Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral responsivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design Rules for Tailoring Antireflection Properties of Hierarchical Optical Structures

Hierarchical structures consisting of small sub-wavelength features stacked atop larger structures have been demonstrated as an effective means of reducing the reflectance of surfaces. However, optical devices require different antireflective properties depending on the application, and general unifying guidelines on hierarchical structures' design to attain a desired antireflection spectral response are still lacking. The type of reflectivity (diffuse, specular, or total/hemispherical) and its angular- and spectral-dependence are all dictated by the structural parameters. Through computational and experimental studies, guidelines have been devised to modify these various aspects of reflectivity across the solar spectrum by proper selection of the features of hierarchical structures. In this wavelength regime, micrometer-scale substructures dictate the long-wavelength spectral response and effectively reduce specular reflectance, whereas nanometer-scale substructures dictate primarily the visible wavelength spectral response and reduce diffuse reflectance. Coupling structures having these two length scales into hierarchical arrays impressively reduces surfaces' hemispherical reflectance across a broad spectrum of wavelengths and angles. Furthermore, such hierarchical structures in silicon are demonstrated having an average total reflectance across the solar spectrum of 1.1% (average weighted reflectance of 1% in the 280–2500 nm range of the AM 1.5 G spectrum) and specular reflectance <1% even at angles of incidence as high as 67°.

14 SOLAR ENERGY↗

An analysis of the effect of biological and physical parameters of a wetlands grass biome on the spectral modeling of phytomass and primary productivity

Aircraft simulated thematic mapper data and field data were acquired in the fall and spring to analyze the relationship of spectral response and biomass for the marsh grass Spartina patens. Regression results indicate no simple relationship exists for TMS spectral response and biomass with a high R sq. However, results show a consistent relationship between spectral response and the percent live vegetation (by weight) and percent interstitial standing surface water (by area) as independent variables. It is suggested that the reflected energy of a pixel represents a mixture of surface constituents. It is recommended that alternative remote sensors be employed to account for the pixel constituents of live and dead vegetation, litter, and standing water.

Butera, M. K.↗

Excimer laser processing of backside-illuminated CCDS

An excimer laser is used to activate previously implanted dopants on the backside of a backside-illuminated CCD. The controlled ion implantation of the backside and subsequent thin layer heating and recrystallization by the short wavelength pulsed excimer laser simultaneously activates the dopant and anneals out implant damage. This improves the dark current response, repairs defective pixels and improves spectral response. This process heats a very thin layer of the material to high temperatures on a nanosecond time scale while the bulk of the delicate CCD substrate remains at low temperature. Excimer laser processing backside-illuminated CCD's enables salvage and utilization of otherwise nonfunctional components by bringing their dark current response to within an acceptable range. This process is particularly useful for solid state imaging detectors used in commercial, scientific and government applications requiring a wide spectral response and low light level detection.

Russell, S. D.↗

Physical Origins of the Transient Absorption Spectra and Dynamics in Thin-Film Semiconductors: The Case of BiVO 4

Transient absorption (TA) spectroscopy is uniquely suited for understanding kinetic processes initiated by light over vast ranges of time. In combination with white light probes, the recorded differential absorption spectra can contain spectroscopic signatures characteristic of specific charge carrier population densities. However, disentangling the often-complex and convoluted spectra is made challenging without robust analysis methods relating the underlying physical mechanisms to the spectral components. In this work, we address the origin of the transient spectra of a model system of emerging solar energy harvesting materials using a monoclinic BiVO 4 thin film. Using ground-state optical properties of the semiconductor, we find the main derivative-like spectral response to be related to shifting and broadening of oscillators, rather than specific carrier-related transitions. However, by using the Drude optical model of free carriers, we also identify the transient response related to free-hole density. Importantly, sample heating from the optical pumping, which begins at ~10 ps and plateaus by ~200 ps, dominates the overall spectral response at longer times. On the basis of a physical model of the spectral response, a kinetic model is developed that describes the pump power dependence of the free-hole density, as well as the temporal evolution of the spectral changes associated with shifting and broadening of oscillators. First-principles density functional theory calculations are used to rationalize experimental measurements. Here, this comprehensive approach to analyzing and modeling the TA spectra offers a generalizable basis for understanding the complex pump-probe data, reveals thermal heating artifacts that are frequently erroneously assigned to long-lived photocarriers, and offers a path to eliminating ambiguity in analysis of photocarrier dynamics in solid-state systems.

