Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Integrated laser ablation-dropletProbe-mass spectrometry for absolute drug quantitation, metabolite detection, and distribution in tissue

Rationale: Spatially resolved and accurate quantitation of drug-related compounds in tissue is a much-needed capability in drug discovery research. In this work, application of an integrated laser ablation-dropletProbe-mass spectrometry surface sampling system (LADP-MS) is reported, which achieved absolute quantitation of propranolol measured from <500 × 500 μm thin tissue samples. Methods: Mouse liver and kidney thin tissue sections were coated with parylene C and analyzed for propranolol by a laser ablation/liquid extraction workflow. Non-coated adjacent sections were microdissected for validation and processed using standard bulk tissue extraction protocols. High-performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry was applied to detect the drug and its metabolites. Results: Absolute propranolol concentration in ~500 × 500 μm tissue regions measured by the two methods agreed within ±8% and had a relative standard deviation within ±17%. Quantitation down to ~400 × 400 μm tissue regions was shown, and this resolution was also used for automated mapping of propranolol and phase II hydroxypropranolol glucuronide metabolites in kidney tissue. Conclusions: This study exemplifies the capabilities of integrated laser ablation-dropletProbe-mass spectrometry (LADP-MS) for high resolution absolute drug quantitation analysis of thin tissue sections. This capability will be valuable for applications needing to quantitatively understand the spatial distribution of small molecules in tissue.

47 OTHER INSTRUMENTATION↗

Quantification of copepod gut content by differential length amplification quantitative PCR (dla-qPCR)

Quantification of feeding rates and selectivity of zooplankton is vital for understanding the mechanisms structuring marine ecosystems. However, methodological limitations have made many of these studies difficult. Recently, molecular based methods have demonstrated that DNA from prey species can be used to identify zooplankton gut contents, and further, quantitative gut content estimates by quantitative PCR (qPCR) assays targeted to the 18S rRNA gene have been used to estimate feeding rates in appendicularians and copepods. However, while standard single primer based qPCR assays were quantitative for the filter feeding appendicularian Oikopleura dioica, feeding rates were consistently underestimated in the copepod Calanus finmarchicus. In this study, we test the hypothesis that prey DNA is rapidly digested after ingestion by copepods and describe a qPCR-based assay, differential length amplification qPCR (dla-qPCR), to account for DNA digestion. The assay utilizes multiple primer sets that amplify different sized fragments of the prey 18S rRNA gene and, based on the differential amplification of these fragments, the degree of digestion is estimated and corrected for. Application of this approach to C. finmarchicus fed Rhodomonas marina significantly improved quantitative feeding estimates compared to standard qPCR. The development of dla-qPCR represents a significant advancement towards a quantitative method for assessing in situ copepod feeding rates without involving cultivation-based manipulation.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative estimation in Health Impact Assessment: Opportunities and challenges

Health Impact Assessment (HIA) considers multiple effects on health of policies, programs, plans and projects and thus requires the use of diverse analytic tools and sources of evidence. Quantitative estimation has desirable properties for the purpose of HIA but adequate tools for quantification exist currently for a limited number of health impacts and decision settings; furthermore, quantitative estimation generates thorny questions about the precision of estimates and the validity of methodological assumptions. In the United States, HIA has only recently emerged as an independent practice apart from integrated EIA, and this article aims to synthesize the experience with quantitative health effects estimation within that practice. We use examples identified through a scan of available identified instances of quantitative estimation in the U.S. practice experience to illustrate methods applied in different policy settings along with their strengths and limitations. We then discuss opportunity areas and practical considerations for the use of quantitative estimation in HIA.

54 ENVIRONMENTAL SCIENCES↗

Determination of the composition of Co-Pt thin films with quantitative electron-probe microanalysis

Quantitative electron-probe microanalysis (EPMA) with energy-dispersive (EDS) and wavelength-dispersive (WDS) X-ray spectroscopy was performed to determine the chemical composition of Co-Pt ferromagnetic thin films. The conventional 'bulk' EPMA approach was applied and tested in detail by using several analytical set-ups with different combinations of Co and Pt spectral lines, beam energies and quantitative matrix-correction programs. The analyses with dedicated, thin-film EPMA programs were also made for comparison. The results were critically examined in order to assess their reliability and accuracy. The commonly used EDS analyses showed significant scatter between the set-ups and generally suffered from a poor analytical sensitivity. In contrast, the quantitative WDS analyses were fully consistent and practically independent of the analytical set-up. With the optimized WDS a high analytical precision, an improved sensitivity and an ultimate quantitative accuracy of better than 1% relative were achieved. The results confirmed that by using WDS microanalysis at low beam energies and by measuring the low-energy Co-L{alpha} and Pt-M{alpha} X-rays we were able to obtain the most accurate and reliable, quantitative, compositional analyses of Co-Pt thin films with thicknesses down to {approx} 100 nm.

