Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiography modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analysis of fractal dimensions of rat bones from film and digital images

OBJECTIVES: (1) To compare the effect of two different intra-oral image receptors on estimates of fractal dimension; and (2) to determine the variations in fractal dimensions between the femur, tibia and humerus of the rat and between their proximal, middle and distal regions. METHODS: The left femur, tibia and humerus from 24 4-6-month-old Sprague-Dawley rats were radiographed using intra-oral film and a charge-coupled device (CCD). Films were digitized at a pixel density comparable to the CCD using a flat-bed scanner. Square regions of interest were selected from proximal, middle, and distal regions of each bone. Fractal dimensions were estimated from the slope of regression lines fitted to plots of log power against log spatial frequency. RESULTS: The fractal dimensions estimates from digitized films were significantly greater than those produced from the CCD (P=0.0008). Estimated fractal dimensions of three types of bone were not significantly different (P=0.0544); however, the three regions of bones were significantly different (P=0.0239). The fractal dimensions estimated from radiographs of the proximal and distal regions of the bones were lower than comparable estimates obtained from the middle region. CONCLUSIONS: Different types of image receptors significantly affect estimates of fractal dimension. There was no difference in the fractal dimensions of the different bones but the three regions differed significantly.

NASA Discipline Musculoskeletal↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗

Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

FAST Irradiations, Postirradiation Examinations, and Modeling of U-Mo for Light Water Reactor Applications

Many next generation light water reactor (LWR) concepts, such as mobile small modular reactors, are seeking to use smaller core dimensions than conventional reactor types. Smaller reactor cores require an increase in fissile material to maintain reactivity. For non-proliferation purposes, enrichment increases are limited to less than 20% (high assay low enriched uranium, [HALEU]) and so higher uranium density fuels than UO 2 must be considered. To this end, uranium-molybdenum alloys were tested using the Fission Accelerated Steady-state Test (FAST) approach. The experiment test matrix is focused on identifying the temperature transition between low swelling and high fission gas retention to break away swelling and low fission gas retention. This paper documents the results of irradiation tests and post-irradiation examinations (PIE) including neutron radiography, rodlet profilometry, fission gas collection analysis, and optical metallography. The results of these tests showed that unconstrained U-Mo fuels (solid, Na-bonded rodlets) have a swelling threshold between 400-450°C with minimal fission gas release below this point. Higher temperature solid fuel showed microstructural zoning with small pore networks while lower temperature solid fuels have a uniform microstructure with large pore networks. U-Annular Mo fuels where swelling had some self-constraint imposed upon it, were shown to have much reduced swelling compared to their solid counterparts as well as very low fission gas release for irradiation temperatures up to 500°C. These initial results show that the use of U-Mo in constrained fuel geometries could be used as a high uranium density HALEU fuel for LWRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring thermal runaway propagation in Li-ion batteries through high-speed X-ray imaging and thermal analysis: Impact of cell chemistry and electrical connections

Battery safety design is important to consider from the individual Li-ion cell to the level of the macro-system. On the macro-level, failure in one single cell can lead to propagation of the thermal runaway and rapidly set a whole battery pack on fire. Factors that can impact the propagation outcome, such as cell model/chemistry and electrical connection are here investigated using a combination of measurements. Several abusive tests were conducted, combining two different cell models (Molicel P42A and LG M50, both 21700s) in series and parallel connections (16 tests per configuration). Overall, a propagation outcome of 56% was measured from the 32 conducted tests, a minimum temperature of 150 °C was required to initiate propagation, and the fastest propagation occurred in 123 s. Temperature measurements were higher in series connected cells, initiating the discussion of cell chemistry and internal resistance on this effect. The difference in current-flow during thermal runaway in series and parallel connections, and how this can affect the temperature evolution is further discussed. Spatio-temporal mapping of X-ray radiography allowed us to derive the speed of thermal runaway evolution inside the battery and has shown that series connected cells, in particular P42A, occur faster. It was further observed that deviant sidewall behaviors such as temperature-induced breaches and pressure-induced ruptures occurred in P42As only respective nail-penetrated cells only.

