Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reflectometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Continuous liquid level measurements with time-domain reflectometry

Description of the basic principles of radar measurements of cryogenic liquid levels in storage vessels by time-domain reflectometry. The probe consists of a right circular coaxial transmission line positioned vertically in the storage vessel and having holes drilled in the outer conductor to permit penetration of the liquid into the annular gap. RF pulses transmitted through the probe are reflected at liquid/gas interface and returned for sampling at the input. The measured delay of the return pulse is displayed as the level of liquid in the vessel.

Cruz, J. E.↗

Nondestructive evaluation of composites by optical time domain reflectometry

Results in the measurement of slowly varying mechanical loading functions on composites using optical time domain reflectometry (OTDR) in imbedded optical fiber during both simulated manufacture and use are reviewed. First, the basic theoretical and experimental principles of the OTDR system are described. Next, the mechanical system of the composite and the imbedded fiber is analyzed. Results of measurement obtained for various loading functions applied to material specimens are then described and system limitations on spatial resolution, strain amplitude sensitivity, and frequency response are explained in terms of the range and resolution limits of the OTDR system.

Claus, R. O.↗

Nondestructive evaluation of composites by optical time domain reflectometry in imbedded optical fibers

The use of imbedded optical fibers to obtain dynamic two-dimensional dynamic-strain measurements by optical time-domain reflectometry (OTDR) in laminated composites is described. The fundamental principles of OTDR are reviewed, and the basic parameters resolution and dynamic range are defined. Results of OTDR measurements on 30-cm square plates of 0/90/90/0-deg graphite epoxy composite with type 1506 optical fibers imbedded in a serpentine pattern between (and parallel to the reinforcing fibers of) the 90-deg plates are presented in graphs and briefly characterized. It is estimated that processing the OTDR data with simple techniques could permit strain detection of the order 0.00001 at sampling rates as high as 1/ms.

Claus, R. O.↗

Time domain reflectometry in time variant plasmas

The effects of time-dependent electron density fluctuations on a synthesized time domain reflectometry response of a one-dimensional cold plasma sheath are considered. Numerical solutions of the Helmholtz wave equation, which describes the electric field of a normally incident plane wave in a specified static electron density profile, are used. A study of the effects of Doppler shifts resulting from moving density fluctuations in the electron density profile of the sheath is included. Varying electron density levels corrupt time domain and distance measurements. Reducing or modulating the electron density levels of a given electron density profile affects the time domain response of a plasma and results in motion of the turning point, and the effective motion has a significant effect on measuring electron density locations.

Scherner, Michael J.↗

Measurement of shear-wave velocity by ultrasound critical-angle reflectometry (UCR)

There exists a growing body of research that relates the measurement of pressure-wave velocity in bone to different physiological conditions and treatment modalities. The shear-wave velocity has been less studied, although it is necessary for a more complete understanding of the mechanical properties of bone. Ultrasound critical-angle reflectometry (UCR) is a noninvasive and nondestructive technique previously used to measure pressure-wave velocities both in vitro and in vivo. This note describes its application to the measurement of shear-wave velocity in bone, whether directly accessible or covered by soft tissue.

NASA Discipline Cardiopulmonary↗

Shielded-Twisted-Pair Cable Model for Chafe Fault Detection via Time-Domain Reflectometry

This report details the development, verification, and validation of an innovative physics-based model of electrical signal propagation through shielded-twisted-pair cable, which is commonly found on aircraft and offers an ideal proving ground for detection of small holes in a shield well before catastrophic damage occurs. The accuracy of this model is verified through numerical electromagnetic simulations using a commercially available software tool. The model is shown to be representative of more realistic (analytically intractable) cable configurations as well. A probabilistic framework is developed for validating the model accuracy with reflectometry data obtained from real aircraft-grade cables chafed in the laboratory.

Schuet, Stefan R.↗

Carbon Fiber TOW Angle Determination Using Microwave Reflectometry

NASA's Advanced Composites Project is investigating technologies that increase automated remote inspection of aircraft composite structures. Therefore, microwave Frequency Domain Reflectometry (FDR) is being investigated as a method of enabling rapid remote inspection of angular orientation of the tow using microwave radiation. This work will present preliminary data demonstrating that frequency shifts in the reflection spectrum of a carbon fiber tow sample are indicative of the angle of the tow with respect to an interrogating antenna's linear polarized output.