36 MATERIALS SCIENCE↗

System-Independent X-Ray Characterization

We have developed a method for image reconstruction and analysis of dual-energy X-ray scans that has been demonstrated to yield a physically intuitive characterization of materials (by electron density and effective atomic number) in a system-independent way. Our methodology stands in contrast to common practice of reconstructing images to yield linear attenuation coefficients, which depend strongly on system spectral response. At the core of our method, a technique called dual-energy decomposition is used to generate spectral energy-independent characterizations of the attenuation properties of a material. Inputs to this decomposition include system spectral response estimates and dual-energy X-ray projection data. X-ray cross-section tables are used to convert decomposition results to physical feature estimates (electron density, effective atomic number). Our method currently works best for materials with atomic numbers below 22 (titanium). In prior work for DHS, we demonstrated in a controlled, no-clutter environment that the decomposition technique could be applied to scans of a well-characterized materials on multiple systems with different X-ray spectral responses. In cases where LAC values showed a standard deviation of as much as 20% of mean value, application of our method yielded results with standard deviations as low as 1–3% of mean value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Development of Sb-based Phototransistors in the 0.9- to 2.2-microns Wavelength Range for Applications to Laser Remote Sensing

We have investigated commercially available photodiodes and also recent developed Sb-based phototransistors in order to compare their performances for applications to laser remote sensing. A custom-designed phototransistor in the 0.9- to 2.2-microns wavelength range has been developed at AstroPower and characterized at NASA Langley's Detector Characterization Laboratory. The phototransistor's performance greatly exceeds the previously reported results at this wavelength range in the literature. The detector testing included spectral response, dark current and noise measurements. Spectral response measurements were carried out to determine the responsivity at 2-microns wavelength at different bias voltages with fixed temperature; and different temperatures with fixed bias voltage. Current versus voltage characteristics were also recorded at different temperatures. Results show high responsivity of 2650 A/W corresponding to an internal gain of three orders of magnitude, and high detectivity (D*) of 3.9x10(exp 11) cm.Hz(exp 1/2)/W that is equivalent to a noise-equivalent-power of 4.6x10(exp -14) W/Hz(exp 1/2) (-4.0 V @ -20 C) with a light collecting area diameter of 200-microns. It appears that this recently developed 2-micron phototransistor's performances such as responsivity, detectivity, and gain are improved significantly as compared to the previously published APD and SAM APD using similar materials. These detectors are considered as phototransistors based-on their structures and performance characteristics and may have great potential for high sensitivity differential absorption lidar (DIAL) measurements of carbon dioxide and water vapor at 2.05-microns and 1.9-microns, respectively.

Abedin, M. Nurul↗

Interaction of Sound from Supersonic Jets with Nearby Structures

A model of sound generated in an ideally expanded supersonic (Mach 2) jet is solved numerically. Two configurations are considered: (1) a free jet and (2) an installed jet with a nearby array of flexible aircraft type panels. In the later case the panels vibrate in response to loading by sound from the jet and the full coupling between the panels and the jet is considered, accounting for panel response and radiation. The long time behavior of the jet is considered. Results for near field and far field disturbance, the far field pressure and the vibration of and radiation from the panels are presented. Panel response crucially depends on the location of the panels. Panels located upstream of the Mach cone are subject to a low level, nearly continuous spectral excitation and consequently exhibit a low level, relatively continuous spectral response. In contrast, panels located within the Mach cone are subject to a significant loading due to the intense Mach wave radiation of sound and exhibit a large, relatively peaked spectral response centered around the peak frequency of sound radiation. The panels radiate in a similar fashion to the sound in the jet, in particular exhibiting a relatively peaked spectral response at approximately the Mach angle from the bounding wall.

