Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioxenon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

History and Future of Isotope Production

Operations at the IPF were initiated in October 1976. LAMPF was delivering 800 MeV protons at a current of 300 µA. Initially, only pure-metal targets were selected for irradiation. These included Mo, Ni, Ta, Si, V, Al and Cu, which ranged in mass from a few to several hundred g. One program required a multi-Ci quantity of 88 Y that necessitated the irradiation and processing of more than 5 kg of Mo metal. As experience was gained, it was learned that oxide and salt targets could safely be irradiated, and eventually the sweeping and cold trapping of radioxenon gas from a molten CsCl during irradiation. Operations ended in 1992.

07 ISOTOPE AND RADIATION SOURCES↗

Watchmen 3.0.0 Users Guide: Revision 6

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.1.0 Users Guide: Revision 7

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen v3.2.0 User Guide: Revision 8

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.3.0 User Guide: Revision 9

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Beowulf v2.5.3 User Guide: Revision 5

This document is a user guide for the Beowulf (rebranding of Watchmen) tool. It describes how operators can access and utilize the application's functionality. Beowulf is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. These stations are part of a worldwide network to monitor for nuclear explosions, and the data they produce are critical to make the determination of whether a sample is from a nuclear explosion or some other source (i.e., nuclear reactor or medical isotope production facility). Stations deliver their measurements and system status to the International Monitoring System (IMS), which forwards it via email to all subscribers. Beowulf is capable of processing data from several radioxenon station types and development is in progress on a solution for particulate stations. Screening of data in Beowulf may be done by a number of different users such as radionuclide analysts, evaluators, and data quality experts. This guide is provided to assist those users in navigating the application. The term Beowulf is used generically throughout this document to refer to any of the various components in the software application. The user interface that is viewed with a web browser is the primary focus of this user guide. Other components include a database to store measurements and state of health (SOH) data; and the data loader that monitors incoming emails, parses the data, populates the database, does the initial analysis, and routes data for review.

97 MATHEMATICS AND COMPUTING↗

Ultrafast Laser-Excited Optical Emission of Xe under Loose-Focusing Conditions

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air–Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

47 OTHER INSTRUMENTATION↗

Initial Beta-Gamma Nuclear Detector Background Study

Detection of underground nuclear explosions and, more recently, nuclear reactor events is of great national interest. These measurements are most often made by determining the concentration of radioactive noble gases in the atmosphere. Currently there are several ground-based systems capable of making radioxenon gas measurements. The measurement is often close to the detection limit, so understanding the parameters and features that limit the measurement is very important. A preliminary study of the detection limit has been performed using a -Quad detector designed at Pacific Northwest National Laboratory (PNNL). The initial study has concentrated on the measuring the ambient radioactive background. By making several background measurements while varying the detector, shielding it is possible to identify whether the ambient background is internal or external to the detector. Furthermore, internal background contributions can be potentially reduced by selecting alternative low-background materials, while external background can be reduced by increasing the active or passive shielding present. By reducing the background contributions, it is possible to improve the detection limit and therefore the likelihood of positively identifying a nuclear test.

Cooper, Matthew W.↗

A low-permeability underground nuclear explosion containment regime: An example of gas transport by “invisible” fractures?

Understanding the nature of gas transport from an underground nuclear explosion (UNE) is required for evaluating the ability to detect and interpret either on-site or atmospheric signatures of noble gas radionuclides resulting from the event. We performed a pressure and chemical tracer monitoring experiment at the site of an underground nuclear test that occurred in a tunnel in Nevada to evaluate the possible modes of gas transport to the surface. The site represents a very well-contained, low gaspermeability end member for past UNEs at the Nevada National Security Site. However, there is very strong evidence that gases detected at the surface during a period of low atmospheric pressure resulted from fractures of extremely small aperture that are essentially invisible. Our analyses also suggest that gases would have easily migrated to the top of the high-permeability collapse zone following the detonation minimizing the final distance required for migration along these narrow fractures to the surface. This indicates that on-site detection of gases emanating from such low-permeability sites is feasible while standoff detection of atmospheric plumes may also be possible at local distances for sufficiently high fracture densities. Finally, our results show that gas leakage into the atmosphere also occurred directly from the tunnel portal and should be monitored in future tunnel gas sampling experiments for the purpose of better understanding relative contributions to detection of radioxenon releases via both fracture network and tunnel transport.

