Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shot optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

XFEL diffraction: Developing processing methods to optimize data quality

Serial crystallography, using either femtosecond X-ray pulses from free-electron laser sources or short synchrotron-radiation exposures, has the potential to reveal metalloprotein structural details while minimizing damage processes. However, deriving a self-consistent set of Bragg intensities from numerous still-crystal exposures remains a difficult problem, with optimal protocols likely to be quite different from those well established for rotation photography. Here several data processing issues unique to serial crystallography are examined. It is found that the limiting resolution differs for each shot, an effect that is likely to be due to both the sample heterogeneity and pulse-to-pulse variation in experimental conditions. Shots with lower resolution limits produce lower-quality models for predicting Bragg spot positions during the integration step. Also, still shots by their nature record only partial measurements of the Bragg intensity. An approximate model that corrects to the full-spot equivalent (with the simplifying assumption that the X-rays are monochromatic) brings the distribution of intensities closer to that expected from an ideal crystal, and improves the sharpness of anomalous difference Fourier peaks indicating metal positions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent efforts of vapour-phase strategies for EUV resist toward high- and hyper-NA extreme ultraviolet lithography

Extreme ultraviolet lithography (EUVL, λ = 13.5 nm) is critical for sub-1 nm technology nodes but remains constrained by inherent trade-offs among resolution, line-edge roughness (LER), and sensitivity. Stochastic effects originating from photon shot noise, low-energy secondary electron blur, and the random distribution of resist components further limit its advancement toward high numerical-aperture (NA, NA = 0.55) and hyper-NA (NA ≥0.75) EUVL. While the optimization of spin-on chemically amplified resists (CARs) continues, metal-oxide resists (MORs) have emerged as strong candidates for next-generation EUVL by incorporating metals with high EUV absorption coefficients, which enhances both resist sensitivity and etch resistance during pattern transfer. Besides spin-coating, recent advances in vapour-phase techniques, such as vapour-phase infiltration (VPI), chemical vapour deposition (CVD), and molecular atomic layer deposition (MALD), offer promising pathways to achieve new resist platforms, such as dry resists, that satisfy the stringent thickness and uniformity requirements of next-generation EUVL. These methods enable the direct incorporation of metal species into existing resist matrices or the formation of hybrid inorganic–organic resist platforms, thereby improving film uniformity, etch durability, and pattern fidelity while mitigating stochastic defects. This review highlights the latest advancements in vapour-phase-synthesized EUV resists, emphasizing material design, lithographic performance, and the underlying exposure mechanisms. Although still emerging, vapour-phase strategies are paving the way for an all-dry integration framework that could improve EUV patterning workflows and meet the demands of future technology nodes.

36 MATERIALS SCIENCE↗

Characterization of a novel, short pulse laser-driven neutron source

We present a full characterization of a short pulse laser-driven neutron source. Neutrons are produced by nuclear reactions of laser-driven ions deposited in a secondary target. The emission of neutrons is a superposition of an isotropic component into 4π and a forward directed, jet-like contribution, with energies ranging up to 80 MeV. A maximum flux of 4.4 × 10{sup 9} neutrons/sr has been observed and used for fast neutron radiography. On-shot characterization of the ion driver and neutron beam has been done with a variety of different diagnostics, including particle detectors, nuclear reaction, and time-of-flight methods. The results are of great value for future optimization of this novel technique and implementation in advanced applications.

07 ISOTOPE AND RADIATION SOURCES↗

Astrophysics & cosmology from line intensity mapping vs galaxy surveys

Line intensity mapping (LIM) proposes to efficiently observe distant faint galaxies and map the matter density field at high redshift. Building upon the formalism in a companion paper, we first highlight the degeneracies between cosmology and astrophysics in LIM. We discuss what can be constrained from measurements of the mean intensity and redshift-space power spectra. With a sufficient spectral resolution, the large-scale redshift-space distortions of the 2-halo term can be measured, helping to break the degeneracy between bias and mean intensity. With a higher spectral resolution, measuring the small-scale redshift-space distortions disentangles the 1-halo and shot noise terms. Additionally, cross-correlations with external galaxy catalogs or lensing surveys further break degeneracies. We derive requirements for experiments similar to SPHEREx, HETDEX, CDIM, COMAP and CONCERTO. We then revisit the question of the optimality of the LIM observables, compared to galaxy detection, for astrophysics and cosmology. We use a matched filter to compute the luminosity detection threshold for individual sources. We show that LIM contains information about galaxies too faint to detect, in the high-noise or high-confusion regimes. We quantify the sparsity and clustering bias of the detected sources and compare them to LIM, showing in which cases LIM is a better tracer of the matter density. We extend previous work by answering these questions as a function of Fourier scale, including for the first time the effect of cosmic variance, pixel-to-pixel correlations, luminosity-dependent clustering bias and redshift-space distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Transformer-powered surrogates close the ICF simulation-experiment gap with extremely limited data

