Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “separatrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The role of B T -dependent flows on W accumulation at the edge of the confined plasma

Abstract Near-separatrix impurity accumulation between the crown and the outer midplane of tokamaks is a common feature in results from codes such as SOLPS-ITER and DIVIMP; however, experimental evidence of accumulation has only recently been obtained and is reported here. The codes find that the poloidal distribution of impurity ions in the scrape-off layer (SOL) depends primarily on toroidal field ( B T )-dependent parallel flow patterns of the background plasma and the parallel ion temperature gradient (∇ ‖ T ion ) force. Experimentally, Mach probes used in L-mode plasmas with favorable (for H-mode access) B T measure fast ( M ∼ 0.3–0.5) inner-target-directed (ITD) background plasma flows at the crown of single-null discharges. This study reports a set of DIVIMP simulations for two similar H-mode discharges from the DIII-D W metal rings campaign differing primarily in B T -direction to assess the effect that fast ITD flows have on the distribution of W ions in the SOL. It is found that for imposed ITD flows of M = 0.3, W ions that otherwise accumulate due to the ∇ ‖ T ion -force are largely flushed out. It is also found that doubling the radial diffusion coefficient from 0.3 to 0.6 m 2 s −1 prevents accumulation due to rapid cross-field transport into the far-SOL, where background plasma flows drain W ions to the divertors. Far-SOL W distributions from DIVIMP are then used to specify input to the impurity transport code 3DLIM, which is used to interpretively model collector probe (CP) deposition patterns measured in the ‘wall-SOL’. It is demonstrated that the deposition patterns are consistent with the DIVIMP predictions of near-SOL accumulation for the unfavorable- B T direction, and little/no accumulation for the favorable- B T direction. The wall-SOL CPs have thus provided the first experimental evidence, albeit indirect, of near-SOL W accumulation—finding it occurs for the unfavorable- B T direction only. For the favorable- B T direction, fast flows can largely prevent accumulation from occurring.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

I-mode pedestal relaxation events in the Alcator C-Mod and ASDEX Upgrade tokamaks

Abstract In some conditions, I-mode plasmas can feature pedestal relaxation events (PREs) that transiently enhance the energy reaching the divertor target plates. To shed light on their appearance, characteristics and energy reaching the divertor targets, a comparative study between two tokamaks — Alcator C-Mod and ASDEX Upgrade — is carried out. It is found that PREs appear only in a subset of I-mode discharges, mainly when the plasma is close to the H-mode transition. Also, a growing oscillating precursor before the PRE onset is observed in the region close to the separatrix in both devices, and a discussion on a possible triggering mechanism is outlined. The PRE relative energy loss from the confined region is found to increase with decreasing pedestal top collisionality ν ped * . Similarly, also the relative electron temperature drop at the pedestal top, which is related to the conductive energy loss, rises with decreasing ν ped * . Based on these relations, the PRE relative energy loss in future devices such as DEMO and ARC is estimated. Finally, the divertor peak energy fluence due to the PRE is measured on each device. Those values are then compared to the model introduced in Eich et al (2017 Nucl. Mater. Energy 12 84–90) for type-I edge localized modes. The model is shown to provide an upper boundary for PRE energy fluence data, while a lower boundary is found by dividing the model by three. These two boundaries are used to make projections of the PRE divertor energy fluence to DEMO and ARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of edge turbulence codes against the TCV-X21 diverted L-mode reference case

Self-consistent full-size turbulent-transport simulations of the divertor and scrape-off-layer (SOL) of existing tokamaks have recently become feasible. This enables the direct comparison of turbulence simulations against experimental measurements. In this work, we perform a series of diverted ohmic L-mode discharges on the tokamak à configuration variable (TCV) tokamak, building a first-of-a-kind dataset for the validation of edge turbulence models. This dataset, referred to as TCV-X21, contains measurements from five diagnostic systems from the outboard midplane (OMP) to the divertor targets—giving a total of 45 one- and two-dimensional comparison observables in two toroidal magnetic field directions. The experimental dataset is used to validate three flux-driven 3D fluid-turbulence models—GBS, GRILLIX and TOKAM3X. With each model, we perform simulations of the TCV-X21 scenario, individually tuning the particle and power source rates to achieve a reasonable match of the upstream separatrix value of density and electron temperature. We find that the simulations match the experimental profiles for most observables at the OMP—both in terms of profile shape and absolute magnitude—while a comparatively poorer agreement is found towards the divertor targets. The match between simulation and experiment is seen to be sensitive to the value of the resistivity, the heat conductivities, the power injection rate and the choice of sheath boundary conditions. Additionally, despite targeting a sheath-limited regime, the discrepancy between simulations and experiment also suggests that the neutral dynamics should be included. The results of this validation show that turbulence models are able to perform simulations of existing devices and achieve reasonable agreement with experimental measurements. Where disagreement is found, the validation helps to identify how the models can be improved. By publicly releasing the experimental dataset and validation analysis, this work should help to guide and accelerate the development of predictive turbulence simulations of the edge and SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of the edge stochastic layer in density pump-out by resonant magnetic perturbations

