At least 163 records · Page 9

How To Maintain Effective IAEA Safeguards While Reducing Facility Impact

For almost twenty years, inspectors from the International Atomic Energy Agency have been visiting the K-Area Material Storage facility at the Savannah River Site where excess plutonium has been placed under IAEA safeguards as part of the United States Volunatary Offer Agreement. During that time, the mission of K-Area Complex has expanded from storage of nuclear matieral to glovebox operations in support of the National Nuclear Security Administration’s Plutonium Disposition program. With this change in mission, it is becoming increasingly challenging to manage facility staff radiation exposure and operating activities during the IAEA’s annual Physcial Inventory Verifications (PIV). This study has identified both near-term and long-term recommendations for IAEA monitoring protocols that would allow the IAEA to maintain effective safeguards of the material while decreasing the impact to the facility. A statisitical analysis has shown that reducing the number of containers measured during an annual PIV from 12 to 4 still ensures a high level of confidence in the confidence while reducing the inspector time in the facility amd with a corresponding significant reduction in personnel radiation exposure. A modified installation pattern of Remotely Monitored Sealing Arrays (RMSAs) is also proposed utilizing only the outer rows of arrays of stored material containers in the Stack Area (SA). The modified RMSA placement will provide equivalent protection, while significantly reducing personnel radiological exposure, manpower requirements and associated costs. With advances in technology, there are additional potential options in containment/surveillance and continuity of knowledge that would allow the agency to be outside of the facility during PIV measurements and have confidence in the accuracy and authencitity of the results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Studies of cryogenic propellant storage and handling for the lunar landing and launch facility (complex 39L)

A brief description of Complex 39L as it is currently conceived is presented. A brief discussion of lunar thermal history is then presented. From this follows a discussion of the current lunar thermal environment which will impact the design of cryogenic storage and handling facilities on the moon. Some previous studies are discussed. A conceptual design of liquid oxygen and hydrogen storage facilities is presented. The essential feature of this facility is that cryogens are to be stored in a number of small tanks which can serve as lander propellant tanks rather than as one large storage vessel. These tanks will be placed under a Fuel Inventory Tent (FIT) for shadow shielding. Methods of dealing with propellant boil-off are discussed. A base case cascade refrigeration system for requirements are such that it seems very feasible to construct a prototype boil-off recovery system in a laboratory environment.

Linsley, Jerald N.↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Final Seismic Shake Table Test Plan

The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test on the dry storage systems of spent nuclear fuel (SNF) to close the gap related to seismic loads on fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. Full-scale testing is needed because a dry storage system is a complex and highly nonlinear system making it hard to predict (model) the responses to seismic excitations. The non-linearity arises from the multiple spatial gaps in the system – between fuel rods and the basket, between the basket and dry storage canister, between the dry storage canister and the storage cask (overpack), and ventilation gaps. The non-linearities pose significant limitations on the value of tests with scaled systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding electronic structure tunability by metal dopants for promoting MgB 2 hydrogenation

Hydrogen is a promising energy carrier, but its onboard application is limited by the need for compact, low-pressure storage solutions. Solid-state complex metal hydride systems, such as MgB 2 /Mg(BH 4 ) 2 , offer high storage capacities but suffer from sluggish kinetics and poor reversibility. One avenue for improving reactivity is to introduce metal dopants to alter electronic and atomic properties, but the role of these chemical additives remains poorly understood, particularly for the hydrogenation reaction. In this work, we used density functional theory calculations on model MgB 2 systems to rationalize the potential role of metal dopants in destabilizing B–B bonding within the MgB 2 lattice. We carried out detailed electronic structure analyses for 28 different metal dopant adatoms to identify properties that contribute to a dopant’s efficacy. Based on the simulation results, we propose that an intermediate ionic and covalent character of the bonds between adatoms and B atoms is desirable for facilitating charge redistribution, disrupting the B–B bond network, and promoting H 2 dissociation and H atom chemisorption on MgB 2 .

