Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multi-Gas Sensors for Enhanced Reliability of SOFC Operation

GE Research, in partnership with SUNY Polytechnic Institute (SUNY Poly), designed, built, and tested gas sensors for in situ monitoring of H 2 and CO anode tail gases produced with on-site steam reforming in solid oxide fuel cell (SOFC) systems. The knowledge of the H 2 /CO ratio of these anode tail gases should allow accurate determination and control of the efficiency of the reforming process in the SOFC system and should deliver a lower operating cost for SOFC customers. The project objectives were to achieve multi-gas monitoring capability with a single multivariable sensor, and to sustain this performance in the presence of gaseous interferences and a potential poison for the sensor. The duration of the project was 24 months with the project structure that included three technical tasks such as (1) development of design rules of photonic nanostructures for H 2 and CO gas detection, (2) laboratory validation of photonic nanostructures for selective H 2 and CO gas detection, and (3) validation of photonic nanostructures for initial stability and poison-resistance against H 2 S. To build multivariable sensors for selective H 2 and CO gas detection in the presence of interferences, we expanded our earlier knowledge of multi-gas sensors into new fabrication and functionalization methodologies as well as into new methodologies for the spectral data analysis of multi-gas responses. We have advanced our design rules of the three-dimensional (3D) photonic nanostructures that allowed detection of H 2 and CO at high temperatures as individual gases and as their mixtures and rejection of interferences such as CO 2 , H 2 O, CH 4 , and other hydrocarbons for SOFC applications. Our advanced design rules should be attractive for building the new generation of cost-effective industrial sensors. Stability and poison resistance of our 3D photonic nanostructures was tested in the laboratory conditions. While initially we utilized conventional machine learning data analysis tools, we have found that they were unable to correct for the sensor drift. Thus, we have implemented new methods of machine learning for the analysis of our spectral data. These learnings pave the way to move the future studies into advanced testing of effects of interferences, aging and field tests. In future, our work will continue to advance our sensing designs to operate in conditions with known and unknown interferences by implementing nanostructures with enhanced spectral diversity of responses to gaseous species of interest and interferences. Our systematic reduction of technical risks in this completed project and in future studies will ensure transition of this sensing technology to commercialization.

03 NATURAL GAS↗

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗

Chemiresistor sensor based on ion-imprinted polymer (IIP)-functionalized rGO for Cd(II) ions in water

This study reports the design and development of a novel chemiresistor (CR) sensor using ion imprinted polymer (IIP)-functionalized reduced graphene oxide (rGO) [IIP/rGO-CR] for cadmium ions (Cd(II)) determination in water. The sensor consisted of a CR transducer made of rGO channel bridging source and drain electrodes prepared by self-assembly and thermal reduction of graphene oxide (GO) on Au interdigitated electrodes chip fabricated on Si/SiO 2 substrate. The IIP was then grafted on rGO using surface-initiated reversible addition-fragmentation chain transfer (RAFT) polymerization with polyethylenimine (PEI) and methylacrylic acid (MAA) as dual functional monomers and Cd(II) ions as template through UV light-initiated copolymerization. The IIP functionalized on rGO acted as an effective recognition element that modulated the resistance of rGO-CR upon binding of Cd(II), enabling Cd(II) detection at ppb level in aqueous solutions. The prepared IIP/rGO-CR sensor worked effectively in the linear range of 2~200ppb and achieved a limit of detection (LOD) of 0.83 ppb, which is lower than the World Health Organization guidelines of 3ppb for drinking water quality. The developed sensor of IIP/rGO-CR showed a high selectivity against a variety of trace and heavy metal ions found in water and good stability for up to 60 days when stored at room temperature for Cd(II) determination in water. Further, the sensor was successfully applied to analyzing Cd(II) spiked in tap, lake and river waters with a 94.5%–113.5% recovery, demonstrating a high degree of accuracy even in complex water samples. Finally, our results illustrated that the CR sensor of IIP functionalized rGO provides a potential platform for sensitive, robust and low-cost environmental analysis of Cd(II) in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A portable fiber optic sensor for the luminescent sensing of cobalt ions using carbon dots

