Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Drug delivery from hydrophobic-modified mesoporous silicas: Control via modification level and site-selective modification

Dimethylsilyl (DMS) modified mesoporous silicas were successfully prepared via co-condensation and post-grafting modification methods. The post-grafting modification was carried out by the reaction of the as-synthesized MCM-41 material (before CTAB removal) with diethoxydimethylsinale (DEDMS). N{sub 2} adsorption-desorption and {sup 29}Si MAS NMR characterization demonstrated that different amount of DMS groups were successfully incorporated into the co-condensation modified samples, and the functional DMS groups were placed selectively on the pore openings and external pore surfaces in the post-grafting modified samples. Subsequently, the controlled drug delivery properties from the resulting DMS-modified mesoporous silicas were investigated in detail. The drug adsorption experiments showed that the adsorption capacities were mainly depended on the content of silanol group (CSG) in the corresponding carriers. The in vitro tests exhibited that the incorporation of DMS groups greatly retarded the ibuprofen release rate. Moreover, the ibuprofen release profiles could be well modulated by varying DMS modification levels and site-selective distribution of functional groups in mesoporous carriers. - The distribution of DMS groups on the pore surfaces of the mesostructures strongly affects the drug release rate. The P-M41-1 and the P-M41-2 possess the close DMS modification levels as the C-M41-10, but the ibuprofen release rates from the P-M41-1 and P-M41-2 are much slower than that from the C-M41-10.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-T-374: Sensitivity of ArcCHECK to Tomotherapy Delivery Errors: Dependence On Analysis Technique

Purpose: ArcCHECK (Sun Nuclear) is a cylindrical diode array detector allowing three-dimensional sampling of dose, particularly useful in treatment delivery QA of helical tomotherapy. Gamma passing rate is a common method of analyzing results from diode arrays, but is less intuitive in 3D with complex measured dose distributions. This study explores the sensitivity of gamma passing rate to choice of analysis technique in the context of its ability to detect errors introduced into the treatment delivery. Methods: Nine treatment plans were altered to introduce errors in: couch speed, gantry/sonogram synchronization, and leaf open time. Each plan was then delivered to ArcCHECK in each of the following arrangements: “offset,” when the high dose area of the plan is delivered to the side of the phantom so that some diode measurements will be on the order of the prescription dose, and “centered,” when the high dose is in the center of the phantom where an ion chamber measurement may be acquired, but the diode measurements are in the mid to low-dose region at the periphery of the plan. Gamma analysis was performed at 3%/3mm tolerance and both global and local gamma criteria. The threshold of detectability for each error type was calculated as the magnitude at which the gamma passing rate drops below 90%. Results: Global gamma criteria reduced the sensitivity in the offset arrangement (from 2.3% to 4.5%, 8° to 21°, and 3ms to 8ms for couch-speed decrease, gantry-error, and leaf-opening increase, respectively). The centered arrangement detected changes at 3.3%, 5°, and 4ms with smaller variation. Conclusion: Each arrangement has advantages; offsetting allows more sampling of the higher dose region, while centering allows an ion chamber measurement and potentially better use of tools such as 3DVH, at the cost of positioning more of the diodes in the sometimes noisy mid-dose region.

