Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stream discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Diel mercury concentration variations in a mercury-impacted stream

Here, filtered and particulate mercury (Hg) and methylmercury (MMHg), and associated water chemistry parameters, were evaluated bi-hourly for several 30 h periods during the summer and winter seasons at several distinct locations (downstream forested, midstream urban/suburban, upstream industrial) along a creek contaminated with high levels of inorganic Hg to determine if biogeochemical Hg and MMHg cycles respond to the daily photocycle. In summer particulate Hg and MMHg concentrations doubled overnight (excluding the upstream industrial site) concurrent with increases in turbidity and total suspended sediment; no such pattern was evident in winter. Seasonal and diel changes in the activity of macrobiota affecting the suspension of contaminated sediments are likely responsible for these patterns as other potential explanatory variables (e.g., instrument drift, pH, discharge) could not account for the range and timing of our observations. Diel patterns in filtered Hg (Hg D ) were significant only at locations and times of the year when channel shading was not present and daytime concentrations increased 22–89% above nighttime minima likely caused by direct and indirect photochemical reactions. Relationships between Hg D and dissolved organic carbon (DOC) concentration or character were inconsistent between sites. Unlike Hg D , there were significant diel patterns in filtered MMHg (MMHg D ) at all sites and times of year, with summer concentrations peaking in mid to late afternoon while the timing differed in winter, with concentrations peaking after sunset. Daily variability in MMHg D concentration ranged between 25 and 75%. The results imply key controls on net methylation occur within the stream or on the stream bed and include factors such as small-scale temperature changes in the water column and photosynthetic activity of stream biofilm. With respect to stream monitoring, results from this study indicate (1) consistent timing in stream Hg and MMHg sampling is required for accurate assessment of long-term trends, (2) in situ measurements of turbidity can be used to quantify diel dynamics of both particulate Hg and MMHg concentrations, and (3) in situ fluorescing dissolved organic matter (FDOM), a potential proxy for DOC, was not capable of resolving diel dynamics of filtered Hg or MMHg.

54 ENVIRONMENTAL SCIENCES↗

Leveraging Groundwater Dynamics to Improve Predictions of Summer Low-Flow Discharges

Summer streamflow predictions are critical for managing water resources; however, warming-induced shifts from snow to rain regimes impact low-flow predictive models. Additionally, reductions in snowpack drive earlier peak flows and lower summer flows across the western United States increasing reliance on groundwater for maintaining summer streamflow. However, it remains poorly understood how groundwater contributions vary interannually. Here, we quantify recession limb groundwater (RLGW), defined as the proportional groundwater contribution to the stream during the period between peak stream flow and low flow, to predict summer low flows across three diverse western US watersheds. We ask (a) how do snow and rain dynamics influence interannual variations of RLGW contributions and summer low flows?; (b) which watershed attributes impact the effectiveness of RLGW as a predictor of summer low flows? Linear models reveal that RLGW is a strong predictor of low flows across all sites and drastically improves low-flow prediction compared to snow metrics at a rain-dominated site. Results suggest that strength of RLGW control on summer low flows may be mediated by subsurface storage. Subsurface storage can be divided into dynamic (i.e., variability saturated) and deep (i.e., permanently saturated) components, and we hypothesize that interannual variability in dynamic storage contribution to streamflow drives RLGW variability. In systems with a higher proportion of dynamic storage, RLGW is a better predictor of summer low flow because the stream is more responsive to dynamic storage contributions compared to deep-storage-dominated systems. Overall, including RLGW improved low-flow prediction across diverse watersheds.

54 ENVIRONMENTAL SCIENCES↗

Salts in Hot Water: Developing a Scientific Basis for Supercritical Desalination and Strategic Metal Recovery

Given the steady growth in world population and the ever-increasing fresh water demand, the only sustainable water supply option is desalination. Conceptually, desalination is very simple - just separate dissolved salts from water. While desalination research programs have existed since the 1960s and have resulted in a multitude of approaches, realizing affordable desalination has proven to be a challenge. Our goal is to meet this challenge using low cost heat sources to drive a liquid-discharge-free desalination process that can be co-mingled with the extraction of economically valuable co-products. High temperatures and pressures will be used to manipulate water’s properties, such as the dielectric constant, and hence its ability to solvate ions. Selective precipitation/recovery of valuable metal co-products creates new revenue streams (i.e., cost offsets). We will develop the scientific understanding necessary to control salt precipitation from supercritical seawater, inland brines, and water commonly co-produced with oil and gas. Atomistic simulations will be used to understand at a molecular level the changes in hydrogen bonding and ion solvation that occur as we increase the temperature and/or pressure and change the density and ion concentration. Our simulation results will also aid in the interpretation of experimental data and guide the development of applied thermodynamic models for engineering design calculations.

