Preventing Raman Lasing in High-Q WGM Resonators

A generic design has been conceived to suppress the Raman effect in whispering- gallery-mode (WGM) optical resonators that have high values of the resonance quality factor (Q). Although it is possible to exploit the Raman effect (even striving to maximize the Raman gain to obtain Raman lasing), the present innovation is intended to satisfy a need that arises in applications in which the Raman effect inhibits the realization of the full potential of WGM resonators as frequency-selection components. Heretofore, in such applications, it has been necessary to operate high-Q WGM resonators at unattractively low power levels to prevent Raman lasing. (The Raman-lasing thresholds of WGM optical resonators are very low and are approximately proportional to Q(sup -2)). Heretofore, two ways of preventing Raman lasting at high power levels have been known, but both entail significant disadvantages: A resonator can be designed so that the optical field is spread over a relatively large mode volume to bring the power density below the threshold. For any given combination of Q and power level, there is certain mode volume wherein Raman lasing does not start. Unfortunately, a resonator that has a large mode volume also has a high spectral density, which is undesirable in a typical photonic application. A resonator can be cooled to the temperature of liquid helium, where the Raman spectrum is narrower and, therefore, the Raman gain is lower. However, liquid-helium cooling is inconvenient. The present design overcomes these disadvantages, making it possible to operate a low-spectral-density (even a single-mode) WGM resonator at a relatively high power level at room temperature, without risk of Raman lasing.

Savchenkov, Anatoliy↗

Acoustical measurements of vibrational relaxation in moist N2 at elevated temperatures

Sound absorption measurements are conducted by the resonant tube technique to study vibrational relaxation in moist N2 at 301, 343, and 387 K. Analysis of the data shows that improved measurement accuracy at the higher temperatures establishes vibrational-vibrational energy transfer as the operative relaxation path for the de-excitation of N2 by H2O beyond the uncertainty of experimental error. The best-fitted temperature dependence of the vibrational-vibrational rate constant is given, noting that the expression is consistent with seven independent sets of both acoustical and nonacoustical data.

Zuckerwar, A. J.↗

Correction Factor for Determining the London Penetration Depth from Strip Resonators

A significant disagreement is often seen between the theoretical temperature dependent magnetic penetration depth profile and experimentally derived calculations based on stripline type resonators. This short paper shows that the disagreement can be attributed to the susceptance coupled into the resonator from the gap discontinuity as well as the feed line. When the effect is taken into account, the natural resonant frequency of the resonator is increased, and the frequency shift due to kinetic inductance can be calculated much more accurately. While it is necessary to include this effect to determine the penetration depth, it is shown that the impact on unloaded quality factor is generally negligible. The situation when the strip characteristic impedance is not matched to the generator is included.

Romanofsky, Robert R.↗

Lidar measurements using large liquid mirror telescopes

It is a well accepted practice in the discussion of lidars to compare systems by a performance factor given by the product of the transmitter power and receiver aperture. This form of the performance factor reflects the two key parameters that determine the amount of photons recorded from a given range bin; the amount of transmitted photons and the probability of collecting a scattered photon. We are interested in studying the propagation and breaking of gravity waves typically generated in the lower atmosphere. To study these waves requires high temporal and spatial resolution, as they have frequencies as high as 500 mHz and generate turbulent structures with vertical scales of less than 25 m. In the 80 - 100 km region of the atmosphere these measurements are most efficiently obtained by using resonance scattering from sodium atoms deposited by meteors. However, in the 30 - 80 km region, the most efficient scattering arises from molecules (Rayleigh scattering). Since the atmospheric scale height is nominally 7 km, this scattering becomes extremely weak above 60 km. Furthermore, present laser technology limits the power available for Rayleigh-scattering experiments to about 0.5 - 50 W. The transmitter for the lidar system under development at the University of Western Ontario uses a two-beam transmitter to simultaneously measure density perturbations and temperature from both Rayleigh and resonance scattering.

