Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiological emergency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

150 records · Page 9

Revealing Structural Evolution of Nickel Phosphide-Iron Oxide Core–Shell Nanocatalysts in Alkaline Medium for the Oxygen Evolution Reaction

Metal phosphide-containing materials have emerged as a potential candidate of non-precious metal-based catalysts for alkaline oxygen evolution reaction (OER). While it is known that metal phosphide undergoes structural evolution, considerable debate persists regarding the effects of dynamics on the surface activation and morphological stability of the catalysts. In this study, we synthesize NiP x -FeO x core-shell nanocatalysts with an amorphous NiP x core designed for enhanced OER activity. Using ex-situ X-ray absorption spectroscopy, we elucidate the local structural changes as a function of cyclic voltammetry cycles. Our studies suggest that the presence of corner-sharing octahedra in the FeO x shell improves structural rigidity through interlayer cross-linking, thereby inhibiting the diffusion of OH - /H 2 O. Thus, the FeO x shell preserves the amorphous NiP x core from rapid oxidation to Ni 3 (PO 4 ) 2 and Ni(OH) 2 . On the other hand, the incorporation of Ni from the core into the FeO x shell facilitates absorption of hydroxide ions for OER. As a result, the Ni/Fe(OH) x at the surface oxidizes to the active γ-(oxy)hydroxide phase under the applied potentials, promoting OER. This intriguing synergistic behavior holds significance as such synthetic route involving the FeO x shell can be extended to other systems, enabling manipulation of surface adsorption and diffusion of hydroxide ions. These findings also demonstrate that nanomaterials with core-shell morphology can be tuned to leverage the strength of each metallic component for improved electrochemical activities.

25 ENERGY STORAGE↗

Production and purification of research scale 161 Tb using cation-exchange semi-preparative HPLC for radiopharmaceutical applications

Terbium-161 ( 161 Tb) is emerging as a promising radionuclide for cancer therapy due to its favorable nuclear properties that are similar to clinically established lutetium-177 ( 177 Lu) along with its therapeutic edge arising from the higher number of Auger and conversion electrons per decay. These low energy electrons result in higher cytotoxicity within a short range of the decaying nuclei to enhance therapeutic efficacy. Despite these promising characteristics, a significant challenge remains in the lack of a domestic 161 Tb supply in the United States, which poses an obstacle to the advancement of 161 Tb-based radiopharmaceutical research and development. Here, this study developed a reliable cation-exchange high-performance liquid chromatography-based method for purification of reactor-produced 161 Tb at quantities suitable to support research and preclinical studies. The purified 161 Tb product showed high radionuclidic purity with excellent radiochemical purity, and the successful labeling studies with the DOTA chelator and DOTA-TATE peptide demonstrated the effective incorporation of the purified 161 Tb into radiopharmaceuticals designed for targeted cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Injury Induced by Photon and Proton Therapies: Gaps and Opportunities

Despite technological advances in radiation therapy (RT) and cancer treatment, patients still experience adverse effects. Proton therapy (PT) has emerged as a valuable RT modality that can improve treatment outcomes. Normal tissue injury is an important determinant of the outcome; therefore, for this review, we analyzed 2 databases: (1) clinical trials registered with ClinicalTrials.gov and (2) the literature on PT in PubMed, which shows a steady increase in the number of publications. Most studies in PT registered with ClinicalTrials.gov with results available are nonrandomized early phase studies with a relatively small number of patients enrolled. From the larger database of nonrandomized trials, we listed adverse events in specific organs/sites among patients with cancer who are treated with photons and protons to identify critical issues. The present data demonstrate dosimetric advantages of PT with favorable toxicity profiles and form the basis for comparative randomized prospective trials. A comparative analysis of 3 recently completed randomized trials for normal tissue toxicities suggests that for early stage non-small cell lung cancer, no meaningful comparison could be made between stereotactic body RT and stereotactic body PT due to low accrual (NCT01511081). In addition, for locally advanced non-small cell lung cancer, a comparison of intensity modulated RT with passive scattering PT (now largely replaced by spot-scanned intensity modulated PT), PT did not provide any benefit in normal tissue toxicity or locoregional failure over photon therapy. Finally, for locally advanced esophageal cancer, proton beam therapy provided a lower total toxicity burden but did not improve progression-free survival and quality of life (NCT01512589). The purpose of this review is to inform the limitations of current trials looking at protons and photons, considering that advances in technology, physics, and biology are a continuum, and to advocate for future trials geared toward accurate precision RT that need to be viewed as an iterative process in a defined path toward delivering optimal radiation treatment. A foundational understanding of the radiobiologic differences between protons and photons in tumor and normal tissue responses is fundamental to, and necessary for, determining the suitability of a given type of biologically optimized RT to a patient or cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear excitation functions for medical isotope production: Targeted radionuclide therapy via nat IR$(d, x)$ 193m Pt