Abstract Recent advances in machine learning, specifically transformer architecture, have led to significant advancements in commercial domains. These powerful models have demonstrated superior capability to learn complex relationships and often generalize better to new data and problems. This paper presents a novel transformer-powered approach for enhancing prediction accuracy in multi-modal output scenarios, where sparse experimental data is supplemented with simulation data. The proposed approach integrates transformer-based architecture with a novel graph-based hyper-parameter optimization technique. The resulting system not only effectively reduces simulation bias, but also achieves superior prediction accuracy compared to the prior method. We demonstrate the efficacy of our approach on inertial confinement fusion experiments, where only 10 shots of real-world data are available, as well as synthetic versions of these experiments.

97 MATHEMATICS AND COMPUTING↗

Optimized Quantum Compilation for Near-Term Algorithms with OpenPulse

Quantum computers are traditionally operated by programmers at the granularity of a gate-based instruction set. However, the actual device-level control of a quantum computer is performed via analog pulses. Here, we introduce a compiler that exploits direct control at this microarchitectural level to achieve significant improvements for quantum programs. Unlike quantum optimal control, our approach is bootstrapped from existing gate calibrations and the resulting pulses are simple. Our techniques are applicable to any quantum computer and realizable on current devices. We validate our techniques with millions of experimental shots on IBM quantum computers, controlled via the OpenPulse control interface. For representative benchmarks, our pulse control techniques achieve both 1.6x lower error rates and 2x faster execution time, relative to standard gate-based compilation. These improvements are critical in the near-term era of quantum computing, which is bottlenecked by error rates and qubit lifetimes.

Gokhale, Pranav↗

Active meta-learning for predicting and selecting perovskite crystallization experiments

Autonomous experimentation systems use algorithms and data from prior experiments to select and perform new experiments in order to meet a specified objective. In most experimental chemistry situations, there is a limited set of prior historical data available, and acquiring new data may be expensive and time consuming, which places constraints on machine learning methods. Active learning methods prioritize new experiment selection by using machine learning model uncertainty and predicted outcomes. Meta-learning methods attempt to construct models that can learn quickly with a limited set of data for a new task. Here in this paper, we applied the model-agnostic meta-learning (MAML) model and the Probabilistic LATent model for Incorporating Priors and Uncertainty in few-Shot learning (PLATIPUS) approach, which extends MAML to active learning, to the problem of halide perovskite growth by inverse temperature crystallization. Using a dataset of 1870 reactions conducted using 19 different organoammonium lead iodide systems, we determined the optimal strategies for incorporating historical data into active and meta-learning models to predict reaction compositions that result in crystals. We then evaluated the best three algorithms (PLATIPUS and active-learning k-nearest neighbor and decision tree algorithms) with four new chemical systems in experimental laboratory tests. With a fixed budget of 20 experiments, PLATIPUS makes superior predictions of reaction outcomes compared to other active-learning algorithms and a random baseline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancement of Optical Emission and Ion Currents in a Laser Produced Silicon Plasma by Femtosecond Laser-Induced Periodic Surface Structuring

Laser-induced periodic surface structuring is a powerful technique for modifying the surface properties of solids. Using ultrashort pulses from a Ti:Sapphire laser (800 nm, 100 fs) we have fabricated nanoscale order laser-induced periodic surface structures (LIPSS) on a silicon (100) surface. The LIPSS patterns are found to be strongly dependent on the laser pulse energy, state of polarization, number of shots delivered on the target, and the ambient pressure. The role of laser wavelength is studied by using the second harmonic output (400 nm) also for fabrication. Large area (5x4 mm2) surface structuring has been carried out at atmospheric pressure after optimizing the laser parameters at 800 nm. The patterned silicon surface shows a substantial reduction in the reflection of incident light over a wide range of wavelengths, in comparison to plain silicon. Moreover, when used for laser induced breakdown spectroscopy (LIBS) experiments, enhanced optical emission and ion current have been observed from the patterned surface. This indicates that coupling of laser energy to the surface is enhanced in the case of patterned silicon. While spectral lines emitted by doubly ionized silicon have been observed from the patterned surface, the plain surface gives lines from singly ionized silicon only. A discernible enhancement has been measured in both optical (50-90%) and electrical (34%) signals from the plasma generated on the patterned surface. These results confirm that LIPSS is a versatile method for enhancing the coupling of laser energy on to irradiated solid surfaces.