60 APPLIED LIFE SCIENCES↗

Detection of Cometary Amines in Samples Returned by the Stardust Spacecraft

The delivery of amino acids to the early Earth by comets and their fragments could have been a significant source of the early Earth's prebiotic organic inventory that led to the emergence of life (Chyba and Sagan, 1992). Over 20 organic molecules including methane, ethane, ammonia, cyanic acid, formaldehyde, formamide, acetaldehyde, acetonitrile, and methanol have been identified by radio spectroscopic observations of the comae of comets Hale-Bopp and Hyakutake (Crovisier et al. 2004). These simple molecules could have provided the organic reservoir to allow the formation of more complex prebiotic organic compounds such as amino acids. After a 7-year mission, the Stardust spacecraft returned to Earth samples from comet Wild 2 on January 15, 2006 providing the opportunity to analyze the organic composition and isotopic distribution of cometary material with state-of-the-art laboratory instrumentation. The Preliminary Examination Team analyses of organics in samples returned by Stardust were largely focused on particles that impacted the collector aerogel and aluminum foil (Sandford et al. 2006). However, it is also possible that Stardust returned a "diffuse" sample of gas-phase organic molecules that struck the aerogel directly or diffused away from the grains after impact. To test this possibility, samples of Stardust flight aerogel and foil were carried through a hot water extraction and acid hydrolysis procedure to see if primary amine compounds were present in excess of those seen in controls. Here we report highly sensitive liquid chromatography time-of-flight mass spectrometry measurements of amino acids and amines in samples returned from a comet (Glavin et al. 2008). A suite of amino acids and amines including glycine, L-alanine, methylamine (MA), and ethylamine (EA) were identified in the Stardust bulk aerogel. With the exception of MA and EA, all other primary amines detected in comet-exposed aerogels were also present in the aerogel witness tile that was not exposed to Wild 2, suggesting that most amines are terrestrial in origin. However, the enhanced abundances of MA, EA, and possibly glycine in comet-exposed aerogel compared to controls, coupled with MA to EA ratios (1 to 2) that are distinct from preflight aerogels (7 to 10), suggest that these amines were captured from Wild 2. It is possible that MA and EA were formed on energetically processed icy grains containing methane, ethane, and ammonia. The presence of cometary amines in Stardust material supports the hypothesis that comets were an important source of prebiotic organics on the early Earth. To better understand their origin, a systematic compound specific carbon isotopic analysis (C-CSIA) via gas chromatography quadrupole mass spectrometry in with parallel with combustion isotope ratio mass spectrometry (GCQMS/ IRMS) is being conducted. We will discuss our latest C-CSIA measurements and what they indicate about the origin of amino acids extracted from Stardust samples.

Glavin, Daniel P.↗

Detection of Cometary Amines in Samples Returned by the Stardust Spacecraft

The delivery of amino acids to the early Earth by comets and their fragments could have been a significant source of the early Earth's prebiotic organic inventory that led to the emergence of life (Chyba and Sagan, 1992). Over 20 organic molecules including methane, ethane, ammonia, cyanic acid, formaldehyde, formamide, acetaldehyde, acetonitrile, and methanol have been identified by radio spectroscopic observations of the comae of comets Hale-Bopp and Hyakutake (Crovisier et al. 2004). These simple molecules could have provided the organic reservoir to allow the forn1ation of more complex prebiotic organic compounds such as amino acids. After a 7 -year mission, the Stardust spacecraft returned to Earth samples from comet Wild 2 on January 15, 2006 providing the opportunity to analyze the organic composition and isotopic distribution of cometary material with state-of-the-art laboratory instrun1entation. The Preliminary Examination Team analyses of organics in samples returned by Stardust were largely focused on particles that impacted the collector aerogel and aluminum foil (Sandford et al. 2006). However, it is also possible that Stardust returned a "diffuse" sample of gas-phase organic molecules that struck the aerogel directly or diffused away from the grains after impact. To test this possibility, samples of Stardust flight aerogel and foil were carried through a hot water extraction and acid hydrolysis procedure to see if primary amine compounds were present in excess of those seen in controls. Here we report highly sensitive liquid chromatography time-of-flight mass spectron1etry measurements of amino acids and amines in samples returned from a comet (Glavin et al. 2008). A suite of amino acids and amines including glycine, L-alanine, methylamine (MA), and ethylamine (EA) were identified in the Stardust bulk aerogel. With the exception of MA and EA, all other primary amines detected in comet-exposed aerogels were also present in the aerogel witness tile that was not exposed to Wild 2, suggesting that most amines are terrestrial in origin. However, the enhanced abundances of MA, EA, and possibly glycine in comet-exposed aerogel compared to controls, coupled with MA to EA ratios (1 to 2) that are distinct from preflight aerogels (7 to 10), suggest that these amines were captured from Wild 2. It is possible that MA and EA were formed on energetically processed icy grains containing methane, ethane, and ammonia. The presence of cometary amines in Stardust material supports the hypothesis that comets were an important source of pre biotic organics on the early Earth. To better understand their origin, a systematic compound specific carbon isotopic analysis (C-CSIA) via gas chromatography quadrupole mass spectrometry in with parallel with combustion isotope ratio mass spectrometry (GC-QMS/IRMS) is being conducted. We will discuss our latest C-CSIA measurements and what they indicate about the origin of amino acids extracted from Stardust samples.