Fenno, C. C., Jr.↗

Infrared Responsivity of a Pyroelectric Detector with a Single-Wall Carbon Nanotube Coating

The performance of a 10 mm diameter pyroelectric detector coated with a single-wall carbon nanotube (SWCNT) was evaluated in the 0.8 to 20 {micro}m wavelength range. The relative spectral responsivity of this detector exhibits significant fluctuations over the wavelength range examined. This is consistent with independent absorbance measurements, which show that SWCNTs exhibit selective absorption bands in the visible and near-infrared. The performance of the detector in terms of noise equivalent power and detectivity in wavelength regions of high coating absorptivity was comparable with gold-black-coated pyroelectric detectors based on 50 {micro}m thick LiTaO{sub 3} crystals. The response of this detector was shown to be nonlinear for DC equivalent photocurrents >10{sup -9} A, and its spatial uniformity of response was comparable with other pyroelectric detectors utilizing gold-black coatings. The nonuniform spectral responsivity exhibited by the SWCNT-coated detector is expected to severely restrict the use of SWCNTs as black coatings for thermal detectors. However, the deposition of SWCNT coatings on a pyroelectric crystal followed by the study of the prominence of the spectral features in the relative spectral responsivity of the resultant pyroelectric detectors is shown to provide an effective method for quantifying the impurity content in SWCNT samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tellurium doping effect in avalanche-mode amorphous selenium photoconductive film

Amorphous selenium (a-Se) high-gain avalanche rushing amorphous photoconductor (HARP) film has been used for highly sensitive imaging devices. To improve the spectral response of a-Se HARP photoconductive film at a long wavelength, the tellurium (Te) doping effect in an 8-μm-thick a-Se HARP film was investigated. The thickness of the Te-doped a-Se layer in the 8-μm-thick a-Se HARP films was varied from 60 to 120 nm. The signal current increases significantly due to the avalanche multiplication when the target voltage is increased over the threshold voltage. In the 8-μm-thick a-Se HARP film with a Te-doped layer, the spectral response at a long wavelength was improved in comparison with the a-Se HARP film without a Te-doped layer. In addition, the increase of the lag in the 8-μm-thick a-Se HARP target with a Te-doped layer of 120 nm is caused by the photoconductive lag due to the electrons trapped in the Te-doped layer. Based on the current-voltage characteristics, spectral response, and lag characteristics of the 8-μm-thick a-Se HARP targets, the Te-doped layer thickness of 90 nm is suitable for the 8-μm-thick a-Se HARP film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computed lateral power spectral density response of conventional and STOL airplanes to random atmospheric turbulence

A method of computing the power spectral densities of the lateral response of airplanes to random atmospheric turbulence was adapted to an electronic digital computer. By use of this program, the power spectral densities of the lateral roll, yaw, and sideslip angular displacement of several conventional and STOL airplanes were computed. The results show that for the conventional airplanes, the roll response is more prominent than that for yaw or sideslip response. For the STOL airplanes, on the other hand, the yaw and sideslip responses were larger than the roll response. The response frequency of the STOL airplanes generally is higher than that for the conventional airplanes. This combination of greater sensitivity of the STOL airplanes in yaw and sideslip and the frequency at which they occur could be a factor causing the poor riding qualities of this class of airplanes.

Lichtenstein, J. H.↗

An improved spectral calibration requirement for AVIRIS

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectra from 400 to 2500 nm through 224 contiguous spectral channels. These spectra are used to identify and determine the abundances of constituents of the earth's surface and atmosphere through the analysis of spectral molecular absorptions and scattering properties of materials. Spectral calibration of the AVIRIS is required to pursue these determinations, which are based on these fundamental spectral characteristics. The spectral calibration of AVIRIS consists of a description of the spectral response function for each of the 224 spectral channels. The spectral response function of AVIRIS channels was measured in the laboratory and shown to be Gaussian in shape. A subset of nine AVIRIS spectral channels is shown with channel centers at 10 nm intervals and channel shapes of Gaussian form with 10 nm full width and half maximum (FWHM). For AVIRIS the spectral calibration is described by the spectral center and FWHM of a Gaussian function for each channel. Uncertainty in the determination of the spectral center and FWHM for each channel are also reported. This paper presents results from an investigation of the sensitivity of AVIRIS-measured upwelling radiance to errors in spectral calibration. Based on this sensitivity analysis in conjunction with earlier work, an improved spectral calibration requirement for AVIRIS is proposed.