36 MATERIALS SCIENCE↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The incongruity of validating quantitative proteomics using western blots

Similar to the age-old reviewer request for quantitative PCR validation of RNA sequencing data, nearly every researcher using proteomics technologies has, at one time or another, been asked by a reviewer to provide “western blot validation” of their mass spectrometry-based protein abundance data. We believe this request demonstrates a lack of awareness amongst the plant biology community about the extraordinary improvements in cost, sensitivity and reliability the field of mass spectrometry-based proteomics has made in recent years. Here, in this study, as a group of experts in different domains of quantitative plant proteomics, we explain why “western blot validation” of quantitative proteomics data is both unnecessary and invalid. Furthermore, we invite our colleagues in the plant science community to update their perception of quantitative mass spectrometry as a sensitive and reliable method of protein identification and quantitation.

Mehta, Devang↗

Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake

Estimating organ residence times is an essential part of patient-specific dosimetry for radioimmunotherapy (RIT). Quantitative imaging methods for RIT are often evaluated using a single physical or simulated phantom but are intended to be applied clinically where there is variability in patient anatomy, biodistribution, and biokinetics. To provide a more relevant evaluation, the authors have thus developed a population of phantoms with realistic variations in these factors and applied it to the evaluation of quantitative imaging methods both to find the best method and to demonstrate the effects of these variations. Using whole body scans and SPECT/CT images, organ shapes and time-activity curves of 111In ibritumomab tiuxetan were measured in dosimetrically important organs in seven patients undergoing a high dose therapy regimen. Based on these measurements, we created a 3D NURBS-based cardiac-torso (NCAT)-based phantom population. SPECT and planar data at realistic count levels were then simulated using previously validated Monte Carlo simulation tools. The projections from the population were used to evaluate the accuracy and variation in accuracy of residence time estimation methods that used a time series of SPECT and planar scans. Quantitative SPECT (QSPECT) reconstruction methods were used that compensated for attenuation, scatter, and the collimator-detector response. Planar images were processed with a conventional (CPlanar) method that used geometric mean attenuation and triple-energy window scatter compensation and a quantitative planar (QPlanar) processing method that used model-based compensation for image degrading effects. Residence times were estimated from activity estimates made at each of five time points. The authors also evaluated hybrid methods that used CPlanar or QPlanar time-activity curves rescaled to the activity estimated from a single QSPECT image. The methods were evaluated in terms of mean relative error and standard deviation of the relative error in the residence time estimates taken over the phantom population. The mean errors in the residence time estimates over all the organs were <9.9% (pure QSPECT), <13.2% (pure QPLanar), <7.2% (hybrid QPlanar/QSPECT), <19.2% (hybrid CPlanar/QSPECT), and 7%-159% (pure CPlanar). The standard deviations of the errors for all the organs over all the phantoms were <9.9%, <11.9%, <10.8%, <22.0%, and <107.9% for the same methods, respectively. The processing methods differed both in terms of their average accuracy and the variation of the accuracy over the population of phantoms, thus demonstrating the importance of using a phantom population in evaluating quantitative imaging methods. Hybrid CPlanar/QSPECT provided improved accuracy compared to pure CPlanar and required the addition of only a single SPECT acquisition. The QPlanar or hybrid QPlanar/QSPECT methods had mean errors and standard deviations of errors that approached those of pure QSPECT while providing simplified image acquisition protocols, and thus may be more clinically practical.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-C-BRB-06: Translating NIH / NIBIB funding to clinical reality in quantitative diagnostic imaging