ion currents, optical emission, laser produced sil↗

Inferring Quantum Network Topology Using Local Measurements

Statistical correlations that can be generated across the nodes in a quantum network depend crucially on its topology. However, this topological information might not be known a priori, or it may need to be verified. In this paper, we propose an efficient protocol for distinguishing and inferring the topology of a quantum network. We leverage entropic quantities-namely, the von Neumann entropy and the measured mutual information-as well as measurement covariance to uniquely characterize the topology. We show that the entropic quantities are sufficient to distinguish two networks that prepare GHZ states. Moreover, if qubit measurements are available, both entropic quantities and covariance can be used to infer the network topology without state-preparation assumptions. We show that the protocol can be entirely robust to noise and can be implemented via quantum variational optimization. Numerical experiments on both classical simulators and quantum hardware show that covariance is generally more reliable for accurately and efficiently inferring the topology, whereas entropy-based methods are often better at identifying the absence of entanglement in the low-shot regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulse intensity characterization of the LCLS nanosecond double-bunch mode of operation

The recent demonstration of the 'nanosecond double-bunch' operation mode, i.e. two X-ray pulses separated in time between 0.35 and hundreds of nanoseconds and by increments of 0.35 ns, offers new opportunities to investigate ultrafast dynamics in diverse systems of interest. However, in order to reach its full potential, this mode of operation requires the precise characterization of the intensity of each X-ray pulse within each pulse pair for any time separation. Here, a transmissive single-shot diagnostic that achieves this goal for time separations larger than 0.7 ns with a precision better than 5% is presented. Lastly, it also provides real-time monitoring feedback to help tune the accelerator parameters to deliver double pulse intensity distributions optimized for specific experimental goals.

43 PARTICLE ACCELERATORS↗

On measuring stimulated photon–photon scattering using multiple ultraintense lasers

Stimulated photon–photon scattering is a predicted consequence of quantum electrodynamics that has yet to be measured directly. Measuring the cross section for stimulated photon–photon scattering is the aim of a flagship experiment for NSF OPAL, a proposed laser user facility with two, 25-PW beamlines. We present optimized experimental designs for achieving this challenging and canonical measurement. A family of experimental geometries is identified that satisfies the momentum- and energy-matching conditions for two selected laser frequency options. Numerical models predict a maximum signal exceeding 1000 scattered photons per shot at the experimental conditions envisaged at NSF OPAL. Experimental requirements on collision geometry, polarization, cotiming and copointing, background suppression, and diagnostic technologies are investigated numerically. These results confirm that a beam cotiming shorter than the pulse duration and control of the copointing on a scale smaller than the shortest laser wavelength are needed to robustly scatter photons on a per-shot basis. Finally, we assess the bounds that a successful execution of this experiment may place on the mass scale of Born–Infeld nonlinear electrodynamics beyond the standard model of physics.

Beyond the Standard Model↗

Summary of Disposable Debris Shields (DDS) Analysis for Development of Solid Debris Collection at NIF

