Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analyzing the Relationship between Tracking and Covariance for Satellite Collision Avoidance

This presentation will display statistical analysis performed with over 150,000 Conjunction Data Messages (CDMs) received for the Earth Observing System (EOS) Aqua, Aura and Terra satellites within the three year period of March 2015 through February 2018. The analysis performed demonstrates the relationship between the covariance of a secondary object and the amount of tracks it receives, as a function of Time to Closest Approach (TCA). The examination indicates that higher tracking frequencies result in lower uncertainties inclusively from the time the data is screened up until TCA. Further investigation displays the impacts of how additional observations of secondary objects lower their position uncertainties and what period of time prior to TCA convergence of the covariance can be expected depending on how well the objects are tracked. Data points from several recent EOS High Interest Events (HIEs) are used to exemplify this analysis.

Collision Avoidance↗

A common platform for DSN receiver development

NASA's Deep Space Network is currently updating a number of sub systems within the Signal Processing Centers at its Deep Space Communication Complexes in order to modernize aging equipment in the downlink receivers for telemetry, tracking, radio science, and radio astronomy. To reduce development costs and increase commonality among these traditionally custom-built receivers, the implementation team has developed a flexible architecture built primarily around commercial off-the-shelf hardware compliant with the Micro Telecommunications Computing Architecture (uTCA) specification and commercial high speed 10Gbit Ethernet switches. Custom firmware and software are being developed to perform the required signal processing functions needed to replace the legacy systems in a phased implementation approach which establishes a new digital Intermediate Frequency (IF) signal distribution system first, followed by implementations of various receiver functions as dictated by need. The first of these new receivers, the Open Loop Receiver, will come online in the Fall of 2018. A description of the new architecture, referred to as the “Common Platform”, will be provided followed by an overview of the phased implementation approach and initial OLR performance results.

Navarro, Robert↗

The Role of Pentaerythritol Tetranitrate (PETN) Aging in Determining Detonator Firing Characteristics

Pentaerythritol tetranitrate (PETN) is one of the most commonly used explosives for both military and mining applications. PETN is used in EBW (exploding bridge wire) and EFI (exploding foil initiator) detonator devices. Due the widespread usage of PETN, studies focusing on how the explosive changes with age, primarily its function in detonators has received particular interest. Aging studies have identified several factors that affect PETN detonator function over time, most notably the specific surface area of the explosive powder. Though small-scale studies have been performed on specific detonator systems with isolated batches of material, what is missing is a large statistically-significant study focusing on PETN aging characteristics - such as powder coarsening - and their influence on detonator performance. Herein we report the first large statistically viable PETN aging study focusing on four batches of PETN powder from the same stock of PETN using two stabilizers, polysaccharide and TriPEON. PETN was aged both as a free-flowing powder as well as in modified EBW RP-2 detonators, for one month at 75 °C. The PETN powder has been analyzed chemically using Fisher specific surface area analysis, SEM imaging and light scattering particle size analysis. Additionally the detonators were tested for performance through voltage-sweep threshold testing and function time measurements. Findings from the study indicate that aging at 75 °C for one month significantly changes the specific surface area and particle size of unstabilized PETN, leading to increases in detonator function time, but not detonator threshold values. Powders stabilized with TriPEON displayed less significant increases in function time, while powder stabilized with polysaccharide exhibited no aging effects, despite the high temperature aging.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Multi Sector Planning Tools for Trajectory-Based Operations

This paper discusses a suite of multi sector planning tools for trajectory-based operations that were developed and evaluated in the Airspace Operations Laboratory (AOL) at the NASA Ames Research Center. The toolset included tools for traffic load and complexity assessment as well as trajectory planning and coordination. The situation assessment tools included an integrated suite of interactive traffic displays, load tables, load graphs, and dynamic aircraft filters. The planning toolset allowed for single and multi aircraft trajectory planning and data communication-based coordination of trajectories between operators. Also newly introduced was a real-time computation of sector complexity into the toolset that operators could use in lieu of aircraft count to better estimate and manage sector workload, especially in situations with convective weather. The tools were used during a joint NASA/FAA multi sector planner simulation in the AOL in 2009 that had multiple objectives with the assessment of the effectiveness of the tools being one of them. Current air traffic control operators who were experienced as area supervisors and traffic management coordinators used the tools throughout the simulation and provided their usefulness and usability ratings in post simulation questionnaires. This paper presents these subjective assessments as well as the actual usage data that was collected during the simulation. The toolset was rated very useful and usable overall. Many elements received high scores by the operators and were used frequently and successfully. Other functions were not used at all, but various requests for new functions and capabilities were received that could be added to the toolset.

