Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strain gage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Fundamental Improvement of a Convergence Test for Iterative Strain-Gage Balance Load Predictions

A fundamental improvement of a convergence test for wind tunnel strain-gage balance load iterations was developed. The improvement became necessary because incorrect test results were obtained whenever the original test was applied to multi-component balances with large load capacity differences. The original test was first published in NASA TN D-6860. It uses an upper bound of the Lipschitz constant to assess convergence characteristics of balance load predictions whenever the Iterative Method is applied. The Lipschitz constant is a function of the partial derivatives of each balance load component with respect to all other load components. Unfortunately, the original definition of the convergence test overlooked the fact that the Lipschitz constant is a dimensionless quantity and that the partial derivative of one load component with respect to another load component is not always dimensionless. Therefore, an improvement of the original test was successfully developed that uses load capacities to make all inputs for the calculation of the Lipschitz constant dimensionless before use. Results from the calibration data analysis of a six-component force balance and a five-component semi-span balance are used to illustrate the application of the improved load iteration convergence test.

Strain-Gage Balance↗

Compensated High Temperature Strain Gage

A device for measuring strain in substrates at high temperatures in which the thermally induced apparent strain is nulled is described. Two gages are used, one active gage and one compensating gage. Both gages are placed on the substrate to be gaged; the active gage is attached such that it responds to mechanical and thermally induced apparent strain while the compensating gage is attached such that it does not respond to mechanical strain and and measures only thermally induced apparent strain. A thermal blanket is placed over the two gages to maintain the gages at the same temperature. The two gages are wired as adjacent arms of a wheatstone bridge which nulls the thermally induced apparent strain giving a true reading of the mechanical strain in the substrate.

Source record↗

Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

The safety-of-flight parameters for the Adaptive Compliant Trailing Edge (ACTE) flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces were monitored; each contained four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty-one applied test load cases were developed using the predicted in-flight loads. Pre-test predictions of strain gage responses were produced using finite element method models of the interface fittings. Predicted and measured test strains are presented. A load testing rig and three hydraulic jacks were used to apply combinations of shear, bending, and axial loads to the interface fittings. Hardware deflections under load were measured using photogrammetry and transducers. Due to deflections in the interface fitting hardware and test rig, finite element model techniques were used to calculate the reaction loads throughout the applied load range, taking into account the elastically-deformed geometry. The primary load equations were selected based on multiple calibration metrics. An independent set of validation cases was used to validate each derived equation. The 2-sigma residual errors for the shear loads were less than eight percent of the full-scale calibration load; the 2-sigma residual errors for the bending moment loads were less than three percent of the full-scale calibration load. The derived load equations for shear, bending, and axial loads are presented, with the calculated errors for both the calibration cases and the independent validation load cases.

Miller, Eric J.↗

A Universal Threshold for the Assessment of Load and Output Residuals of Strain-Gage Balance Data

A new universal residual threshold for the detection of load and gage output residual outliers of wind tunnel strain{gage balance data was developed. The threshold works with both the Iterative and Non{Iterative Methods that are used in the aerospace testing community to analyze and process balance data. It also supports all known load and gage output formats that are traditionally used to describe balance data. The threshold's definition is based on an empirical electrical constant. First, the constant is used to construct a threshold for the assessment of gage output residuals. Then, the related threshold for the assessment of load residuals is obtained by multiplying the empirical electrical constant with the sum of the absolute values of all first partial derivatives of a given load component. The empirical constant equals 2.5 microV/V for the assessment of balance calibration or check load data residuals. A value of 0.5 microV/V is recommended for the evaluation of repeat point residuals because, by design, the calculation of these residuals removes errors that are associated with the regression analysis of the data itself. Data from a calibration of a six-component force balance is used to illustrate the application of the new threshold definitions to real{world balance calibration data.

wind tunnel balance↗

High temperature strain gage technology for hypersonic aircraft development applications

An experimental evaluation of Pd 13 percent Cr and of BCL-3 alloy wire strain gages was conducted on IN100 and Cu 0.15 percent Zr alloy substrates. Testing included apparent strain, drift, gage factor, and creep. Maximum test temperature was 1144 K (1600 F). The PdCr gages incorporated Pt temperature compensation elements. The PdCr gages were found to have good resistance stability below 866 K (1100 F). The BCL 3 gages were found to have good resistance stability above 800 K (981 F), but high drift around 700 K (800 F).

