Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Volume III. DUNE far detector technical coordination

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GNSS Installation at the ARM North Slope of Alaska Atmospheric Observatory Field Campaign Report

GRUAN, the Global Climate Observing System (GCOS) Reference Upper Air Network, is an international reference observing network of sites measuring essential climate variables above Earth's surface, designed to fill an important gap in the current global observing system. GRUAN’s objectives are to (1) provide long-term, high-quality climate records, (2) constrain and calibrate data from more spatially comprehensive global observing systems (including satellites and current radiosonde networks) and (3) fully characterize the properties of the atmospheric column.

54 ENVIRONMENTAL SCIENCES↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

Specific conductivity, pH, dissolved oxygen, water temperature and alkalinity in-situ data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes a time-series of field measurements from March to October 2021 in groundwater and surface water from the Slate River floodplain in Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data package includes 5 data files, one for each measured variable: specific conductivity, pH, dissolved oxygen, water temperature and alkalinity. All measurements were recorded in the field immediately after water sampling. Groundwater samples were extracted from a network of installed rhizons (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the floodplain. In addition to the data files, there is a terminology file explaining the terms used, a file level metadata file, and a sensor file with metadata about the sensors used.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

In-situ electrochemical and water quality data; Slate River and East River floodplains, Crested Butte, CO; May 2022-September 2022

This data package includes a time-series of field measurements from May to September 2022 in groundwater and surface water from the Slate River and East River floodplains in Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data package includes 5 data files, one for each measured variable: specific conductivity, pH, dissolved oxygen, water temperature and alkalinity. All measurements were recorded in the field immediately after water sampling. Groundwater samples were extracted from a network of installed rhizons (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the floodplain. In addition to the data files, there is a terminology file explaining the terms used, a file level metadata file, and a sensor file with metadata about the sensors used.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗

MRPP UO x Product Recover System Upgrade

The Material Recovery Pilot Plant (MRPP) produces U 3 O 8 /OU 3 product in powder form. This product must be collected, and cyclonic separators are an efficient method for collecting particles from an air stream. However, the M10 SafeVac currently installed at MRPP has design flaws and is failing. A new, semi-custom cyclonic separator from Hanningfield has been designed and ordered to replace the SafeVac. The Hanningfield model will be more efficient and better designed to suit the recovery at MRPP, increasing the quality of research produced at the plant. Unit cost is $118,000 with a 24 week lead time. It is expected to be operational by January 2025.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stream discharge and temperature data collected within the East and Taylor Watershed, Colorado for the Lawrence Berkeley National Laboratory Watershed Function Science Focus Area (water years 2019 to 2025)

This dataset contains stream discharge and temperature data for water years 2019 to 2025 from the East and Taylor Watersheds in Colorado, United States. This data was collected to understand hydrological processes occurring in the East River and Taylor River Watersheds, Colorado, which is part of the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area. Data includes instantaneous observed discharge using salt dilution and acoustic doppler velocimeter techniques, raw pressure transducer downloaded data, sub-hourly temperature as well as corrected water level and associated stream discharge and mean daily values. Notes on water level corrections, rating curve development and metadata provided. A rating curve is the translation of depth to streamflow. The rating curve can be used as a quantitative measure of the “quality of the data.” Data within this dataset is formatted using ESS-DIVE’s Hydrological Monitoring Reporting Format. This data package contains (1) a zip file (Stream_Discharge_Data_WY19-WY25.zip) containing stream discharge and temperature data organized by location; (2) an InstallationMethods file (InstallationMethods.csv) describing metadata about the installation; (3) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; (4) a data dictionary (dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (5) a locations metadata file (locations.csv); (6) and a sensor metadata file (sensors.csv). All data files are in non-proprietary formats (csv, png, or pdf formats). Please contact Rosemary Carroll, Curtis Beutler, or Austin Shirley for any support in accessing the files. Update on 2023-05-12: Additional data from WYs 2021 and 2022 were added. Additionally, the dataset was converted using ESS-DIVE’s Hydrological Monitoring Reporting Format. Data files were reformatted to match reporting format guidance, new metadata files were added, and files were converted from excel to CSV. Update on 2025-05-16: Additional data from WYs 2022 (for locations not previously included), 2023, and 2024 were added. An additional descriptive PDF (WFSFA_Streamflow_Hydrograph_Disclaimer.pdf) was added. Metadata files were updated to reflect the addition of new data and locations. Update on 2026-05-18: Additional data from WY 2025 were added, including a new location Upper Trail Creek (TR-TCG2). Metadata files were updated to reflect the addition of new data.

54 ENVIRONMENTAL SCIENCES↗

Specific conductivity, pH, dissolved oxygen, water temperature, alkalinity and sulfide in-situ data; Slate River floodplain, Crested Butte, CO; May 2020-October 2020

This data package includes a time-series of field measurements from May to October 2020 in groundwater and surface water from the Slate River floodplain in Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data packade includes 6 data files, one for each measured variable: specific conductivity, pH, dissolved oxygen, water temperature, alkalinity and sulfide. All measurements were recorded in the field immediately after water sampling. Groundwater samples were extracted from a network of installed rhizons (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the floodplain. In addition to the data files, there is a terminology file explaining the terms used, a file level metadata file, and a sensor file with metadata about the sensors used.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Scaling Equitable Finance