Prevot, Thomas↗

Data Format Classification for Autonomous Software Defined Radios

We present maximum-likelihood (ML) coherent and noncoherent classifiers for discriminating between NRZ and Manchester coded (biphase-L) data formats for binary phase-shift-keying (BPSK) modulation. Such classification of the data format is an essential element of so-called autonomous software defined radio (SDR) receivers (similar to so-called cognitive SDR receivers in the military application) where it is desired that the receiver perform each of its functions by extracting the appropriate knowledge from the received signal and, if possible, with as little information of the other signal parameters as possible. Small and large SNR approximations to the ML classifiers are also proposed that lead to simpler implementation with comparable performance in their respective SNR regions. Numerical performance results obtained by a combination of computer simulation and, wherever possible, theoretical analyses, are presented and comparisons are made among the various configurations based on the probability of misclassification as a performance criterion. Extensions to other modulations such as QPSK are readily accomplished using the same methods described in the paper.

classification↗

Hybrid receiver study

The results are presented of a 4 month study to design a hybrid analog/digital receiver for outer planet mission probe communication links. The scope of this study includes functional design of the receiver; comparisons between analog and digital processing; hardware tradeoffs for key components including frequency generators, A/D converters, and digital processors; development and simulation of the processing algorithms for acquisition, tracking, and demodulation; and detailed design of the receiver in order to determine its size, weight, power, reliability, and radiation hardness. In addition, an evaluation was made of the receiver's capabilities to perform accurate measurement of signal strength and frequency for radio science missions.

Stone, M. S.↗

Hypofractionated Intensity-Modulated Radiotherapy for Carcinoma of the Prostate: Analysis of Toxicity

Purpose: Dose escalation for prostate cancer improves biological control but with a significant increase in late toxicity. Recent estimates of low {alpha}/{beta} ratio for prostate cancer suggest that hypofractionation may result in biological advantage. Intensity-modulated radiotherapy (IMRT) should enable dose escalation to the prostate while reducing toxicity to local organs. We report late toxicity data of a hypofractionated IMRT regime. Methods and Materials: Eligible men had T2-3N0M0 adenocarcinoma prostate, and either Gleason score {>=} 7 or prostate-specific antigen 20-50 ng/L. Patients received 57-60 Gy to prostate in 19-20 fractions using five-field IMRT. All received hormonal therapy for 3 months before radiotherapy to a maximum of 6 months. Toxicity was assessed 2 years postradiotherapy using the RTOG criteria, LENT/SOMA, and UCLA prostate index assessment tools. Results: Acute toxicity was favorable with no RTOG Grade 3 or 4 toxicity. At 2 years, there was 4% Grade 2 bowel and 4.25% Grade 2 bladder toxicity. There was no Grade 3 or 4 bowel toxicity; one patient developed Grade 3 bladder toxicity. UCLA data showed a slight improvement in urinary function at 2 years compared with pretreatment. LENT/SOMA assessments demonstrated general worsening of bowel function at 2 years. Patients receiving 60 Gy were more likely to develop problems with bowel function than those receiving 57 Gy. Conclusions: These data demonstrate that hypofractionated radiotherapy using IMRT for prostate cancer is well tolerated with minimal late toxicity at 2 years posttreatment. Ongoing studies are looking at the efficacy of hypofractionated regimes with respect to biological control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultra-wideband mutual coupling compensation of active electronically scanned arrays in multi-channel radar systems

Technologies pertaining to the calibration of ultra-wide-band active-electronically-scanned arrays to compensate for transmit and receive mutual coupling between array elements and/or non-ideal isolated channels are described herein. A plurality of near-field measurements are taken by way of probe or probes that may be moved among a plurality of positions aligned with respective elements in the array. For each position of the probe, each of the elements of the array is stimulated to transmit or receive a calibration signal to or from the probe, respectively. Frequency-domain transfer functions are computed from the received signals by the probe or the element for each of the array elements in each of the positions of the probe. The inverse of the matrix of transfer functions comprise frequency-domain transmit and receive correction factors that are used to modify desired array inputs/outputs such that the modified signals correct for mutual coupling between elements in the array.