Collection of solid debris from the National Ignition Facility (NIF) is being developed both as a diagnostic tool and as a means for measuring nuclear reaction cross sections relevant to the Stockpile Stewardship Program and nuclear astrophysics. The concept is straightforward; following a NIF shot, the debris that is produced as a result of the capsule and hohlraum explosion would be collected and subsequently extracted from the chamber. The number of nuclear activations that occurred in the capsule would then be measured through a combination of radiation detection and radiochemical processing followed by mass spectrometry. Development of the catcher is challenging due to the complex environment of the NIF target chamber. The collector surface is first exposed to a large photon flux, followed by the debris wind that is produced. The material used in the catcher must be mechanically strong in order to withstand the large amount of energy it is exposed to, as well as be chemically compatible with the form and composition of the debris. In addition, the location of the catcher is equally important. If it is positioned too close to the center of the target chamber, it will be significantly ablated, which could interfere with the ability of the debris to reach the surface and stick. If it is too far away, the fraction of the debris cloud collected will be too small to result in a statistically significant measurement. Material, geometric configuration, and location must all be tested in order to design the optimal debris collection system for NIF. One of the first ideas regarding solid debris collection at NIF was to use the disposable debris shields (DDS), which are fielded over the final optics assemblies (FOA) 7 m away from the center of the target chamber. The DDS are meant to be replaced after a certain number of shots, and if the shields could be subsequently analyzed after removal, it would serve as a mechanism for fielding a relatively large collection area through the use of a part meant to be replaced regularly. The solid angle covered by one of the shields is roughly 10 -4 of 4π. If several shields were analyzed at once, it would increase the solid angle of the collection area accordingly. The glass shields consist of ammonia hardened silica with a sol gel coating and kapton tape around the edge. The square sheets are 14-inch on each side. The original shields were 1 mm thick, but it was determined that a thicker shield (3.3 mm) was more effective in preventing debris from reaching the FOA. The Solid Radchem group received two sets of DDS as part of our evaluation of the potential use of the DDS as solid debris collectors. The first set consisted of two 3.3 mm shields, one each from the top and bottom of the chamber (the '3mm set'). The second set consisted of four 1mm shields, one from the top of the chamber and the other three from the bottom (the 'IFSA set'). For each set, the shields were cut into smaller subsamples, which were then imaged using scanning electron microscopy (SEM) followed by chemical leaching and mass spectrometry. The purpose was to evaluate both the quantity and identity of the debris that was present on the DDS surfaces, and to determine if any of the capsule debris was reaching the chamber walls. In addition, potential enhancement due to gravity in the chamber was evaluated by directly comparing shields fielded in the top and bottom of the chamber. Based on the results, the use of the DDS as debris collectors would be evaluated. The results from both sets were presented to the DDS Working Group. The slides are attached to this document. The 3mm set results are presented first, followed by the results from the IFSA set. In both cases it was determined that a small fraction of the overall debris field was collected on the DDS. This means that the debris that is formed during a NIF shot is condensing out of the plasma and depositing on surfaces closer to the target chamber center, or else it is simply falling to the bottom of the chamber. In either case, it was determined that using the DDS, or fielding a debris collector at the chamber wall, was not feasible for solid debris collection at NIF due to the small amount of debris that had been collected. In addition, since the glass shields suffered quite a bit of damage from particles impacting the surface, glass was ruled out as a collection medium.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Holographic Imaging of Evolving Laser-Plasma Structures