Cobalt is critical to energy-relevant technologies, and demand for cobalt will increase significantly with growing global adoption of renewables. However, supply chain stability is threatened by economic and geopolitical factors, incentivizing domestic cobalt production from alternative resources such as coal, coal utilization byproducts (e.g., ash, acid mine drainage) and electronic waste. Rapid, inexpensive, and portable characterization techniques are needed to reduce production costs associated with cobalt prospecting and process monitoring. Here, in this research, we develop a compact, portable fiber optic luminescent probe for cobalt using phosphorus and nitrogen co-doped carbon dots as the sensing material. The carbon dot emission overlaps well with the cobalt absorption band at ~510 nm, leading to a selective decrease in emission as a function of cobalt concentration. The system responds nearly instantly to the presence of cobalt, with detection limits of 0.7 and 3.5 ppm in water and pH 1.68 buffer, respectively, providing comparable performance to a commercial spectrometer at a significantly lower cost. Moreover, the sensor is selective for cobalt in the presence of 13 of the most common metal ions encountered in coal utilization byproducts and is responsive to cobalt when spiked into an acid mine drainage leachate sample, highlighting the sensor's potential for real-world deployment in challenging matrices. In addition, integrating the carbon dots with a filter paper substrate produced ‘test strip’ sensors that exhibited a selective and sensitive visual response to cobalt using a handheld UV lamp. Taken together, the sensing system represents a significant step forward in the development of low-cost practical sensors for high-value metals in complex streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exceptional NH 3 Detection by Cu(cyhdc) MOF Sensor Due to H 2 O Coadsorption

Metal–organic framework (MOF)-based electrical impedance sensors are a growing class of sensors that show utility in the detection of environmentally toxic gases. Detection of trace NH 3 has been particularly difficult to design due to the low electrical response of NH 3 . However, this has been circumvented by judiciously selecting a MOF that has enhanced electrical response to NH 3 due to coadsorption with predominant atmospheric gases such as water. Herein, an MOF Cu(cyhdc) based sensor has been successfully demonstrated for the enhanced detection of environmentally toxic NH 3 gas. The sensor shows a change in impedance when it is exposed to 5 ppm of NH 3 . At 20 °C, >30% relative humidity (RH) is necessary to elicit a change, with the response increasing with RH and reaching 3170× at 92% RH, producing the largest published response to NH 3 for a MOF direct electrical sensor. In the absence of water, no change is observed toward 5 ppm of NH 3 over 20–50 °C. Here, this electrical response is largely driven by huge decreases in the imaginary component of the impedance, attributed to increased capacitance at the surface of the MOF crystallites upon NH 3 and H 2 O coadsorption. Complementary structural and microstructural characterization proves that the Cu(cyhdc) crystalline structure and morphology remain intact under trace NH 3 and/or H 2 O adsorption. Despite extremely low NH 3 , loadings seen in TGA, XPS, and FT-IR confirm NH 3 and H 2 O adsorption, and changes to the metal-carboxylate IR peak positions are observed upon NH 3 adsorption. Concentrated primarily at the outer surfaces of the MOF crystallites, this NH 3 and H 2 O coadsorption effectively increases the surface capacitance across the Cu(cyhdc) powder and enables direct electrical detection of trace NH 3 . Together, these results demonstrate how coadsorption of specific molecules (H 2 O) can be used to enable the electrical detection of trace toxic gases that would otherwise not have produced a MOF sensor response.

ammonia↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗

Rational design of a genetically encoded NMR zinc sensor

Elucidating the biochemical roles of the essential metal ion, Zn 2+ , motivates detection strategies that are sensitive, selective, quantitative, and minimally invasive in living systems. Fluorescent probes have identified Zn 2+ in cells but complementary approaches employing nuclear magnetic resonance (NMR) are lacking. Recent studies of maltose binding protein (MBP) using ultrasensitive 129 Xe NMR spectroscopy identified a switchable salt bridge which causes slow xenon exchange and elicits strong hyperpolarized 129 Xe chemical exchange saturation transfer (hyper-CEST) NMR contrast. To engineer the first genetically encoded, NMR-active sensor for Zn 2+ , we converted the MBP salt bridge into a Zn 2+ binding site, while preserving the specific xenon binding cavity. The zinc sensor (ZS) at only 1 μM achieved ‘turn-on’ detection of Zn 2+ with pronounced hyper-CEST contrast. This made it possible to determine different Zn 2+ levels in a biological fluid via hyper-CEST. ZS was responsive to low-micromolar Zn 2+ , only modestly responsive to Cu 2+ , and nonresponsive to other biologically important metal ions, according to hyper-CEST NMR spectroscopy and isothermal titration calorimetry (ITC). Protein X-ray crystallography confirmed the identity of the bound Zn 2+ ion using anomalous scattering: Zn 2+ was coordinated with two histidine side chains and three water molecules. Penta-coordinate Zn 2+ forms a hydrogen-bond-mediated gate that controls the Xe exchange rate. Metal ion binding affinity, 129 Xe NMR chemical shift, and exchange rate are tunable parameters via protein engineering, which highlights the potential to develop proteins as selective metal ion sensors for NMR spectroscopy and imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polymer / single-walled carbon nanotube composite for gas detection