Glavin, Daniel P.↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Noble Gases in Samples Returned From Asteroids Ryugu and Bennu

Introduction: The asteroid sample return missions, JAXA’s Hayabusa2 [1] and NASA’s OSIRIS-REx [2], fromC-rich asteroids Ryugu and Bennu offer unique opportunities to sample pristine early solar system material, unaffected by terrestrial weathering and contamination, and with a known geological context. The comparison with most primi-tive members of carbonaceous –and inner solar system ordinary and enstatite– chondrite classes allows us to (i) assess the variation (or the lack of thereof) of the distribution of the most volatile elements throughout the entire early solar system, (ii) determine the effects of parent body thermal and aqueous alteration, and (iii) learn about the dynamic evolution and history of the various parent bodies, as sampled by both return missions and meteorite delivery. Here we will present noble gas data obtained from newly received particles from Ryugu and Bennu. Samples & Analysis: We received nine particles allocated by JAXA, with masses of 0.5-1.7 mg mass: four col-lected during Hayabusa2’s first touchdown (chamber A) and five from a small artificial crater (chamber C). We received three particles from Bennu of 0.07, 0.89 and 0.94 mg mass (OREX-800032-102/3/4). All particles were processed, allocated, weighed, and transferred into our UHV sample chamber within pure N2, to prevent any contact with air. We examined all He-Xe isotopes with our custom-built mass spectrometer “Albatros” ([3,4]). Gases were extracted individually from each particle by melting induced by a 1064 μm Nd:YAG IR laser in 2–4 heating steps. Large amounts of water and other reactive volatiles were released, consistent with the presence of abundant volatiles from both Ryugu and Bennu. Residues of Ryugu particles remaining after lasering, subsequently exposed to air, were additionally extracted in a crucible to verify complete gas extraction. Only the particle that still showed a “crystalline” structure after lasering contained detectable Ryugu noble gases, whereas all other particles turned immediately into glassy spheres by laser heating and lacked any gas. Results & Discussion: Ryugu and Bennu matter contains noble gases similar to the most pristine, unheated aqueously altered meteorites, e.g., CM or CI chondrites [5,6]. Remarkably, all four chamber A samples that originated from Ryugu’s surface show solar wind (SW) Ne (trapped (20Ne/22Ne)tr ~12–13), whereas all five chamber C samples do not ((20Ne/22Ne)tr ~9.0–10.7 consistent with the presence of non-solar trapped Ne components such as Q and HL). This demonstrates that JAXA’s sampling strategy succeeded: Chamber C samples analyzed in this work originated from areas shielded from SW, slightly below the surface, that was sampled after the impactor excavated material. The three Bennu particles populate the same range as the Ryugu particles in Ne isotope space with one particle containing SW suggesting that it was part of the uppermost surface layer of Bennu during sampling, while Ne in the smallest sample can be explained best by mixing Ne from presolar diamonds and SiC or graphite, and that in the third one by mixing of, e.g., Q and HL. Using cosmic ray production rates given by [7] yields preliminary exposure ages for Ryugu particles in the same range as determined in [7]. There is, as expected, also no systematic difference between samples from chambers A and C because both sample sets were likely collected within the uppermost layer of Ryugu, which were not shielded from cosmic rays. The concentration of cosmogenic (cos) Ne in the Bennu particle, where Necos was resolvable, is in the same range as found for Ryugu, suggesting roughly similar exposure time to cosmic rays for 5–8 Ma for all particles examined here. The Xe isotopic compositions of all particles are consistent with those of phase Q, with small additions of Xe-HL from presolar diamonds and excess 129Xe* from short-lived 129I decay. The comparably high 129Xe*/129XeQ ratio is similar in all samples, suggesting similar initial I concentrations and closure to Xe loss –or the incorporation of a well-mixed Xe reservoir. The Bennu material was in brief contact with air in the capsule, after atmospheric entry and before storage in pure N2 in a clean room. Both, the –most diagnostic– Xe isotopes and the Ar/Xe vs. Kr/Xe systematics prove that the noble gases are not affected by terrestrial contamination, in contrast to many CI, CY, and CM chondrites found on Earth [5,6], illustrating the importance of sample return. He-Xe concentrations in all particles unaffected bySW are comparable to but at the upper end of ranges reported [5-7]. In accordance with the strong aqueous alteration experienced on the parent bodies of Ryugu and Bennu [1,2], all samples lack the Ar-rich and water-susceptible noble gas components found in less aqueously altered CMs or CRs [e.g., 5,8] and all COs.