193m Pt is an Auger emitting radionuclide which may have therapeutic potential, particularly when labeled to the chemotherapeutic drug cisplatin. One challenge to broader explorations of its clinical potential is the need for production routes with high specific activity. As part of a larger campaign to address gaps in reaction data for emerging medical radionuclides, this work seeks to characterize the nat Ir(d,x) reactions as a potential production pathway for 193m Pt. A stacked target irradiation, consisting of natural iridium, iron, nickel, and copper foils, was performed using a 33 MeV deuteron beam at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. This measurement, along with previous experimental data, suggests an energy window between 11 to 18 MeV to maximize the production and radiopurity of 193m Pt. This experiment has yielded cross sections for 43 channels of deuteron-induced reactions from threshold to 30 MeV, including the first experimental results of nat Ir(d,x) 188m1+g,190m1+g Ir (cumulative), nat Ni(d,x) 56,57,58 m,58g Co (independent), nat Cu(d,x) 61 Co (cumulative) and nat Fe(d,x) 53 Fe, 48 V (cumulative). The results were compared with literature data, the TENDL-2023 database, and default theoretical calculations from the TALYS-2.04, CoH-3.6.0, EMPIRE 3.2.3, and ALICE-2020 reaction modeling codes. Here, this work presents another example of the lack of predictive capabilities for this set of modern nuclear-reaction modeling codes, and highlights the unsatisfactory modeling of experimental cross sections. Experimental data are important to improve the codes in general, and new experimental results can be used to improve the models. Finally, this measurement has revealed the need for an updated evaluation of the nat Cu(d,x) 63 Zn deuteron monitor reaction.

193mPt↗

Defect-Engineered High-Entropy Spinel Oxide@Onion-Like Carbon Catalysts for High-Areal-Energy Rechargeable Zinc–Air Batteries

Rechargeable zinc-air batteries (ReZAB) have emerged as the next-generation batteries with several advantages over the conventional lithium-ion battery. In this work, single nanocrystals of inverse-type high-entropy spinel oxides (HESOx, particle size of 10−12 nm) confined in highly curved defective onion-like carbons (HESOx/OLC AT ) as efficient electrocatalysts for oxygen evolution reaction (OER), oxygen reduction reaction (ORR), and ReZAB, have been synthesized. The HESOx materials were thoroughly characterized using several analytical techniques, including X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning transmission electron microscopy (STEM), Raman, and electron paramagnetic resonance (EPR). HESOx/OLC AT catalyst was tested for ReZAB using literature-recommended parameters that would allow for real technological application. These parameters include a current loading of 10 mA cm −2 and a discharge areal energy density of 35 mWh cm geometric −2 , which maps a Li-ion battery pack-level specific energy of 120 Wh kg pack −1 . HESOx/OLC AT electrocatalysts allowed for continuous discharging and charging at a current loading of 10 mA cm −2 with discharge areal energy densities between 37 and 74 mWh cm geometric −2 , thus outperforming the recommended threshold of 35 mWh cm geometric −2 . Considering that most studies (>90%) hardly meet the recommended threshold for technological application of ReZAB, the present work represents one of the top-performing electrocatalysts for ReZAB. The excellent electrocatalytic properties of defect-rich HESOx/OLC AT toward ORR/OER and ReZAB are governed by the strong electronic modulation arising from d-π hybridization, the availability of multiple catalytic sites for intermediates, and weakened d-band centers of the rate-determining intermediates (i.e., *O adsorption for ORR and *OOH formation for OER) compared to the pristine HESOx. This work introduces an effective approach for the design and synthesis of single nanocrystals of high-entropy electrocatalysts for the development of low-cost, robust, and technologically relevant rechargeable zinc−air batteries.

25 ENERGY STORAGE↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