58 GEOSCIENCES↗

Co-Extrusion (CoEx) for Cost Reduction of Advanced High-Energy-and-Power Battery Electrode Manufacturing

Co-Extrusion (CoEx) is a deposition technology developed at PARC that uses engineered fluidic channels to cause multiple streams of dissimilar fluids to impart shape to one another. Here, we describe the use of CoEx to produce structured cathode electrode films to improve electrochemical performance of thick electrode films. CoEx enables us to create structured electrode films that have periodic regions of enhanced ionic conductivity, enabling higher utilization of thicker cathode films at high discharge rates. While increasing electrode thickness is a known method for increasing energy density of battery electrodes, this increase in energy density typically also results in reduced power density. This project, a collaboration between the Palo Alto Research Center, Oak Ridge National Laboratories, and Ford Motor Company, seeks to first validate the benefits of CoEx at the coin cell level, before performing the necessary R&D effort to scale production up to large (10+ Ah) pouch cells that will show increased energy density without a reduction in power density. We used conventional battery materials (commercially available NMC, PVDF, carbon black, and graphite) to produce structured electrodes via CoEx and compared them to thick and thin conventionally produced (unstructured) battery electrodes. CoEx electrodes show improved high rate performance compared to unstructured electrodes, resulting in higher energy density pouch cells compared to the baseline electrode of 7 and 11% in volumetric and gravimetric energy density, respectively. These electrodes also showed substantially improved electrochemical performance at high discharge rates compared to thick conventional electrodes.

25 ENERGY STORAGE↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Kinetic simulation study of magnetized collisionless shock formation on a terawatt laser system

Perpendicular, magnetized, collisionless shocks in hydrogen and neon plasmas are studied with 2-D particle-in-cell simulations for parameters accessible to experiments on OMEGA EP. The simulations are performed with realistic ion-electron mass ratios by which the relative importance of different micro-instabilities can be accurately captured. The dispersion relation of the modified two-stream instability (MTSI), the main dissipation mechanism for these shocks, is used to find suitable parameters for upcoming experiments. Simulations show that magnetized collisionless shocks can be readily formed within a few tenths of an ion gyro-period in both hydrogen and neon gases, with a background magnetic field of 50 T, achievable using the magneto-inertial fusion electrical discharge system (MIFEDS). Here, a portion of the ions are reflected to the upstream region and accelerated in both shock normal and tangential directions, indicating the formation of a supercritical shock. Shock front reformation is seen in longer time 1-D simulations. The results show that the formation time and width of these shocks are determined by MTSI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long-Term Changes in Concentration and Yield of Riverine Dissolved Silicon From the Poles to the Tropics

Riverine exports of silicon (Si) influence global carbon cycling through the growth of marine diatoms, which account for ~25% of global primary production. Climate change will likely alter river Si exports in biome-specific ways due to interacting shifts in chemical weathering rates, hydrologic connectivity, and metabolic processes in aquatic and terrestrial systems. Nonetheless, factors driving long-term changes in Si exports remain unexplored at local, regional, and global scales. We evaluated how concentrations and yields of dissolved Si (DSi) changed over the last several decades of rapid climate warming using long-term data sets from 60 rivers and streams spanning the globe (e.g., Antarctic, tropical, temperate, boreal, alpine, Arctic systems). We show that widespread changes in river DSi concentration and yield have occurred, with the most substantial shifts occurring in alpine and polar regions. The magnitude and direction of trends varied within and among biomes, were most strongly associated with differences in land cover, and were often independent of changes in river discharge. These findings indicate that there are likely diverse mechanisms driving change in river Si biogeochemistry that span the land-water interface, which may include glacial melt, changes in terrestrial vegetation, and river productivity. Finally, trends were often stronger in months outside of the growing season, particularly in temperate and boreal systems, demonstrating a potentially important role of shifting seasonality for the flux of Si from rivers. Our results have implications for the timing and magnitude of silica processing in rivers and its delivery to global oceans.