The role of the edge stochastic layer on particle transport is addressed in DIII-D plasmas with applied resonant magnetic perturbations (RMPs) causing density pump-out (a term used to denote the density reduction at the top of the pedestal due to the applied RMPs). Using an analytical model that adds the stochastic parallel transport of electrons (Harvey et al 1981 Phys. Rev. Lett. 47 102) to the fluid equations, the ambipolar radial electric field and particle flux are calculated simultaneously. In this model the nonambipolar electron particle flux, driven by the stochastic magnetic field, is predominantly balanced by the nonambipolar perpendicular ion flux, driven by toroidal viscosity, across a narrow stochastic layer of order two percent of the plasma radius (0.98 < ψn < 1). The model reproduces the level of density pump-out and its dependence on RMP amplitude near the separatrix for three plasma discharges for which the pedestal foot is at medium to high collisionality $(2\leqslant {\nu }_{\text{sep}}^{\ast }\leqslant 30)$. In this work, the experimentally observed and numerically tested inverse density dependence of density pump-out (Hu et al 2020 Nucl. Fusion 60 076001) is accurately captured by the model: an increase in collisionality with density in the pedestal foot results in a decrease in stochastic diffusivity, and hence a decrease in the level of pump-out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of the boundary heat flux width on core and edge profiles in Alcator C-Mod

This work presents new evidence that the heat flux width, λ q , in the Alcator C-Mod tokamak scales with the edge electron pressure, as observed in the ASDEX Upgrade (AUG) tokamak, but the scaling with volume-averaged pressure, $\bar{p}$, from the plasma stored energy, is a better predictor of λ q in Alcator C-Mod than the edge electron pressure. These previous studies, which find that λ q decreases with increasing plasma pressure, imply that a high performance core at high pressure will lead to challenging heat and particle exhaust due to very small λ q . This concern has led to our significant enlargement of the C-Mod database with the electron density, temperature, and pressure profile data from the Thomson scattering and electron cyclotron emission diagnostics. Using the C-Mod database augmented with new profile data, we find that λ q decreases with increasing edge electron pressure as ${\lambda }_{q}\propto {p}_{\mathrm{e},95}^{-0.26}$, similar to results from AUG, and showing the strength of cross-machine comparisons. We also find that ${\lambda }_{q}\propto {p}_{\mathrm{e},\mathrm{c}\mathrm{o}\mathrm{r}\mathrm{e}}^{-0.56}$, consistent with the original finding from C-Mod that the heat flux width scales as ${\bar{p}}^{-0.48}$. The scalings of λ q with separatrix pressure and gradient scale length are found to match the AUG results qualitatively. The C-Mod scalings with edge plasma quantities have more scatter than the $\bar{p}$ scaling, and, importantly, show different trends for H-modes relative to L- and I-mode. Furthermore, investigating the source of this discrepancy presents an opportunity for further study that may improve our ability to predict the heat flux width in different confinement scenarios in the pursuit of optimizing core-edge performance in future reactors.