Anderson, W. L.↗

Comparison of Electrical Output Format Options for the Analysis of Strain-Gage Balance Calibration Data

Fundamental characteristics of three gage output formats are discussed that may be used to both interpret and analyze wind tunnel strain-gage balance data. The first output format uses raw outputs, i.e., absolute voltage measurements, for the analysis. This choice requires an intercept term in the regression model of the outputs if the Iterative Method is chosen for the load prediction. Raw outputs can be used for the analysis of all known output characteristics as long as the Iterative Method is applied. However, raw outputs cannot be used to analyze data of a balance with bi-directional outputs if the Non-Iterative Method is chosen for the analysis. The second output format, i.e., difference type 1, uses the difference between raw outputs and the natural zeros of the balance gages for the analysis. In this case, the use of the intercept term becomes optional. Analysis results for difference type 1 will exactly match analysis results obtained by using raw outputs as long as identical math models are used for the regression analysis. In addition, difference type 1 may be used to analyze data of a balance with bi directional outputs if an analyst prefers to process data using the Non-Iterative Method. The third output format, i.e., difference type 2, uses the difference between raw outputs and the outputs of the zero load point of a load series for the data analysis. The application of this format is only recommended if the maximum magnitude of all tare loads of a given balance calibration data set is less than two percent of capacity. Data from the calibration of a force balance is used to illustrate the application of the three gage output formats.

Wind Tunnel Strain-Gage Balance↗

Evaluation of submarine strain-gage systems for monitoring coastal sediment migration

Single and multiple strain-gage systems were respectively evaluated as in situ point and areal sensors for monitoring sand-height variations in coastal environments. Static loading tests indicate that gage response pressure is linear for sand heights up to 24 inches. Response pressures are a function of both sand height and aggregate density, with density being influenced by both sediment texture and degree of compaction. Poorer sediment sorting and greater compaction result in higher response pressures. Field tests in a beach foreshore environment indicate that the gage systems are effective qualitative instruments for monitoring long-period migration trends of beach sediments; whereas, short-period responses are not sufficiently reliable. The durability and compactness of the gage systems must be substantially increased for effective field operations. It is recommended that the systems' qualitative potentials be further developed, whereas their development as quantitative instruments be terminated. Further development should emphasize the construction of remote recording systems designed for semipermanent installation.

Shideler, G. L.↗

Overcoats for the Improved Performance of PdCr High Temperature Thin Film Strain Gages

Overcoat protection schemes for thin film devices have typically focused on inhibiting the growth of native oxides formed on the sensor surface, rather than on improving the passivating nature of these native oxides. Here, thin sputtered Cr overcoats and heat treatments in varying oxygen partial pressures enhanced the passivating nature of native Cr203 films formed on PdCr thin film strain gages. Results of strain tests using sensors protected using this approach are presented and the implications are discussed. PdCr gages with sputtered Cr overcoats withstood 12,000 dynamic strain cycles of 1100 micro-epsilon during 100 hours of testing at a temperature of 1000 C in air. Gage factors of 1.3 with drift rates as low as 0.1 Omega/hr were achieved for devices having a nominal resistance of approximately 100 Omega's. TCR's ranging from +550 ppm/C to +798 ppm/C were realized depending on the overcoat and thermal history. Possible mechanisms for an anomaly in the electrical characteristics of these films at 800 C and improvements in stability due to the use of overcoats are presented.