54 ENVIRONMENTAL SCIENCES↗

Y-12 National Security Complex Biological Monitoring and Abatement Program—2024 Calendar Year Report

This report provides the results of the CY 2024 sampling of East Fork Poplar Creek (EFPC) as part of the Y-12 National Security Complex (Y-12) Biological Monitoring and Abatement Program (BMAP). The results are presented in the context of historical trends. The Y-12 BMAP was developed in 1985 to demonstrate that the effluent limits established for Y-12 protected the classified uses of the receiving stream, particularly the growth and propagation of aquatic life (Loar et al. 1989). Over the years, the BMAP has become an important and valuable long-term measure of stream conditions resulting from actions and activities at the Y-12 Complex. The BMAP currently consists of three tasks: (1) bioaccumulation monitoring, (2) benthic macroinvertebrate community monitoring, and (3) fish community monitoring. The benthic macroinvertebrate community monitoring task includes studies to evaluate the receiving stream’s biological integrity annually in comparison with Tennessee Water Quality Criteria following Tennessee Department of Environment and Conservation (TDEC) protocols. In addition to presenting the EFPC biological monitoring results, this report includes results from Comprehensive Environmental Response, Compensation, and Liability Act–funded BMAP programs in Bear Creek and McCoy Branch (presented in Appendixes A and B, respectively), as required in the Y-12 National Pollutant Discharge Elimination System (NPDES) permit. Additional biological testing at the Y-12 Complex includes toxicity testing of select storm drains as required in the NPDES permit. Although toxicity testing is not formally part of the BMAP, toxicity testing results from 2024 are provided in Appendix C.

54 ENVIRONMENTAL SCIENCES↗

Overcoming the Intrinsic Limitations of Fast Charging Lithium‐Ion Batteries Using Integrated Acoustic Streaming

A lithium‐ion battery's maximum charge rate and energy density are intrinsically limited by the ion diffusion rate in the electrolyte. Most research focuses on materials science solutions to this problem, with gradual improvement over the years. A mechanical solution is proposed to integrate an MHz‐order frequency surface acoustic wave (SAW) device into an existing 1.8 Ah multilayered Li‐ion pouch cell to enhance the ion diffusion rate and the overall battery performance. Both the charging rate and cycling lifetime are improved from SAW. At a 6C (10 min) charge and C/3 discharge rate, typical of electric vehicle applications, integrating SAW into the Li‐ion cell doubles the energy density and maintains at least 72% of the battery's initial capacity after 2000 cycles. Moreover, using SAW quantifiably reduces battery degradation in these conditions as determined by optical imaging, scanning electron microscopy, X‐ray diffraction, and neutron diffraction. The use of SAW appears to offer a method to avoid undesirable Li metal plating on the graphite anode during charging, and leads to a much longer battery lifetime and good charge capacity, all despite rapid charging.

Huang, An↗

Developing ML/AI Methods for High-Throughput Characterization of Multiple-Sensor Streams of Tokamak Dynamics for High-Speed Control (Final Report)

This project evaluated and developed new mathematical and algorithmic techniques capable of handling (in real-time) the growing amounts of data generated by modern fusion research. While existing numerical linear algebra (NLA) methods provide the backbone to classical data analysis and algorithms, these methods fundamentally do not port to distributed architectures nor do they allow low-latency data reduction for control. Motivated by the needs for modern fusion reactors, this project explored and implemented new numerical methods to characterize plasma dynamics, respond in real-time to discharge evolution, and to process massive-scale data accurately and rapidly more fully. This project links expertise in multiple-sensor diagnostics of tokamak plasma dynamics from Columbia University’s Plasma Physics Laboratory with expertise in massive-scale data reduction and extreme data control algorithms at Columbia University’s Data Science Institute. This interdisciplinary project (i) applied machine learning methods, (ii) implemented a properly-trained neural-network for very fast processing of high-speed plasma videography, and (ii) developed the applied mathematical methods, based on randomized-NLA (rNLA) routines, for data analysis, reduction, and real-time control. The Columbia University High Beta Tokamak-Extended Pulse (HBT-EP) facility provided data to test new algorithms and partnership with Columbia University's Data Sciences Institute evaluated the broader use of new algorithms for many challenging control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Leaching Processes for the Recovery of Rare Earth Elements from Acid Mine Drainage Precipitates

Acid mine drainage (AMD) has been a challenge for mine operators to address and has had significant environmental impacts when there is a failure to address it. Fortunately, there is a regulation in the US that requires the treatment of AMD before water can be discharged into the environment. AMD is generated when sulfide minerals are exposed to water and air from mining. The acidic water then leaches metals from the surrounding rock, creating the potential for environmental contamination of this acidic water containing dissolved metals. AMD can contain high concentrations of metals like iron, aluminum, and manganese and also have been shown to contain trace concentrations of critical minerals, including rare earth elements (REEs). This environmental waste stream is now being researched as a potential source for REEs. There is a patented process for processing and extracting REEs from AMD which produces rare earth oxide preconcentrate (REOP) from AMD treatment precipitates and a final stage mixed rare earth oxide (MREO) product. This body of research examines a selective leaching process for each of these products and determines the activation energy associated with the leaching processes. Acid leaching with HCl was examined to selectively leach REEs from REOP while contaminant metals remained in the solid residue. The maximum leaching recovery of the REEs from the REOP was approximately 90% and an activation energy of 6.4 kJ/mol at pH 3.0. Ammonium chloride leaching was examined to selectively remove contaminant metals from a MREO product. The ammonium chloride process successfully leached major contaminant metals in excess of 85% recovery and had a maximum activation energy of 40.0 kJ/mol.