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation

Purpose: The aim of this study was to develop novel methods for photoacoustically determining the optical absorption coefficient of biological tissues using Monte Carlo (MC) simulation. Methods: In this study, the authors propose two quantitative photoacoustic tomography (PAT) methods for mapping the optical absorption coefficient. The reconstruction methods combine conventional PAT with MC simulation in a novel way to determine the optical absorption coefficient of biological tissues or organs. Specifically, the authors’ two schemes were theoretically and experimentally examined using simulations, tissue-mimicking phantoms, ex vivo, and in vivo tests. In particular, the authors explored these methods using several objects with different absorption contrasts embedded in turbid media and by using high-absorption media when the diffusion approximation was not effective at describing the photon transport. Results: The simulations and experimental tests showed that the reconstructions were quantitatively accurate in terms of the locations, sizes, and optical properties of the targets. The positions of the recovered targets were accessed by the property profiles, where the authors discovered that the off center error was less than 0.1 mm for the circular target. Meanwhile, the sizes and quantitative optical properties of the targets were quantified by estimating the full width half maximum of the optical absorption property. Interestingly, for the reconstructed sizes, the authors discovered that the errors ranged from 0 for relatively small-size targets to 26% for relatively large-size targets whereas for the recovered optical properties, the errors ranged from 0% to 12.5% for different cases. Conclusions: The authors found that their methods can quantitatively reconstruct absorbing objects of different sizes and optical contrasts even when the diffusion approximation is unable to accurately describe the photon propagation in biological tissues. In particular, their methods are able to resolve the intrinsic difficulties that occur when quantitative PAT is conducted by combining conventional PAT with the diffusion approximation or with radiation transport modeling.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP2-01: Quantitative Evaluation of PROPELLER DWI Using QIBA Diffusion Phantom

Purpose: The purpose of this study is to determine the quantitative variability of apparent diffusion coefficient (ADC) values when varying imaging parameters in a diffusion-weighted (DW) fast spin echo (FSE) sequence with Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) k-space trajectory. Methods: Using a 3T MRI scanner, a NIST traceable, quantitative magnetic resonance imaging (MRI) diffusion phantom (High Precision Devices, Inc, Boulder, Colorado) consisting of 13 vials filled with various concentrations of polymer polyvinylpyrrolidone (PVP) in aqueous solution was imaged with a standard Quantitative Imaging Biomarkers Alliance (QIBA) DWI spin echo, echo planar imaging (SE EPI) acquisition. The same phantom was then imaged with a DWI PROPELLER sequence at varying echo train lengths (ETL) of 8, 20, and 32, as well as b-values of 400, 900, and 2000. QIBA DWI phantom analysis software was used to generate ADC maps and create region of interests (ROIs) for quantitative measurements of each vial. Mean and standard deviations of the ROIs were compared. Results: The SE EPI sequence generated ADC values that showed very good agreement with the known ADC values of the phantom (r2 = 0.9995, slope = 1.0061). The ADC values measured from the PROPELLER sequences were inflated, but were highly correlated with an r2 range from 0.8754 to 0.9880. The PROPELLER sequence with an ETL=20 and b-value of 0 and 2000 showed the closest agreement (r2 = 0.9034, slope = 0.9880). Conclusion: The DW PROPELLER sequence is promising for quantitative evaluation of ADC values. A drawback of the PROPELLER sequence is the longer acquisition time. The 180° refocusing pulses may also cause the observed increase in ADC values compared to the standard SE EPI DW sequence. However, the FSE sequence offers an advantage with in-plane motion and geometric distortion which will be investigated in future studies.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion: Quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

Assigning Quantitative Function to Post-Translational Modifications Reveals Multiple Sites of Phosphorylation That Tune Yeast Pheromone Signaling Output

Cell signaling systems transmit information by post-­translationally modifying signaling proteins, often via phosphorylation. While thousands of sites of phosphorylation have been identified in proteomic studies, the vast majority of sites have no known function. Assigning functional roles to the catalog of uncharacterized phosphorylation sites is a key research challenge. Here we present a general approach to address this challenge and apply it to a prototypical signaling pathway, the pheromone response pathway in Saccharomyces cerevisiae. The pheromone pathway includes a mitogen activated protein kinase (MAPK) cascade activated by a G-­protein coupled receptor (GPCR). We used mass spectrometry-based proteomics to identify sites whose phosphorylation changed when the system was active, and evolutionary conservation to assign priority to a list of candidate MAPK regulatory sites. We made targeted alterations in those sites, and measured the effects of the mutations on pheromone pathway output in single cells. Our work identified six new sites that quantitatively tuned system output. We developed simple computational models to find system architectures that recapitulated the quantitative phenotypes of the mutants. Our results identify a number of regulated phosphorylation events that contribute to adjust the input-­output relationship of this model eukaryotic signaling system. We believe this combined approach constitutes a general means not only to reveal modification sites required to turn a pathway on and off, but also those required for more subtle quantitative effects that tune pathway output. Our results further suggest that relatively small quantitative influences from individual regulatory phosphorylation events endow signaling systems with plasticity that evolution may exploit to quantitatively tailor signaling outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Tools for Dissection of Hydrogen-Producing Metabolic Networks (Final Report)