42 ENGINEERING↗

A Prospective Phase 2 Trial of Reirradiation With Stereotactic Body Radiation Therapy Plus Cetuximab in Patients With Previously Irradiated Recurrent Squamous Cell Carcinoma of the Head and Neck

Purpose: Salvage options for unresectable locally recurrent, previously irradiated squamous cell carcinoma of the head and neck (rSCCHN) are limited. Although the addition of reirradiation may improve outcomes compared to chemotherapy alone, significant toxicities limit salvage reirradiation strategies, leading to suboptimal outcomes. We therefore designed a phase 2 protocol to evaluate the efficacy of stereotactic body radiation therapy (SBRT) plus cetuximab for rSCCHN. Methods and Materials: From July 2007 to March 2013, 50 patients >18 years of age with inoperable locoregionally confined rSCCHN within a previously irradiated field receiving ≥60 Gy, with a Zubrod performance status of 0 to 2, and normal hepatic and renal function were enrolled. Patients received concurrent cetuximab (400 mg/m{sup 2} on day −7 and then 250 mg/m{sup 2} on days 0 and +8) plus SBRT (40-44 Gy in 5 fractions on alternating days over 1-2 weeks). Primary endpoints were 1-year locoregional progression-free survival and National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0 graded toxicity. Results: Median follow-up for surviving patients was 18 months (range: 10-70). The 1-year local PFS rate was 60% (95% confidence interval [CI]: 44%-75%), locoregional PFS was 37% (95% CI: 23%-53%), distant PFS was 71% (95% CI: 54%-85%), and PFS was 33% (95% CI: 20%-49%). The median overall survival was 10 months (95% CI: 7-16), with a 1-year overall survival of 40% (95% CI: 26%-54%). At last follow-up, 69% died of disease, 4% died with disease, 15% died without progression, 10% were alive without progression, and 2% were alive with progression. Acute and late grade 3 toxicity was observed in 6% of patients respectively. Conclusions: SBRT with concurrent cetuximab appears to be a safe salvage treatment for rSCCHN of short overall treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retinal Light Processing Using Carbon Nanotubes

Method and system for processing light signals received by the eye of a human or other animal, where the eye may be compromised or non-functioning. Incident light is received at first and second pixels in a photodetector array and provides a pixel electrical signal representing the received light. Each of an array of carbon nanotube (CNT) towers is connected to a pixel, has a first tower end penetrating a retinal active layer of the animal and has a second tower end positioned to receive to receive and transport the pixel electrical signal to the retinal active layer. The CNT tower may be coated with a biologically active substance or chemically modified to promote neurite connections with the tower. The photoreceptor array can be provide with a signal altering mechanism that alters at least one of light intensity and wavelength intensity sensed by a first pixel relative to a second pixel, to correct for one or more selected eye problems.

David J Loftus↗

Functional image-guided stereotactic body radiation therapy planning for patients with hepatocellular carcinoma

The aim of the current planning study is to evaluate the ability of gadoxetate disodium-enhanced magnetic resonance imaging (EOB-MRI)–guided stereotactic body radiation therapy (SBRT) planning by using intensity-modulated radiation therapy (IMRT) techniques in sparing the functional liver tissues during SBRT for hepatocellular carcinoma. In this study, 20 patients with hepatocellular carcinoma were enrolled. Functional liver tissues were defined according to quantitative liver-spleen contrast ratios ≥ 1.5 on a hepatobiliary phase scan. Functional images were fused with the planning computed tomography (CT) images; the following 2 SBRT plans were designed using a “step-and-shoot” static IMRT technique for each patient: (1) an anatomical SBRT plan optimization based on the total liver; and (2) a functional SBRT plan based on the functional liver. The total prescribed dose was 48 gray (Gy) in 4 fractions. Dosimetric parameters, including dose to 95% of the planning target volume (PTV D{sub 95%}), percentages of total and functional liver volumes, which received doses from 5 to 30 Gy (V5 to V30 and fV5 to fV30), and mean doses to total and functional liver (MLD and fMLD, respectively) of the 2 plans were compared. Compared with anatomical plans, functional image-guided SBRT plans reduced MLD (mean: plan A, 5.5 Gy; and plan F, 5.1 Gy; p < 0.0001) and fMLD (mean: plan A, 5.4 Gy; and plan F, 4.9 Gy; p < 0.0001), as well as V5 to V30 and fV5 to fV30. No differences were noted in PTV coverage and nonhepatic organs at risk (OARs) doses. In conclusion, EOB-MRI–guided SBRT planning using the IMRT technique may preserve functional liver tissues in patients with hepatocellular carcinoma (HCC).

