Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrum monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

High-Energy X-Ray Detection of G359.89-0.08 (SGR A-E): Magnetic Flux Tube Emission Powered by Cosmic Rays?

We report the first detection of high-energy X-ray (E (is) greater than 10 keV) emission from the Galactic center non-thermal filament G359.89−0.08 (Sgr A−E) using data acquired with the Nuclear Spectroscopic Telescope Array (NuSTAR). The bright filament was detected up to approximately 50 keV during a NuSTAR Galactic center monitoring campaign. The featureless power-law spectrum with a photon index gamma approximately equals 2.3 confirms a non-thermal emission mechanism. The observed flux in the 3-79 keV band is F(sub X) = (2.0 +/- 0.1) × 10(exp -12)erg cm(-2) s(-1) , corresponding to an unabsorbed X-ray luminosity L(sub X) = (2.6+/-0.8)×10(exp 34) erg s(-1) assuming a distance of 8.0 kpc. Based on theoretical predictions and observations, we conclude that Sgr A−E is unlikely to be a pulsar wind nebula (PWN) or supernova remnant-molecular cloud (SNR-MC) interaction, as previously hypothesized. Instead, the emission could be due to a magnetic flux tube which traps TeV electrons. We propose two possible TeV electron sources: old PWNe (up to (is) approximately 100 kyr) with low surface brightness and radii up to (is) approximately 30 pc or MCs illuminated by cosmic rays (CRs) from CR accelerators such as SNRs or Sgr A*.

X-rays: individual↗

Photoacoustic microcantilevers

A system generates a photoacoustic spectrum in an open or closed environment with reduced noise. A source focuses a beam on a target substance disposed on a base. The base supports a cantilever that measures acoustic waves generated as light is absorbed by the target substance. By focusing a chopped/pulsed light beam on the target substance, a range of optical absorbance may be measured as the wavelength of light changes. An identifying spectrum of the target may detected by monitoring the vibration intensity variation of the cantilever as a function of illuminating wavelength or color.

47 OTHER INSTRUMENTATION↗

Spectral Multi-peak Analysis Methodology for Eliminating Effects of NaI Temperature Drift

This paper presents a methodology of spectral multi-peak analysis for eliminating temperature drift effects of NaI scintillation gamma-ray detectors. Properties and cost of NaI make it an excellent choice for low energy (< 1-MeV) spectroscopic studies. However, the light output of NaI scintillators has high temperature dependence, and the common practice of selecting a region of interest (ROI) for the peak of study in the measured spectrum requires that NaI temperature drift be monitored and corrected, typically by gain control of the measurement electronics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An alternative calibration method for counting P-32 reactor monitors

Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because it can be performed regardless of the characterization of the exposure environment. Count rates produced by sulfur pellets are correlated to the measured quantity of separated {sup 32}P. A posteriori spectral and cross section determination can be used to correlate the quantity of phosphorus back to a neutron fluence in a reference field. This paper outlines a method for the setup, calibration, and use of the detector systems, {sup 32}P sample preparation, and analysis of the beta spectrum. An uncertainty analysis and comparison to ASTM E265 is also included. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Frequency spectrum analysis code for nuclear noise based on improved wavelet algorithm - 337

The core of the narrow flow channel generally faced the problem of local bubble boiling with the temperature rise of the nuclear fuel element, it is necessary and meaningful to answer and deal with the problem on the technical level. Reactor noise analysis begins with the study of the physical characteristics of the core, after nearly 30 years of research and development it has become a powerful tool in the auxiliary monitoring of the power reactor operating. By using this noise frequency spectrum analysis technology, the reactor dynamic parameter such as prompt neutron decay constant can be measured. Also, through such system, the frequency characteristics of reactor can be real-time monitored, which is helpful for safety operation and fault diagnosis. Spectrum analysis technology in the Fourier analysis era is now barely available, the reason is that the local spectral characteristics of this technology are not obvious, but this defect can be greatly improved by wavelet analysis technique, however, the traditional wavelet analysis will introduce the problem of spectral confusion. To solve the problem, based on the improved wavelet algorithm, frequency spectrum analysis code for nuclear noise is developed,from the perspective of fine spectral analysis, the local boiling accident of the coolant can be prejudged and avoid. Based on the analysis and test of experimental data,The results show that the calculation ability of the code is in accordance with the expected, it can be applied in the operation of research reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multispectral Scanner for Monitoring Plants

A multispectral scanner has been adapted to capture spectral images of living plants under various types of illumination for purposes of monitoring the health of, or monitoring the transfer of genes into, the plants. In a health-monitoring application, the plants are illuminated with full-spectrum visible and near infrared light and the scanner is used to acquire a reflected-light spectral signature known to be indicative of the health of the plants. In a gene-transfer- monitoring application, the plants are illuminated with blue or ultraviolet light and the scanner is used to capture fluorescence images from a green fluorescent protein (GFP) that is expressed as result of the gene transfer. The choice of wavelength of the illumination and the wavelength of the fluorescence to be monitored depends on the specific GFP.