58 GEOSCIENCES↗

Production of Xenon-135 from isotopically enriched Xenon-134 and Xenon-136 Targets

Atmospheric radioxenon analyses conducted under the Comprehensive Test Ban Treaty Organization (CTBTO) necessitates the collection and analysis of air samples to quantify 135Xe, an indicator for nuclear explosions and reactor operations. Analytical instrument calibration for these analyses requires high quality, monoisotopic reference standards that are typically short lived, and therefore must be produced and shipped promptly to monitoring stations worldwide. This work describes the preparation of 135Xe by neutron capture (n, ?) on monoisotopic 134Xe, neutron irradiation (n,2n) on monoisotopic 136Xe, and high energy photon irradiation (?, n) on monoisotopic 136Xe. The targets are prepared by electromagnetic isotope separation of natural xenon. Results from each process are compared for 135Xe yield and purity.

07 ISOTOPE AND RADIATION SOURCES↗

Radiological Source Term Estimates of the Fukushima Daiichi Nuclear Accident

In the aftermath of a radiological disaster, it is desirable to predict and estimate the amount of radionuclides released into the atmosphere and environment. We obtained an estimate for radioxenon activity released into the atmosphere during the Fukushima accident by minimizing the discrepancy between the measured activity at several International Monitoring System (IMS) detectors and that obtained with the FLEXPART atmospheric transport modeling (ATM) code.

07 ISOTOPE AND RADIATION SOURCES↗

Finite Element Modeling of Adsorption Processes for Gas Separation and Purification

Pacific Northwest National Laboratory (PNNL) has expertise in the design and fabrication of automated radioxenon collection systems for nuclear explosion monitoring. In developing new systems there is an ever present need to reduce size, power consumption and complexity. Most of these systems have used adsorption based techniques for gas collection and/or concentration and purification. These processes include pressure swing adsorption, vacuum swing adsorption, temperature swing adsorption, gas chromatography and hybrid processes that combine elements of these techniques. To better understand these processes, and help with the development of improved hardware, a finite element software package (COMSOL Multiphysics) has been used to develop complex models of these adsorption based operations. The partial differential equations used include a mass balance for each gas species and adsorbed species along with a convection conduction energy balance equation. These equations in conjunction with multicomponent temperature dependent isotherm models are capable of simulating separation processes ranging from complex multibed PSA processes, and multicomponent temperature programmed gas chromatography, to simple two component temperature swing adsorption. These numerical simulations have been a valuable tool for assessing the capability of proposed processes and optimizing hardware and process parameters.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SDAT – Analysis of 131mXe with 133Xe Interference

The Spectral Deconvolution Analysis Tool (SDAT) software was developed at The University of Texas at Austin. SDAT utilizes a standard spectrum technique for the analysis of beta-gamma coincidence spectra. Testing was performed on the software to compare the standard spectrum analysis technique with a region of interest (ROI) analysis technique. Experimentally produced standard spectra and sample data were produced at the Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor. The results of the testing showed that the standard spectrum technique had lower errors than the ROI analysis technique for samples with low counting statistics. In contrast, the ROI analysis technique outperformed the standard spectrum technique in high counting statistics samples. It was also shown that the standard spectrum technique benefitted from a compression of the number of channels within the spectra.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Modeling the use of mobile modular gas samplers in near-field detection

The Wireless Independent Noble Gas Sampler (WINGS) is a mobile, modular gas sampling system designed for use in low infrastructure environments. In the case of a suspected underground nuclear explosion (UNE), WINGS units could be deployed to detect noble gases emanating from the suspected explosion site or identify gases originating from another source entering the local area from offsite. In conclusion, this work uses the atmospheric transport modeling tool inline WRF-HYSPLIT to test the effectiveness of WINGS units around a suspected UNE site as a function of sampler density and distance from the emission point of gases from a UNE.

Air sampling↗

Transportable Xenon Laboratory (TXL-1) Operations Manual

The Transportable Xenon Laboratory Operations Manual is a guide to set up and shut down TXL, a fully contained laboratory made up of instruments to identify and measure concentrations of the radioactive isotopes of xenon by taking air samples and analyzing them. The TXL is housed in a standard-sized shipping container. TXL can be shipped to and function in any country in the world.

atmospheric radioxenon concentration↗

Discrimination of nuclear explosions against civilian sources based on atmospheric xenon isotopic activity ratios

A global monitoring system for atmospheric xenon radioactivity is being established as part of the International Monitoring System that will be used to verify compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) once the treaty has entered into force. This paper studies isotopic activity ratios to support interpretation of observed atmospheric concentrations of 135Xe, 133mXe, 133Xe and 131mXe. The goal is to distinguish nuclear explosion sources from civilian releases. Simulations of nuclear explosions, empirical data for both test and reactor releases as well as observations by measurement stations of the International Noble Gas Experiment (INGE) are used to provide a proof of concept for the isotopic ratio based method for source discrimination.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