Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pyrotechnic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Self-Rupturing Hermetic Valve

For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self-energizing and requires low force compared to current pyrotechnic-based burst disk hermetic valves. This is a novel design for producing a single-use, self-rupturing, hermetically sealed valve for isolation of pressurized gas and/or liquids. This design can also be applied for single-use disposable valves for chemical instruments. A welded foil diaphragm is fully supported by two mated surfaces that are machined to micron accuracies using EDM. To open the valve, one of the surfaces is moved relative to the other to (a) remove the support creating an unsupported diaphragm that ruptures due to over pressure, and/or (b) produce tension in the diaphragm and rupture it.

Tucker, Curtis E., Jr.↗

Evolution of titanium particle combustion in potassium perchlorate and air

Understanding titanium particle combustion processes is critical not only for characterizing existing pyrotechnic systems but also for creating new igniter designs. In order to characterize titanium particle combustion processes, morphologies, and temperatures, simultaneous spatially-resolved electric field holography and imaging pyrometry techniques were used to capture post-ignition data at up to 7 kHz. Due to the phase and thermal distortions present in the combustion cloud, traditional digital in-line holography techniques fail to capture accurate data. Here in this work, electric field holography techniques are used in order to cancel distortions and capture the three-dimensional spatial locations and diameters of the particles. In order to estimate the projected surface temperatures of the titanium particles, an imaging pyrometry method that ratios emission at 750 and 850 nm is utilized. Using these diagnostics, joint statistics are collected for particle size, morphology, velocity, and temperature. Results show that, early in the combustion process, the titanium particles are primarily oxidized by potassium perchlorate inside the igniter cup, resulting in projected surface temperatures near 3000 K. Later in the process, the particles interact with ambient air, resulting in lower surface temperatures around 2400 K and the formation of flame zones. These results are consistent with adiabatic flame temperature predictions as well as particle morphology observations of a titanium core with a TiO 2 surface. Late stage particle expansion, star fragmentation, and molten droplet breakup events are also observed using the time-resolved morphology and temperature diagnostics. These results illustrate the different stages of titanium particle combustion in pyrotechnic environments, which can be used to inform improvements in next-generation igniters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Henkin-McGill critical temperature test for explosives revisited: An overview of historical and modern method development

Many overarching standards, regulations, or other requirements necessitate that the critical temperature (T crit ) of an energetic material be known or estimate prior to operations such as heating. However, they rarely, if ever, provide a specific method for doing so. While other methods exist to calculate T crit , such as the Frank-Kamenetskii equation, computer simulation, etc., these cannot be readily utilized for energetics that are physical mixtures (i.e. most pyrotechnics) or materials where detailed material properties required for such calculations are lacking. Here, in this study, a COTS (commercial off-the-shelf) SBAT (Simulated Bulk Auto-ignition Test) apparatus is modified to perform Henkin cookoff tests. This creates a simple, efficient, and cost-effective solution to estimate required T crit values for energetic materials. After a historical overview of the evolution of the Henkin test, several common energetic materials (PETN, RDX, etc.) for which T crit has been readily calculated, and historical data is available, were analyzed for comparison and verification purposes. This was followed by a variety of pyrotechnic mixtures and other materials to where calculation methods cannot be readily used. The modified apparatus, as well as an updated sample shell sealing method, produced results that aligned well with historical data. It also produced reasonable T crit estimates for those materials where the Frank-Kamenetskii equation cannot be applied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Manifold Integrated Pyrovalve

The Manifold Integrated Pyrovalve (MI-PV) provides a state-of-the-art, low mass, low volume, normally-closed (NC) pyrotechnic isolation valve configuration which is optimized for small free-flier applications. Small scale free-flier (e.g. CubeSat) applications require high pressure fluid isolation valves with leak rates low enough to endure long pad stays, and often have severe mass and volume limitations. The MI-PV utilizes a unique configuration where the shear section and the pyrotechnic ram assembly (PRA) are installed directly into a ported gas manifold, allowing elimination of heavy fluid fittings and connections. This configuration can be readily scaled and adapted to the needs of other long duration missions.

valve pyrovalve pyrotechnic↗

Initiation system for low thrust motor igniter

A test program was carried out to demonstrate an igniter motor initiation system utilizing the bimetallic material Pyrofuze for a solid propellant rocket with controlled low rate of thrust buildup. The program consisted of a series of vacuum ignition tests using a slab burning window motor that simulated the principal initial ballistic parameters of the full scale igniter motor. A Pyrofuze/pyrotechnic igniter system was demonstrated that uses a relatively low electrical current level for initiation and that eliminates the necessity of a pyrotechnic squib, with its accompanying accidental firing hazards and the typical basket of pyrotechnic pellets. The Pyrofuze ignition system does require an initial constraining of the igniter motor nozzle flow, and at the low initiating electrical current level the ignition delay time of this system was found to be quite sensitive to factors affecting local heat generation or loss rates.