Gat, Nahum↗

Facile Template-Free Fabrication of the hollow sea cucumber-like TbF{sub 3} and luminescent properties

Graphical abstract: Hollow sea cucumber-like TbF{sub 3} has been prepared via a facile hydrothermal route. The possible growth mechanism and the luminescent properties of the as-prepared sample have been discussed. - Highlights: • TbF3 particles were prepared by a facile hydrothermal route. • TbF3 product show strong green emission. • This method may be more widely applicable in the design of other rare-earth compounds. - Abstract: Hollow sea cucumber-like TbF{sub 3} was successfully fabricated by a self-assembled hydrothermal method. The crystal structure, morphology and photoluminescence properties of the as-prepared TbF{sub 3} crystals were investigated. The results revealed that the as-prepared TbF{sub 3} sample has orthorhombic structure and composed of monodispersed 3D hollow sea cucumber-like particles. The possible formation mechanism for sea cucumber-like TbF{sub 3} is presented in detail. Additionally, the as-prepared sample possesses property of down-conversion photoluminescence. The excitation spectrum of TbF{sub 3} sample was obtained by monitoring the emission of Tb{sup 3+} at 545 nm was composed of the characteristics f–f transition lines within the Tb{sup 3+} 4f{sup 8} configuration. Under the UV light irradiation, the emission spectrum exhibited four obvious lines centered at 491, 545, 588, and 620 nm, which was corresponding to the {sup 5}D{sub 4} → {sup 7}F{sub J} (J = 6, 5, 4, 3) transitions of the Tb{sup 3+} ions in the TbF{sub 3} nanoparticles.

36 MATERIALS SCIENCE↗

Fatigue cracking of aluminum under spectrum loading at various humidities

The effect of moisture on Stage I fatigue in aluminum was studied under constant amplitude loading and under a severe log-normal spectrum loading. Crack initiation and early crack growth was monitored using accurate specimen compliance measurements statistically generated using computer-aided data acquisition and analysis. Fatigue strength in aluminum was found to be greatly reduced by humidity under both constant amplitude and log-normal spectrum loading. Use of Miner's theory of cumulative damage to predict the outcome of the spectrum tests, given the results of the constant amplitude tests, was investigated. A systematic pattern of deviation from Miner's theory was found, which was also a function of the humidity level.

Chappell, D. P.↗

Spectrum analysis of acoustic emissions from boron-aluminum composites

Acoustic emissions were monitored from unidirectional tension specimens of boron-aluminum composites. It is shown that a sudden increase in count rate presages final failure. This sudden increase, however, occurs at a variable point relative to final failure load. Spectrum analysis in the range from 1 to 100 kHz was performed on the emissions with the result that no immediately obvious recognition pattern exists to distinguish between types of failure mechanisms. It is suggested that either acoustic emissions cannot be used to distinguish different failure modes in boron-aluminum composites in the frequency range studied or the specimens used had only one failure mode operating with sufficient energy release to be detected. The spectrum analysis did show, however, that the acoustic emissions had frequency components much higher than the frequencies for the fundamental modes of natural vibration of the specimen.

Henneke, E. G., II↗

Calibration of the NEAR XRS Solar Monitor

The NEAR-Shoemaker X-ray spectrometer measured elemental abundance ratios for six elements (Mg, Al, Si, S, Ca, Fe) on the surface of 433 Eros by remote-sensing x-ray fluorescence spectroscopy (1,2). The fluorescent x-rays are excited by x-rays from the solar corona. Therefore, accurate knowledge of the incident solar spectrum was critically important to interpreting the fluorescence spectra received by the NEAR detectors in terms of elemental ratios on the asteroid's surface. NEAR, therefore, carried two additional X-ray spectrometers dedicated to monitoring the solar spectrum between 1 and 10 keV. One of these, a Si PIN photodiode, failed prior to orbit insertion. The second consisted of a gas-filled proportional counter similar to the asteroid-pointing detectors, but covered by a graded filter (3) intended to attenuate the incoming solar flux and increase the dynamic range of the detector. Unfortunately, the response of this filter as a function of solar incidence angle was not adequately determined in the laboratory prior to launch. The response function had to be calculated from the assumed properties of the graded filter.

