Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “simultaneous operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Se-SAD serial femtosecond crystallography datasets from selenobiotinyl-streptavidin

We provide a detailed description of selenobiotinyl-streptavidin (Se-B SA) co-crystal datasets recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS) for selenium single-wavelength anomalous diffraction (Se-SAD) structure determination. Se-B SA was chosen as the model system for its high affinity between biotin and streptavidin where the sulfur atom in the biotin molecule (C 10 H 16 N 2 O 3 S) is substituted with selenium. The dataset was collected at three different transmissions (100, 50, and 10%) using a serial sample chamber setup which allows for two sample chambers, a front chamber and a back chamber, to operate simultaneously. Diffraction patterns from Se-B SA were recorded to a resolution of 1.9 Å. The dataset is publicly available through the Coherent X-ray Imaging Data Bank (CXIDB) and also on LCLS compute nodes as a resource for research and algorithm development.

36 MATERIALS SCIENCE↗

Parallelizable microfluidic dropmakers with multilayer geometry for the generation of double emulsions

Microfluidic devices enable the production of uniform double emulsions with control over droplet size and shell thickness. However, the limited production rate of microfluidic devices precludes the use of monodisperse double emulsions for industrial-scale applications, which require large quantities of droplets. To increase throughput, devices can be parallelized to contain many dropmakers operating simultaneously in one chip, but this is challenging to do for double emulsion dropmakers. Production of double emulsions requires dropmakers to have both hydrophobic and hydrophilic channels, requiring spatially precise patterning of channel surface wettability. Precise wettability patterning is difficult for devices containing multiple dropmakers, posing a significant challenge for parallelization. In this paper, we present a multilayer dropmaker geometry that greatly simplifies the process of producing microfluidic devices with excellent spatial control over channel wettability. Wettability patterning is achieved through the independent functionalization of channels in each layer prior to device assembly, rendering the dropmaker with a precise step between hydrophobic and hydrophilic channels. We report this device geometry enables uniform wettability patterning of parallelized dropmakers, providing a scalable approach for the production of double emulsions.

36 MATERIALS SCIENCE↗

The role of the relative voltage and phase for frequency coupling in a dual-frequency capacitively coupled plasma

Frequency coupling in multifrequency discharges is a complex nonlinear interaction of the different frequency components. An alpha-mode low pressure rf capacitively coupled plasma operated simultaneously with two frequencies is investigated and the coupling of the two frequencies is observed to greatly influence the excitation and ionization within the discharge. Through this, plasma production and sustainment are dictated by the corresponding electron dynamics and can be manipulated through the dual-frequency sheath. These mechanisms are influenced by the relative voltage and also the relative phase of the two frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Search for GeV-TeV Emission from GRBs Using the Milagro Detector

The Milagro detector surveyed the sky almost continuously in the very high energy regime from January 2000 through March 2008. During that time, over 130 GRBs have been detected and well localized by satellites within its 2 sr field of view. We have used Milagro data to search for >1 GeV emission from these bursts. Milagro is a water Cerenkov detector designed primarily for observations in the 0.1-100 TeV energy range. Milagro was operated simultaneously in both standard mode and 'scaler' mode. In the standard analysis, the direction and energy of an incoming particle is determined by reconstructing the air shower produced when the particle interacts in the Earth's atmosphere. In 'scaler' mode, the rates of the PMTs are monitored and fluctuations temporally coincident with GRBs are searched for. No significant emission was discovered using either method and the upper limit on the emission for each burst with known redshift is reported.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time x-ray response of biocompatible solution gate AlGaN/GaN high electron mobility transistor devices

We present the real-time x-ray irradiation response of charge and pH sensitive solution gate AlGaN/GaN high electron mobility transistors. The devices show stable and reproducible behavior under and following x-ray radiation, including a linear integrated response with dose into the muGy range. Titration measurements of devices in solution reveal that the linear pH response and sensitivity are not only retained under x-ray irradiation, but an irradiation response could also be measured. Since the devices are biocompatible, and can be simultaneously operated in aggressive fluids and under hard radiation, they are well-suited for both medical radiation dosimetry and biosensing applications.

