Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scoping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Scoping Study for Fast Flux Testing in the Advanced Test Reactor

The value of fast spectrum reactors remains prominent in the nuclear technology portfolio. The performance of these reactors can be maximized with advancements in nuclear fuel technologies, but development of these technologies is currently held back by lack of fast spectrum test reactors available to the United States. Spectral modification of experiment positions in the thermal spectrum Advanced Test Reactor (ATR) has long been used to support fast reactor fuel development, but these methods have not been progressed to their full potential. This study investigated the use of concentric rings of aluminum-clad fuel plates in ATR flux traps and thermal neutron absorbing filters to increase fast neutron flux on test specimens. This concept was termed the Boosted Energy Advanced Spectrum Test (BEAST). This approach will enable irradiation of advanced fuel designs in prototypic-length fuel pins and representative flux environment to support post irradiation exams, enable transient testing, and produce the type of data that will permit lead test assembly irradiations in true Sodium Fast Reactors (SFRs) when they become available. Neutronic predictions were performed to investigate BEAST design options and thermal hydraulic models were produced to ensure feasibility of BEAST. Two versions were considered based on the geometric limitations of ATR’s small and large flux traps. The small version was found to be preferable due to slightly higher fast flux and fast-to-thermal neutron ratio. Perhaps more influentially, the small flux trap option was also preferred to avoid conflict with ongoing very high temperature reactor fuel irradiation programs in ATR’s large northeast flux trap. The small flux trap option provided less than half the test volume of the large version, but still had adequate volume for seven SFR pins in cross section which could be stacked two-high in ATR’s 1.2m long core to accommodate up to 14 EBR-II size pins. The preference for the small flux trap configuration should be revisited if additional collaborative test programs emerge with the need to irradiate a significant volume of additional specimens. Calculations were performed regarding a lithium deuteride ring to convert thermal neutrons into 14 MeV fusion neutrons. At the time this report was written these calculations were partially complete and it remains to be seen whether the concept would be worth including in BEAST. Given the preference for the small flux trap option, which does not afford enough room for the 14 MeV ring, it was concluded to defer future work on the lithium deuteride ring. This decision could be revisited if fusion material research programs emerge for collaborative testing in BEAST. A cadmium-lined specimen holder design was found to be adequate in filtering thermal neutrons and preferred over other neutron absorbers based on past experience with cadmium baskets. It was acknowledged that cadmium-bearing hardware would become depleted and need to be replaced occasionally, which appeared feasible from a mechanical design perspective. Neutronic studies investigated different enrichment levels in the booster fuel using uranium-molybdenum alloy dispersion fuel which has performed well in past ATR irradiations. Both options were able to drive fuel pins to SFR-like fission heating rates. The high enriched booster fuel option outperformed the low enriched option by ~20% on key metrics including fast flux and fast-to-thermal ratio, but the low enriched option was favored in order to broaden options for potential fuel suppliers. The preferred BEAST design options including cadmium filter with low enriched booster fuel in the small flux trap configuration was predicted to achieve 6.2E14 n/cm2sec fast flux (>0.1 MeV) with a fast-to-thermal ratio of 44.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fluor Solvent Evaluation and Testing New Scope: Techno-economic Assessment of EEMPA Solvent for CO 2 Separations from Natural Gas Combined Cycle Power Plant

In this project, a techno-economic analysis (TEA) and sensitivity studies were conducted to assess the PNNL’s leading water-lean CO 2 capture solvent, EEMPA, for capture CO 2 from a natural gas combined cycle (NGCC) power plant at different levels of capture rate. Process models for the NGCC power plant, integrated with EEMPA carbon capture processes, were developed in Aspen Plus V14 using the most up-to-date property package for EEMPA-H 2 O-CO 2 system. The TEA evaluated EEMPA carbon capture process at normal capture rates (90%, 95% and 97%) against Case B32B (Cansolv) described in NETL Rev4a baseline report, and at higher capture rates aimed at achieving zero or negative emissions from the power plant (400 ppmv, 200 ppmv, and 100 ppmv CO 2 in exhaust gas), compared to typical Direct Air Capture (DAC) technologies. A manuscript was drafted for peer-reviewed publication. The results suggested that the carbon capture cost reaches a minimum of $\$$53.7/tonne CO 2 at 90% capture rate. Compared to Cansolv, one of the industrial benchmarks, EEMPA demonstrates 2-4% cost savings at capture rates up to 95%, but minimal savings at higher capture rate. The water lean-solvent system proves economically attractive for achieving moderate negative emissions (about 200 ppmv CO 2 in exhaust gas, and equivalent to 50% CO 2 removal from air) for NGCC flue gas, with marginal capture costs comparable to direct air capture (DAC) technologies. A sensitivity analysis results reveal that its economic advantage, unaffected by EEMPA price due to low solvent loss and degradation rate. However, the marginal carbon capture cost exceeds $\$$1,000/tonne CO 2 when transitioning from moderate to extreme negative emissions (100 ppmv CO 2 in exhaust gas), suggesting that water-lean solvents may not be economically competitive with other DAC technologies for removing more than 75% CO 2 from air. In addition, initial connection was established with Technology Center Mongstad (TCM) for a potential pilot testing proposal. However, detailed modeling and proposal preparation was not conducted due to the delay of non-disclosure agreement.