A sensor can include a conductive region in electrical communication with at least two electrodes, the conductive region can include a composite of a polymer and SWCNTs immobilized onto a substrate. In certain embodiment, a linker can be grafted on the substrate. The linker can connect the substrate and the composite of the polymer and SWCNTs. In certain embodiments, the linker can covalently bond the polymer to the substrate. In certain embodiments, metal nanoparticles or ions can be incorporated as a metal sensitizer to confer further selectivity or sensitivity to the device. In certain embodiments, the polymer can act as a ligand for a variety of metal ions. By incorporating a specific metal ion, the sensor can selectively detect a specific analyte. In certain embodiments, the composite of the polymer and SWCNTs can be functionalized. In certain embodiments, the composite can further include a sensing element.

Swager, Timothy Manning↗

Accelerating Discovery to Deployment: Argonne's Materials Engineering Research Facility (MERF) and Its Role in Scaling Materials Technologies for Water and Resource Solutions

The U.S. Department of Energy (DOE) national laboratories represent a unique class of government‐owned, contractor‐operated research institutions dedicated to conducting research and development (R&D) related activities that address national priorities, supporting and advancing the DOE mission. They play a vital role in sustaining U.S. innovation capacity, stewarding the nation's technical base, and nurturing science and technologies. In this perspective, we highlight the processing science and scaleup capabilities of the Materials Engineering Research Facility (MERF) at DOE's Argonne National Laboratory to demonstrate how DOE National Laboratories bridge fundamental science and applied technology development to accelerate deployment. Case studies are presented on selective membranes for critical mineral recovery, sensors for per‐ and polyfluoroalkyl substances (PFAS) detection, surface functionalization via atomic layer deposition (ALD) and sequential infiltration synthesis (SIS), and lithium recovery from battery recycling waste streams using a novel electrodialysis process. These examples underscore MERF's role in translating innovative technologies into practical solutions for renewable water and critical resource recovery, which also leverage Argonne's analytical and computational capabilities. This perspective also outlines mechanisms for collaborating with the DOE national laboratories to strengthen partnerships across government, the national laboratories, academia, and industry.

36 MATERIALS SCIENCE↗

Expediting field-effect transistor chemical sensor design with neuromorphic spiking graph neural networks

Improving the sensitive and selective detection of analytes in a variety of applications requires accelerating the rational design of field-effect transistor (FET) chemical sensors. Achieving high-performance detection relies on identifying optimal probe materials that can effectively interact with target analytes, a process traditionally driven by chemical intuition and time-consuming trial-and-error methods. To address the difficulties in probe screening for FET sensor development, this work presents a methodology that combines neuromorphic machine learning (ML) architectures, specifically a hybrid spiking graph neural network (SGNN), with an enriched dataset of physicochemical properties through semi-automated data extraction using large language models. Achieving a classification accuracy of 0.89 in predicting sensor sensitivity categories, the SGNN model outperformed traditional ML techniques by leveraging its ability to capture both global physicochemical properties and sparse topological features through a hybrid modeling framework. Next-generation sensor design was informed by the actionable insights into the connections between material properties and sensing performance offered by the SGNN framework. Through virtual screening for the detection of per- and polyfluoroalkyl substances (PFAS) as a use case, the effectiveness of the SGNN model was further validated. Density functional theory simulations confirmed graphene as a promising active material for PFAS detection as suggested by the SGNN framework. By bridging gaps in predictive modeling and data availability, this integrated approach provides a strong foundation for accelerating advancements in FET sensor design and innovation.

Ferreira, Rodrigo Pires [Univ. of Chicago, IL (Uni↗

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

Surface water geochemistry along St. Louis River Estuary (Duluth/Superior, MN/WI)

This dataset is aimed at understanding changes in surface water chemistry associated with urbanization in the Great Lakes region. Surface water chemistry including cations, anions, organic and inorganic carbon, and nitrogen were collected from six locations along St. Louis River – a freshwater estuary entering Lake Superior (Duluth/Superior, MN/WI). The Duluth/Superior, MN/WI metropolitan area is the largest port on the United States side of Lake Superior. Samples were collected near different land uses every two weeks from late July 2023 to the onset of ice cover in November 2023. Water samples were analyzed using In-Situ AquaTroll 500 Multiparameter Sonde with Ammonium Ion Selective Electrode and Chlorophyll-a sensor (unfiltered), METTLER TOLEDO FiveEasy Plus FP20 and METTLER TOLEDO LE407 probe (unfiltered); HACH DR300 Pocket Colorimeter Iron FerroVer (filtered 0.22 μm in field); Shimadzu TOC-L Total Organic Carbon Analyzer with TNM-L Total Nitrogen Unit (filtered 0.22 μm in field); Agilent 8900 triple quadrupole ICP-MS (ICP-QQQ) (filtered 0.22 μm in field); and Dionex ICS-6000 HPIC System (filtered 0.22 μm in field).The data package is comprised of 5 files. dd.csv contains the description of columns in Geochemistry_LSNERR_water.csv and Sampling_sites.csv. flmd.csv contains descriptions of each file in the dataset. README.txt contains description of the dataset structure and file content. Geochemistry_LSNERR_water.csv contains geochemistry data for six sampling locations along the St. Louis River. Sampling_sites.csv contains latitude and longitude coordinates for each of the six sampling site locations along the St. Louis River.This data has not been previously published.