25 ENERGY STORAGE↗

Observing the onset of pressure-driven K-shell delocalization

The gravitational pressure in many astrophysical objects exceeds one gigabar (one billion atmospheres), creating extreme conditions where the distance between nuclei approaches the size of the K shell. This close proximity modifies these tightly bound states and, above a certain pressure, drives them into a delocalized state. Both processes substantially affect the equation of state and radiation transport and, therefore, the structure and evolution of these objects. Still, our understanding of this transition is far from satisfactory and experimental data are sparse. Here, in this work, we report on experiments that create and diagnose matter at pressures exceeding three gigabars at the National Ignition Facility where 184 laser beams imploded a beryllium shell. Bright X-ray flashes enable precision radiography and X-ray Thomson scattering that reveal both the macroscopic conditions and the microscopic states. The data show clear signs of quantum-degenerate electrons in states reaching 30 times compression, and a temperature of around two million kelvins. At the most extreme conditions, we observe strongly reduced elastic scattering, which mainly originates from K-shell electrons. We attribute this reduction to the onset of delocalization of the remaining K-shell electron. With this interpretation, the ion charge inferred from the scattering data agrees well with ab initio simulations, but it is significantly higher than widely used analytical models predict.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing Reliability of NDE Flaw Detection Using Smaller Number of Demonstration Data Points

The paper provides an engineering analysis approach for assessing reliability of NDE flaw detection using smaller number of demonstration data points. It explores dependence of probability of detection (POD), probability of false positive (POF), on contrast-to-noise ratio, and net decision threshold-to-noise ratio in a simulated data; and draws some generically applicable inferences to devise the approach. ASTM nondestructive evaluation standards provide requirements on signal-to-noise ratio and/or contrast-to-noise ratio in order to provide reliable flaw detection and limit false positive calls. POD analysis of inspection test data results in an estimated flaw size, denoted by 𝑎90/95. This flaw size has 90% POD and minimum 95% confidence. POF is also estimated in the analysis. POD demonstration requires specimens with flaws of known size. In many situations, it is very expensive to produce the large number of flaws required for the POD analysis. In some situations, only real flaws can truly represent the flaws for demonstration. Real flaws of correct size and location in part configuration specimen may be difficult to produce, if not impossible. Here, an engineering analysis approach is devised using simulation to assess reliability of NDE technique when a limited number of flaws are available for demonstration. In this simulation, a technique is considered reliable, if it provides flaw detectability size equal to or better than the theoretical 𝑎90𝑡ℎ used in simulation and also provides a POF less than or equal to a chosen value. The paper uses simulated signal response versus flaw size data to devise the approach. Linear correlation is used between the signal response data and flaw size. POD software mh1823 uses generalized linear model (GLM) in POD analysis after transforming the flaw size and signal response, if needed, using logarithm. Therefore, this approach is in agreement with the linear signal correlation used in mh1823. Using the POD analysis of data, generic conditions on contrast-to-noise ratio and net decision threshold-to-noise ratio are derived for reliable flaw detection. In order to assess technique reliability using the engineering approach, signal response-to-flaw size correlation about the flaw size of concern is needed. In addition, measurement of noise is also needed. If the technique meets the above requirements, assumption of linear signal-to-flaw size correlation and conditions on noise, then the technique can be assessed using this analysis as it fits the underlying POD model used here. The approach is conservative and is designed to provide a larger flaw size compared to the POD approach. Such NDE technique assessment approach, although, not as rigorous as POD, can be cost effective if the larger flaw size can be tolerated. Typically, this is a situation for all quality control NDE inspections. Here, an NDE technique needs to be reliable and 𝑎90/95 is not estimated, but the assessed flaw size is assumed to be larger than the unknown a90 due to conservative factors or margins. Applicability of the approach for assessing reliability of flaw detection in x-ray radiography and 2D imaging in general is also explored.

Koshti, Ajay M.↗

Resistive Wall Simulations for the DARHT Multi-Pulse Test Line

The multi-pulse test line (MPTL) presently under T development at the Dual Axis Radiography Hydrodynamic Test (DARHT) facility may have several meters of drifting beam transport without external magnetic focusing field. The absence of external magnetic focusing is the worst case for growth of the resistive-wall instability. This instability is usually considered to be strictly a long-pulse (low-frequency) problem, but has been theoretically shown to couple the multiple pulses in a long pulse train, such as are expected to be the subject of experimentation on the MPTL. In this note, we explore the resistive wall instability in the MPTL parameter range using our LAMDA beam dynamics code. (LAMDA stands for Linear Accelerator Model for DARHT)

43 PARTICLE ACCELERATORS↗

Using neutrons and x rays to measure plasma conditions in a solid sphere of deuterated polyethylene compressed to densities of 35 g/cc at temperatures of 2 keV and pressures of 40 Gbar