Lim, L. F.↗

Elemental Composition of 433 Eros: New Calibration of the NEAR-Shoemaker XRS Data

We present relative elemental abundances for six elements (Mg, Al, Si, S, Ca, Fe) in the surface layer of 433 Eros, derived from a new analysis of the solar induced fluorescence measured by the NEARShoemaker X ray Spectrometer (XRS).XRS derived elemental abundances have been presented before. However, calibration of XRS data depends critically on knowledge of the incident solar spectrum, which varies greatly on time scales of seconds to minutes. Unfortunately, the gas solar monitor carried by NEAR was inadequately calibrated prior to launch. The previously published XRS results were based partly on broadband measurements by the Earthorbiting GOES8 (Geostationary Operational Environmental Satellites) Xray detectors and partly on a preliminary solar monitor calibration carried out by the present authors. The new solar monitor calibration is based on a more recent set of physical models of the solar spectrum at various temperatures, an improved fitting procedure, analysis of a large number of flight spectra, and comparison with concurrent data from the GOES Xray detectors. In addition, the new analysis includes data from three solar flares not considered in earlier papers.

Lim, L. F.↗

MOA-2010-BLG-523: 'FAILED PLANET' = RS CVn STAR

The Galactic bulge source MOA-2010-BLG-523S exhibited short-term deviations from a standard microlensing light curve near the peak of an A {sub max} {approx} 265 high-magnification microlensing event. The deviations originally seemed consistent with expectations for a planetary companion to the principal lens. We combine long-term photometric monitoring with a previously published high-resolution spectrum taken near peak to demonstrate that this is an RS CVn variable, so that planetary microlensing is not required to explain the light-curve deviations. This is the first spectroscopically confirmed RS CVn star discovered in the Galactic bulge.

79 ASTRONOMY AND ASTROPHYSICS↗

High Resolution Temporal and Spectral Monitoring of Eta Carinae's X-Ray Emission the June Eclipse

The supermassive and luminous star Eta Carinae undergoes strong X-ray variations every 5.5 years when its 2-10 keV X-ray emission brightens rapidly with wild fluctuations before dropping by a factor of 100 to a minimum lasting 3 months. The most recent X-ray "eclipse" began in June 2003 and during this time Eta Carinae was intensely observed throughout the electromagnetic spectrum. Here we report the first results of frequent monitoring of the 2-10 keV band X-ray emission by the Rossi X-ray Timing Explorer along wit high resolution X-ray spectra obtained with the transmission gratings on the Chandra X-ray Observatory. We compare these observations to those results obtained during the previous X-ray eclipse in 1998, and interpret the variations in the X-ray brightness, in the amount of absorption, in the X-ray emission measure and in the K-shell emission lines in terms of a colliding wind binary model.

Corcoran, M. F.↗

The Changing Changing-Look AGN 1ES 1927+654

We report on X-ray follow-up observations of the March 2018 nuclear transient event AT2018zf (ASASSN-18el) from an ongoing campaign that includes XMM-Newton, NuSTAR, Swift, and high cadence (daily-to-weekly) NICER observations. The event was associated with the Seyfert galaxy 1ES 1927+654, a "True Type-2" that, nevertheless, showed an X-ray spectrum typical of an unobscured Type 1 AGN. Optical monitoring revealed the emergence of broad Balmer emission lines following the outburst, suggesting a transition from a Type 2 to a Type 1 AGN on timescales consistent with the light-travel time between the central black hole and the broad line region. The optical outburst was followed by a dramatic shift in the X-ray spectrum as the hard X-ray luminosity of the corona plunged by >2 orders of magnitude and the spectrum became dominated by a 10^6 K thermal component. The subsequent X-ray evolution of 1ES 1927+654 includes an additional two-order of magnitude decline in overall luminosity, followed by an extended period of quiescence, and re-brightening to levels that make it the brightest AGN currently in the X-ray sky. Throughout its evolution, the source has displayed X-ray flux variability of factors of several on timescales less than hour, and of ~100 on timescales less than a day. The X-ray spectrum varies along a consistent luminosity-dependent track, wherein increases in flux are accompanied by a spectral hardening. We seem to be witnessing the onset of an instability in the pre-existing AGN disc and corona, followed by a still-continuing re-emergence of the corona. If the initial transient is identified as the tidal disruption of a star, it is possible that this was the instigator of this unique behavior.