Henner Busemann↗

Estimate of the Distribution of Solids Within Mixed Hanford Double-Shell Tank AZ-101: Implications for AY-102

This paper describes the current level of understanding of the suspension of solids in Hanford double-shell waste tanks while being mixed with the baseline configuration of two 300-horsepower mixer pumps. A mixer pump test conducted in Tank AZ-101 during fiscal year 2000 provided the basis for this understanding. Information gaps must be filled to demonstrate the capability of the baseline feed delivery system to effectively mix, sample, and deliver double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microgravity Flight - Accommodating Non-Human Primates

Spacelab Life Sciences-3 (SLS-3) was scheduled to be the first United States man-tended microgravity flight containing Rhesus monkeys. The goal of this flight as in the five untended Russian COSMOS Bion flights and an earlier American Biosatellite flight, was to understand the biomedical and biological effects of a microgravity environment using the non-human primate as human surrogate. The SLS-3/Rhesus Project and COSMOS Primate-BIOS flights all utilized the rhesus monkey Macaca mulatta. The ultimate objective of all flights with an animal surrogate has been to evaluate and understand biological mechanisms at both the system and cellular level, thus enabling rational effective countermeasures for future long duration human activity under microgravity conditions and enabling technical application to correction of common human physiological problems within earth's gravity, e.g., muscle strength and reloading, osteoporosis, immune deficiency diseases. Hardware developed for the SLS-3/Rhesus Project was the result of a joint effort with the French Centre National d'Etudes Spatiales (CNES) and the United States National Aeronautics and Space Administration (NASA) extending over the last decade. The flight hardware design and development required implementation of sufficient automation to insure flight crew and animal bio-isolation and maintenance with minimal impact to crew activities. A variety of hardware of varying functional capabilities was developed to support the scientific objectives of the original 22 combined French and American experiments, along with 5 Russian co-investigations, including musculoskeletal, metabolic, and behavioral studies. Unique elements of the Rhesus Research Facility (RRF) included separation of waste for daily delivery of urine and fecal samples for metabolic studies and a psychomotor test system for behavioral studies along with monitored food measurement. As in untended flights, telemetry measurements would allow monitoring of thermoregulation, muscular, and cardiac responses to weightlessness. In contrast, the five completed Cosmos/Bion flights, lacked the metabolic samples and behavioral task monitoring, but did facilitate studies of the neurovestibular system during several of the flights. The RRF accommodated two adult 8-11 kg rhesus monkeys, while the Russian experiments and hardware were configured for a younger animal in the 44 kg range. Both the American and Russian hardware maintained a controlled environmental system, specifically temperature, humidity, a timed lighting cycle, and had means for providing food and fluids to the animal(s). Crew availability during a Shuttle mission was to be an optimal condition for retrieval and refrigeration of the animal urine samples along with a manual calcein injection which could lead to greater understanding of bone calcium incorporation. A special portable bioisolation glove box was under development to support this aspect of the experiment profile along with the capability of any contingency human intervention. As a result of recent U.S./Russian negotiations, funding for Space Station, and a series of other events, the SLS-3 mission was cancelled and applicable Rhesus Project experiments incorporated into the Russian Bion 11 and 12 missions. A presentation of the RRF and COSMOS/Bion rhesus hardware is presented along with current plans for the hardware.