01 COAL, LIGNITE, AND PEAT↗

Vitrification of High-Cr Glass in Research-Scale Melter

This test report describes the experimental results from a small-scale test using the research-scale melter (RSM) at Pacific Northwest National Laboratory to demonstrate processing of a high-Cr simulated feed stream, designated HLW-HCr-16. The RSM is a small, joule-heated melter capable of processing melter feed continuously. The melter is equipped with Inconel ® 693 electrodes, Monofrax ® K-3 refractory, and an Inconel 690 pour spout. An electric kiln surrounds the melter body and minimizes heat loss from the melter body during operation. The RSM is equipped with an offgas treatment system that employs quenching, wet scrubbing, and high-efficiency mist elimination. The glass-discharge section is heated to facilitate pouring of the glass. The melter is fitted with a melt cavity that is ~25 cm (10 in.) in diameter with a nominal glass depth of 8.9 cm (3.5 in.). The melter was operated with a target glass temperature of 1150°C and target plenum temperature between 550°C and 700°C for this test. The air bubbling rate was 4.2 L/min. Overall, during the continuous operation of the melter for ~ 103 hours, ~ 141 kg of glass was produced. At the conclusion of the test, the melter and exhaust lines were visually inspected for particulate deposition and corrosion. Entrained material had adhered to the underside of the melter lid and to the exhaust piping. Enrichments in elements such as Cl, F, B, K, Li, P, Na, and S were measured in these deposits through inductively coupled plasma–optical emission spectroscopy and X-ray fluorescence analysis. When the melter electrodes and air bubbler tube were removed from the glass in the RSM, the electrodes appeared discolored, but no significant loss of metal was observed. The processing of a high-Cr simulant, HLW-HCr-16, in the RSM produced glass at an average rate of 1.36 kg/h, equaling a melter-surface-area normalized glass generation rate of 654 kg/day/m 2 . The resulting glass met the toxicity characteristic leaching procedure requirement. Test results of crystallinity, electrical conductivity, and viscosity showed good processing properties of this high-Cr high-level waste glass. RSM offgas was also sampled and analyzed at periodic intervals during steady-state operating conditions. The total decontamination factor averaged by four sampling periods was 134. The concentrations of CO and NO x in emissions were 237 to 422 and 69 to 94 parts per million by volume, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2D Dam-Break Analysis of L Lake and PAR Pond Dams Using HEC-RAS

In 1991 a dam-break study was conducted for the high hazard dams located at L Lake and PAR Pond on the Savannah River Site. Two scenarios were considered, over topping from a Probable Maximum Flood (PMF), and a fair weather dam-break for either or both dams. Unfortunately, no inundation map was developed from the study. The purpose of this project was to redo the original dam-break study with improved data and methodology to generate Inundation maps to assist with emergency response and evacuation plans. The Hydrologic Engineering Center's River Analysis System (HEC-RAS) is a free to download river analysis modeling program developed by the US Army Corps of Engineers capable of 1D and 2D hydraulic calculations. Version 5.0.7 (released March 2019) was used for this project. Digital elevation models for the area were retrieved from the US Geological Survey database and converted to a .hdf file within the program. Then the 2D flood area was identified from the contours. Both L Lake and PAR Pond were inputted as 1D storage areas because DEM data does not contain elevation values under water bodies. An elevation vs volume curve was available for both storage areas. Initial elevations were set for both scenarios. Both dams are earthen dams. The Steel Creek dam at L Lake has 6 ft diameter conduit with an upper and lower sluice gate. PAR pond dam consist of a weir and sluice gate connected to an 8 x 8 ft channel. Both outlets were modeled with a pool elevation vs discharge curve. The steel creek dam sluice gates were assumed to be fully open in all cases. As in the previous study, the dams were set to breach when they were overtopped by 1.5 ft during PMF conditions (Figure 1). A fair weather breach was set to be due to a piping failure (Figure 1). In the dual dam break during fair weather conditions the PAR pond dam fails 3 hours after Steel Creek to achieve maximum flooding in the down stream reaches. Simulation was run 3 days for each case and with a 1 minute computational interval. Maximum flooding occurs under PMF conditions with the failure of both dams. PAR pond dam fails first 16 hours and 32 minutes after the start of the simulation with the Steel creek dam failing 6 minutes later. In all cases, the bridges and roads spanning Steel Creek and Lower Three Runs will be inundated and potentially washed away. The Burtons Ferry Highway south of the storage areas will be partially flooded during PMF failure, dual fair weather failure, and PAR pond failure under fair weather conditions.