08 HYDROGEN↗

Complexing Agent-Assisted Membraneless Zinc–Iodine Aqueous Batteries

A membrane is required for conventional zinc–iodine aqueous batteries, since soluble polyiodides cross over to the anode side and react with zinc metal spontaneously. Making the battery membraneless increases ion transport and reduces its cost and overall footprint. In this paper, a membraneless Zn–I 2 aqueous battery is demonstrated, employing a complexing agent, 1-butyl-1-methylpyrrolidinium iodide (MBPI), to promote the formation of I 5 – -containing, phase-separated polyiodides upon charging, to minimize self-discharge and suppress Zn dendrite growth. With an additional 0.3 M MBPI in 4 M ZnI 2 electrolyte, the membraneless battery achieved 65 cycles with >85% Coulombic efficiency, whereas the MBPI-free control failed immediately. Additionally, a volumetric capacity of 14.3 Ah L –1 was achieved, surpassing those of most membraneless batteries reported to date regardless of redox chemistry, and underscores the potential of complexing agents in simplifying the architecture of conventional Zn–I 2 flow batteries.

25 ENERGY STORAGE↗

Superior Capacitive Energy-Storage Performance in Pb-Free Relaxors with a Simple Chemical Composition

Chemical design of lead-free relaxors with simultaneously high energy density (W rec ) and high efficiency (η) for capacitive energy-storage has been a big challenge for advanced electronic systems. The current situation indicates that realizing such superior energy-storage properties requires highly complex chemical components. Herein, we demonstrate that, via local structure design, an ultrahigh W rec of 10.1 J/cm 3 , concurrent with a high η of 90%, as well as excellent thermal and frequency stabilities can be achieved in a relaxor with a very simple chemical composition. By introducing 6s 2 lone pair stereochemical active Bi into the classical BaTiO 3 ferroelectric to generate a mismatch between A- and B-site polar displacements, a relaxor state with strong local polar fluctuations can be formed. Through advanced atomic-resolution displacement mapping and 3D reconstructing the nanoscale structure from neutron/X-ray total scattering, it is revealed that the localized Bi enhances the polar length largely at several perovskite unit cells and disrupts the long-range coherent Ti polar displacements, resulting in a slush-like structure with extremely small size polar clusters and strong local polar fluctuations. This favorable relaxor state exhibits substantially enhanced polarization, and minimized hysteresis at a high breakdown strength. This work offers a feasible avenue to chemically design new relaxors with a simple composition for high-performance capacitive energy-storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Cation-Tethered Flowable Polymeric Interface for Enabling Stable Deposition of Metallic Lithium

A fundamental challenge, shared across many energy storage devices, is the complexity of electrochemistry at the electrode–electrolyte interfaces that impacts the Coulombic efficiency, operational rate capability, and lifetime. Specifically, in energy-dense lithium metal batteries, the charging/discharging process results in structural heterogeneities of the metal anode, leading to battery failure by short-circuit and capacity fade. In this work, we take advantage of organic cations with lower reduction potential than lithium to build an electrically responsive polymer interface that not only adapts to morphological perturbations during electrodeposition and stripping but also modulates the lithium ion migration pathways to eliminate surface roughening. As a result, we find that this concept can enable prolonging the long-term cycling of a high-voltage lithium metal battery by at least twofold compared to bare lithium metal.

25 ENERGY STORAGE↗

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an open-source electronic hardware platform, and it consists of a microcontroller and two sensors. Finally, we read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an opensource electronic hardware platform, and it consists of a microcontroller and two sensors. We read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it. This project and code demo are available on the GitHub site at this URL: https://github.com/santorofer/MDSplusAndCustomeDevices

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Operating System/360

RTOS has a cost savings advantage for real-time applications, such as those with random inputs requiring a flexible data routing facility, display systems simplified by a device independent interface language, and complex applications needing added storage protection and data queuing.

Hoffman, R. L.↗

Study of genetic direct search algorithms for function optimization

The results are presented of a study to determine the performance of genetic direct search algorithms in solving function optimization problems arising in the optimal and adaptive control areas. The findings indicate that: (1) genetic algorithms can outperform standard algorithms in multimodal and/or noisy optimization situations, but suffer from lack of gradient exploitation facilities when gradient information can be utilized to guide the search. (2) For large populations, or low dimensional function spaces, mutation is a sufficient operator. However for small populations or high dimensional functions, crossover applied in about equal frequency with mutation is an optimum combination. (3) Complexity, in terms of storage space and running time, is significantly increased when population size is increased or the inversion operator, or the second level adaptation routine is added to the basic structure.