Dalton, Bonnie P.↗

Microgravity Flight: Accommodating Non-Human Primates

Spacelab Life Sciences-3 (SLS-3) was scheduled to be the first United States man-tended microgravity flight containing Rhesus monkeys. The goal of this flight as in the five untended Russian COSMOS Bion flights and an earlier American Biosatellite flight, was to understand the biomedical and biological effects of a microgravity environment using the non-human primate as human surrogate. The SLS-3/Rhesus Project and COSMOS Primate-BIOS flights all utilized the rhesus monkey, Macaca mulatta. The ultimate objective of all flights with an animal surrogate has been to evaluate and understand biological mechanisms at both the system and cellular level, thus enabling rational effective countermeasures for future long duration human activity under microgravity conditions and enabling technical application to correction of common human physiological problems within earth's gravity, e.g., muscle strength and reloading, osteoporosis, immune deficiency diseases. Hardware developed for the SLS-3/Rhesus Project was the result of a joint effort with the French Centre National d'Etudes Spatiales (CNES) and the United States National Aeronautics and Space Administration (NASA) extending over the last decade. The flight hardware design and development required implementation of sufficient automation to insure flight crew and animal bio-isolation and maintenance with minimal impact to crew activities. A variety of hardware of varying functional capabilities was developed to support the scientific objectives of the original 22 combined French and American experiments, along with 5 Russian co-investigations, including musculoskeletal, metabolic, and behavioral studies. Unique elements of the Rhesus Research Facility (RRF) included separation of waste for daily delivery of urine and fecal samples for metabolic studies and a psychomotor test system for behavioral studies along with monitored food measurement. As in untended flights, telemetry measurements would allow monitoring of thermoregulation, muscular, and cardiac responses to weightlessness. In contrast, the five completed Cosmos/Bion flights, lacked the metabolic samples and behavioral task monitoring, but did facilitate studies of the neurovestibular system during several of the flights. The RRF accommodated two adult 8-11 kg rhesus monkeys, while the Russian experiments and hardware were configured for a younger animal in the 44 kg range. Both the American and Russian hardware maintained a controlled environmental system, specifically temperature, humidity, a timed lighting cycle, and had means for providing food and fluids to the animal(s). Crew availability during a Shuttle mission was to be an optimal condition for retrieval and refrigeration of the animal urine samples along with a manual calcein injection which could lead to greater understanding of bone calcium incorporation. A special portable bioisolation glove box was under development to support this aspect of the experiment profile along with the capability of any contingency human intervention. As a result of recent U.S./Russian negotiations, funding for Space Station, and a series of other events, the SLS-3 mission was cancelled and applicable Rhesus Project experiments incorporated into the Russian Bion 11 and 12 missions. A presentation of the RRF and COSMOS/Bion rhesus hardware is presented along with current plans for the hardware.

Dalton, Bonnie P.↗

Microgravity Flight - Accommodating Non-Human Primates

Spacelab Life Sciences-3 (SLS-3) was scheduled to be the first United States man-tended microgravity flight containing Rhesus monkeys. The goal of this flight as in the five untended Russian COSMOS Bion flights and an earlier American Biosatellite flight, was to understand the biomedical and biological effects of a microgravity environment using the non-human primate as human surrogate. The SLS-3/Rhesus Project and COSMOS Primate-BIOS flights all utilized the rhesus monkey, Macaca mulatta. The ultimate objective of all flights with an animal surrogate has been to evaluate and understand biological mechanisms at both the system and cellular level, thus enabling rational effective countermeasures for future long duration human activity under microgravity conditions and enabling technical application to correction of common human physiological problems within earth's gravity, e.g., muscle strength and reloading, osteoporosis, immune deficiency diseases. Hardware developed for the SLS-3/Rhesus Project was the result of a joint effort with the French Centre National d'Etudes Spatiales (CNES) and the United States National Aeronautics and Space Administration (NASA) extending over the last decade. The flight hardware design and development required implementation of sufficient automation to insure flight crew and animal bio-isolation and maintenance with minimal impact to crew activities. A variety of hardware of varying functional capabilities was developed to support the scientific objectives of the original 22 combined French and American experiments, along with 5 Russian co-investigations, including musculoskeletal, metabolic, and behavioral studies. Unique elements of the Rhesus Research Facility (RRF) included separation of waste for daily delivery of urine and fecal samples for metabolic studies and a psychomotor test system for behavioral studies along with monitored food measurement. As in untended flights, telemetry measurements would allow monitoring of thermoregulation, muscular, and cardiac responses to weightlessness. In contrast, the five completed Cosmos/Bion flights, lacked the metabolic samples and behavioral task monitoring, but did facilitate studies of the neurovestibular system during several of the flights.

Dalton, Bonnie P.↗

Reproducible direct exposure environmental testing of metal-based magnetic media

A flow geometry and flow rate for mixed flowing gas testing is proposed. Use of an impinging jet of humid polluted air can provide a uniform and reproducible exposure of coupons of metal-based magnetic media. Numerical analysis of the fluid flow and mass transfer in such as system has shown that samples confined within a distance equal to the nozzle radius on the surface of impingement are uniformly accessible to pollutants in the impinging gas phase. The critical factor is the nozzle height above the surface of impingement. In particular, the uniformity of exposure is less than plus/minus 2% for a volumetric flow rate of 1600 cm(exp 3)/minute total flow with the following specifications: For a one inch nozzle, the height of the nozzle opening above the stage should be 0.177 inches; for a 2 inch nozzle - 0.390 inches. Not only is the distribution uniform, but one can calculate the maximum delivery rate of pollutants to the samples for comparison with the observed deterioration.

