This study will assess the viability of using EPIC as a consistent and stable calibration source for GEO imagers. EPIC will be inter-calibrated with Himawari-8 that has been radiometrically scaled with Aqua. The Himawari-8 based EPIC calibration gains will be verified by the EPIC calibration gains determined directly from Aqua-MODIS matches. The EPIC calibration gains based on Himawari-8 will be stratified by local time to determine any diurnal dependence of the GEO/EPIC calibration strategy.

C O Haney↗

Landsat Data Continuity Mission Calibration and Validation

The primary payload for the Landsat Data Continuity Mission (LDCM) is the Operational Land Imager (OLI), being built by Ball Aerospace and Technologies, under contract to NASA. The OLI has spectral bands similar to the Landsat-7 ETM+, minus the thermal band and with two new bands, a 443 nm band and 1375 nm cirrus detection band. On-board calibration systems include two solar diffusers (routine and pristine), a shutter and three sets of internal lamps (routine, backup and pristine). Being a pushbroom opposed to a whiskbroom design of ETM+, the system poses new challenges for characterization and calibration, chief among them being the large focal plane with 75000+ detectors. A comprehensive characterization and calibration plan is in place for the instrument and the data throughout the mission including Ball, NASA and the United States Geological Survey, which will take over operations of LDCM after on-orbit commissioning. Driving radiometric calibration requirements for OLI data include radiance calibration to 5% uncertainty (1 q); reflectance calibration to 3% uncertainty (1 q) and relative (detector-to-detector) calibration to 0.5% (J (r). Driving geometric calibration requirements for OLI include bandto- band registration of 4.5 meters (90% confidence), absolute geodetic accuracy of 65 meters (90% CE) and relative geodetic accuracy of 25 meters (90% CE). Key spectral, spatial and radiometric characterization of the OLI will occur in thermal vacuum at Ball Aerospace. During commissioning the OLI will be characterized and calibrated using celestial (sun, moon, stars) sources and terrestrial sources. The USGS EROS ground processing system will incorporate an image assessment system similar to Landsat-7 for characterization and calibration. This system will have the added benefit that characterization data will be extracted as part of the normal image data processing, so that the characterization data available will be significantly larger than for Landsat-7 ETM+.

Markham, Brian L.↗

System measures response time of photomultiplier tubes

Calibration system enables precise determination of rise time of photosensitive detectors. To perform a calibration, the time-voltage curve of the excitation voltage for a light source is compared with the time-voltage curve of the voltage output from a photosensitive detector which is responding to the light.

Lauver, M. R.↗

Argus: a new instrument for the measurement of the stratospheric dynamical tracers, N2O and CH4

We describe here a new instrument for the simultaneous, in situ measurement of the stratospheric tracer molecules, nitrous oxide (N2O) and methane (CH4). Argus is unique in its small size making it well suited for limited payload atmospheric research platforms. Argus employs second harmonic spectroscopy using tunable lead-salt diode lasers emitting in the mid-infrared. We first explain the Argus design philosophy followed by detailed descriptions of the instrument's optical, mechanical, and thermal sub-systems. Argus employs an in-flight calibration system providing real time calibrations and tightly constrained uncertainty estimates of the returned data. Data analysis is carried out using non-linear least-squares model fits to the acquired second harmonic spectra. A sampling of Argus data acquired on a recent stratospheric research campaign in the Arctic winter is presented.

Methane/analysis↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Landsat-8 Thermal Infrared Sensor (TIRS) Vicarious Radiometric Calibration

Launched in February 2013, the Landsat-8 carries on-board the Thermal Infrared Sensor (TIRS), a two-band thermal pushbroom imager, to maintain the thermal imaging capability of the Landsat program. The TIRS bands are centered at roughly 10.9 and 12 micrometers (Bands 10 and 11 respectively). They have 100 m spatial resolution and image coincidently with the Operational Land Imager (OLI), also on-board Landsat-8. The TIRS instrument has an internal calibration system consisting of a variable temperature blackbody and a special viewport with which it can see deep space; a two point calibration can be performed twice an orbit. Immediately after launch, a rigorous vicarious calibration program was started to validate the absolute calibration of the system. The two vicarious calibration teams, NASA/Jet Propulsion Laboratory (JPL) and the Rochester Institute of Technology (RIT), both make use of buoys deployed on large water bodies as the primary monitoring technique. RIT took advantage of cross-calibration opportunity soon after launch when Landsat-8 and Landsat-7 were imaging the same targets within a few minutes of each other to perform a validation of the absolute calibration. Terra MODIS is also being used for regular monitoring of the TIRS absolute calibration. The buoy initial results showed a large error in both bands, 0.29 and 0.51 W/sq m·sr·micrometers or -2.1 K and -4.4 K at 300 K in Band 10 and 11 respectively, where TIRS data was too hot. A calibration update was recommended for both bands to correct for a bias error and was implemented on 3 February 2014 in the USGS/EROS processing system, but the residual variability is still larger than desired for both bands (0.12 and 0.2 W/sq m·sr·micrometers or 0.87 and 1.67 K at 300 K). Additional work has uncovered the source of the calibration error: out-of-field stray light. While analysis continues to characterize the stray light contribution, the vicarious calibration work proceeds. The additional data have not changed the statistical assessment but indicate that the correction (particularly in band 11) is probably only valid for a subset of data. While the stray light effect is small enough in Band 10 to make the data useful across a wide array of applications, the effect in Band 11 is larger and the vicarious results suggest that Band 11 data should not be used where absolute calibration is required.

TIIRS↗