Gregory, Otto J.↗

A Universal Tare Load Prediction Algorithm for Strain-Gage Balance Calibration Data Analysis

An algorithm is discussed that may be used to estimate tare loads of wind tunnel strain-gage balance calibration data. The algorithm was originally developed by R. Galway of IAR/NRC Canada and has been described in the literature for the iterative analysis technique. Basic ideas of Galway's algorithm, however, are universally applicable and work for both the iterative and the non-iterative analysis technique. A recent modification of Galway's algorithm is presented that improves the convergence behavior of the tare load prediction process if it is used in combination with the non-iterative analysis technique. The modified algorithm allows an analyst to use an alternate method for the calculation of intermediate non-linear tare load estimates whenever Galway's original approach does not lead to a convergence of the tare load iterations. It is also shown in detail how Galway's algorithm may be applied to the non-iterative analysis technique. Hand load data from the calibration of a six-component force balance is used to illustrate the application of the original and modified tare load prediction method. During the analysis of the data both the iterative and the non-iterative analysis technique were applied. Overall, predicted tare loads for combinations of the two tare load prediction methods and the two balance data analysis techniques showed excellent agreement as long as the tare load iterations converged. The modified algorithm, however, appears to have an advantage over the original algorithm when absolute voltage measurements of gage outputs are processed using the non-iterative analysis technique. In these situations only the modified algorithm converged because it uses an exact solution of the intermediate non-linear tare load estimate for the tare load iteration.

balance calibration analysis↗

Errors associated with the use of strain gages on composite materials

The present effort to characterize the influence of strain gage misalignments in the case of their bonding to fiber-reinforced composite materials considers the effects of differences in thermal expansion, transverse sensitivity, and noncoincidence of principal stress on principal strain directions. The largest error is noted to be obtained when the minor Poisson ratio of a composite is measured. The correction procedures remain important for strain measurements on laminates.

Hiel, C. C.↗

Strain measurement within a single-lap joint using embedded strain gages

An experimental method used to measure the in-plane normal-axial strains produced within a single-lap joint is described in which a resistance-foil strain gage is embedded within the joint prior to curing of the adhesive. Nominal dimensions of the titanium Ti-6-4 adherends were 0.13 x 2.5 x 12.7 cm and an overlap of 2.5 cm was used. The joint was bonded with FM-300 structural adhesive. The average ultimate shear strength of the gaged specimens and control specimens was 16.1 MPa and 14.1 MPa. A significant advantage of the proposed method is that strains internal to the joint are measured, rather than strains at an external edge. The presence of the gage was found to be not detrimental to bond performance.

Tuttle, M. E.↗

Strain gage measurement errors in the transient heating of structural components

Significant strain-gage errors may exist in measurements acquired in transient thermal environments if conventional correction methods are applied. Conventional correction theory was modified and a new experimental method was developed to correct indicated strain data for errors created in radiant heating environments ranging from 0.6 C/sec (1 F/sec) to over 56 C/sec (100 F/sec). In some cases the new and conventional methods differed by as much as 30 percent. Experimental and analytical results were compared to demonstrate the new technique. For heating conditions greater than 6 C/sec (10 F/sec), the indicated strain data corrected with the developed technique compared much better to analysis than the same data corrected with the conventional technique.

Richards, W. Lance↗

Use of photostress and strain gages to analyze behavior of weldments

Tensile and pure bending tests were conducted on specimens having welded joints made from 2219-T87 aluminum alloy and 2319 filler. Data were collected using photoelastic coatings and strain gages. Stress-strain relationships and contraction ratios were determined at several points in a grid covering the weld material and heat affected zone. Material behavior was nonlinear and nonuniform at all points in the grid and contraction ratios did not conform to those predicted by Chakrabarty's plasticity theory. Yielding in joints made using four new welding procedures was examined. None of the new procedures produced more uniform yielding in the joint.

Gambrell, S. C., Jr.↗

Electrical properties of materials for high temperature strain gage applications

A study was done on the electrical resistance of materials that are potentially useful as resistance strain gages at high temperatures under static strain conditions. Initially a number of binary alloys were investigated. Later, third elements were added to these alloys, all of which were prepared by arc melting. Several transition metals were selected for experimentation, most prepared as thin films. Difficulties with electrical contacts thwarted efforts to extend measurements to the targeted 1000 C, but results obtained did suggest ways of improving the electrical resistance characteristics of certain materials.

Brittain, John O.↗