61 RADIATION PROTECTION AND DOSIMETRY↗

Time delay and distance measurement

A method for measuring time delay and distance may include providing an electromagnetic radiation carrier frequency and modulating one or more of amplitude, phase, frequency, polarization, and pointing angle of the carrier frequency with a return to zero (RZ) pseudo random noise (PN) code. The RZ PN code may have a constant bit period and a pulse duration that is less than the bit period. A receiver may detect the electromagnetic radiation and calculate the scattering profile versus time (or range) by computing a cross correlation function between the recorded received signal and a three-state RZ PN code kernel in the receiver. The method also may be used for pulse delay time (i.e., PPM) communications.

Abshire, James B.↗

Ultra-Low-Noise W-Band MMIC Detector Modules

A monolithic microwave integrated circuit (MMIC) receiver can be used as a building block for next-generation radio astronomy instruments that are scalable to hundreds or thousands of pixels. W-band (75-110 GHz) low-noise receivers are needed for radio astronomy interferometers and spectrometers, and can be used in missile radar and security imagers. These receivers need to be designed to be mass-producible to increase the sensitivity of the instrument. This innovation is a prototyped single-sideband MMIC receiver that has all the receiver front-end functionality in one small and planar module. The planar module is easy to assemble in volume and does not require tuning of individual receivers. This makes this design low-cost in large volumes.

Gaier, Todd C.↗

Input-output characterization of fiber composites by SH waves

Input-output characterization of fiber composites is studied theoretically by tracing SH waves in the media. A fiberglass epoxy composite is modeled as a homogeneous transversely isotropic continuum plate. The reflection of an SH wave at a stress-free plane boundary in a semi-infinite transversely isotropic medium is considered first. It is found that an incident SH wave reflects only a similar SH wave back into the medium. It is also established that the angle of reflection of the reflected wave is equal to the angle of incidence of the incident wave. The phase velocity of the SH waves and the delay time of the SH waves in reaching the receiving transducer are computed as functions of a reflection index, defined as the number of reflections of the SH waves from the bottom face of the continuum plate. The directivity function corresponding to the shear stress associated with the SH waves in the continuum plate is also derived as a function of the reflection index. A theoretical output voltage from the receiving transducer is calculated for a tone burst (a periodic input voltage of finite duration). The output voltage is shown for tone bursts of duration 60 microseconds and center frequencies of 0.75, 1.00, and 1.25 MHz. The study enhances the quantitative and qualitative understanding of the nondestructive evaluation (NDE) of fiber composites which can be modeled as transversely isotropic media.

Renneisen, John D.↗

Flight test of 4-Hz and 30-Hz Omega receiver front-end

In-flight information was gathered on two Omega receiver analog modules, one having a 4-Hz bandwidth and the other a 30-Hz bandwidth. The Mini-O receiver was also monitored. An improved signal-to-noise characteristic of the narrower bandwidth front-end with negligible loss in dynamic range indicates that the 4-Hz front-end is the more desirable for the prototype Omega receivers. The Mini-O receiver was found to function quite satisfactorily on its second test flight, and has a very real potential for a low-cost, low-power, compact and light-weight Omega receiver.

Wright, L.↗

Extremum seeking control of distributed energy resources with decaying dither and equilibrium-based switching

Embodiments relate to an operating system coupled to and controlling at least one Distributed Energy Resource (DER) in a smart grid and includes an electricity distribution network and a 2-dimensional Extremum Seeking (2D-ES) controller coupled to network. The electricity distribution network has first and second inputs and one output and maps all active power and reactive power inputs to the smart grid providing measurements of an objective function. The 2D-ES controller controls the DER and includes an active power loop and a reactive power loop. The active power loop is in communication with the first input and the output, governs active power contribution, and receives measurements of the objective function which contain static and oscillatory components. The reactive power loop is in communication with the second input and the output, governs reactive power contribution, and receives measurements of the objective function which contain static and oscillatory components.

Arnold, Daniel↗