Sica, R. J.↗

Resonance-tube ignition of aluminum

An experimental program was carried out to determine whether spontaneous fluid-dynamic oscillations could create a hazard in gaseous oxygen flow systems by igniting metal contaminants. The particular fluid-dynamic oscillation studied was the resonance-tube phenomenon as it was excited in a tee-shaped configuration representative of configurations found in many industrial flow systems. Pure aluminum was chosen as the candidate material for ignition. The oscillations in the tee-shaped configuration were compared with oscillations driven by choked convergent nozzles and were found to differ markedly. The temperatures generated at the base of the resonance tube were well in excess of 1000 F for both gaseous oxygen and nitrogen. The effect of inert particulate matter introduced into the resonance tube was to increase significantly the measured temperatures. Aluminum in both powder and fiber form was readily ignited within the resonance tube at pressures less than 1200 psia. At higher pressures, the aluminum-oxygen mixture exploded. This investigation confirms the hazardous nature of resonance-tube oscillations as generated in typical piping configurations that use high-pressure oxygen.

Phillips, B. R.↗

Resonance lamp absorption technique for simultaneous determination of the OH concentration and temperature at 10 spatial positions in combustion environments

A rugged, easy to implement, line-of-sight absorption instrument which utilizes a low pressure water vapor microwave discharge cell as the light source, has been developed to make simultaneous measurements of the OH concentration and temperature at 10 spatial positions. The design, theory, and capability of the instrument are discussed. Results of the measurements obtained on a methane/air flat flame burner are compared with those obtained using a single-frequency, tunable dye laser system.

Shirinzadeh, B.↗

Electron-Spin Resonance in Boron Carbide

Samples exhibit Curie-law behavior in temperature range of 2 to 100 K. Technical paper presents studies of electron-spin resonance of samples of hot pressed B9 C, B15 C2, B13 C2, and B4 C. Boron carbide ceramics are refractory solids with high melting temperatures, low thermal conductives, and extreme hardnesses. They show promise as semiconductors at high temperatures and have unusually large figures of merit for use in thermoelectric generators.

Wood, Charles↗

Resonance tube igniter

Reasonance induced in stoichiometric mixtures of gaseous hydrogen-oxygen produces temperatures /over 1100 deg F/ high enough to cause ignition. Resonance tube phenomenon occurs when high pressure gas is forced through sonic or supersonic nozzle into short cavity. Various applications for the phenomenon are discussed.

Conrad, E. W.↗

The shape of the sodium D lines in a high-temperature helium atmosphere

An experiment was performed to measure the shape of the sodium resonance doublet (lambda 5890, lambda 5896) in a high-temperature helium atmosphere. A piston compressor was used to produce temperatures in the range 3000 K to 5500 K. Absorption-line widths and shifts are reported and the widths agree well with calculations.

Eckart, M. J.↗

Investigations of High Pressure Acoustic Waves in Resonators with Seal-like Features

A conical resonator (having a dissonant acoustic design) was tested in four configurations: (1) baseline resonator with closed ends and no blockage, (2) closed resonator with internal blockage, (3) ventilated resonator with no blockage, and (4) ventilated resonator with an applied pressure differential. These tests were conducted to investigate the effects of blockage and ventilation holes on dynamic pressurization. Additionally, the investigation was to determine the ability of acoustic pressurization to impede flow through the resonator. In each of the configurations studied, the entire resonator was oscillated at the gas resonant frequency while dynamic pressure, static pressure, and temperature of the fluid were measured. In the final configuration, flow through the resonator was recorded for three oscillation conditions. Ambient condition air was used as the working fluid.

Daniels, Christopher↗

Nonlinear Oscillations and Flow of Gas Within Closed and Open Conical Resonators

A dissonant acoustic resonator with a conical shaped cavity was tested in four configurations: (A) baseline resonator with closed ends and no blockage; (B) closed resonator with internal blockage; (C) ventilated resonator with no blockage; and (D) ventilated resonator with an applied pressure differential. These tests were conducted to investigate the effects of blockage and ventilation holes on dynamic pressurization. Additionally, the investigation was to determine the ability of acoustic pressurization to impede flow through the resonator. In each of the configurations studied, the entire resonator was oscillated at the gas resonant frequency while dynamic pressure, static pressure, and temperature of the fluid were measured. In the final configuration, flow through the resonator was recorded for three oscillation conditions. Ambient condition air was used as the working fluid. The baseline results showed a marked reduction in the amplitude of the dynamic pressure waveforms over previously published studies due to the use of air instead of refrigerant as the working fluid. A change in the resonant frequency was recorded when blockages of differing geometries were used in the closed resonator, while acoustic pressure amplitudes were reduced from baseline measurements. A sharp reduction in the amplitude of the acoustic pressure waves was expected and recorded when ventilation ports were added. With elevated pressure applied to one end of the resonator, flow was reduced by oscillating the cavity at the fluid fundamental resonant frequency compared to cases without oscillation and oscillation off-resonance.