Strand, L. D.↗

A varistor technique to reduce the hazards of electrostatics to electroexplosive devices

Inherent to the design and construction of electroexplosive devices is a vulnerability to inadvertent initiation from electrostatic discharges. The small spacing (approx. 1 mm) between the bridgewire circuits and the body and between bridgewire circuits afford easy breakdown paths for electrostatic voltages. In some cases where metallic component pyrotechnic materials are loaded onto the bridgewire circuits the susceptability to inadvertant initiation is increased. An approach to solving this problem is reported based on the application of a new varistor (nonlinear resistor) material. Certain formulations of metal oxides normally have electrically nonconductive characteristics. However, at selective potentials they become conductive. By proper design and incorporation into electroexplosive devices a variety of breakdown potentials can be achieved. The breakdown potential of the varistor element can be adjusted to meet the requirements of the particular electroexplosive device. The varistor element can also be incorporated in an area isolated from the explosive or pyrotechnic material. Adaptation of this technique to a specific electroexplosive device and the resulting test data are presented.

Menichelli, V. J.↗

Long-life mission reliability for outer planet atmospheric entry probes

The results of a literature analysis on the effects of prolonged exposure to deep space environment on the properties of outer planet atmospheric entry probe components are presented. Materials considered included elastomers and plastics, pyrotechnic devices, thermal control components, metal springs and electronic components. The rates of degradation of each component were determined and extrapolation techniques were used to predict the effects of exposure for up to eight years to deep space. Pyrotechnic devices were aged under accelerated conditions to an equivalent of eight years in space and functionally tested. Results of the literature analysis of the selected components and testing of the devices indicated that no severe degradation should be expected during an eight year space mission.

Mccall, M. T.↗

Tapped-Hole Vent Path

Long helical vent path cools and releases hot pyrotechnical gas that exits along its spiraling threads. Current design uses 1/4-28 threads with outer diameter of stud reduced by 0.025 in. (0.62 mm). To open or close gassampler bottle, pyrotechnic charges on either one side or other of valve cylinder are actuated. Gases vented slowly over long path are cool enough to present no ignition hazard. Vent used to meter flow in refrigeration, pneumaticcontrol, and fluid-control systems by appropriately adjusting size and length of vent path.

Chandler, J. A.↗

Development of an ultra-low-shock separation nut

The technical problems encountered in the development of an advanced separation nut design are described. The nut is capable of sustaining a large preload and releasing that load with a low level of induced pyrotechnic shock, while demonstrating a tolerance for extremely high shock imposed by other pyrotechnic devices. The analysis of the separation nut was performed to acquire additional understanding of the phenomena affecting operation of the nut and to provide quantitative evaluation of design modification for aerospace applications.

Woebkenberg, W.↗

Explosively activated egress area

A lightweight, add on structure which employs linear shaped pyrotechnic charges to smoothly cut an airframe along an egress area periphery is provided. It compromises reaction surfaces attached to the exterior surface of the airframe's skin and is designed to restrict the skin deflection. That portion of the airframe within the egress area periphery is jettisoned. Retention surfaces and sealing walls are attached to the interior surface of the airframe's skin and are designed to shield the interior of the aircraft during detonation of the pyrotechnic charges.

Bement, L. J.↗

Toggle release

The invention relates to a pyrotechnic actuated release mechanism which is mechanically two fault tolerant for effecting release. It is particularly well suited for releasably connecting structures to be used in the space environment or in other aerospace applications. The device comprises a fastener plate and fastener body, each attachable to either one of a pair of structures to be joined. The fastener plate and the body are fastenable by a toggle supported at one end on the fastener plate and mounted for universal pivotal movement thereon. At its other end, which is received in a central opening in the fastener body and adapted for limited pivotal movement therein, the toggle is restrained by three retractable latching pins. Each pin is individually retractable by combustion of a pyrotechnic charge. While retraction of all three pins releases the toggle, the fastener is mechanically two fault tolerant since the failure of any single or pair of the latch pins to retract results in an asymmetrical loading on the toggle and its pivotal movement to effect a release. An annular bolt is mounted on the fastener plate as a support for the socket mounting of the toggle whereby its selective axial movement provides a means for pre-loading the toggle.

Graves, Thomas Joseph↗

Investigation of energy transfer in the ignition mechanism of a NASA standard initiator

The principal objective of the proposed research was to construct a detailed computer model of the NASA Standard Initiator (NSI). The NSI plays a critical role in initiating various pyrotechnic events in the National Space Transportation System and is also used in Shuttle payload applications. Several initiators failed when being tested at very low temperatures (4 to 20 K). During subsequent investigation an unacceptable high failure rate was found even at higher temperatures (100 to 150 K) but the precise cause of failure was not determined. The modelling work was undertaken to investigate reasons for failure and to predict the performance of alternate firing schemes. The work has shown that the most likely cause of failure at low temperature is poor thermal contact between the electrically heated bridgewire and the pyrotechnic charge. This problem may be masked if there is good thermal contact between the bridgewire and the alumina charge cup. The high thermal conductivity of alumina at cryogenic temperatures was overlooked in previous analyses, which assumed that the charge cup acted as a thermal insulator.