36 MATERIALS SCIENCE↗

A reversible time-of-flight detector for use in pseudocontinuous resonance enhanced multiphoton (pc-REMPI) detection

A time-of-flight coincidence detector is demonstrated. This detector is optimized for use in a pseudocontinuous resonance enhanced multiphoton ionization scheme that requires photoelectrons and photoions to be detected in coincidence. The detector utilizes two simultaneously operating charged particle detectors, one for the detection of electrons and the other for the detection of ions. In order to allow for field reversal, the detectors are physically identical, differing only by the value of applied voltages. Particular attention is given to the implementation of a charge-to-voltage transducer that allows for subnanosecond detection of both electrons and ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delay time calculation for dual-wavelength quantum cascade lasers

In this paper, we calculate the turn-on delay (t{sub th}) and buildup (Δt) times of a midinfrared quantum cascade laser operating simultaneously on two laser lines having a common upper level. The approach is based on the four-level rate equations model describing the variation of the electron number in the states and the photon number present within the cavity. We obtain simple analytical formulae for the turn-on delay and buildup times that determine the delay times and numerically apply our results to both the single and bimode states of a quantum cascade laser, in addition the effects of current injection on t{sub th} and Δt are explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transmission for the other wavelengths for downstream use. The second crystal is about 300 μm thick and makes the exit beam of the monochromator parallel to the incoming beam with an offset of 600 mm. Here we present details on the monochromator design and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock wave compression of hexagonal-close-packed metal single crystals: Time-dependent, anisotropic elastic-plastic response of beryllium

Understanding and modeling the response of hcp metals to high stress impulsive loading is challenging because the lower crystal symmetry, compared to cubic metals, results in a significantly more complex material response. To gain insight into the inelastic deformation of hcp metals subjected to high dynamic stresses, shock wave compression of single crystals provides a useful approach because different inelastic deformation mechanisms can be examined selectively by shock compression along different crystal orientations. As a representative example, we report, here, on wave propagation simulations for beryllium (Be) single crystals shocked along the c-axis, a-axis, and several low-symmetry directions to peak stresses reaching 7 GPa. The simulations utilized a time-dependent, anisotropic material model that incorporated dislocation dynamics, deformation twinning, and shear cracking based descriptions of inelastic deformation. The simulation results showed good overall agreement with measured wave profiles for all the different crystal orientations examined [Pope and Johnson, J. Appl. Phys. 46, 720 (1975)], including features arising from wave mode coupling due to the highly anisotropic inelastic response of Be. This good agreement demonstrates that the measured profiles can be understood in terms of dislocation slip along basal, prismatic, and pyramidal planes, together with deformation twinning along (101{sup ¯}2) planes. Our results show that the response of shocked Be single crystals involves the simultaneous operation of multiple, distinct inelastic deformation mechanisms for all orientations except the c-axis. For shocked c-axis Be, the measured wave profiles do not provide good discrimination between pyramidal slip and other inelastic deformation mechanisms, such as shear cracking. The findings presented here provide insight into the complex inelastic deformation response of shocked Be single crystals and are expected to be useful for other hcp crystals. More broadly, the present work demonstrates the potential of shock wave propagation along low-symmetry directions to examine, and discriminate between, different inelastic deformation mechanisms in crystalline solids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High performance techniques for micro channel plate computations in photo multipliers

Monte Carlo - MC methods, requiring heavy computations of large data volume, can be used to predict the amplitude distribution and variance of outputted electron charge in Micro Channel Plates - MCPs, which are fed with primary emitted electrons in their inputs. The concept of parallel and serial combination of separate stages of such stochastic processes, which can be applied in MCP systems and simulated using MC computations, has recently proposed and shown interesting theorems and results. Separating the electron multiplication procedures, occurring in the channels of MCP systems, into sub-procedures, which are similar in nature and occur either in parallel or in consecutive manners, is equivalent to splitting the relevant stochastic system calculations into smaller ones, which can be performed concurrently and/or sequentially. In this way, calculations similar in nature, can be executed only once, thus, eliminating a great percentage of heavy computations. However, when designing and implementing the calculation inferences of the derived theorems using High Performance Computation - HPC techniques, the overall computation cost can further and significantly be reduced. In this paper, the hardware mappings of the relevant theorem inferences onto parallel computing architectures, resulting in circuits of computing blocks for calculation purposes of MCP system stochastic processes, are investigated. Each of the designed and implemented computing circuits corresponds to a theorem inference or to a combination of inferences. The parallelism of the proposed circuits consists of both the concurrent functioning of all the system blocks and of the simultaneous operation of each block, which is processing pieces of data, for many parts of the whole circuit in which it belongs. All the circuits are designed and tested using Altera Quartus II environment and can be implemented as chips, which can be incorporated in computing devices to assist Monte Carlo computations for the estimation of different MCP electron multiplication system performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin filter and spin valve in ferromagnetic graphene

