Examining the Ability of an FSO Receiver to Simultaneously Communicate with Multiple Transmitters

FSO (Free-Space Optical)-based communication systems experience difficulty with receiving and separating signals arising from multiple transmitters, a capability that would facilitate implementation of MIMO (Multiple-In, Multiple-Out) systems. Current implementations require multiple, distinct optical antennas, each tracking a single user, which proves bulky and costly, especially if the transmitters are moving and must be tracked. A fiber-bundle receiver has the potential to use multiple pathways, corresponding to the individual fibers within the receiver, to capture different combinations of the incoming optical signals. If the bundle provides linear combining of the optical signals from both the individual fibers in the bundle and amongst the incoming optical signals, signal processing could extract the individual signals from the combinations. In this paper, we experimentally investigate whether the fiber-bundle receiver possesses sufficient linearity of operation to allow the separation of two signals by simple processing algorithms, for both turbulent and non-turbulent conditions. Data from two distinct sources enters a single-bundle, single field of view receiver, and a basis signal from one transmitter provides the reference for performing simple subtraction-based extraction of the unknown signal from the other transmitter. The experimental results show that the receiver does operate linearly, and that the linear operation remains sufficiently intact in the presence of turbulence to extract a recognizable copy of one signal from the other. The ability of the fiber bundle receiver to mitigate turbulence effects appears to assist in maintaining this sufficient level of linearity.

Fibers↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Suction-recirculation device for stabilizing particle flows within a solar powered solid particle receiver

A suction-recirculation device for stabilizing the flow of a curtain of blackened heat absorption particles falling inside of a solar receiver with an open aperture. The curtain of particles absorbs the concentrated heat from a solar mirror array reflected up to the receiver on a solar power tower. External winds entering the receiver at an oblique angle can destabilize the particle curtain and eject particles. A fan and ductwork is located behind the back wall of the receiver and sucks air out through an array of small holes in the back wall. Any entrained particles are separated out by a conventional cyclone device. Then, the air is recirculated back to the top of the receiver by injecting the recycled air through an array of small holes in the receiver's ceiling and upper aperture front wall. Since internal air is recirculated, heat losses are minimized and high receiver efficiency is maintained. Suction-recirculation velocities in the range of 1-5 m/s are sufficient to stabilize the particle curtain against external wind speeds in excess of 10 m/s.

47 OTHER INSTRUMENTATION↗

Falling particle solar receivers

Falling particle solar receivers, systems, and methods are disclosed that include one non-linear falling particle curtain or two or more falling particle curtains within a solar receiver that receives incident solar radiation. The particles heated in the solar receiver may be used to heat a secondary fluid. In an embodiment, the particles may be recirculated to improve energy capture and thermal efficiency. In other embodiments, an air curtain may be used across the aperture of the receiver, and flow-control devices may be used to evenly spread particles across the width of the receiver inlet. Finally, feed particles may be preheated using heat from the solar receiver.

14 SOLAR ENERGY↗

Falling particle solar receivers

Falling particle solar receivers, systems, and methods are disclosed that include one non-linear falling particle curtain or two or more falling particle curtains within a solar receiver that receives incident solar radiation. The particles heated in the solar receiver may be used to heat a secondary fluid. In an embodiment, the particles may be recirculated to improve energy capture and thermal efficiency. In other embodiments, an air curtain may be used across the aperture of the receiver, and flow-control devices may be used to evenly spread particles across the width of the receiver inlet. Finally, feed particles may be preheated using heat from the solar receiver.

Ho, Clifford K.↗

On-Sun Characterization of Microchannel Supercritical Carbon Dioxide Solar Thermal Receivers - Preliminary Findings