54 ENVIRONMENTAL SCIENCES↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanopore device for reversible ion and molecule sensing or migration

Disclosed are methods and devices for detection of ion migration and binding, utilizing a nanopipette adapted for use in an electrochemical sensing circuit. The nanopipette may be functionalized on its interior bore with metal chelators for binding and sensing metal ions or other specific binding molecules such as boronic acid for binding and sensing glucose. Such a functionalized nanopipette is comprised in an electrical sensor that detects when the nanopipette selectively and reversibly binds ions or small molecules. Also disclosed is a nanoreactor, comprising a nanopipette, for controlling precipitation in aqueous solutions by voltage-directed ion migration, wherein ions may be directed out of the interior bore by a repulsing charge in the bore.

47 OTHER INSTRUMENTATION↗

Nanocoral Ag for nonenzymatic glucose detection at extremely low operational potential

Silver (Ag) metal has excellent antibacterial properties, which makes it an ideal candidate for nonenzymatic glucose sensing devices. However, Ag nonenzymatic glucose sensors function at significantly high operating potential and suffer from poor selectivity. Here, we report that nanocoral reduced Ag (R-Ag) based nonenzymatic glucose sensors can be operated at potential as low as 0.1 V vs. Ag/AgCl and exhibits more than one order magnitude higher sensitivity in comparison to the Ag film. The R-Ag sensors can detect glucose in a wide range of concentrations varying from 100 u M to 2.5 mM linearly. Finally, the R-Ag sensors are also very robust, as performance remains unchanged even if sensors are stored under ambient conditions for 45 days.

36 MATERIALS SCIENCE↗

Effect of Ion Irradiation on Amorphous and Crystalline Ge–Se and Their Application as Phase Change Temperature Sensor

Research on phase change materials is predominantly focused on their application as memory devices or for temperature control which requires low phase change temperature. The Ge–Se binary chalcogenide glass system with its wide glass-forming region is a potential candidate for high-temperature and high-radiation phase change applications. In this study, the concept of employing Ge x Se 100– x glasses to monitor high temperature (450–528 °C) using the phase change effect, is reported. Materials selection, device structure, and performance of prototype sensors are analyzed. In addition, the effect of heavy ion irradiation by Xe ions with energies of 200, 600, and 1000 keV (fluence ≈10 14 cm –2 ) on the Ge x Se 100– x ( x = 30, 33, 40) thin films and phase change devices is studied. The irradiation effect on the amorphous and crystalline structure of the thin films is evaluated by Raman spectroscopy and X-ray diffraction (XRD). Although the changes in the structural units of amorphous films are negligible, in crystalline films orthorhombic-GeSe 2 crystals are found to be most affected by irradiation and a new phase, orthorhombic GeSe is found in the thin films after irradiation. The performance of a sensor with an active film of Ge 40 Se 60 is also shown as an example.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and evaluation of a low-cost sensor node for near-background methane measurement

Abstract. We developed a low-cost methane sensing node incorporating two metal oxide (MOx) sensors (Figaro Engineering TGS2611-E00 and TGS2600), humidity and temperature sensing, data storage, and telemetry. We deployed the prototype sensor alongside a reference methane analyzer at two sites: one outdoors and one indoors. We collected data at each site for several months across a range of environmental conditions (particularly temperature and humidity) and methane levels. We explored calibration models to investigate the performance of our system and its suitability for methane background monitoring and enhancement detection, first selecting a linear regression to fit a sensor baseline response and then fitting methane response by the sensor deviation from baseline. We achieved moderate accuracy in a 2 to 10 ppm methane range compared to data from the reference analyzer (RMSE < 0.6 ppm), but we found that the sensor response varied over time, possibly as a result of changes in non-targeted gas concentrations. We suggest that this cross sensitivity may be responsible for mixed results in previous studies. We discuss the implications of our results for the use of these and similar inexpensive MOx sensors for methane monitoring in the 2 to 10 ppm range.

Furuta, Daniel↗