Green, Robert O.↗

Characterization and Analysis of InGaAsSb Detectors

Profiling of atmospheric CO2 at 2 micron wavelength using the LIDAR technique, has recently gained interest. Although several detectors might be suitable for this application, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the detector signal-to-noise ratio and minimizes the background signal, thereby increasing the device sensitivity and dynamic range. Detectors meeting the above idealized criteria are commercially unavailable for this particular wavelength. In this paper, the characterization and analysis of Sb-based detectors for 2 micron lidar applications are presented. The detectors were manufactured by AstroPower, Inc., with an InGaAsSb absorbing layer and AlGaAsSb passivating layer. The characterization experiments included spectral response, current versus voltage and noise measurements. The effect of the detectors bias voltage and temperature on its performance, have been investigated as well. The detectors peak responsivity is located at the 2 micron wavelength. Comparing three detector samples, an optimization of the spectral response around the 2 micron wavelength, through a narrower spectral period was observed. Increasing the detector bias voltage enhances the device gain at the narrow spectral range, while cooling the device reduces the cut-off wavelength and lowers its noise. Noise-equivalent-power analysis results in a value as low as 4 x 10(exp -12) W/Hz(exp 1/2) corresponding to D* of 1 x 10(exp 10) cmHz(exp 1/2)/W, at -1 V and 20 C. Discussions also include device operational physics and optimization guidelines, taking into account peculiarity of the Type II heterointerface and transport mechanisms under these conditions.

Abedin, M. Nurul↗

Insights into the thermal history of carbon fibers using Raman spectroscopy and a novel kinetic model

Carbon fibers and carbon fiber composites are applied in high-performance applications, but a key consideration for application is their relative sensitivity to oxidative environments. To enable in-situ characterization of carbon fibers exposed to oxidative conditions, the Raman spectral response of T700 carbon fibers that have been exposed to a variety of dwell temperatures is reported herein with dwell times reaching up to 1 month. Here, we evaluate the spectra holistically by using integrated absolute difference analysis. By combining this analysis with straightforward kinetic models, we connect the total Raman spectral response to the temperature-time curve that could yield such a shift in spectral parameters. Our work connects the Raman spectral response of carbon fibers to their thermal history and can easily be extended to other graphitic materials, such as nuclear graphite.

36 MATERIALS SCIENCE↗

Optically stimulated electron emission - Current-voltage response and spectral sensitivity

A highly reproducible optically stimulated electron emission (OSEE) response steel was achieved in laboratory conditions through suppression of surface photochemistry by replacing air with argon. This permitted the characterization of the OSEE process on D6AC steel as a photodiode. With a low-pressure mercury light source, most of the OSEE current is attributed to photoelectrons released by the 185-nm mercury line with only about 5 percent of the photocurrent associated with the 254-nm line. The forward current-voltage characteristic of the OSEE diode is linear for small fields changing to a square root response at larger fields. These results are all consistent with established theories.

Welch, Christopher S.↗

Spectral Fidelity of Earth's Terrestrial and Aquatic Ecosystems

The Surface Biology and Geology (SBG) investigation will create global maps of spectral surface reflectance and emissivity at a cadence of 16 days or better, with coverage to address global questions about Earth's geology, cryosphere and ecosystems. The revolutionary potential poses a commensurate challenge: creating contiguous maps free from regional biases induced by atmosphere, observation geometry, or inversion error. This will require an accurate calibration with precise knowledge of each channel's spectral response. Here, we quantify the impact of spectral calibration on SBG's aquatic and terrestrial ecosystem objectives. We find that contemporary algorithms for ecosystem trait retrieval demand more accurate spectral calibration than historical missions. Errors due to drift or spatial nonuniformity in the wavelength calibration that have previously been considered acceptable can cause systematic errors larger than the instrument noise and of the same order as the variability SBG aims to measure. Moreover, their impact on atmospheric correction can induce climate-dependent systematic errors that thwart comparisons between ecosystems. These results underscore the importance of spectral response accuracy in SBG mission design.