The design of, and preliminary on-sun tests on, an 8 cm x 8 cm microchannel supercritical carbon dioxide (sCO2) receiver is presented. The receiver has a laminated design, wherein sheets of Haynes 230 nickel superalloy are patterned and diffusion bonded to form microscale flow passages. The microscale pattern is in the form of square pins with width and height of 500 μm and 200 μm respectively. The pins are arranged in an in-line pattern with respect to the flow direction. The longitudinal and transverse pitch ratios of the micro pin fins are identical and equal to two times the side width of the pillar. A sCO2 test facility is developed with the ability to supply sCO2 at 200 bar pressure and at temperatures between 300-500°C to the receiver inlet. The sCO2 facility is coupled to a seven meter diameter parabolic dish with a 25 kW rating and a concentration ratio of about 800. On-sun tests are performed at a receiver inlet pressure of 150 bar and a receiver inlet temperature between 110-130°C. Receiver and thermal efficiencies in excess of 0.91 and 0.96 respectively for the incident heat flux ranging from 8 to 80 W/cm2, and average surface temperatures ranging from 150-550°C are obtained in these experiments.

14 SOLAR ENERGY↗

Design, Fabrication and On-Sun Performance Evaluation of SiC Receiver Feature Specimens for CST Applications Using Additively Manufactured SiC Materials

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Successful development of CST systems to generate heat for industrial applications requires significant increase in temperature capability and techno-economically viability of the receiver systems. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Aerospace Research in collaboration with Heliogen Holdings Inc and Sandia National Lab, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to demonstrate SiC receiver with air exit temperatures up to 1100 oC and high thermal efficiencies. We report design, fabrication and on-sun test results of SiC components of a prototype 50kW (thermal) HOTSSTAR module. The receiver module architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around a SiC center absorber. The SiC components are fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the reliability and to minimize the risk of cracking damage of SiC test articles in thermal gradient and thermal shock environment of the application, the components were laminated with GE’s MI SiC-SiC CMC. Following extensive design and lab test analyses, selected SiC component designs are tested at Heliogen Lancaster Solar field under highly concentrated solar fluxes around 2000 suns to assess the thermal performance characteristics under realistic field conditions. We report on the test results and compare the thermal performances of different HOTSSTAR SiC absorbers. Finally, we discuss fabrication and initial assembly of a 50kW prototype test module in preparation of on-sun field tests to assess the performance of our final design.

CST, CSP, high temperature, air receiver, SiC, add↗

Investigation of temperature distribution on a new linear Fresnel receiver assembly under high solar flux

A linear Fresnel collector design with an operation temperature of 300 degrees C or above typically requires a solar flux concentration ratio of at least 20 on the surfaces of the receiver assembly. For the commercial linear Fresnel collector design in this work, the receiver assembly includes a secondary reflector and an evacuated receiver tube. The high-concentration solar flux may impose additional operating-temperature requirements on the secondary reflector and receiver tube. Thus, a careful heat-transfer analysis is necessary to understand the operating temperature of the receiver assembly component surfaces under design and off-design conditions to guide appropriate material selections. In this work, a numerical heat-transfer analysis is performed to calculate the temperature distribution of the surfaces of the secondary reflector and receiver glass envelope for a commercial collector design. Operating conditions examined in the heat-transfer analysis include various wind speeds and solar concentration ratios. The results indicate a surface temperature higher than 100 degrees C on the secondary reflector surface, which suggests that a more advanced secondary reflector material is needed. The established heat-transfer model can be used for optimization of the other types of linear Fresnel collectors.

14 SOLAR ENERGY↗

Structural design challenges and implications for high temperature concentrating solar power receivers

High operating temperatures along with diurnal cycling and high operating stresses bring many material and engineering challenges for concentrated solar power (CSP) receivers. Current design rules in ASME Boiler and Pressure Vessel (B&PV) Code for high temperature structural components were not intended for CSP components. The paper reviews the design rules in several sections of ASME B&PV Code in terms of their applicability in designing high temperature CSP receivers. With some restrictions and modifications, the conditions assumed in the design rules in Section III, Division 5 of ASME B&PV Code are found to closely resemble the loading conditions of CSP receiver, including accounting for the interaction between creep and fatigue damage. Further, the paper applies the proposed design rules to an external tubular receiver design and discusses several lessons learned from the design study. The creep damage accumulation due to high thermal stresses resulting from circumferentially non-uniform flux distribution is found to control the design of CSP receivers. Several mitigation actions to improve the design life of receivers are also discussed.

