Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronous generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Black Start with Inverter-Based Resources: Hardware Testing

Black start, or grid restoration after a wide-spread power outage, is a critical service on the power system that has historically been provided by transmission-connected synchronous generators. As the power system transitions to rely on more distributed and inverter-based resources it will be critical that these resources can also provide black start services. In this work we investigated battery energy storage and solar photovoltaics technical capabilities and limitations to provide black start services through hardware testing in an experimental microgrid testbed. This hardware demonstration of inverter-based resources providing black start functions can help inform grid operators on how to include these types of resources in their black start plans.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probing-Based Inertia Estimation Method Using Hybrid Power Plants

With the displacement of synchronous generation by inverter-based resources (IBRs), power systems could face the challenge of reduced inertia since IBRs do not inherently contribute to system inertia. Therefore, there is rising interest in monitoring system inertia in real-time applications for situational awareness. In addition, there is a growing number of IBRs that provide fast frequency responses (FFR) in the form of synthetic inertia and P-f droop. It is desirable to quantify the contribution of these FFR controls as equivalent inertia. This paper proposes a probing-based inertia estimation method using a PV-battery hybrid power plant in the Kauai island power system. The method is validated under different operating conditions.

hybrid power plant↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators’ rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System

Here, this paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement-and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method-Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18-20 Hz oscillation event in Kaua‘i's power system on November 21, 2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding Regional Inertia Dynamics in CAISO from Real Grid Disturbances

The shift from synchronous generators to inverter-based resources has caused power system inertia to be unevenly distributed across power grids. As a result, certain grid regions are more vulnerable to high rate-of-change of frequency (RoCoF) during disturbances. This paper presents a measurement-based framework for estimating grid inertia in CAISO (California Independent System Operator) region using real disturbance-driven frequency data from the Frequency Monitoring Network (FNET/GridEye). By analyzing confirmed disturbances from 2013 to 2024, we identify trends in regional inertia and frequency dynamics, highlighting their relationship with renewable generation and the evolving duck curve. Regional RoCoF values were up to six times higher than interconnection-wide values, coinciding with declining inertia. Recent recovery in inertia is attributed to the increased deployment of battery energy storage systems with synthetic inertia capabilities. These findings underscore the importance of regional inertia monitoring, strategic resource planning, and adaptive operational practices to ensure grid reliability amid growing renewable integration.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Observability Analysis of a Power System Stochastic Dynamic Model Using a Derivative-Free Approach

Serving as a prerequisite to power system dynamic state estimation, the observability analysis of a power system dynamic model has recently attracted the attention of many power engineers. However, because this model is typically nonlinear and large-scale, the analysis of its observability is a challenge to the traditional derivative-based methods. Indeed, the linear-approximation-based approach may provide unreliable results while the nonlinear-technique-based approach inevitably faces extremely complicated derivations. Furthermore, because power systems are intrinsically stochastic, the traditional deterministic approaches may lead to inaccurate observability analyses. In this work, facing these challenges, we propose a novel polynomial-chaos-based derivative-free observability analysis approach that not only is free of any linear approximations, but also accounts for the stochasticity of the dynamic model while bringing a low implementation complexity. Furthermore, this approach enables us to quantify the degree of observability of a stochastic model, what conventional deterministic methods cannot do. The excellent performance of the proposed method has been demonstrated by performing extensive simulations using a synchronous generator model with IEEE-DC1A exciter and the TGOV1 turbine governor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical Models of Frequency and Voltage in Large-Scale All-Inverter Power Systems

Low-order frequency response models for power systems have a decades-long history in optimization and control problems such as unit commitment, economic dispatch, and wide-area control. With a few exceptions, these models are built upon the Newtonian mechanics of synchronous generators, assuming that the frequency dynamics across a system are approximately homogeneous, and assume the dynamics of nodal voltages for most operating conditions are negligible, and thus are not directly computed at all buses. As a result, the use of system frequency models results in the systematic underestimation of frequency minimum nadir and maximum RoCoF, and provides no insight into the reactive power-voltage dynamics. This paper proposes a low-order model of both frequency and voltage response in grid-forming inverter-dominated power systems. The proposed model accounts for spatial-temporal variations in frequency and voltage behavior across a system and as a result, demonstrates the heterogeneity of frequency response in future renewable power systems. Electromagnetic transient (EMT) simulations are used to validate the utility, accuracy, and computational efficiency of these models, setting the basis for them to serve as fast, scalable alternatives to EMT simulation, especially when dealing with very large-scale systems, for both planning and operational studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RealisticSensors

An Unreal Engine 5 plugin for generating synchronized, timestamped multi-modal sensor data for machine learning and robotics applications.

Greenwood, Scott↗

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Cybersecurity Workforce Training for SMR Integration into Distribution Grids: A Competency Framework and Containerized Hands-On Lab for the SMR/DER/Microgrid Boundary

Small modular reactors (SMRs) and microreactors are entering the U.S. distribution grid as synchronous generation on feeders designed for loads and inverter-based distributed energy resources (DERs). No existing cybersecurity training program addresses this intersection of nuclear operations, DER management, and operational technology security. As subcontractor to Iowa State University on the CyDERMS Center, Argonne analyzed the relevant standards and training landscape, translated the resulting gaps into a twelve-objective competency framework across distribution-operator and graduate-analyst role tracks, and built a containerized training lab using a ∼400-bus composite grid model behind a realistically simulated Modbus TCP SCADA stack. The analysis isolates the balance-of-plant / energy-management-system (BOP/EMS) boundary as the critical jurisdictional seam where, as of March 2026, neither NRC nor NERC CIP cleanly claims cybersecurity responsibility for distribution-connected SMRs. The framework maps each objective across NIST CSF 2.0, ISA/IEC 62443, NIST NICE Task–Knowledge–Skill statements, and NRC RG 5.71 awareness-and-training controls. The training lab implements operator-recognition assessment scenarios spanning grid-side disturbances and telemetry-layer anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation: Preprint

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators' rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

61 RADIATION PROTECTION AND DOSIMETRY↗