Alcator C-Mod↗

Comparison between MAST-U conventional and Super-X configurations through SOLPS-ITER modelling

Abstract MAST-U has recently started operating with a Super-X divertor, designed to increase total flux expansion and neutral trapping, both predicted through simple analytic models and SOLPS calculations to reduce the plasma and impurity density detachment thresholds. In this study, utilising the SOLPS-ITER code, we are quantifying the possible gain allowed by the MAST-U Super-X and neutral baffling geometry, in terms of access to detachment. We show that a significant reduction of the upstream density detachment threshold (up to a factor 1.6) could be achieved in MAST-U, for the Super-X, as opposed to conventional divertor geometry, mainly through an increased total flux expansion, neutral trapping being found very similar between the different configurations. We also show that variations of the strike-point angle are complex to interpret in such a tightly baffled geometry, and that a case in which the target normal points more towards the separatrix does not necessarily imply a lower detachment threshold. As in previous calculations for TCV, we quantify the role of neutral effects through developing and applying a quantitative definition of neutral trapping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of scrape-off layer profiles and turbulence on gas fuelling in high density H-mode regimes in TCV

A set of high density, highly shaped H-mode discharges has been performed in the TCV tokamak with the aim of assessing the effects of increasing divertor neutral recycling on the properties of upstream inter-ELM scrape-off layer (SOL) profiles and transport. An increase of divertor neutral pressure has been correlated with the evolution of separatrix properties and turbulence level. The latter has been quantified by means of the α t parameter introduced in (Eich 2020 Nucl. Fusion 60 056016), describing the contribution of resistive-interchange turbulence in the SOL relative to drift wave transport. The analysis reveals a general broadening of the upstream SOL profiles as α t increases, with the SOL power width measured by the vertical IR thermography system increasing significantly. In a similar way, the upstream density profile widens in the near SOL, whereas in the far SOL a density shoulder is observed to progressively form and increase in amplitude. This behaviour is associated with an enhancement of far SOL turbulent transport in the form of blob-filaments travelling radially faster across the far SOL and becoming bigger at higher α t . Finally, the detected filaments, evaluated from the fast reciprocating probe at the outer midplane, are determined to mostly belong to the resistive ballooning and resistive X-point regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High gas throughput SOLPS-ITER simulations extending the ITER database to strong detachment

Abstract SOLPS-ITER simulations performed for Q DT = 10, P SOL = 100 MW burning plasmas on ITER extend the existing database to high values of separatrix averaged neon impurity concentration (⟨ c Ne ⟩ ≈ 6%) and divertor neutral pressure (⟨ p div ⟩ > 25 Pa) in order to determine the heat flux mitigation capability of these scenarios and whether strongly detached states are accessible. In the existing database of ITER simulations, the level of detachment was limited to cases where the integral ion flux to the outer target was greater than 80% of the value at rollover, with the impurity radiation localized near the target. With the possibility of narrow heat flux channels and increased deposited power due to tile shaping, it is important to explore operation at a higher degree of detachment. Two series of simulations were explored to extend the database of SOLPS simulations. By increasing the deuterium and neon puff rates proportionally, the peak divertor energy flux ( q ⊥,max ) is decreased from 5 to 3 MW m −2 while ⟨ p div ⟩ increased from 11 to 27 Pa. By increasing only the neon puff, q ⊥, max can be reduced to <1MW m −2 while ⟨ p div ⟩ is maintained at ∼ 11 Pa. As the neon puff level is increased, the position of the impurity radiation peak is shifted towards the X-point. At the highest neon puff levels with steady-state solutions, the electron temperature is reduced below 1 eV across 50 cm of each divertor target. The new cases extend previously observed tight relationships in power and momentum loss factors to low electron temperature improving their utility for highly detached regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing high performance RF heating scenarios on the WEST tokamak

High power experiments, up to 9.2 MW with LHCD and ICRH, have been carried out in the full tungsten tokamak WEST. Here, quasi non inductive discharges have been achieved allowing to extend the plasma duration to 53 s with stationary conditions in particular with respect to tungsten contamination. Transitions to H mode are observed, and H-modes lasting up to 4 s have been obtained. The increase in stored energy is weak since the power crossing the separatrix is close to the L–H threshold. Hot L mode plasmas (central temperature exceeding 3 keV) with a confinement time following the ITER L96 scaling law are routinely obtained. The weak aspect ratio dependence of this scaling law is confirmed. Tungsten accumulation is generally not an operational issue on WEST. Difficulty of burning through tungsten can prevent the discharge from accessing to a hot core plasma in the ramp-up phase, or can lead to rapid collapse of the central temperature when radiation is enhanced by a slight decrease of the temperature. Except a few pulses post-boronization, the plasma radiation is rather high (P rad /P tot ~ 50%) and is dominated by tungsten. This fraction does not vary as the RF power is ramped up and is quite similar in ICRH and/or LHCD heated plasmas. An estimate of the contribution of the RF antennas to the plasma contamination in tungsten is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