Daniels, Christopher↗

Improving the Optical Quality Factor of the WGM Resonator

Resonators usually are characterized with two partially dependent values: finesse (F) and quality factor (Q). The finesse of an empty Fabry-Perot (FP) resonator is defined solely by the quality of its mirrors and is calculated as F=piR(exp 1/2)/(1-R). The maximum up-to-date value of reflectivity R approximately equal to 1 - 1.6 x 10(exp -6) is achieved with dielectric mirrors. An FP resonator made with the mirrors has finesse F=1.9 x 10(exp 6). Further practical increase of the finesse of FP resonators is problematic because of the absorption and the scattering of light in the mirror material through fundamental limit on the reflection losses given by the internal material losses and by thermodynamic density fluctuations on the order of parts in 109. The quality factor of a resonator depends on both its finesse and its geometrical size. A one-dimensional FP resonator has Q=2 F L/lambda, where L is the distance between the mirrors and lambda is the wavelength. It is easy to see that the quality factor of the resonator is unlimited because L is unlimited. F and Q are equally important. In some cases, finesse is technically more valuable than the quality factor. For instance, buildup of the optical power inside the resonator, as well as the Purcell factor, is proportional to finesse. Sometimes, however, the quality factor is more valuable. For example, inverse threshold power of intracavity hyperparametric oscillation is proportional to Q(exp 2) and efficiency of parametric frequency mixing is proportional to Q(exp 3). Therefore, it is important to know both the maximally achievable finesse and quality factor values of a resonator. Whispering gallery mode (WGM) resonators are capable of achieving larger finesse compared to FP resonators. For instance, fused silica resonators with finesse 2.3 x 10(exp 6) and 2.8 x 10(exp 6) have been demonstrated. Crystalline WGM resonators reveal even larger finesse values, F=6.3 x 10(exp 6), because of low attenuation of light in the transparent optical crystals. The larger values of F and Q result in the enhancement of various nonlinear processes. Low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations based on these resonators have been recently demonstrated. Theory predicts a possibility of nearly 10(exp 14) room-temperature optical Q-factors of optical crystalline WGM resonators, which correspond to finesse levels higher than 10(exp 9). Experiments have shown numbers a thousand times lower than that. The difference occurs due to media imperfections. To substantially reduce the optical losses caused by the imperfections, a specific, multi-step, asymptotic processing of the resonator is implemented. The technique has been initially developed to reduce microwave absorption in dielectric resonators. One step of the process consists of mechanical polishing performed after high temperature annealing. Several steps repeat one after another to lead to significant reduction in optical attenuation and, as a result, to the increase of Q-factor as well as finesse of the resonator which demonstrates a CaF2 WGM resonator with F greater than 10(exp 7) and Q greater than 10(exp 11).

Savchenkov, Anatoliy↗

On the magnon interaction in Haematite. 2: Magnon energy of the acoustical mode and magnetic critical fields

Previous spin wave theories of the antiferromagnet hematite were extended. The behavior of thermodynamic quantities around the Morin transition temperature was studied, and the latent heat of the Morin transition was calculated. The temperature dependence of the antiferromagnetic resonance frequency and the parallel and perpendicular critical spin-flop magnetic fields were calculated. It was found that the theory agrees well with experiment.

Bonavito, N. L.↗

ENDOR and ESR studies of a stable radical in irradiated cytidine

A model is proposed for a stable radical species formed by X-irradiation in a single crystal of cytidine and studied by electron nuclear double resonance (ENDOR) and electron spin resonance (ESR) techniques at room temperature. ENDOR and ESR spectra are analyzed to obtain the principal values of the spectroscopic splitting factor and the spectroscopic and hyperfine splitting tensors. The results show hyperfine coupling of an unpaired electron to one hydrogen nucleus and two slightly different geometric forms of the radical with small differences in hyperfine couplings. It is proposed that this radical is formed in the ribose sugar group with a hydrogen atom in a beta position coupling with respect to a carbon-centered unpaired electron and a spin density of approximately 0.2 on a carbon atom.

Allison, D. L.↗