54 ENVIRONMENTAL SCIENCES↗

Tritiated Water Disposition Strategies

Tritium, a radioactive isotope of hydrogen, is typically confined within one or more confinement barriers. Tritium readily reacts with oxygen to form tritiated water or can exchange with protium or deuterium atoms in water to create tritiated water which is around 10,000 times more toxic than elemental tritium. Primary tritium confinement systems can create small volumes of highly tritiated water. Secondary confinement systems, like inert gloveboxes, will produce larger volumes of lower concentration tritiated water. Much larger volumes of tritiated water of very low tritium content are produced by tritium permeation/diffusion. Tritium from inside primary and secondary confinement barriers will diffuse from these systems into cooling water systems. Closed loop, recirculating cooling water systems will slowly accumulate tritium and create concentrations which exceed drinking water (or permitted discharge) concentrations. The cooling water systems designed as series of interconnected cooling loops that can slowly transfer tritium from one cooling loop to another cooling loop through heat exchangers. These large volumes of tritiated water may be above federal discharge limits and also lack convenient disposition pathways. This document will discuss tritiated water management strategies from the perspective of large volume, low tritium concentrations that exceed drinking water or permitted discharge limits. Applicable US regulatory requirements for a Molybdenum-99 (Mo-99) production facility concerning tritiated water are also cited. Tritiated water disposition options, based on typical waste minimization strategies will guide dispositions options. A Case Study example is presented to illustrate the pros and cons of several disposition options. The report does not recommend any particular disposition pathway but discusses strategies to be explored by a producer to guide selection of processes which best fits the needs of a particular waste stream.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Rapid Charging Made Practical in Graphite-Based Lithium Batteries: Surface-Acoustic Wave Turbulent Electrolyte Mixing to Overcome Diffusion Limited Charging Rates

One of the key limits in rapidly recharging a lithium-ion battery is the depletion of lithium ions within the electrolyte adjacent the anode during charging and long diffusion time to overcome this depletion. It also causes dendrite formation, inefficient use of the lithium, and battery degradation over many charge-discharge cycles. Because the liquid electrolyte remains quiescent and unmixed, this depletion layer's depth rapidly grows to match the anode-cathode separation distance at even modest charge rates. The solution proposed by PI Prof. James Friend and Co-PI Prof. Ping Liu, both from the University of California, San Diego, is to mix the electrolyte and minimize the Li ion concentration gradient during charging. Even in the presence of the separator, the charging rate could then be significantly increased. They propose to accomplish this using surface acoustic wave (SAW)-driven acoustic streaming, a technique employing 10-mW fingernail-sized solid-state devices from the telecommunications industry to drive turbulent mixing to submicron length scales in a manner completely compatible with the typical 20700 and 18650 cells used in electric vehicles.

25 ENERGY STORAGE↗

Co-treating flue gas desulfurized effluent and produced water enables novel waste management and recovery of critical minerals

Herein this study reports a novel approach of resource recovery from co-managing two geographically co-located and chemically complementary wastewaters using a pilot-scale treatment process. Designed to treat flue gas desulfurized (FGD) effluent from combustion powerplants and produced water (PW) from energy industries, the process consists of soda-ash softening, nanofiltration (NF), and reverse osmosis (RO). Recovered products are barite, calcite, and low-salinity water. Using field-collected waters, the results show that softening at pH 8.5 produces calcite (yield: 30 kg/m 3 treated water), a chemical used as SO ₂(g) scrubbers. NF treatment under an applied pressure of 3.5 MPa yields a permeate stream laden with monovalent ions (water recovery 60%) and a concentrate stream with a sulfate concentration 1.8 times of the feedwater concentration. Mixing the NF concentrate and PW at a volumetric ratio of 1.0 precipitates a high-density barite material (4.1 g/cm 3 , yield: ~7.5 kg/m 3 mixture) – a critical mineral commonly used as a weighting agent in drilling. The RO treatment recovers >64% water as the permeate, which can be readily used as cooling make-up water at the powerplants. The RO concentrate stream can be further processed in a thermal evaporative system for additional water recovery and brine production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