14 SOLAR ENERGY↗

Damage modeling of power tower receiver tubes using the SRLIFE tool

Concentrating Solar Power (CSP) molten-salt central receivers are subject to high, transient incident flux during daily operation. The resulting creep-fatigue damage impacts the receiver’s reliability and restricts the permissible incident flux distribution for a given receiver. This paper aims to reduce CSP plants’ levelized cost of electricity by developing a methodology to predict lifetime and identifies the primary damage mechanism (creep vs fatigue) for any given fluid temperature and temperature gradient. Results are presented in the form of a damage map that serves as a valuable operation guide and design tool. Damage maps can be used to reduce maintenance costs by improving reliability and reduce receiver capital costs by better utilizing the receiver area. FEA simulation and damage modeling of tubes subject to asymmetrical flux conditions is performed in the open-source receiver design tool srlife. Parametric studies are performed over a range of inner tube temperatures and thermal gradients for A230, 316H, 740H, A282, A617, and 800H high temperature alloys. Damage maps are presented for each alloy. A parametric, FEA-based methodology is presented for comparison of fatigue-creep ratios and prediction of tube lifetime based on the critical thermal operating conditions. Fatigue is found to be negligible compared to creep for almost every case. Here, this finding suggests that fatigue effects associated with cloud events are insignificant compared to creep at these high temperature operating conditions. Additionally, lifetime predictions identify thermal conditions where small changes in operating conditions can result in large changes in predicted lifetime.

14 SOLAR ENERGY↗

Wind load analysis of a new linear Fresnel receiver assembly design

A linear Fresnel collector includes a low-profile reflector array and a receiver assembly with one or more absorber tubes and an optional secondary reflector. This combined optical system concentrates sunlight and converts it into thermal energy. The design of a receiver assembly is critical to the performance of a linear Fresnel collector. A position deviation of a few centimeters for the receiver assembly can result in notably reduced performance, thus leading to a direct loss in revenue associated with thermal power production. Wind load is one of the most significant environmental factors that can alter the optical - and therefore thermal - performance of a solar power system due to displacements after installation. At the same time, an over-designed receiver assembly may add unnecessary construction cost to a typically high-cost-constrained system. Thus, wind load analysis is particularly important when considering optimal engineering design of a receiver assembly and its supporting structure to cost-effectively mitigate the impacts of wind. In this study, a detailed computational fluid dynamics (CFD) model is adopted to derive the wind load of a commercial linear Fresnel receiver assembly. This wind load is then used as a reference to optimize the detailed engineering design. The CFD model is first carefully developed and benchmarked within a critical regime toward turbulence. The drag force, lift force, and vortex-shedding frequencies are derived at both the operating and survival wind-speed limits for target project deployment locations. The wind load analysis results provide a valuable reference for future engineering design and prototyping.

17 WIND ENERGY↗

Thermomechanical Modeling and Analysis of a High-Temperature Light Trapping Planar Cavity Receiver

Solar energy harnessed through concentrating solar power (CSP) systems offers a promising path to sustainable energy production, with the efficiency and longevity of these systems relying on key components like solar receivers. This study analyzes the thermomechanical behavior of an innovative enclosed light-trapping solar receiver optimized for particle heating applications. The receiver utilizes sheet metal alloys to form enclosed cavities that reflect and trap incoming solar flux, as well as enclosed channels that contain fluidized particle beds absorbing solar heat. Finite element analysis (FEA) is applied to predict the receiver's thermomechanical performance under extreme solar flux conditions. Temperature distributions from a thermal model simulating a multi-panel assembly at steady state are input into the FEA thermomechanical model for stress analysis. A key aspect of the analysis focuses on evaluating creep-fatigue damage, with a design target of achieving a 30- year service life. Various stress relief techniques are also proposed to extend the receiver's service life. The results highlight the significant impact of the particle-to-wall heat transfer coefficients (HTCs), ranging from 800 W/m2*K to 1400 W/m2*K. The 800 W/m2*K case shows a maximum von Mises stress of 164 MPa, while the 1400 W/m2*K case reduces it to 150 MPa. The creep life increases from 4,000 hrs in the 800 W/m2*K case to over 100,000 hrs in the 1400 W/m2*K case with Inconel 740H used, indicating that higher HTCs reduce stress and extend lifespan. This research advances the design of high-efficiency, low-stress solar receivers for particle-based thermal energy storage in CSP and industrial heating applications.