E × B flow driven electron temperature bifurcation in a closed slot divertor with ion B × ∇ B away from the X-point in the DIII-D tokamak

An electron temperature bifurcation is observed in the small angle slot divertor, which has been developed to enhance neutral cooling across the divertor target by coupling a closed slot structure with appropriate target shaping. Experiments in the DIII-D tokamak and associated SOLPS-ITER modeling with full drifts find a strong interplay between drifts and divertor geometry on divertor dissipation. The coupling of divertor geometry and drift flows can strongly affect the path towards divertor detachment onset as the plasma density is raised. With the strike point on the inner slanted surface and ion B × ∇B away from the magnetic X-point, bifurcative transitions were observed with sharp decrease of T e towards detachment onset both experimentally and computationally. This differs from the situation for the open divertor where the T e cliff was only observed for ion B × ∇B towards the X-point. SOLPS-ITER modeling with full drifts demonstrates that the magnitude of the E × B drift flow is comparable with the main plasma flow. The reversal of both the poloidal and radial E × B flows near the strike point leads to rapid density accumulation right near the separatrix, which results in bifurcative step transition of divertor conditions with cold plasma across the entire divertor target plate. Furthermore, these results indicate that the interplay between geometry and drifts should be fully taken into account in future fusion reactor divertor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD simulation on magnetic compression of field reversed configurations with NIMROD

Abstract Magnetic compression has long been proposed a promising method for plasma heating in a field reversed configuration (FRC). However, it remains a challenge to fully understand the physical mechanisms underlying the compression process, due to its highly dynamic nature beyond the one-dimensional (1D) adiabatic theory model (Spencer et al 1983 Phys. Fluids 26 1564). In this work, magnetohydrodynamics simulations on the magnetic compression of FRCs using the NIMROD code (Sovinec et al 2004 J. Comput. Phys. 195 355) and their comparisons with the 1D theory have been performed. The effects of the assumptions of the theory on the compression process have been explored, and the detailed profiles of the FRC during compression have been investigated. The pressure evolution agrees with the theoretical prediction under various initial conditions. The axial contraction of the FRC can be affected by the initial density profile and the ramping rate of the compression magnetic field, but the theoretical predictions on the FRC’s length in general and the relation r s = 2 r o in particular hold approximately well during the whole compression process, where r s is the major radius of FRC separatrix and r o is that of the magnetic axis. The evolutions of the density and temperature can be affected significantly by the initial equilibrium profile and the ramping rate of the compression magnetic field. During the compression, the major radius of the FRC is another parameter that is susceptible to the ramping rate of the compression field. Basically, for the same magnetic compression ratio, the peak density is higher and the FRC’s radius r s is smaller than the theoretical predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma heating by electron cyclotron wave and the temperature effects on lower hybrid current drive on EAST

This paper presents the progress in the long—pulse operation of the electron cyclotron (EC) system and the achievements in high—electron temperature plasmas by the combined EC and lower hybrid (LH) waves heating since the EC system was built in 2015. An electron temperature of up to 12 keV with a duration over 100 s was realized by the simultaneous heating of EC and LH waves at the line-averaged density ${\bar n_{\text{e}}}$ ~1.8 × 10 19 m –3 . The plasma heating effect strongly depends on the location of EC power deposition. H-mode plasmas with solely EC wave auxiliary heating have been obtained on EAST for the first time. These H-mode discharges show an enhanced confinement factor H 98(y,2) around 1.0, which is higher than the previous H-mode using LH power alone (Xu et al 2011 Nucl. Fusion 51 072001). The total heating power is very close to the threshold value for L–H transition according to the international tokamak scaling. In addition to the temperature effects inside the separatrix, higher electron temperature produced by EC wave is found to reduce the LH power loss in the scrape-off layer due to collisional absorption, which is beneficial to further increase the LH current drive efficiency. Ray-tracing/Fokker–Planck modeling results indicate that higher electron temperature can shorten the LH wave propagation on EAST in a multiple-pass regime, thus decreasing the collisional dissipation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of plasma beta effects on the island divertor transport in the standard configuration of W7-X