During this project we have pioneered the development of integrated experimental-computational technologies for the quantitative dissection of metabolism in hydrogen and biofuel producing microorganisms (i.e. C. acetobutylicum and various cyanobacteria species). The application of these new methodologies resulted in many significant advances in the understanding of the metabolic networks and metabolism of these organisms, and has provided new strategies to enhance their hydrogen or biofuel producing capabilities. As an example, using mass spectrometry, isotope tracers, and quantitative flux-modeling we mapped the metabolic network structure in C. acetobutylicum. This resulted in a comprehensive and quantitative understanding of central carbon metabolism that could not have been obtained using genomic data alone. We discovered that biofuel production in this bacterium, which only occurs during stationary phase, requires a global remodeling of central metabolism (involving large changes in metabolite concentrations and fluxes) that has the effect of redirecting resources (carbon and reducing power) from biomass production into solvent production. This new holistic, quantitative understanding of metabolism is now being used as the basis for metabolic engineering strategies to improve solvent production in this bacterium. In another example, making use of newly developed technologies for monitoring hydrogen and NAD(P)H levels in vivo, we dissected the metabolic pathways for photobiological hydrogen production by cyanobacteria Cyanothece sp. This investigation led to the identification of multiple targets for improving hydrogen production. Importantly, the quantitative tools and approaches that we have developed are broadly applicable and we are now using them to investigate other important biofuel producers, such as cellulolytic bacteria.

08 HYDROGEN↗

A Quantitative Tool for Producing DNA-Based Diagnostic Arrays

The purpose of this project was to develop a precise, quantitative method to analyze oligodeoxynucleotides (ODNs) on an array to enable a systematic approach to quality control issues affecting DNA microarrays. Two types of ODN's were tested; ODN's formed by photolithography and ODN's printed onto microarrays. Initial work in Phase I, performed in conjunction with Affymetrix, Inc. who has a patent on a photolithographic in situ technique for creating DNA arrays, was very promising but did seem to indicate that the atomization process was not complete. Soon after Phase II work was under way, Affymetrix had further developed fluorescent methods and indicated they were no longer interested in our resonance ionization technique. This was communicated to the program manager and it was decided that the project would continue and be focused on printed ODNs. The method being tested is called SIRIS, Sputter-Initiated Resonance Ionization Spectroscopy. SIRIS has been shown to be a highly sensitive, selective, and quantitative tool for atomic species. This project was aimed at determining if an ODN could be labeled in such a way that SIRIS could be used to measure the label and thus provide quantitative measurements of the ODN on an array. One of the largest problems in this study has been developing a method that allows us to know the amount of an ODN on a surface independent of the SIRIS measurement. Even though we could accurately determine the amount of ODN deposited on a surface, the amount that actually attached to the surface is very difficult to measure (hence the need for a quantitative tool). A double-labeling procedure was developed in which 33P and Pt were both used to label ODNs. The radioactive 33P could be measured by a proportional counter that maps the counts in one dimension. This gave a good measurement of the amount of ODN remaining on a surface after immobilization and washing. A second label, Pt, was attached to guanine nucleotides in the ODN. Studies were conducted using this technique and comparing the results of the radioactive label vs SIRIS measurements of Pt as a function of ODN length and distance of the Pt label from the attachment end. The SIRIS signal was not proportional to the amount of oligo attached to the surface as determined by the decay of the 33P label. We intentionally tested conditions under which one might expect the atomization efficiency to change and we believe this is the problem. Different lengths of oligos, and different placement of the label in the oligo affected the final signal. This obviously makes use of SIRIS as a quantitative tool for oligonucleotides problematic except under highly controlled situations.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative analysis of bristle number in Drosophila mutants identifies genes involved in neural development