imaging spectroscopy↗

Laser damage tests on InSb photodiodes at 1.064 micron and 0.532 micron

InSb photodiodes were examined for performance degradation after pulsed laser illumination at 0.532 micron and 1.064 micron. Incident laser powers ranged from 6 x 10 exp-18 micron-watts to 16 micron-watts in a 50 pm diameter spot. Dark current and spectral response were both measured before and after illumination. Dark current measurements were taken with the diode blanked off and viewing only 77 K surfaces. Long term stability tests demonstrated that the blackbody did not exhibit long term drifts. Other tests showed that room temperature variations did not affect the diode signal chain or the digitization electronics used in data acquisition. Results of the experiment show that the diodes did not exhibit changes in dark current or spectral response performance as a result of the laser illumination. A typical change in diode spectral response (before/after laser exposure) was about 0.2 percent +/- 0.2 percent.

Bearman, G. H.↗

Learnability of Red-Green Opponency

Lennie, Haake, and Williams found that in the lateral geniculate nucleus (LGN), parvocellular unit responses are consistent with the hypothesis that their input connectivity is blind to the difference between middle-wavelength-sensitive (MWS) and long-wavelength-sensitive (LWS) cones. Most of their cells have a total MWS input weight opposite in sign and similar in magnitude to their total LWS input weight. If these weights are exactly balanced, the construction of a red-green opponent system from such units is simple: such units need only be aligned so the signs of their outputs agree. Ahumada and Mulligan described an associative learning process which can accomplish this alignment. If the units are not balanced (carry some luminance information), the strong overlap between the MWS and LWS spectral responses can cause units to agree more on the basis of luminance, and the associative process fails to produce red-green opponency. The learning theory requires that the LGN units be nearly balanced (more strongly encode chromaticity than luminance) and quantitatively expresses the requirement: the principal component of the LGN outputs must be in the red-green rather than the luminance direction. We show that the cone weights of the monkey LGN cells measured by Derrington, Krauskopf, and Lennie can satisfy this learnability criterion even if the MWS spectral response is close to the LWS spectral response, simulating anomalous trichromacy. The learnability theory provides a source of visual system variation for explaining why different anomalous trichromats may make the same average anomaloscope match (same pigments), but have either narrow (good opponent learning) or wide (poor learning) ranges of acceptable matches.

Ahumada, Albert J., Jr.↗

Spectral characterization of the LANDSAT-D multispectral scanner subsystems

Relative spectral response data for the multispectral scanner subsystems (MSS) to be flown on LANDSAT-D and LANDSAT-D backup, the protoflight and flight models, respectively, are presented and compared to similar data for the Landsat 1,2, and 3 subsystems. Channel-bychannel (six channels per band) outputs for soil and soybean targets were simulated and compared within each band and between scanners. The two LANDSAT-D scanners proved to be nearly identical in mean spectral response, but they exhibited some differences from the previous MSS's. Principal differences between the spectral responses of the D-scanners and previous scanners were: (1) a mean upper-band edge in the green band of 606 nm compared to previous means of 593 to 598 nm; (2) an average upper-band edge of 697 nm in the red band compared to previous averages of 701 to 710 nm; and (3) an average bandpass for the first near-IR band of 702-814 nm compared to a range of 693-793 to 697-802 nm for previous scanners. These differences caused the simulated D-scanner outputs to be 3 to 10 percent lower in the red band and 3 to 11 percent higher in the first near-IR band than previous scanners for the soybeans target. Otherwise, outputs from soil and soybean targets were only slightly affected. The D-scanners were generally more uniform from channel to channel within bands than previous scanners.

Markham, B. L.↗