Wilson, William C.↗

The Rise of GNSS Reflectometry for Earth Remote Sensing

The Global Navigation Satellite System (GNSS) reflectometry, i.e. GNSS-R, is a novel remote-sensing technique first published in that uses GNSS signals reflected from the Earth's surface to infer its surface properties such as sea surface height (SSH), ocean winds, sea-ice coverage, vegetation, wetlands and soil moisture, to name a few. This communication discusses the scientific value of GNSS-R to (a) furthering our understanding of ocean mesoscale circulation toward scales finer than those that existing nadir altimeters can resolve, and (b) mapping vegetated wetlands, an emerging application that might open up new avenues to map and monitor the planet's wetlands for methane emission assessments. Such applications are expected to be demonstrated by the availability of data from GEROS-ISS, an ESA experiment currently in phase A, and CyGNSS [3], a NASA mission currently in development. In particular, the paper details the expected error characteristics and the role of filtering played in the assimilation of these data to reduce the altimetric error (when averaging many measurements).

wetland mapping↗

Snow Accumulation Variability on a West Antarctic Ice Stream Observed with GPS Reflectometry, 2007-2017

Land ice loss from Antarctica is a significant and accelerating contribution to global sea level rise; however, Antarctic mass balance estimates are complicated by insufficient knowledge of surface mass balance processes such as snow accumulation. Snow accumulation is challenging to observe on a continental scale and in situ data are sparse, so we largely rely on estimates from atmospheric models. Here we employ a novel technique, GPS interferometric reflectometry (GPS-IR), to measure upper (less than 2 m) firn column thickness changes across a 23-station GPS array in West Antarctica. We compare the results with antenna heights measured in situ to establish the method's daily uncertainty (0.06 m) and with output from two atmospheric reanalysis products to categorize spatial and temporal variability of net snow accumulation. GPS-IR is an effective technique for monitoring surface mass balance processes that can be applied to both historic GPS data sets and future experiments to provide critical in situ observations of processes driving surface height evolution.

snow↗

Development of Spaceborne SoOp Reflectometry Model for Complex Terrains

Following the launch of multiple global navigation satel-lite system (GNSS) reflectometry (GNSS-R) missions, theSignals of Opportunity (SoOp) method has proven to be apowerful tool for geophysical parameter retrieval for land ap-plications such as soil moisture. Having demonstrated thefeasibility of the SoOp techniques at P- and S-band, the devel-opment of SoOp measurements beyond the GNSS frequencyregime is highly anticipated. The SoOp Coherent Bistatic(SCoBi) model and simulator, developed in 2017 and open-sourced in 2018, has been made available to provide multi-frequency, fully polarimetric SoOp simulations for ground-based applications through the joint use of analytical wavetheory and distorted Borne approximation to evaluate landcontributions from multilayer dielectric profiles composed ofsoil moisture, vegetation, and surface roughness effects. Thispaper describes the advancement of SCoBi from a ground-and airborne-based model to a spaceborne model. This ex-tension allows for fully polarimetric, complex delay-Dopplermap (DDM) simulations through evaluation of the coherentsuperposition of electric fields emerging from a grid of ori-ented facets. The model generates a grid of facets by de-termining the geometry of contributing elements from digitalelevation models, with each element providing its contribu-tion under a flat-earth assumption. This module will enablethe analysis of fully polarimetric scattering from frequenciesavailable across the ultra-high frequency (UHF) regime.

D R Boyd↗

Neutron Reflectometry and QCM-D Study of the Interaction of Cellulase Enzymes with Films of Amorphous Cellulose