BACKGROUND: The identification of the function of all genes that contribute to specific biological processes and complex traits is one of the major challenges in the postgenomic era. One approach is to employ forward genetic screens in genetically tractable model organisms. In Drosophila melanogaster, P element-mediated insertional mutagenesis is a versatile tool for the dissection of molecular pathways, and there is an ongoing effort to tag every gene with a P element insertion. However, the vast majority of P element insertion lines are viable and fertile as homozygotes and do not exhibit obvious phenotypic defects, perhaps because of the tendency for P elements to insert 5' of transcription units. Quantitative genetic analysis of subtle effects of P element mutations that have been induced in an isogenic background may be a highly efficient method for functional genome annotation. RESULTS: Here, we have tested the efficacy of this strategy by assessing the extent to which screening for quantitative effects of P elements on sensory bristle number can identify genes affecting neural development. We find that such quantitative screens uncover an unusually large number of genes that are known to function in neural development, as well as genes with yet uncharacterized effects on neural development, and novel loci. CONCLUSIONS: Our findings establish the use of quantitative trait analysis for functional genome annotation through forward genetics. Similar analyses of quantitative effects of P element insertions will facilitate our understanding of the genes affecting many other complex traits in Drosophila.

Non-NASA Center↗

Preliminary Study for Development of Technical Basis of Quantitative Safety Goals for NPPs Operations in UAE

In this study, frameworks and methodologies for the development of technical basis of quantitative safety goals will be established. Most studies on the technical basis of the quantitative safety goals have been conducted after the commercial operations of NPPs. As a matter of fact, PSA insights are of much use for these kind of studies, hence it was not practical to provide the technical bases in a timely manner due to the unavailability of PSA studies at the moment. FANR has adopted the following mean values as quantitative safety goals: overall core damage frequency (CDF) < 10{sup -5}/ry and overall large release frequency (LRF) < 10{sup -6}/ry. Capabilities, framework, and methodologies to develop the technical basis of the quantitative safety goals in the UAE are established. Moreover, preliminary technical bases are developed in an early phase of NPP program in the UAE, which will lead to establishment, management, and update of the quantitative safety goals in a later phase.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the quantitative measurement of fracture toughness in high explosive and mock materials

Two approaches in measuring the fracture toughness of heterogeneous high explosives and their mocks are explored in this investigation. One is the global measurement according to the ASTM E 1820-06 standard, which is primarily developed for metallic materials to obtain quantitative measurement of parameters such as the stress intensity factor, the J-integral, and the crack-tip opening displacement (CTOD). The second approach is based on local measurements using digital image correlation (DIC). Detailed results and comparisons of the two strategies will be presented for the Mock 900-21, a mechanical simulant of the PBX 9501 high explosive. Cracking is the most dominant mechanical failure mechanism in high explosives (HE) and a key parameter for describing and predicting crack initiation and extension is the fracture toughness. Quantitative measurement of such material property poses challenges, and this is mainly because that the material is highly heterogeneous with a very complicated microstructure and the contrast of the mechanical properties of the constituents is also remarkably high. In this investigation, we explore two strategies in measuring the fracture toughness of heterogeneous high explosives and their mocks. The first approach is based on the global measurement according to the ASTM E 1820-06 standard, which is primarily developed for metallic materials to obtain quantitative measurement of parameters such as the stress intensity factor, the J-integral, and the crack-tip opening displacement (CTOD). However, there are difficulties in applying the ASTM standard on energetic solids that include identifying the moment of crack initiation and pinpointing exact crack length at each instant of time. The second approach is based on local measurements. We developed a technique for quantitatively identifying the location and extent of macroscopic cracks in heterogeneous high explosive and mock material. By combining such a technique with the displacement field measurement using digital image correlation (DIC), we can describe, in detail, the crack-opening displacement and crack-opening angle as function of crack length. These quantitative measurements are then combined with the fracture mechanics analysis for the determination of fracture toughness. While the ASTM standard imposes strict requirements on the specimen geometry, loading configuration, and the amount of crack growth, the strategy based on local measurement should be applicable to any sample shapes and loading conditions, thus makes it more suitable to energetic materials, where often the amount of material can be tested is the major constraint. Detailed results and comparisons of the two strategies will be presented for the Mock 900-21, a mechanical simulant of the PBX 9501 high explosive.

36 MATERIALS SCIENCE↗