Driven by dramatic declines in up-front cost, the U.S. solar photovoltaics (PV) industry has taken off over the past decade, growing from 1 gigawatt of installed capacity in 2009 to 89 gigawatts in 2020—or enough capacity to power roughly 19 million homes. The industry is expected to double in size over just the next 5 years.1 Much of the growth has been driven by large, utility-scale projects that can produce 5 mega- watts or more of power—enough to power at least 1,000 homes. The cost of electricity produced by these projects has decreased by more than 70 percent since 2010. As of Q3 2020, development costs of large, util- ity-scale solar PV power plants were under $1 per watt, down by more than 70 percent from 2010.2 A robust array of investors has come forward to efficiently deliver capital to these kinds of utility-scale projects including large banks, insurance companies, pension funds, and others. But low- and moderate-income communities, including communities of color, are at risk of being left behind in the transition to clean energy. Mission- driven solar project developers and financial institu- tions have been working alongside energy justice advocates to open up solar access for these communi- ties, using strategies ranging from community solar, to solar installations on affordable multifamily housing, to distributed solar and storage programs, and more. Their goals go beyond simply generating more green energy to advancing social equity by: • empowering communities to control their energy future • stabilizing energy prices, saving money, and build- ing wealth for low-income families • creating quality jobs • improving health by reducing pollution • providing energy resilience for vulnerable communities Mission-driven actors are successfully deploying a wide variety of strategies to meet these goals, from helping low-income homeowners get solar—and some- times battery storage, to developing solar projects serv- ing affordable rental housing and community facilities, to building larger “shared solar” projects to which households from across the community can subscribe. However, the financing ecosystem does not work nearly as well for these “mission driven” solar proj- ects as it does for utility-scale projects. For home rooftop solar, even if low-income consumers have a home and suitable roof, they may fail to qualify for federal tax incentives, lack adequate credit to qualify for a loan—or the mission-driven lenders seeking to serve them may not be adequately capitalized to make long-term loans. For mission-driven commercial or community-scale projects, assembling nearly every component of the project capital stack—whether bridging early-stage costs, attracting tax credit equity investors, securing long-term debt, or coming up with sponsor equity and filling gaps—can present challenges. A variety of obstacles contribute to the scarcity of financing for low-income solar, including small project sizes, lack of developer balance sheet capacity, both real and perceived issues with credit risk, elevated technical assistance needs, and greater subsidy requirements to pursue goals such as deep energy affordability, climate resilience, or job creation. Still other obstacles are regulatory: for example, not all states allow community solar projects or Power Purchase Agreements, common strategies used for providing low-income solar—and the potential for regulations to shift over time creates risks that mission-driven projects can ill afford. This report synthesizes information garnered from 47 key informant interviews, four focus group discus- sions involving 60 stakeholders, and a review of the substantial existing literature on low-income solar finance to assess the current landscape of mission- driven solar development in the United States, examine the roles that community-based financial institutions could play, and recommend public invest- ments and policy changes that could help to scale the provision of equitable solar finance. Key recommen- dations for policymakers and funders in the renew- able energy and community development fields that emerge from this process include the following: • Help to capitalize and support community-based lenders to provide flexible, low-cost, and long- term financing to mission-driven solar projects— including providing guarantees or other forms of credit enhancement. • Provide federal support for equitable solar, including a grant-in-lieu-of-credits option for the Investment Tax Credit to improve access to this critical government subsidy. • Develop pools of government and philanthropic support that can complement financing from community-based lenders to complete the capi- tal stack for mission-driven projects, as well as to support education and technical assistance to both consumers and potential project sponsors. • Create a national Renewable Energy Credits pro- gram that includes social equity targets to provide a baseline of support for clean energy generation. • Change utility regulations to remove barriers to low-income solar projects; lower permitting costs; provide greater certainty for developers, consumers and owners; and measure progress toward equity in renewable energy policy implementation.

14 SOLAR ENERGY↗

Exploring the Potential of Factory Installed Solar + Storage for Homebuilding

In recent years, an increasing number of grid disruptions due to intense weather events, natural disasters, and high peak loads resulted in increased interest in energy-resilient homes. Solar + storage (S+S) as an energy resiliency solution can provide continuity, onsite generation, and backup power during critical events. This project explored factory-installed solar plus storage (FISS) to overcome first cost and installation barriers and bring this resiliency solution to scale for single-family affordable and market-rate homebuyers. Guided by the principles of Lean manufacturing, the team explored how factories building high-performance zero energy modular homes can incorporate S+S into their existing construction system while improving quality and productivity and reducing the costs of the resilient energy system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Membrane Cascade Design for Critical Mineral Recovery Through Logic-based Superstructure Optimization

Critical minerals and rare earth elements play an important role in our climate change initiatives, particularly in applications related with energy storage. Here, we use discrete optimization approaches to design a process for the recovery of Lithium and Cobalt from battery recycling, through membrane separation. Our contribution involves proposing a Generalized Disjunctive Programming (GDP) model for the optimal design of a multistage diafiltration cascade for Li-Co separation. By solving the resulting nonconvex mixed-integer nonlinear program model to global optimality, we investigated scalability and solution quality variations with changes in the number of stages and elements per stage. Results demonstrate the computational tractability of the nonlinear GDP formulation for design of membrane separation processes while opening the door for decom-position strategies for multicomponent separation cascades. Future work aims to extend the GDP formulation to account for stage installation and explore various decomposition techniques to enhance solution efficiency.

Ovalle, Daniel↗