Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stress testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Product Reliability Trends, Derating Considerations and Failure Mechanisms with Scaled CMOS

As microelectronics is scaled into the deep sub-micron regime, space and aerospace users of advanced technology CMOS are reassessing how scaling effects impact long-term product reliability. The effects of electromigration (EM), time-dependent-dielectric-breakdown (TDDB) and hot carrier degradation (HCI and NBTI) wearout mechanisms on scaled technologies and product reliability are investigated, accelerated stress testing across several technology nodes is performed, and FA is conducted to confirm the failure mechanism(s).

CMOS integrated circuits↗

Observed changes in a-Si:H cell characteristics due to long term temperature stress

Determination of thermally induced degradation mechanisms affecting thin film amorphous silicon solar cells through the use of laboratory accelerated stress testing requires acquisition of specially constructed, individually addressable test cells and the development of highly repeatable instrumentation which is not influenced by short-term reversible optical effects. This paper illustrates these considerations by describing accelerated temperature stress procedures and test results for one type of a-Si:H cell. Observed electrical characteristic changes indicate that two types of stress induced mechanisms are operating - one of which is self limiting and can be observed at lower temperatures and one which continues to complete degradation. The self limiting mechanism can result in a dramatic improvement to cells having initially low Voc values.

Lathrop, Jay W.↗

Development and evaluation of a fault-tolerant multiprocessor (FTMP) computer. Volume 4: FTMP executive summary

The FTMP architecture is a high reliability computer concept modeled after a homogeneous multiprocessor architecture. Elements of the FTMP are operated in tight synchronism with one another and hardware fault-detection and fault-masking is provided which is transparent to the software. Operating system design and user software design is thus greatly simplified. Performance of the FTMP is also comparable to that of a simplex equivalent due to the efficiency of fault handling hardware. The FTMP project constructed an engineering module of the FTMP, programmed the machine and extensively tested the architecture through fault injection and other stress testing. This testing confirmed the soundness of the FTMP concepts.

Smith, T. B., III↗

Exercise response

The bicycle ergometer and a graded stress protocol were used to conduct exercise stress tests for the Apollo project. The graded exercise tests permitted a progressive evaluation of physiological control system response and provided a better understanding of safe stress limits; heart rate was used for determining stress levels. During each test, workload, heart rate, blood pressure, and respiratory gas exchange (oxygen consumption, carbon dioxide production, and minute volume) measurements were made. The results are presented and discussed.

J.A. Rummel↗

Interpretation and classification of microvolt T wave alternans tests

Measurement of microvolt-level T wave alternans (TWA) during routine exercise stress testing now is possible as a result of sophisticated noise reduction techniques and analytic methods that have become commercially available. Even though this technology is new, the available data suggest that microvolt TWA is a potent predictor of arrhythmia risk in diverse disease states. As this technology becomes more widely available, physicians will be called upon to interpret microvolt TWA tracings. This review seeks to establish uniform standards for the clinical interpretation of microvolt TWA tracings.

NASA Discipline Cardiopulmonary↗

Effect of Surge Current Testing on Reliability of Solid Tantalum Capacitors

Tantalum capacitors manufactured per military specifications are established reliability components and have less than 0.001% of failures per 1000 hours for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. To reduce this risk, further development of a screening and qualification system with special attention to the possible deficiencies in the existing procedures is necessary. The purpose of this work is evaluation of the effect of surge current stress testing on reliability of the parts at both steady-state and multiple surge current stress conditions. In order to reveal possible degradation and precipitate more failures, various part types were tested and stressed in the range of voltage and temperature conditions exceeding the specified limits. A model to estimate the probability of post-surge current testing-screening failures and measures to improve the effectiveness of the screening process has been suggested.

Teverovsky, Alexander↗

Dynamic EKG Study

The use of the dynamic EKG study as a part of periodic health examination is considered to be a valuable complement to other forms of stress testing with its ability to detect abnormal heart responses to stress stimuli. It is believed that statistical correlations of dynamic EKG findings with physical examination results contribute greatly to the understanding of cardiac abnormalities.