20 FOSSIL-FUELED POWER PLANTS↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

Industrial Conduit Hydropower Opportunities in the United States: Scoping Assessment

Industrial conduit hydropower involves generating electricity from flowing water in existing industrial water supply, process flow, or wastewater discharges. The broader range of conduit hydropower involves powering existing water infrastructure in municipal, industrial, or agricultural systems. Whereas municipal and agricultural water systems have been retrofitted somewhat broadly in the United States, there are very few examples of industrial conduit hydropower. As stated in Kao et al. (2022), “conduit hydropower opportunities associated with industrial conduits are the least understood […] industrial developments are likely to be particularly efficient and cost-effective since they are typically eligible for on-site net-metering.” Therefore, additional insight into industrial opportunities is needed.

13 HYDRO ENERGY↗

Simulation of 15% and 50% Thermal Power Dispatch to an Industrial Facility Using a Flexible Generic Full-Scope Pressurized Water Reactor Plant Simulator

Nuclear power plants in the United States are increasingly challenged to compete in wholesale electricity markets due to the low electricity costs and increasingly dynamic grid conditions from competing generation sources. An alternative market for nuclear power is industrial facilities that can use the thermal and/or electrical power generated by a nuclear power plant to offset the economic losses incurred by electricity market challenges. A generic pressurized water reactor (PWR) simulator was used to show the results of a basic design for a generic thermal power extraction system and tests were run using a set of procedures to show what happens when a nuclear power plant transitions from full electrical power dispatch to 15% and 50% thermal power dispatch. This type of operation leads to losses in turbine performance efficiency due to the deviation from the design operating point, but because the thermal power is also used by the industry load without conversion losses, the combined thermal efficiency of the PWR increases. For the 15% case, the thermal efficiency increased from 32% to 41.9%, while for the 50% case, the efficiency increased up to 60.1%. In addition, for 50% thermal power dispatch, the power dissipated by the condenser decreased from approximately 2000 to approximately 1300 MW (thermal), indicating a substantially diminished impact on the environment in terms of releasing heat into the cooling water reservoir.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GHG policy impacts for Seattle’s buildings: targets, timing, and scope

Many US cities are addressing climate change by setting goals to reduce their greenhouse gas (GHG) emissions by a specified amount within a specified time period. In order to achieve these goals, reducing emissions from existing buildings is crucial. Many cities are passing legislation to target existing buildings through benchmarking, auditing, retuning, or energy or emissions performance standards. As cities design legislation, they must consider the timing of the policies, how to prioritize building types and sizes, and how these design decisions will impact the city’s emissions. This paper addresses these questions for one particular US city: Seattle, Washington. A model of Seattle’s building stock was created with benchmarking and tax assessor data. It was then used to predict GHG emissions reductions due to different policy implementations for existing commercial and multifamily buildings. Key findings are: (1) the proposed emissions policy is expected to reduce cumulative emissions from buildings by 19% between 2020 and 2050; (2) delaying the implementation of the policy by five years could limit savings to 12%; and (3) including smaller buildings in the policy could increase savings to 34%. The lessons learned and how this can be used by other cities are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Field Side Launch of Lower Hybrid Waves: A Scoping Study for ADX

Launching lower hybrid (LH) waves from the high field side (HFS) of a tokamak offers significant advantages over low field side (LFS) launch with respect to both wave physics and plasma material interactions (PMI). The higher magnetic field opens the window between wave accessibility and the condition for strong electron Landau damping, allowing LH waves from the HFS to penetrate into the core of a burning plasma, while waves launched from the LFS are restricted to the periphery of the plasma. The lower parallel refractive index (n) of waves launched from the HFS yields a higher current drive efficiency as well. The absence of turbulent heat and particle fluxes on the HFS, particularly in double null configuration, makes it the ideal location to minimize PMI damage to the antenna structure. The quiescent SOL also eliminates the need to couple LH waves across a long distance to the separatrix, as the antenna can be located close to plasma without risking damage to the structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