concentrating solar power↗

Creep-fatigue Behavior and Damage Accumulation of a Candidate Structural Material for Concentrating Solar Power Solar Thermal Receiver (Final Technical Report)

Creep-fatigue deformation is an important consideration for a thermal receiver in Concentrating Solar Power systems due to the constant static stress or pressure, diurnal cycling, and elevated service temperatures required for efficient operation. An accurate description of the creep-fatigue behavior, not available for five of the six candidate materials, is important for assessment of preliminary designs. This project has provided a detailed analysis of the creep-fatigue behavior and damage accumulation of Alloy 740H, a candidate structural material for a CSP solar thermal receiver to address a critical knowledge barrier for receiver designs identified in the CSP Gen3 Demonstration Roadmap. This project was divided in to three tasks, split between two general categories: Experimental and design methodology. Tasks 1 and 3, relating to the collection of data on Alloy 740H plate and sheet forms, respectively, were performed at the Idaho National Laboratory and used as input to Task 2, the development of design methodology performed at Argonne National Laboratory. Experimental work covered limited tensile and creep testing to fill gaps in available data that is currently available and to demonstrate how the plate of Alloy 740H tested in this work compared to historical data. A more substantial testing program for fatigue and creep-fatigue was performed, with particular emphasis on creep-fatigue as there is little available data and it is necessary to understand the creep-fatigue interaction and develop related design models. This effort includes the development of rules for the design of solar receiver components against high temperature creep-fatigue and ratcheting failure modes. The ASME Code rules for high temperature nuclear components was used to the basis of the method but adjustments will be made to reflect the generally shorter, diurnal operating cycles of thermal receivers and the relative consequences of failure, comparing nuclear to solar components. This work has provided guidance for the design of components for concentrating power facilities operating at high temperatures and undergoing high, secondary thermal stresses relative to the applied primary pressure stress. The design rules were developed for the design of Generation 3 CSP tubular receivers manufactured from Alloy 740H, but are generally applicable to a wide range of component types undergoing similar loads. Procedural design rules for components to be used in conjunction with the 2019 edition of the ASME Boiler & Pressure Vessel Code and the corresponding design data for Alloy 740H have been developed. A commentary describing the rationale behind the design rules and the data underlying the design material properties, as well as an extensive set of worked sample problems detailing the application of the rules to CSP components were developed as a part of this project, with a separate report covering these aspects in detail and included in the Appendix of this report.

14 SOLAR ENERGY↗

Wideband fixed-tuned SIS receiver for 200-GHz operation

We report on the design and development of a heterodyne receiver, designed to cover the frequency range 176-256 GHz. This receiver incorporates a niobium superconductor-insulator-superconductor (SIS) tunnel junction mixer, which, chiefly for reasons of reliability and ease of operation, is a fixed-tuned waveguide design. On-chip tuning is provided to resonate out the junction's geometric capacitance and produce a good match to the waveguide circuit. Laboratory measurements on the first test receiver indicate that the required input bandwidth (about 40%) is achieved with an average receiver noise temperature of below 50 K. Mixer conversion gain is observed at some frequencies, and the lowest measured receiver noise is less than 30 K. Furthermore, the SIS mixer used in this receiver is of simple construction, is easy to assemble and is therefore a good candidate for duplication.

RECEIVER NOISE TEMPERATURE↗

Advances in central receivers for concentrating solar applications

This paper provides a review of current state-of-the-art commercial central receiver systems and emerging technologies intended to increase the outlet temperature to >700 °C. Research on particle-based, gas-based, and liquid-based receiver designs that can achieve these higher temperatures are discussed. Particle-based technologies include directly irradiated designs (free-falling, obstructed, centrifugal) and enclosed designs (gravity fed, fluidized). New gas-based receivers include micro-channel designs and light-trapping configurations that increase the surface area, heat transfer, and solar absorptance to enable higher fluxes and pressures. Liquid-based receivers and materials that are reviewed include high-temperature halide salts (chlorides and fluorides), carbonate salts, and liquid metals (sodium and lead bismuth). Advantages and challenges associated with each of the technologies and receiver designs are presented.