Zeigler, B. P.↗

Data System Implications Derived from User Application Requirements for Satellite Data

An investigation of the data system needs as driven by users of space acquired Earth observation data is documented. Two major categories of users, operational and research, are identified. Limiting data acquisition alleviates some of the delays in processing thus improving timeliness of the delivered product. Trade offs occur between timeliness and data distribution costs, and between data storage and reprocessing. The complexity of the data system requirements to apply space data to users' needs is such that no single analysis suffices to design and implement the optimum system. A series of iterations is required with analyses of the salient problems in a general way, followed by a limited implementation of benefit to some users with a continual upgrade in system capacity, functions, and applications served. The resulting most important requirement for the data system is flexibility to accommodate changing requirements as the system is implemented.

Neiers, J.↗

Free radical propulsion concept

The concept of a free radical propulsion system, utilizing the recombination energy of dissociated low molecular weight gases to produce thrust, is analyzed. The system, operating at a theoretical impulse with hydrogen, as high as 2200 seconds at high thrust to power ratio, is hypothesized to bridge the gap between chemical and electrostatic propulsion capabilities. A comparative methodology is outlined by which characteristics of chemical and electric propulsion for orbit raising mission can be investigated. It is noted that free radicals proposed in rockets previously met with difficulty and complexity in terms of storage requirements; the present study proposes to eliminate the storage requirements by using electric energy to achieve a continuous-flow product of free radicals which are recombined to produce a high velocity propellant. Microwave energy used to dissociate a continuously flowing gas is transferred to the propellant via three-body-recombination for conversion to propellant kinetic energy. Microwave plasma discharge was found in excess of 90 percent over a broad range of pressure in preliminary experiments, and microwave heating compared to electrothermal heating showed much higher temperatures in gasdynamic equations.

Hawkins, C. E.↗

Managing geometric information with a data base management system

The strategies for managing computer based geometry are described. The computer model of geometry is the basis for communication, manipulation, and analysis of shape information. The research on integrated programs for aerospace-vehicle design (IPAD) focuses on the use of data base management system (DBMS) technology to manage engineering/manufacturing data. The objectives of IPAD is to develop a computer based engineering complex which automates the storage, management, protection, and retrieval of engineering data. In particular, this facility must manage geometry information as well as associated data. The approach taken on the IPAD project to achieve this objective is discussed. Geometry management in current systems and the approach taken in the early IPAD prototypes are examined.

Dube, R. P.↗

Multispectral observations of the Jovian aurora

The upper atmospheres of the Earth and the outer planets form a screen on which precipitating charged particles, like the electron beam in a television, trace fleeting, but revealing patterns of visible, ultraviolet, infrared, and x ray emissions that offer valuable clues to processes occurring within the planetary magnetospheres. At Earth, years of in situ measurements, as well as ground based observations, have yielded a picture (still fuzzy) where the interaction of the solar wind with the magnetosphere of the Earth provides a complex path for the storage and release of energy during magnetic substorms; the ultimate manifestation of terrestrial auroral processes. More recent global imaging of substorm events from high above the Earth (greater than 3.5 R(sub e)) by Dynamics Explorer have made a unique contribution towards understanding the global and temporal evolution of such auroral events by providing a morphological perspective and by providing the crucial observational link that allows the separation of spatial and temporal variations inherent in the interpretation of in situ data. A similar role was played by the Hubble Space Telescope (HST) during the recent encounter of Ulysses with Jupiter in helping to define a new paradigm in Jovian auroral physics. The old paradigm portrayed Jupiter's magnetosphere as totally dominated by internal processes (i.e. Io related tori, heavy ions, etc.) where energetic heavy ion precipitation in the inner magnetosphere was solely responsible for the observed auroral phenomena. Ulysses and HST portray a more Earth-like paradigm where electron acceleration in the outer magnetosphere near the boundary with the solar wind plays a distinct role in the formation of auroral hot spots, yet energetic heavy ions also enter into the picture (similar to the role of the energetic ions from the terrestrial ring current during magnetic substorms). These heavy ions as a result of excitation during their transit through the atmosphere produce the x ray emissions observed in Roentgensatellit (ROSAT) x ray energy spectra.

Source record↗