In the 1870s, English photographer Eadweard Muybridge captured motion pictures within one cycle of a horse’s gallop, which settled a hotly debated question of his time by showing that the horse became temporarily airborne. In the 1940s, Manhattan project photographer Berlin Brixner captured a nuclear blast at a million frames per second, and resolved a dispute about the explosion’s shape and speed. In this project, we developed methods to capture detailed motion pictures of evolving, light-velocity objects created by a laser pulse propagating through matter. These objects include electron density waves used to accelerate charged particles, laser-induced refractive index changes used for micromachining, and ionization tracks used for atmospheric chemical analysis, guide star creation and ranging. Our “movies”, like Muybridge’s and Brixner’s, are obtained in one shot, since the laser-created objects of interest are insufficiently repeatable for accurate stroboscopic imaging. Our high-speed photographs have begun to resolve controversies about how laser-created objects form and evolve, questions that previously could be addressed only by intensive computer simulations based on estimated initial conditions. Resolving such questions helps develop better tabletop particle accelerators, atmospheric ranging devices and many other applications of laser-matter interactions. Our photographic methods all begin by splitting one or more “probe” pulses from the laser pulse that creates the light-speed object. A probe illuminates the object and obtains information about its structure without altering it. We developed three single-shot visualization methods that differ in how the probes interact with the object of interest or are recorded. (1) Frequency-Domain Holography (FDH). In FDH, there are 2 probes, like “object” and “reference” beams in conventional holography. Our “object” probe surrounds the light-speed object, like a fleas swarming around a sprinting animal. The object modifies the probe, imprinting information about its structure. Meanwhile, our “reference” probe co-propagates ahead of the object, free of its influence. After the interaction, object and reference combine to record a hologram. For technical reasons, our recording device is a spectrometer (a frequency-measuring device), hence the name “frequency-domain” holography. We read the hologram electronically to obtain a “snapshot” of the object’s average structure as it transits the medium. Our published work shows numerous snapshots of electron density waves (“laser wakes”) in ionized gas (“plasma”), analogous to a water wake behind a boat. Such waves are the basis of tabletop particle accelerators, in which charged particles surf on the light-speed wave, gaining energy. Comparing our snapshots to computer simulations deepens understanding of laser wakes. FDH takes snapshots of objects that are quasi-static --- i.e. like Muybridge’s horse standing still on a treadmill. If the object changes shape, FDH images blur, as when a subject moves while a camera shutter is open. Many laser-generated objects of interest do evolve as they propagate. To overcome this limit of FDH, we developed .... (2) Frequency-Domain Tomography (FDT). In FDT, 5 to 10 probe pulses are fired simultaneously across the object’s path at different angles, like a crossfire of bullets. The object imprints a “streaked” record of its evolution on each probe, which we record as in FDH, then recover a multi-frame “movie” of the object’s evolving structure using algorithms of computerized tomography. When propagation distance exceeds a few millimeters, reconstructed FDT images distort. This is because the lenses that image probes to detector have limited depth of field, like cameras that cannot focus simultaneously on both nearby and distant objects. But some laser-generated objects of interest propagate over meters. For these applications we developed … (3) Multi-Object-Plane Phase-Contrast Imaging (MOP-PCI). In MOP-PCI, we image FDT-like probes to the detector from multiple “object planes” --- like recording an event simultaneously with several cameras, some focused on nearby, others on distant, objects. To increase sensitivity, we exploit a phase-contrast imaging technique developed by Dutch Nobel laureate Fritz Zernike in the 1930s. Using MOP-PCI we recorded single-shot movies of laser pulse tracks through more than 10 cm of air. We plan to record images of meter-long tracks of electron bunches propagating through plasma in an experiment at the Stanford Linear Accelerator Center (SLAC). This will help SLAC scientists understand, optimize and scale small plasma-based particle accelerators that have applications in medicine, industry, materials science and high-energy physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗

Single-shot high-resolution characterization of optical pulses by spectral phase diversity

The concept of spectral phase diversity is proposed and applied to the temporal characterization of optical pulses. The experimental trace is composed of the measured power of a plurality of ancillary optical pulses derived from the pulse under test by adding known amounts of chromatic dispersion. The spectral phase of the pulse under test is retrieved by minimizing the error between the experimental trace and a trace calculated from the optical spectrum using the known diagnostic parameters. An assembly composed of splitters and dispersive delay fibers has been used to generate 64 ancillary pulses whose instantaneous power can be detected in a single shot with a high-bandwidth photodiode and oscilloscope. Pulse-shape reconstruction for pulses shorter than the photodetection impulse response has been demonstrated.The diagnostic is experimentally shown to accurately characterize pulses from a chirped-pulse–amplification system when its stretcher is detuned from the position for optimal recompression. As a result, various investigations of the performance with respect to the number of ancillary pulses and the range of chromatic dispersion generated in the diagnostic are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short-Pulse Photoneutron Production on Beryllium Using the Mercury Pulsed Power X-ray Source

An x-ray beam can produce neutrons using beryllium as a photoneutron converter because of the relatively low 9 Be(ɤ,n) reaction energy threshold. Previous photoneutron production simulations have focused on using a linear accelerator and heavy water to generate photoneutrons for potential medical therapies. This experimental work focused on creating a short, intense neutron pulse using the Mercury pulsed power machine at the U.S. Naval Research Laboratory, which fired a Bremsstrahlung photon beam with an energy endpoint of 4.8 MeV. Several independent detector systems were included in the experiment to measure both the characteristics of the x-ray pulse and resulting photoneutrons. We discovered the neutron pulse follows the time history of the x-ray pulse, enabling neutron pulses as short as 30 ns with less than 10% shot-to-shot variation. The approach offers a high-flux of neutrons with a higher end-point energy than using a heavy water converter. Previous experiments at Mercury have generated fission neutrons using a higher x-ray endpoint and 238 U(n,f). Results indicate that with an optimized diode and beryllium converter target design, neutron production could be further increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