Loewenstein, M.↗

Development of a Safety Hazards Risk Assessment Tool for Uncrewed Aircraft System Traffic Management during Preflight Planning

Tremendous growth in the uncrewed and remotely piloted vehicle market is expected in low-altitude, uncontrolled airspace, resulting in potential decreases in safety without systems that support monitoring, assessing, and mitigating risk. At NASA, the System-Wide Safety (SWS) project has been developing a suite of data-driven tools to predict hazards so that the potential risks that these hazards pose can be mitigated. Services to predict various hazards have been developed, including battery capacity, proximity to static obstacles, population risks, global positioning system signal strength, radio frequency spectrum interference risk, and vertiport congestion. These services can monitor hazards along a flight path and if any risks posed by these hazards exceed a threshold, the uncrewed aircraft system (UAS) fleet manager can be alerted to mitigate the risk by modifying the flight path, changing the scheduled departure or arrival times, and/or diverting the vehicle to an alternate vertiport. These services were originally developed to monitor and assess risks during flight, but they have been adapted to assess hazard risks prior to departure so that a fleet manager can evaluate the potential risks for a fleet of UAS along their planned flight paths. These services have been integrated into a prototype tool called the Supplemental Data Service Provider-Consolidated Dashboard (SDSP-CD), developed at NASA Ames Research Center. The tool consists of a dashboard which provides a comprehensive overview for a number of risks and a map display that shows the details of the hazards along each flight’s path. Based on the findings from three previous studies, the SDSP-CD has been updated with new design elements and functions. In this paper, we describe lessons learned from the previous studies, changes made to the interface, and the feedback received during a follow-up usability study. Overall, participants reported that there is a substantial benefit of having a fleet manager use a consolidated dashboard to assess hazards for the vehicles in their fleet and to provide situational awareness to potential risks so that they can be mitigated prior to flight. Once the SDSP-CD matures, it will need to be integrated into flight and mission planning tools. Some initial thoughts on how this integration should be accomplished are shared in this paper. Finally, the functional differences between preflight vs. in-flight risk assessment and the differences in fleet manager vs. UAS pilot roles that may require different information and user interactions are discussed.

preflight↗

Engineering a Full Gamut of Structural Colors in All-Dielectric Mesoporous Network Metamaterials

Structural colors are a result of the scattering of certain frequencies of the incident light on micro- or nanoscale features in a material. This is a quite different phenomenon from that of colors produced by absorption of different frequencies of the visible spectrum by pigments or dyes, which is the most common way of coloring used in our daily life. However, structural colors are more robust and can be engineered to span most of the visible spectrum without changing the base material, only its internal structure. They are abundant in nature, with examples as colorful as beetle shells and butterfly wings, but there are few ways of preparing them for large-scale commercial applications for real-world uses. In this work, we present a technique to create a full gamut of structural colors based on a low-cost, robust, and scalable fabrication of periodic network structures in porous alumina as well as the strategy to theoretically predict and engineer different colors on demand. We experimentally demonstrate mesoporous network metamaterial structures with engineered colors spanning the whole optical spectrum and discuss their applications in sensing, environmental monitoring, biomimetic tissues engineering, etc.

36 MATERIALS SCIENCE↗

Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and {sup 60}Co γ-rays

Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference {sup 60}Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a {sup 60}Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to {sup 60}Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2–40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. Conclusions: The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and {sup 60}Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.

60 APPLIED LIFE SCIENCES↗

The VHE γ-Ray View of the FSRQ PKS 1510-089

The flat spectrum radio quasar PKS 1510-089 is a monitored target in many wavelength bands due to its high variability. It was detected as a very-high-energy (VHE) γ-ray emitter with H.E.S.S. in 2009, and has since been a regular target of VHE observations by the imaging Cherenkov observatories H.E.S.S. and MAGIC. Here, we summarize the current state of results focusing on the monitoring effort with H.E.S.S. and the discovery of a particularly strong VHE flare in 2016 with H.E.S.S. and MAGIC. While the source has now been established as a weak, but regular emitter at VHE, no correlation with other energy bands has been established. This is underlined by the 2016 VHE flare, where the detected optical and high-energy γ-ray counterparts evolve differently than the VHE flux.

79 ASTRONOMY AND ASTROPHYSICS↗