Sides, Paul J.↗

Certifying Acoustic Emission for the Crack Inspection of Integrated Pressure Components

To address the limitations of other nondestructive evaluation (NDE) methods on integrated components due to access constraints, a novel Acoustic Emission (AE) pressure vessel health test was developed in accordance with ASME BPVC.V Article 12. This test was then validated using notched Ti-6Al-4V panels taken to a stress level equivalent to 1.1 times the Maximum Allowable Working Pressure (MAWP) of a flight pressure vessel. The assessment involved utilizing JSC small sample Probability of Detection (POD) calculations, which represents the initial step towards obtaining flight certification for an NDE technique. A robust filtering technique that specifically identifies crack growth was formulated with the assistance of industry partners. This detection method exhibited superior detection ability compared to other NDE methods or microscopy. Within industry, the presence of a group of triangulated energetic crack-like indications typically leads to supplemental inspection or the failure of a tank. The experimental results confirm that this approach, commonly applied to more robust tanks, can be viably extended to integrated aerospace pressure components in scenarios where components can be subjected to pressures up to 1.1 times the MAWP. The testing process encountered delays due to sensor delivery and panel fabrication. Thus far, samples with crack initiators have shown energy levels 10 times higher than blunted controls. This suggests a trend where high individual and total cluster energy could be employed as acceptance criteria. Moreover, the cumulative energy of clusters might serve as a foundation for estimating crack sizes; however, this aspect requires further assessment and localized supplemental inspections are preferred.

certifying↗

STATISTICAL EVALUATION OF SMALL SCALE MIXING DEMONSTRATION SAMPLING AND BATCH TRANSFER PERFORMANCE - 12093

The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste Treatment and Immobilization Plant (WTP) presents a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS) has previously presented the results of mixing performance in two different sizes of small scale DSTs to support scale up estimates of full scale DST mixing performance. Currently, sufficient sampling of DSTs is one of the largest programmatic risks that could prevent timely delivery of high level waste to the WTP. WRPS has performed small scale mixing and sampling demonstrations to study the ability to sufficiently sample the tanks. The statistical evaluation of the demonstration results which lead to the conclusion that the two scales of small DST are behaving similarly and that full scale performance is predictable will be presented. This work is essential to reduce the risk of requiring a new dedicated feed sampling facility and will guide future optimization work to ensure the waste feed delivery mission will be accomplished successfully. This paper will focus on the analytical data collected from mixing, sampling, and batch transfer testing from the small scale mixing demonstration tanks and how those data are being interpreted to begin to understand the relationship between samples taken prior to transfer and samples from the subsequent batches transferred. An overview of the types of data collected and examples of typical raw data will be provided. The paper will then discuss the processing and manipulation of the data which is necessary to begin evaluating sampling and batch transfer performance. This discussion will also include the evaluation of the analytical measurement capability with regard to the simulant material used in the demonstration tests. The paper will conclude with a discussion of the analysis results illustrating the relationship between the pre-transfer samples and the batch transfers, which support the recommendation regarding the need for a dedicated feed sampling facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LabVIEW-based control software for para-hydrogen induced polarization instrumentation

The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10 000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ({sup 13}C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (B{sub o}), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures. Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of {sup 13}C based endogenous contrast agents used in molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formal methods approach to the charging facility location problem for battery electric vehicles

Battery electric vehicles (BEVs) are becoming more prevalent as improvements in battery technology and energy management continue to be made. As the number of electric vehicles grows, the demand for fast-charging stations is expected to increase dramatically. Thus, building new charging station infrastructure efficiently will be key to reducing upfront costs while meeting consumer demands. In this work, we propose a method for choosing a set of charging station locations that are optimized based on a set of given common vehicle demand points. As part of this solution, we also offer a novel abstraction of the road network on which energy-efficient paths that account for charge-time delays may be found. The current algorithm chooses the optimal charging locations for a single agent which has a route objective specified using temporal logic. To demonstrate the proposed method, the running example shows how a charging station could be chosen for an electric delivery vehicle. Simulations were run on sample road networks with a given set of demand points to service and potential charging station locations to compare. The method is shown to successfully rank potential charging stations in terms of their expected average charging time cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Summary Report for the Environmental Protection Agency MERL/FRMAC Mission Alignment Exercise held at the Environmental Protection Agency Facility on June 24-26 2014