Fleck, R. L.↗

Some important considerations in the development of stress corrosion cracking test methods.

Discussion of some of the precaution needs the development of fracture-mechanics based test methods for studying stress corrosion cracking involves. Following a review of pertinent analytical fracture mechanics considerations and of basic test methods, the implications for test corrosion cracking studies of the time-to-failure determining kinetics of crack growth and life are examined. It is shown that the basic assumption of the linear-elastic fracture mechanics analyses must be clearly recognized and satisfied in experimentation and that the effects of incubation and nonsteady-state crack growth must also be properly taken into account in determining the crack growth kinetics, if valid data are to be obtained from fracture-mechanics based test methods.

Wei, R. P.↗

IC Ku-band Impatt Amplifier

High efficiency GaAs low-high-low IMPATTs were investigated. Theoretical analyses were employed to establish a design window for the material parameters to maximize microwave performance. Single mesa devices yielded typically 2 to 3 W with 16 to 23% efficiency in waveguide oscillator test circuits. IMPATTs with high reliability Pt/TiW/Pt/Au metallizations were subjected to temperature stress, non-rf bias-temperature stress, and rf bias-temperature stress. Assuming that temperature is the driving force behind the dominant failure mechanism, a mean-time-to-failure considerably greater than 500,000 hours is indicated by the stress tests. A 15 GHz, 4W, 56 dB gain microstrip amplifier was realized using GaAs FETs and IMPATTs. Power combining using a 3 db Lange coupler is employed in the power output stage having an intrinsic power-added efficiency of 15.7%. Overall dc-to-rf efficiency of the amplifier is 10.8%. The amplifier has greater than a 250 MHz, 1 db bandwidth; operates over the 0 deg to 50 C (base plate) temperature range with less than 0.5 db change in the power output; weighs 444 grams; and has a volume of 220 cu cm.

Sokolov, V.↗

Positive electrode processing for Hughes NiH2 cells

The basic procedures were developed for the manufacture of nickel cadmium batteries. An electrochemical impregnation in an aqueous ethanol solution is used in this process. Several additional controls were instituted for production of flight electrodes, including a Hughes controlled MCD, a solution reserved exclusively for the impregnation of Hughes positive electrodes a system of complete traceability for individual electrodes, an electrical characterization test to provide information on weight and capacity at the plaque level, and a stress test to provide data on capacity, weight, and physical parameters at the electrode level.

Bleser, C. A.↗

Development of an accelerated reliability test schedule for terrestrial solar cells

An accelerated test schedule using a minimum amount of tests and a minimum number of cells has been developed on the basis of stress test results obtained from more than 1500 cells of seven different cell types. The proposed tests, which include bias-temperature, bias-temperature-humidity, power cycle, thermal cycle, and thermal shock tests, use as little as 10 and up to 25 cells, depending on the test type.

Lathrop, J. W.↗

Modeling of nonlinear constitutive relations of woven ceramic composites

The linear and nonlinear tensile behavior of SiC/SiC composites is examined. This analysis is based on the observed stress-strain behavior and damage evolution from a series of loading and unloading tensile tests. Stress distribution of the composite with transverse cracks in the transverse yarns is examined, and the nonlinearity of the composite stress-strain relation due to the presence of transverse cracks is predicted by application of a maximum failure strain criterion for the transverse yarn.

Kuo, Wen-Shyong↗

Percussive Augmenter of Rotary Drills (PARoD)

A percussive augmenter is being developed and it is designed to add ultrasonic hammering to a conventional commercial rotary drill through an adapter using a piezoelectric actuator. The combination of ultrasonic hammering and rotation creates a drill that requires low power and low axial load while providing faster penetration than conventional rotary-only drills. These characteristics make percussive augmentation of rotary drills ideal for not only planetary exploration but commercial applications as well. The purpose of this internship was to produce, test, and optimize an augmenter that drives a 2 inch diameter bit. This task was part of the percussive augmenter's phase II of an ongoing contract and it involved increasing the capability of the .25 inch version of the augmenter prototype that was developed in phase I. Due to fabrication delays of the augmenter, an extensive part of the test effort was conducted using previous rotary and hammer drill prototypes. These tests focused on drilling deep over long periods of time to provide for effective stress test of the drill. Modifications were made to the drill, its components, and the testing procedure to achieve desired borehole depths. These results were used to start initial testing on the 2 inch augmenter and provide preliminary data on the augmenter's ability to significantly improve penetration rate over conventional rotary-only drills.