14 SOLAR ENERGY↗

Predictive Factors for Radiation Pneumonitis in Hodgkin Lymphoma Patients Receiving Combined-Modality Therapy

Purpose: This study sought to quantify the risk of radiation pneumonitis (RP) in Hodgkin lymphoma (HL) patients receiving mediastinal radiation therapy (RT) and to identify predictive factors for RP. Methods and Materials: We identified 75 patients with newly diagnosed HL treated with mediastinal RT and 17 patients with relapsed/refractory HL treated with mediastinal RT before or after transplant. Lung dose-volumetric parameters including mean lung dose and percentage of lungs receiving 20 Gy were calculated. Factors associated with RP were explored by use of the Fisher exact test. Results: RP developed in 7 patients (10%) who received mediastinal RT as part of initial therapy (Radiation Therapy Oncology Group Grade 1 in 6 cases). A mean lung dose of 13.5 Gy or greater (p = 0.04) and percentage of lungs receiving 20 Gy of 33.5% or greater (p = 0.009) significantly predicted for RP. RP developed in 6 patients (35%) with relapsed/refractory HL treated with peri-transplant mediastinal RT (Grade 3 in 4 cases). Pre-transplant mediastinal RT, compared with post-transplant mediastinal RT, significantly predicted for Grade 3 RP (57% vs. 0%, p = 0.015). Conclusions: We identified threshold lung metrics predicting for RP in HL patients receiving mediastinal RT as part of initial therapy, with the majority of cases being of mild severity. The risk of RP is significantly higher with peri-transplant mediastinal RT, especially among those who receive pre-transplant RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Chemotherapy on Normal Tissue Complication Probability Models of Acute Hematologic Toxicity in Patients Receiving Pelvic Intensity Modulated Radiation Therapy

Purpose: To determine how chemotherapy agents affect radiation dose parameters that correlate with acute hematologic toxicity (HT) in patients treated with pelvic intensity modulated radiation therapy (P-IMRT) and concurrent chemotherapy. Methods and Materials: We assessed HT in 141 patients who received P-IMRT for anal, gynecologic, rectal, or prostate cancers, 95 of whom received concurrent chemotherapy. Patients were separated into 4 groups: mitomycin (MMC) + 5-fluorouracil (5FU, 37 of 141), platinum ± 5FU (Cis, 32 of 141), 5FU (26 of 141), and P-IMRT alone (46 of 141). The pelvic bone was contoured as a surrogate for pelvic bone marrow (PBM) and divided into subsites: ilium, lower pelvis, and lumbosacral spine (LSS). The volumes of each region receiving 5-40 Gy were calculated. The endpoint for HT was grade ≥3 (HT3+) leukopenia, neutropenia or thrombocytopenia. Normal tissue complication probability was calculated using the Lyman-Kutcher-Burman model. Logistic regression was used to analyze association between HT3+ and dosimetric parameters. Results: Twenty-six patients experienced HT3+: 10 of 37 (27%) MMC, 14 of 32 (44%) Cis, 2 of 26 (8%) 5FU, and 0 of 46 P-IMRT. PBM dosimetric parameters were correlated with HT3+ in the MMC group but not in the Cis group. LSS dosimetric parameters were well correlated with HT3+ in both the MMC and Cis groups. Constrained optimization (0<n≤ 1) of the Lyman-Kutcher-Burman model resulted in n=1, m = 0.11, TD{sub 50} = 31 Gy for LSS in the MMC group and n=1, m = 0.27, TD{sub 50} = 35 Gy for LSS in the Cis group. Conclusions: The incidence of HT3+ depends on type of chemotherapy received. Patients receiving P-IMRT ± 5FU have better bone marrow tolerance than those receiving irradiation concurrent with either Cis or MMC. Treatment with MMC has a lower TD{sub 50} and more steeply rising normal tissue complication probability curve compared with treatment with Cis. Dose tolerance of PBM and the LSS subsite may be lower for patients treated with MMC compared with Cis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