Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ellipticity dependence of high harmonic yield in intense laser field: case of s-valence electron

Having solved numerically the time-dependent Schrödinger equation, we have analysed the dependence of the high harmonic generation yield on the ellipticity of an intense laser field. For the case of a zero angular momentum of an initial state, it has been shown that the ellipticity dependence of the HHG yield is affected by the harmonic number. The numerical results are interpreted in the framework of our recently developed quasi-classical analytical model for HHG. In the quasi-classical approximation, the difference in the ellipticity dependence of the HHG yield for different harmonics is shown to be caused by the interference effects of quantum orbits. (extreme laser radiation: physics and fundamental applications)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acceleration of electrons by a laser pulse at its output onto an optical surface of the vacuum – transparent medium interface. Laser synchrotron

We consider the electron dynamics in the field of an electromagnetic wave produced at the vacuum – transparent medium interface upon reflection from the boundary, close to total internal reflection. The propagation velocity of a constant phase of the electromagnetic wave along the interface can vary from c/n to infinity (c is the speed of light in vacuum, and n is the refractive index of the medium at the interface). In this case, there emerge regions of positive and negative phases of the field with wavelengths, approximately equal to half the wavelength of the original laser beam, which can propagate at a speed close to that of light in vacuum. If a beam of relativistic electrons propagates along the surface, they can gain energy and accelerate, as well as radiate. With closed trajectories of electron motion, a laser synchrotron will be implemented as a result of many acceleration cycles. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limitations imposed by specimen phase gradients on the design of grating based x-ray phase contrast imaging systems

X-ray phase contrast imaging is a very promising technique that may lead to significant advancements in a variety of fields, perhaps most notably, medical imaging. The radiation physics group at University College London is currently developing an x-ray phase contrast imaging technique that works with laboratory x-ray sources. This system essentially measures the degree to which photons are refracted by regions of an imaged object. The amount of refraction that may be expected to be encountered in practice impacts strongly upon the design of the imaging system. In this paper, we derive an approximate expression between the properties of archetypal imaged objects encountered in practice and the resulting distribution of refracted photons. This is used to derive constraints governing the design of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Calibration to Predict the Concentrations of Impurities in Plutonium Oxide by Prompt Gamma Analysis Revision 2

This report documents the new PG calibration regression equation. These calibration equations incorporate new data that have become available since revision 1 of “A Calibration to Predict the Concentrations of Impurities in Plutonium Oxide by Prompt Gamma Analysis” was issued [3] The calibration equations are based on a weighted least squares (WLS) approach for the regression. The WLS method gives each data point its proper amount of influence over the parameter estimates. This gives two big advantages, more precise parameter estimates and better and more defensible estimates of uncertainties. The WLS approach makes sense both statistically and experimentally because the variances increase with concentration, and there are physical reasons that the higher measurements are less reliable and should be less influential. The new magnesium calibration includes a correction for sodium and separate calibration equation for items with and without chlorine. These additional calibration equations allow for better predictions and smaller uncertainties for sodium in materials with and without chlorine. Chlorine and sodium have separate equations for RICH materials. Again, these equations give better predictions and smaller uncertainties chlorine and sodium for RICH materials.

Instrumentation Related to Nuclear Science & Techn↗

Facility target insert shielding assessment

Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

Accelerator Design, Technology, and Operations↗

Advanced Semiconductor Dosimetry in Radiation Therapy

Modern radiation therapy is very conformal, resulting in a complexity of delivery that leads to many small radiation fields with steep dose gradients, increasing error probability. Quality assurance in delivery of such radiation fields is paramount and requires real time and high spatial resolution dosimetry. Semiconductor radiation detectors due to their small size, ability to operate in passive and active modes and easy real time multichannel readout satisfy many aspects of in vivo and in a phantom quality assurance in modern radiation therapy. Update on the recent developments and improvements in semiconductor radiation detectors and their application for quality assurance in radiation therapy, based mostly on the developments at the Centre for Medical Radiation Physics (CMRP), University of Wollongong, is presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

Valvular Abnormalities Detected by Echocardiography in 5-Year Survivors of Childhood Cancer: A Long-Term Follow-Up Study

Purpose: To determine the prevalence of valvular abnormalities after radiation therapy involving the heart region and/or treatment with anthracyclines and to identify associated risk factors in a large cohort of 5-year childhood cancer survivors (CCS). Methods and Materials: The study cohort consisted of all 626 eligible 5-year CCS diagnosed with childhood cancer in the Emma Children's Hospital/Academic Medical Center between 1966 and 1996 and treated with radiation therapy involving the heart region and/or anthracyclines. We determined the presence of valvular abnormalities according to echocardiograms. Physical radiation dose was converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Using multivariable logistic regression analyses, we examined the associations between cancer treatment and valvular abnormalities. Results: We identified 225 mainly mild echocardiographic valvular abnormalities in 169 of 545 CCS (31%) with a cardiac assessment (median follow-up time, 14.9 years [range, 5.1-36.8 years]; median attained age 22.0 years [range, 7.0-49.7 years]). Twenty-four CCS (4.4%) had 31 moderate or higher-graded abnormalities. Most common abnormalities were tricuspid valve disorders (n=119; 21.8%) and mitral valve disorders (n=73; 13.4%). The risk of valvular abnormalities was associated with increasing radiation dose (using EQD{sub 2}) involving the heart region (odds ratio 1.33 per 10 Gy) and the presence of congenital heart disease (odds ratio 3.43). We found no statistically significant evidence that anthracyclines increase the risk. Conclusions: Almost one-third of CCS treated with potentially cardiotoxic therapy had 1 or more asymptomatic, mostly mild valvular abnormalities after a median follow-up of nearly 15 years. The most important risk factors are higher EQD{sub 2} to the heart region and congenital heart disease. Studies with longer follow-up are necessary to investigate the clinical course of asymptomatic valvular abnormalities in CCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of roughness, deterministic and random errors in film thickness on the reflecting properties of aperiodic mirrors for the EUV range

By the example of three aperiodic multilayer Mo/Si mirrors (AMM) for the wavelength ranges 17–21 nm, 24–29 nm, and 28–33 nm we have studied numerically the effect of the linearly determinisctic and random fluctuations of the film thickness and the interlayer roughness on the spectral dependences of the reflection coefficient. The simulation results are used to solve the inverse problem of reconstructing the interlayer roughness and the thickness of individual films from the measured dependences of the extreme UV radiation reflection coefficients. It is shown that the 'asymmetry' of the boundaries affects the magnitude and slope of the reflection coefficient plateau. Random fluctuations of the film thickness with the variance of 1%–2% weakly influence the reflection characteristics of AMMs and allow reliable reconstruction of the thickness of individual films. The fluctuations with the variance 8%–10% allow the estimation of individual thicknesses, but the reflection curve in this case strongly differs from the desirable one. Larger fluctuations do not allow the reconstruction of the AMM structure. The basic criteria for high-quality AMM synthesis are formulated. (extreme laser radiation: physics and fundamental applications)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