From June 24th thru June 26th 2014, members of the Federal Radiological Monitoring and Assessment Center (FRMAC), FRMAC Fly Away Laboratory, and the Environmental Protection Agency (EPA) participated in a joint nuclear incident emergency response/round robin exercise at the EPA facility in Las Vegas, Nevada. The purpose of this exercise was to strengthen the interoperability relationship between the FRMAC Fly Away Laboratory (FAL) and the EPA Mobile Environmental Radiation Laboratory (MERL) stationed in Las Vegas, Nevada. The exercise was designed to allow for immediate delivery of pre-staged, spiked samples to the EPA MERL and the FAL for sample preparation and radiological analysis. Upon completion of laboratory analysis, data was reviewed and submitted back to the FRMAC via an electronic data deliverable (EDD). In order to conduct a laboratory inter-comparison study, samples were then traded between the two laboratories and re-counted. As part of the exercise, an evaluation was conducted to identify gaps and potential areas for improvements for FRMAC, FAL and EPA operations. Additionally, noteworthy practices and potential future areas of interoperability opportunities between the FRMAC, FAL and EPA were acknowledged. The exercise also provided a unique opportunity for FRMAC personnel to observe EPA sample receipt and sample preparation processes and to gain familiarity with the MERL laboratory instrumentation and radiation detection capabilities. The areas for potential improvements and interoperability from this exercise will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA MERL assets.

54 ENVIRONMENTAL SCIENCES↗

Metabolic Cages for a Space Flight Model in the Rat

A variety of space flight models are available to mimic the physiologic changes seen in the rat during weightlessness. The model reported by Wronski and Morey-Holton has been widely used by many investigators, in musculoskeletal physiologic studies especially, resulting in accumulation of an extensive database that enables scientists to mimic space flight effects in the 1-g environment of Earth. However, information on nutrition or gastrointestinal and renal function in this space flight model is limited by the difficulty in acquiring uncontaminated metabolic specimens for analysis. In the Holton system, a traction tape harness is applied to the tail, and the rat's hindquarters are elevated by attaching the harness to a pulley system. Weight-bearing hind limbs are unloaded, and there is a headward fluid shift. The tail-suspended rats are able to move freely about their cages on their forelimbs and tolerate this procedure with minimal signs of stress. The cage used in Holton's model is basically a clear acrylic box set on a plastic grid floor with the pulley and tail harness system attached to the open top of the cage. Food is available from a square food cup recessed into a corner of the floor. In this system, urine, feces, and spilled food fall through the grid floor onto absorbent paper beneath the cage and cannot be separated and recovered quantitatively for analysis in metabolic balance studies. Commercially available metabolic cages are generally cylindrical and have been used with a centrally located suspension apparatus in other space flight models. The large living area, three times as large as most metabolic cages, and the free range of motion unique to Holton's model, essential for musculoskeletal investigations, were sacrificed. Holton's cages can accommodate animals ranging in weight from 70 to 600 g. Although an alternative construction of Holton's cage has been reported, it does not permit collection of separate urine and fecal samples. We describe the modifications to Holton's food delivery system, cage base, and the addition of a separator system for the collection of urine and fecal samples for metabolic and nutrition studies in the tail suspension model.

Harper, Jennifer S.↗

Amino acids in the Martian meteorite Nakhla

A suite of protein and nonprotein amino acids were detected with high-performance liquid chromatography in the water- and acid-soluble components of an interior fragment of the Martian meteorite Nakhla, which fell in Egypt in 1911. Aspartic and glutamic acids, glycine, alanine, beta-alanine, and gamma-amino-n-butyric acid (gamma-ABA) were the most abundant amino acids detected and were found primarily in the 6 M HCl-hydrolyzed, hot water extract. The concentrations ranged from 20 to 330 parts per billion of bulk meteorite. The amino acid distribution in Nakhla, including the D/L ratios (values range from <0.1 to 0.5), is similar to what is found in bacterially degraded organic matter. The amino acids in Nakhla appear to be derived from terrestrial organic matter that infiltrated the meteorite soon after its fall to Earth, although it is possible that some of the amino acids are endogenous to the meteorite. The rapid amino acid contamination of Martian meteorites after direct exposure to the terrestrial environment has important implications for Mars sample-return missions and the curation of the samples from the time of their delivery to Earth.

NASA Discipline Exobiology↗