Improving the efficiency of enzymatic hydrolysis of cellulose is one of the key technological hurdles to reduce the cost of producing ethanol and other transportation fuels from lignocellulosic material. A better understanding of how soluble enzymes interact with insoluble cellulose will aid in the design of more efficient enzyme systems. We report a study involving neutron reflectometry (NR) and quartz crystal microbalance with dissipation (QCM-D) of the interaction of a commercial fungal enzyme extract (T. viride), two purified endoglucanses from thermophilic bacteria (Cel9A from A. acidocaldarius and Cel5A from T. maritima), and a mesophilic fungal endoglucanase (Cel45A from H. insolens) with amorphous cellulose films. The use of amorphous cellulose is motivated by the promise of ionic liquid pretreatment as a second generation technology that disrupts the native crystalline structure of cellulose. NR reveals the profile of water through the film at nm resolution, while QCM-D provides changes in mass and film stiffness. At 20 oC and 0.3 mg/ml, the T. viride cocktail rapidly digested the entire film, beginning from the surface followed by activity throughout the bulk of the film. For similar conditions, Cel9A and Cel5A were active for only a short period of time and only at the surface of the film, with Cel9A releasing 40 from the ~ 700 film and Cel5A resulting in only a slight roughening/swelling effect at the surface. Subsequent elevation of the temperature to the Topt in each case resulted in a very limited increase in activity, corresponding to the loss of an additional 60 from the film for Cel9A and 20 from the film for Cel5A, and very weak penetration into and digestion within the bulk of the film, before the activity again ceased. The results for Cel9A and Cel5A contrast sharply with results for Cel45A where very rapid and extensive penetration and digestion within the bulk of the film was observed at 20 C. We speculate that the large differences are due to the use of the thermophilic enzymes far below their optimal temperatures and also the presence of a cellulose binding module (CBM) on Cel45A while the thermophilic enzymes lack a CBM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Chemical Speciation in Ultra Thin Uranium Oxide Films by Neutron Reflectometry

Motivation for this project is due to more than 17 kg of HEU and 400 g of Pu have been interdicted through an international effort to control nuclear smuggling. Nuclear forensics - Detection and analysis of nuclear materials recovered from either the capture of unused materials or from the radioactive debris following a nuclear explosion or activities, which can contribute significantly for national security. Develop new nuclear forensic methods can be applied to: (a) Environmental swipes, (b) Small particulates, and (c) Thin films. Conclusions of the project are: (1) A unique approach: Neutron Reflectometry + Surface Enhanced Raman Spectroscopy; and (2) Detection of chemical speciation with {angstrom}-level resolution.

36 MATERIALS SCIENCE↗

Active Time Domain Reflectometry for Tamper Indication in Unattended Safeguards Systems

The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-cost commercially available spread-spectrum TDR technology as one option for field implementation. This paper describes the TDR methods under investigation and the associated benchtop test-bed, tampering scenarios of interest,, and viability measurement results to date (e.g., comparison of relative sensitivity to tamper scenarios).

Sheen, David M.↗

Apparatuses and methods for optical code-delay reflectometry (OcoDR)

Apparatuses and methods for optical code-delay reflectometry (OCoDR) are disclosed. An apparatus includes a modulator, a receiver, and control circuitry. The modulator is configured to receive incident electromagnetic (EM) radiation at a substantially fixed frequency generated by one or more EM radiation sources. The incident EM radiation includes continuous-wave EM radiation. The modulator is configured to impart a sequence onto an amplitude, a phase, or both of the incident EM radiation to generate modulated EM radiation. The modulated EM radiation includes continuous-wave EM radiation. The receiver is configured to receive reference EM radiation. The receiver is also configured to receive reflected EM radiation from an optical system responsive to the modulated EM radiation and generate interfered EM radiation responsive to the reference EM radiation and the reflected EM radiation. The receiver is further configured to generate a continuous interferogram responsive to the interfered EM radiation.

Seeley, Ryan↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Effect of Semiconducting Layer on Cable Insulation Damage Detection Using Surface Wave Reflectometry

This paper presents a study of the effect of the semiconducting layer present in medium and high voltage cables on surface wave propagation and its feasibility in detecting insulation damage on cables. Simulation studies were conducted using Ansys High Frequency Structure Simulator (HFSS). It was observed that attenuation increased with thicker semiconducting layer and higher conductivity of the layer. For instance, on a 24.4 mm diameter power cable, the electric field strength associated with a 1 GHz surface wave declines with distance and fades away after 30 m when a 2 mm thick semiconducting layer is present. More results as a function of semiconducting layer thickness, material conductivity and permittivity, distance of a damaged section, etc. will be presented.

reflectometry, unshielded power cable, semiconduct↗