We propose and demonstrate that a EuO-induced and top-gated graphene ferromagnetic junction can be simultaneously operated as a spin filter and a spin valve. We attribute such a remarkable result to a coexistence of a half-metal band and a common energy gap for opposite spins in ferromagnetic graphene. We show that both the spin filter and the spin valve can be effectively controlled by a back gate voltage, and they survive for practical metal contacts and finite temperature. Specifically, larger single spin currents and on-state currents can be reached with contacts with work functions similar to graphene, and the spin filter can operate at higher temperature than the spin valve.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous differential spinning disk fluorescence optical sectioning microscopy and nanomechanical mapping atomic force microscopy

Combined microscopy techniques offer the life science research community a powerful tool to investigate complex biological systems and their interactions. Here, we present a new combined microscopy platform based on fluorescence optical sectioning microscopy through aperture correlation microscopy with a Differential Spinning Disk (DSD) and nanomechanical mapping with an Atomic Force Microscope (AFM). The illumination scheme of the DSD microscope unit, contrary to standard single or multi-point confocal microscopes, provides a time-independent illumination of the AFM cantilever. This enables a distortion-free simultaneous operation of fluorescence optical sectioning microscopy and atomic force microscopy with standard probes. In this context, we discuss sample heating due to AFM cantilever illumination with fluorescence excitation light. Integration of a DSD fluorescence optical sectioning unit with an AFM platform requires mitigation of mechanical noise transfer of the spinning disk. We identify and present two solutions to almost annul this noise in the AFM measurement process. The new combined microscopy platform is applied to the characterization of a DOPC/DOPS (4:1) lipid structures labelled with a lipophilic cationic indocarbocyanine dye deposited on a mica substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparing the MAX IV storage rings for timing-based experiments

Time-resolved experimental techniques are increasingly abundant at storage ring facilities. Recent developments in accelerator technology and beamline instrumentation allow for simultaneous operation of high-intensity and timing-based experiments. The MAX IV facility is a state-of-the-art synchrotron light source in Lund, Sweden, that will come into operation in 2016. As many storage ring facilities are pursuing upgrade programs employing strong-focusing multibend achromats and passive harmonic cavities (HCs) in high-current operation, it is of broad interest to study the accelerator and instrumentation developments required to enable timing-based experiments at such machines. In particular, the use of hybrid filling modes combined with pulse picking by resonant excitation or pseudo single bunch has shown promising results. These methods can be combined with novel beamline instrumentation, such as choppers and instrument gating. In this paper we discuss how these techniques can be implemented and employed at MAX IV.

43 PARTICLE ACCELERATORS↗

Shock compression/release of magnesium single crystals along a low-symmetry orientation: Role of basal slip

To gain insight into the relative contributions of different plastic deformation mechanisms, particularly basal slip, for shocked hexagonal close-packed (hcp) metals, magnesium (Mg) single crystals were subjected to shock compression and release along a low-symmetry (LS) orientation to 1.9 and 4.8 GPa elastic impact stresses. LS-axis is a “non-specific” direction resulting in propagation of quasi-longitudinal and quasi-shear waves. Wave profiles, measured using laser interferometry, show a small elastic wave followed by two plastic waves in compression; release wave profiles exhibited a structured response for the higher stress and a smooth response for the lower stress. The LS-axis wave profiles are significantly different than profiles published previously for c- and a -axes, demonstrating that Mg single crystals exhibit strong anisotropy under shock compression/release. Numerical simulations, using a time-dependent anisotropic modeling framework, show that shock wave loading along the LS-axis involves simultaneous operation of multiple deformation mechanisms. Shock compression along LS-axis is dominated by basal slip while prismatic and pyramidal I {$10\bar{1}1$} $\langle$ $11\bar{2}3$ $\rangle$ slip play a smaller role; coupling between longitudinal and shear deformations was observed. The unloading response is dominated by basal slip with some contribution from prismatic slip; pyramidal I slip is not activated. The present results, unlike results obtained for c - and a -axes, show that the deformation mechanism observed under quasi-static loading conditions along LS-axis is not sufficient to determine shock response along this orientation. Finally, although requiring numerical simulations for wave analysis, shock propagation along a LS orientation provides new insights into the plastic deformation response of hcp metal single crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous-wave solid-state two-Stokes Raman laser

We report an experimental study of the first cw solid-state Raman laser operating simultaneously at the frequencies of the first and second Stokes components. Simultaneous generation is ensured by a cavity with an enhanced finesse at both Stokes frequencies. The threshold pump powers for the first (3.4 W) and second (3.67 W) Stokes components suggest that the second Stokes generation follows a cascade mechanism. We demonstrate for the first time Raman conversion with intensity stability exceeding the pump radiation stability and show that this approach may find application in Raman spectroscopy. (special issue devoted to the 80th birthday of S.A. Akhmanov)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE POSSIBLE EXISTENCE OF SHORT-PERIOD g-MODE INSTABILITIES POWERED BY NUCLEAR-BURNING SHELLS IN POST-ASYMPTOTIC GIANT BRANCH H-DEFICIENT (PG1159-TYPE) STARS