The influence of plasma beta effects on the edge plasma transport in the Wendelstein 7-X standard configuration is studied systematically by using EMC3-EIRENE combined with a 3D equilibrium code named HINT. The magnetic topology changes induced by plasma beta effects are significantly reflected in plasma transport behaviors and heat flux patterns on divertor targets. After validating the modeling strategy by comparisons with experimental data, the extended simulations for high performance plasmas show that the threshold separatrix density for accessing the power detachment is reduced in higher beta plasmas. Compared with the vacuum field case, the impurity radiation distributions with finite beta effects are modified in the magnetic island region. The divertor heat flux is distributed more evenly along the toroidal direction on the strike line at the vertical target. The strike line on the horizontal target moves towards the pumping gap with an increase in the plasma beta. In addition, the different pressure profiles with the same central beta also result in a modified heat flux pattern on the divertor targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bifurcation-like transition of divertor conditions induced by X-point radiation in KSTAR L-mode plasmas *

Abstract Density ramps with ion grad B drift directed into lower single null KSTAR L-mode plasmas are associated with a simultaneous and abrupt reduction of the divertor particle flux on both low- and high-field-side targets when the mid-plane line averaged electron density reaches a given level. Target embedded Langmuir probe signals show a clear ‘cliff edge’ behavior similar to that observed in the divertor target electron temperature in DIII-D H-mode plasmas (Eldon et al 2017 Nucl. Fusion 57 066039; McLean et al 2015 J. Nucl. Mater. 463 533–6). The collapse of the particle flux is observed along the whole divertor target area (from private flux region to the far scrape-off layer (SOL)). The critical upstream density of this target flux cliff is invariant under fuel gas throughput modulation. The transition along the cliff occurs in tens of milliseconds. With the cliff, carbon impurities and deuterium neutrals transported through the X-point to the core produce a strong radiation spot near the X-point, seen on bolometric signals, and increase the upstream density. The experimental observations are consistent with time-dependent SOLPS-ITER simulations, which also demonstrate an abrupt transition of the target flux and upstream density with the increase in X-point radiation. The timescale of the cliff predicted by SOLPS-ITER is consistent with the experiment, although, it is influenced by gas throughput or time-dependent numerical methods. In the L-mode phase space of separatrix electron density and temperature, branches are divided based on target temperature, because the latter is strongly coupled to the radiation front and ionization front due to the monotonic characteristic of the parallel electron temperature distribution. Since the H-mode condition operates at a much higher upstream density and electron temperature in phase space, dissipation from sputtered carbon alone leads to the density limit before reaching the X-point radiation condition. This is therefore consistent with the fact that cliffs have never been observed in H-mode KSTAR experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport barrier and spinning blob dynamics in the tokamak edge

Abstract In this work, we investigate the dynamics of plasma blobs in the edge of magnetic confinement devices using a full-f gyrokinetic particle-in-cell code with X-point geometry. In simulations, the evolution of a seeded blob is followed as it approaches a naturally-forming zonal shear layer near the separatrix, where the blob is stabilized by a large spin induced by the self-consistent adiabatic electron response, and blob bifurcation and trapping are observed during the cross-field propagation of blobs. A new theoretical explanation in both the zonal free and zonal shear layer is constructed, where the dominant E × B spin motion is included. A theoretical condition for a transport barrier induced by the interaction between spinning blobs and the zonal shear layer is obtained, and its scaling is verified with simulations. The new theoretical framework, especially the transport barrier, is applicable to explain and predict various experimental phenomena. In particular, the transport barrier condition calculated with experimental parameters demonstrates that the blob radial transport for H mode is smaller than L mode in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and modeling of type-I and type-II ELMs heat flux to the DIII-D divertor