This paper describes an experiment that shock compresses the center of a solid deuterated polyethylene sphere, CD 2 , to densities of 35 g/cc and temperatures of 2 keV with corresponding pressure of 40 Gbar. The design employs a strong spherically converging shock launched through a solid ball of material using a Hohlraum radiation drive. As the shock coalesces at the center it produces a hot spot that we characterize by measuring the x-ray self-emission and 2.45 MeV neutrons emitted. Two-dimensional images and time-resolved measurements of the x rays emitted determine the size and time duration of the hot spot, leading to an estimated 2k eV electron temperature. The neutron time of flight spectrometer measures an average ion temperature of 1.06 ± 0.15 keV and neutron yield of 7.0 (±0.5) × 10 9 DD neutrons. Our new distribution function tool enables us to create a forward model of the experimental data based on 1D radiation-hydrodynamic simulations, leading to a better understanding of the plasma conditions that produce the measured neutrons and x rays. Furthermore, our simulations indicate that the x rays are produced in a short-lived hot-dense core over tens of picoseconds, whereas the neutron emission continues for about 200 ps, as the hot core starts to expand, thereby leading to a lower mean temperature of the plasma during neutron production. This finding is in agreement with the experimental data, and we therefore conclude that the forward-modeling is a useful tool for inferring the conditions of the hot spot in a laser-driven implosion during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Updates on MURAVES Project at Mt. Vesuvius

The MUon RAdiography of VESuvius (MURAVES) project aims to employ muography imaging techniques to investigate the internal structure of the summit of Mount Vesuvius, an active volcano located near Naples, Italy. This paper reports recent advancements in data analysis and simulation tools that significantly improve the quality and reliability of the experiment’s results. A new track selection method, referred to as the Golden Selection, has been developed to identify high-quality muon tracks by applying an improved χ 2 -based criterion. This method enhances the signal-to-background ratio and improves the resolution of the resulting muographic images. Moreover, the simulation framework has been upgraded through the integration of the MULDER (MUon simuLation for DEnsity Reconstruction) library, which consolidates the functionalities of previously used libraries into a single, unified platform. MULDER enables efficient and accurate modeling of muon flux variations induced by topographical features. A good agreement is observed between the simulated and measured muon flux maps, validating the effectiveness of the new analysis and simulation approaches.

Cosmic rays↗

Water Migration and Swelling in Engineered Barrier Materials for Radioactive Waste Disposal

Deep, underground repositories are needed to isolate radioactive waste from the biosphere. Because bentonite is an integral component of many multibarrier repository systems, information on the hydraulic behavior of bentonite is crucial for modeling the long-term viability of such systems. In this paper the hydraulic behavior of bentonite samples was analyzed as a function of aggregate size, and samples were subjected to hydrothermal treatments involving contact with NaCl, KCl, and deionized water. Neutron and X-ray imaging were used to quantify water sorption into packed bentonite samples and bentonite swelling into the water column. The distance between the original clay-water interface and the wetting front was determined as a function of time. Average water uptake exhibited a square-root-of-time dependence in freshly prepared samples, but more variable rates were observed for samples previously in contact with water. The radiography was supported by small-angle neutron scattering analysis and ultra-small-angle neutron scattering analysis of aggregate size distributions and by inelastic neutron scattering to understand the physicochemical environment of the sorbed water. Results showed that hydrothermal treatment with KCl had the greatest effect of increased water transport in the bentonite, possibly as a result of the interaction of K + with smectite layers in the clay.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A temperature profile diagnostic for radiation waves on OMEGA-60

Predicting and matching radiation wave propagation with computational models has proven difficult. Information provided by experiments studying radiation flow has been limited when only radiation breakout is measured. We have developed the COAX (co-axial) diagnostic platform to provide spatial temperature profiles of a radiation wave through low density foams as a more detailed constraint for simulations. COAX uses a standard, laser-driven OMEGA-60 halfraum to drive radiation down a titanium-laden silicon oxide foam. Point-projection X-ray absorption spectroscopy perpendicular to the radiation flow measures the spatial profile of titanium ionization. The spectroscopic measurement utilizes a broadband capsule backlighter. Imaging and streak spectroscopy are used to characterize the size and spectrum of this source. Radiography provides an additional constraint by capturing the developing shock as the radiation flow becomes subsonic. The DANTE diagnostic is used to measure the halfraum temperature. Here, we provide a spectroscopic analysis of COAX data to determine temperature, and we describe experimental sources of uncertainty. The temperature is obtained by comparison to multi-temperature synthetic spectra post-processed from radiation-hydrodynamics simulations. Quantitative comparison between data and synthetic spectra generated from temperature profiles at relevant simulation times enable determination of a peak temperature of 114 ± 8 eV at 265 ± 22.4 μm from the halfraum. This represents an improvement over the temperature uncertainties of previous radiation flow experiments. Further refinements to the spectroscopic analysis could achieve ±4 eV. The combination between space-resolved spectroscopy and radiography enables us to determine the distance from the halfraum of both the radiation front and the shock front at the time of measurement. For the example shown in this paper the radiation front position is 600–630 μm at 3.43 ± 0.16 ns and the shock front position is 633 μm at 3.3 ± 0.24 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Field Proton Radiography (Los Alamos LDRD Report)

Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Dimensional Particle-in-Cell Analysis of Mechanical Design Tolerances of the Scorpius Injector With Warp

Here, this article examines the mechanical design tolerances for the Scorpius injector using a 3-D particle-in-cell (PIC) code. In order to meet its objective as a high-fidelity, multipulse flash X-ray source, the accelerator has requirements for the electron beam in order to minimize the spot size of the beam focused onto a foil target to create high fluence X-rays at energies greater than 10 MeV. The requirements for alignment of the cathode, anode beam pipe, focusing solenoids, and transport solenoids specified using Trak and AMBER are independently verified using a 3-D electrostatic/magnetostatic model of the Scorpius injector, including transverse magnetic field errors that arise from mechanical alignment errors. It is predicted that the injector will meet the performance requirements for radiographic operation and has a design margin to correct for potentially unforeseen operating conditions.

42 ENGINEERING↗

The Viscosity and Atomic Structure of Volatile-Bearing Melilititic Melts at High Pressure and Temperature and the Transport of Deep Carbon

Understanding the viscosity of mantle-derived magmas is needed to model their migration mechanisms and ascent rate from the source rock to the surface. High pressure–temperature experimental data are now available on the viscosity of synthetic melts, pure carbonatitic to carbonate–silicate compositions, anhydrous basalts, dacites and rhyolites. However, the viscosity of volatile-bearing melilititic melts, among the most plausible carriers of deep carbon, has not been investigated. In this study, we experimentally determined the viscosity of synthetic liquids with ~31 and ~39 wt% SiO 2 , 1.60 and 1.42 wt% CO 2 and 5.7 and 1 wt% H 2 O, respectively, at pressures from 1 to 4.7 GPa and temperatures between 1265 and 1755 °C, using the falling-sphere technique combined with in situ X-ray radiography. Our results show viscosities between 0.1044 and 2.1221 Pa·s, with a clear dependence on temperature and SiO 2 content. The atomic structure of both melt compositions was also determined at high pressure and temperature, using in situ multi-angle energy-dispersive X-ray diffraction supported by ex situ microFTIR and microRaman spectroscopic measurements. Our results yield evidence that the T–T and T–O (T = Si,Al) interatomic distances of ultrabasic melts are higher than those for basaltic melts known from similar recent studies. Based on our experimental data, melilititic melts are expected to migrate at a rate ~from 2 to 57 km·yr -1 in the present-day or the Archaean mantle, respectively.

36 MATERIALS SCIENCE↗

Measurement of mix at the fuel–ablator interface in indirectly driven capsule implosions on the National Ignition Facility

The interface between the capsule ablator and fuel ice layer is susceptible to hydrodynamic instabilities. The subsequent mixing of hot ablator material into the ice reduces fuel compression at stagnation and is a candidate for reduced capsule performance. The ability to diagnose ice–ablator mix is critical to understanding and improving stability at this interface. Combining the crystal backlighter imager with the single line of sight camera on the National Ignition Facility (NIF) allows direct measurement of ice–ablator mix by providing multiple quasi-monochromatic radiographs of layered capsule implosions per experiment with high spatial (∼12 μm) and temporal (∼35 ps) resolution. The narrow bandwidth of this diagnostic platform allows radiography of the inner edge of the capsule limb close to stagnation without capsule self-emission contaminating the data and removes opacity uncertainties typically associated with the spectral content of the radiograph. Analysis of radiographic data via a parameterized forward-fitting Abel inversion technique provides measurements of the distribution of mix mass inwards from the ice–ablator interface. The sensitivity of this mix measurement technique was demonstrated by applying it to layered experiments in which the stability of the ice–ablator interface was expected to vary significantly. Additional experiments suggest that high-density carbon capsules that employ a buried-layer dopant profile suffer from mixing at the innermost doped–undoped interface. Data from these experiments suggest that opacity models used in hydrodynamic simulations of NIF experiments can potentially over-predict the opacity of doped capsules. LLNL-JRNL-850535-DRAFT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