We present a pulsational stability analysis of hot post-asymptotic giant branch (AGB) H-deficient pre-white dwarf stars with active He-burning shells. The stellar models employed are state-of-the-art equilibrium structures representative of PG1159 stars derived from the complete evolution of the progenitor stars, through the thermally pulsing AGB phase and born-again episode. On the basis of fully nonadiabatic pulsation computations, we confirmed theoretical evidence for the existence of a separate PG1159 instability strip in the log T {sub eff}-log g diagram characterized by short-period g-modes excited by the {epsilon}-mechanism. This instability strip partially overlaps the already known GW Vir instability strip of intermediate/long-period g-modes destabilized by the classical {kappa}-mechanism acting on the partial ionization of C and/or O in the envelope of PG1159 stars. We found that PG1159 stars characterized by thick He-rich envelopes and located inside this overlapping region could exhibit both short and intermediate/long periods simultaneously. As a natural application of our results, we study the particular case of VV 47, a pulsating planetary nebula nucleus (PG1159 type) that is particularly interesting because it has been reported to exhibit a rich and complex pulsation spectrum including a series of unusually short pulsation periods. We found that the long periods exhibited by VV 47 can be readily explained by the classical {kappa}-mechanism, while the observed short-period branch below {approx}300 s could correspond to modes triggered by the He-burning shell through the {epsilon}-mechanism, although more observational work is needed to confirm the reality of these short-period modes. Were the existence of short-period g-modes in this star convincingly confirmed by future observations, VV 47 could be the first known pulsating star in which both the {kappa}-mechanism and the {epsilon}-mechanism of mode driving are simultaneously operating.

79 ASTRONOMY AND ASTROPHYSICS↗

Current ramp-up studies for NSTX-U in support of the development of non-inductive current ramp-up scenarios in STs

The Spherical Tokamak (ST) is a low-aspect-ratio tokamak projected to enable simultaneous operation at high normalized toroidal beta and high bootstrap current fraction. However, a compact ST reactor cannot be built with a full-sized solenoid. The remaining current required for sustained operation must be ramped up non-inductively. Sustained 100% non-inductive current drive at the MA level has not yet been demonstrated on an ST. Non-inductive current ramp-up is therefore a more challenging objective that the NSTX-U research program aims to address. In support of this development, free-boundary TRANSP simulations have been used to develop a current ramp-up scenario in which a significant fraction of the current is driven non-inductively by a combination of neutral-beam and bootstrap current drive. The resulting discharge has properties favorable for non-inductive current drive, such as a low normalized internal plasma inductance of approximately 0.45, a minimum safety factor exceeding 2, and a slightly reversed-shear q-profile. In these discharges, the plasma current ramps to 900 kA within 250 ms in an L-mode configuration, with varying electron density and density profiles. These discharges should be suitable for next-step NSTX-U experiments aimed at generating a robust L-mode fiducial scenario with low central solenoid flux consumption, which could be progressively improved as new NSTX-U experimental discharges are developed.

Raman, Roger [Univ. of Washington, Seattle, WA (Un↗

MAGNETIC ACTIVITY CYCLES IN THE EXOPLANET HOST STAR {epsilon} ERIDANI

The active K2 dwarf {epsilon} Eri has been extensively characterized both as a young solar analog and more recently as an exoplanet host star. As one of the nearest and brightest stars in the sky, it provides an unparalleled opportunity to constrain stellar dynamo theory beyond the Sun. We confirm and document the 3-year magnetic activity cycle in {epsilon} Eri originally reported by Hatzes and coworkers, and we examine the archival data from previous observations spanning 45 years. The data show coexisting 3-year and 13-year periods leading into a broad activity minimum that resembles a Maunder minimum-like state, followed by the resurgence of a coherent 3-year cycle. The nearly continuous activity record suggests the simultaneous operation of two stellar dynamos with cycle periods of 2.95 {+-} 0.03 years and 12.7 {+-} 0.3 years, which, by analogy with the solar case, suggests a revised identification of the dynamo mechanisms that are responsible for the so-called 'active' and 'inactive' sequences as proposed by Boehm-Vitense. Finally, based on the observed properties of {epsilon} Eri, we argue that the rotational history of the Sun is what makes it an outlier in the context of magnetic cycles observed in other stars (as also suggested by its Li depletion), and that a Jovian-mass companion cannot be the universal explanation for the solar peculiarities.

79 ASTRONOMY AND ASTROPHYSICS↗