Type-I and type-II edge-localized-modes (ELMs) heat flux profiles measured at the DIII-D divertor feature a peak in the vicinity of the strike-point and a plateau in the scrape-off-layer (SOL), which extends to the first wall. The plateau is present in attached and detached divertors and it is found to originate with plasma bursts upstream in the SOL. The integrated ELM heat flux is distributed at ~65% in the peak and ~35% in this plateau. The parallel loss model, currently used at ITER to predict power loads to the walls, is benchmarked using these results in the primary and secondary divertors with unprecedented constraints using experimental input data for ELM size, radial velocity, energy, electron temperature and density, heat flux footprints and number of filaments. The model can reproduce the experimental near-SOL peak within ~20%, but cannot match the SOL plateau. Employing a two-component approach for the ELM radial velocity, as guided by intermittent data, the full radial heat flux profile can be well matched. The ELM-averaged radial velocity at the separatrix, which explains profile widening, increases from ~0.2 km s –1 in attached to ~0.8 km s –1 in detached scenarios, as the ELM filaments' path becomes electrically disconnected from the sheath at the target. The results presented here indicate filaments fragmentation as a possible mechanism for ELM transport to the far-SOL and provide evidence on the beneficial role of detachment to mitigate ELM flux in the divertor far-SOL. However, these findings imply that wall regions far from the strike points in future machines should be designed to withstand significant heat flux, even for small-ELM regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress towards edge-localized mode suppression via magnetic perturbations in hydrogen plasmas

Abstract The suppression of edge-localized modes (ELMs) by applying resonant magnetic perturbations (RMPs) is well studied in low collisionality deuterium plasmas as a measure to reduce transient divertor heat loads. However, ELM suppression has yet to be demonstrated in non-nuclear fuels such as hydrogen and hydrogen + helium mixtures which are the main ion species to be used in the ITER pre-fusion power operation (PFPO) phase. For the first time, attempts have been made to access ELM suppression with RMPs in ITER-like low collisionality hydrogen plasmas at DIII-D and ASDEX Upgrade. The DIII-D experiments focused on operation with injected power slightly above the L–H power threshold similar to the expected conditions in the ITER PFPO phase with limited external heating power. The RMPs were found to trigger H–L backtransitions, which is shown to be avoided by reducing the L–H power threshold by diluting the plasma with helium. The additional helium combined with a larger measured neutral density of hydrogen inside the separatrix compared to ELM suppressed deuterium plasmas precluded access to a pedestal top density below the known RMP-ELM suppression threshold. At ASDEX Upgrade, RMP-ELM suppression has been achieved when the concentration of 1 H in the hydrogen isotope mix is below 40 % . While all known access criteria for RMP-ELM suppression were met above this threshold, full ELM suppression was replaced by strong mitigation. The most prominent difference between the hydrogen and deuterium plasmas was a change of turbulence characteristics in the pedestal where Doppler reflectometry measurements suggest a significant reduction of turbulence even at small hydrogen concentrations. In conclusion, these experiments not only identify issues that may prevent access to RMP-ELM suppression in the ITER PFPO phase, but also highlight missing physics in our current understanding of RMP-ELM suppression such as potentially the role of turbulence in the pedestal gradient region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of plasma shaping on high density H-mode SOL profiles and fluctuations in TCV

Abstract The impact of plasma shaping on the properties of high density H-mode scrape-off layer (SOL) profiles and transport at the outer midplane has been investigated on Tokamakà configuration variable. The experimental dataset has been acquired by evolving the upper triangularity while keeping the other parameters constant. The scan comprises δ u p values between 0.0 and 0.6, excluding negative triangularity scenarios. Within this study, a transition from type-I edge localised modes to the quasi-continuous exhaust regime takes place from low to high δ u p . The modification of the upstream SOL profiles has been assessed, in terms of separatrix quantities, within the α t turbulence control parameter theoretical framework (Eich et al 2020 Nucl. Fusion 60 056016). The target parallel heat load and the upstream near-SOL density profiles have been shown to broaden significantly for increasing α t . Correspondingly, in the far SOL a density shoulder formation is observed when moving from low to high δ u p . These behaviours have been correlated with an enhancement of the SOL fluctuation level, as registered by wall-mounted Langmuir probes as well as the thermal helium beam diagnostic. Specifically, both the background and the filamentary-induced fluctuating parts of the first wall ion saturation current signal are larger at higher δ u p , with filaments being ejected more frequently into the SOL. Comparison of two pulses at the extremes of the δ u p scan range, but with otherwise same input parameters, shows that the midplane neutral pressure does not change much during the H-mode phase of the discharge. This indicates that indirect effects of the change in geometry, linked to first wall recycling sources, should not play a significant role. The total core radiation increases at high δ u p , on account of a stronger plasma–wall interaction and resulting larger carbon impurity intake from the first wall. This is likely associated to the enhanced first wall fluctuations, as well as a smaller outer gap and the close-to-double-null magnetic topology at high shaping.

Stagni, A. (ORCID:0000000180841544)↗