rotraty hammer↗

IPHE Regulations Codes and Standards Working Group - Type IV COPV Round Robin Testing

This manuscript presents the results of a multi-lateral international activity intended to understand how to execute a cycle stress test as specified in a chosen standard (GTR, SAE, ISO, EIHP...). The purpose of this work was to establish a harmonized test method protocol to ensure that the same results would be achieved regardless of the testing facility. It was found that accurate temperature measurement of the working fluid is necessary to ensure the test conditions remain within the tolerances specified. Continuous operation is possible with adequate cooling of the working fluid but this becomes more demanding if the cycle frequency increases. Recommendations for future test system design and operation are presented.

Maes, M.↗

Pyrolysis Rate and Yield Strength Reduction Incarbon Fiber and Glass Fiber Composites Underreentry Heating Conditions

The behavior of composite materials, specifically carbon fiber reinforced plastic (CFRP) and glass fiber reinforced plastic (GFRP), under reentry conditions poses a problem for space debris reentry risk modeling. Since these materials pyrolyze rather than melt and their different components demise at different rates, modeling their destruction to determine ground impact risk is complex. Modern spacecraft are using these materials in ever-greater quantities owing to their superior strength-to-weight characteristics, and this has required that the orbital debris community improve its understanding of how these materials demise on reentry. The NASA Orbital Debris Program Office undertook an extensive test campaign to better understand the rate at which several types of GFRP and CFRP materials pyrolyze under reentry heating conditions and how that pyrolysis affects the ultimate strength of the material. GFRP with a polyester resin (G10/FR-4) and CFRP with epoxy, cyanate ester, vinyl ester, and phenolic resins were tested. The test campaign was carried out at the Inductively Coupled Plasma (ICP) Torch Facility at the University of Texas at Austin. Because the ICP facility operates in a shirt-sleeve environment, test samples can be changed within seconds or minutes, allowing many samples to be tested in a short period. Two heat flux rates, 20 W/m2 and 30W/m2, and two oxygen concentration conditions, 0% and 2% of atmospheric, were applied to all five types of material. To measure both the char rate and the effect of pyrolysis on the ultimate material strength, two types of test were carried out for each material: a char rate test on a ~10 mm thick sample of material and an in-situ bending stress test of a ~2 mm thick sample of material. Measurements of the char rate showed very similar average pyrolysis front velocity in epoxy resin CFRP as in G10 at 3.6 mm/min and 3.4 mm/min, respectively. However, the total mass loss rate in theG10 was nearly double that of the CFRP at 3.8 g/min and 2.2 g/min, respectively. This result represented a slow ablation rate of carbon fibers in the CFRP at the temperatures encountered in low Earth orbit reentry and a comparatively rapid removal of the glass fibers in G10 due to melting and spallation. Pyrolysis front velocity was more significantly affected by the type of plastic than the type of fiber, with the cyanate ester CFRP samples displaying an average pyrolysis front velocity of only 1.9 mm/min. Similarly, the effect of thermal exposure on the ultimate strength of the material depended heavily on the type of plastic and very little on the type of fiber in the material. Epoxy, vinyl ester, and polyester resins all behaved very similarly, with complete structural failure at between 400 J/g and 600 J/g of specific absorbed heat. Phenolic and cyanate ester resins, on the other hand, displayed a change in structural properties that was only barely measurable with the current apparatus even after the maximum exposure time tested. These data are being incorporated into a numerical model of the ablation and demise of composite materials that will be used to more accurately calculate the ground casualty risk of future spacecraft.

Benton R. Greene↗