Varghese, Philip L.↗

Double swivel toggle release

A pyrotechnic actuated structural release device is disclosed which is mechanically two fault tolerant for release. The device comprises a fastener plate and fastener body each attachable to one of a pair of structures to be joined. The fastener plate and the fastener body are fastened by a dual swivel toggle member. The toggle member is supported at one end on the fastener plate and mounted for universal pivotal movement thereon. Its other end is received in a central opening in the fastener body, and has a universally mounted retainer ring member. The toggle member is restrained by three retractable latching pins symmetrically disposed in equiangular spacing about the axis of the toggle member and positionable in latching engagement with the retainer ring member on the toggle member. Each pin is retractable by a pyrotechnic charge, the expanding gases of which are applied to a pressure receiving face on the latch pins to effect retraction from the ring member. While retraction of all three pins releases the ring member, the fastener is mechanically two fault tolerant since the failure of any single one or pair of the latch pins to retract results in an asymmetrical loading on the ring member and its dual pivotal movement ensures a release.

King, Guy L.↗

Cartridge output testing - Methods to overcome closed-bomb shortcomings

Although the closed-bomb test has achieved virtually universal acceptance for measuring the output performance of pyrotechnic cartridges, there are serious shortcomings in its ability to quantify the performance of cartridges used as energy sources for pyrotechnic-activated mechanical devices. This paper presents several examples of cartridges (including the NASA Standard Initiator NSI) that successfully met closed-bomb performance requirements, but resulted in functional failures in mechanisms. To resolve these failures, test methods were developed to demonstrate a functional margin, based on comparing energy required to accomplish the function to energy deliverable by the cartridge.

Bement, Laurence J.↗

Laser-initiated ordnance for air-to-air missiles

McDonnell Douglas Missile Systems Company (MDMSC) has developed a laser ignition subsystem (LIS) for air-to-air missile applications. The MDMSC subsystem is designed to activate batteries, unlock fins, and sequence propulsion system events. The subsystem includes Pyro Zirconium Pump (PZP) lasers, mechanical Safe & Arm, fiber-optic distribution system, and optically activated pyrotechnic devices (initiators, detonators, and thermal batteries). The LIS design has incorporated testability features for the laser modules, drive electronics, fiber-optics, and pyrotechnics. Several of the LIS have been fabricated and have supported thermal battery testing, integral rocket ramjet testing, and have been integrated into integral rocket ramjet flight test vehicles as part of the flight control subsystem.

Sumpter, David R.↗

Proposed system safety design and test requirements for the microlaser ordnance system

Safety for pyrotechnic ignition systems is becoming a major concern for the military. In the past twenty years, stray electromagnetic fields have steadily increased during peacetime training missions and have dramatically increased during battlefield missions. Almost all of the ordnance systems in use today depend on an electrical bridgewire for ignition. Unfortunately, the bridgewire is the cause of the majority of failure modes. The common failure modes include the following: broken bridgewires; transient RF power, which induces bridgewire heating; and cold temperatures, which contracts the explosive mix away from the bridgewire. Finding solutions for these failure modes is driving the costs of pyrotechnic systems up. For example, analyses are performed to verify that the system in the environment will not see more energy than 20 dB below the 'No-fire' level. Range surveys are performed to determine the operational, storage, and transportation RF environments. Cryogenic tests are performed to verify the bridgewire to mix interface. System requirements call for 'last minute installation,' 'continuity checks after installation,' and rotating safety devices to 'interrupt the explosive train.' As an alternative, MDESC has developed a new approach based upon our enabling laser diode technology. We believe that Microlaser initiated ordnance offers a unique solution to the bridgewire safety concerns. For this presentation, we will address, from a system safety viewpoint, the safety design and the test requirements for a Microlaser ordnance system. We will also review how this system could be compliant to MIL-STD-1576 and DOD-83578A and the additional necessary requirements.

Stoltz, Barb A.↗

Burn rates of TiH2/KClO4/Viton and output testing of NASA SKD26100098-301 pressure cartridges

The burn rates of the pyrotechnic TiH2/KClO4/Viton with a mass ratio of 30/65/5 have been measured as a function of pressure in nitrogen up to 312 MPa(45 Kpsi). The burn rates were fit to R = a pn, with a = 2.055 cm/sec/MPan and n = 0.472 between 0.15 MPa (22 psi) and 21.6 MPa (3.13 Kpsi) and a = 4.38 cm/sec/MPan and n = 0.266 between 70 MPa (10.15 Kpsi) and 312 MPa (45.25 Kpsi). The decrease in slope at the higher pressures is attributed to a diffusion limited reaction. No acoustically driven flame instabilities or large conductive-to-convective burn transitions were observed. Solid reaction products were analyzed by x-ray diffraction and scanning electron microscopy (SEM). X-ray diffraction detected only TiO2 and KC1. SEM showed that the particle size of the reaction products increased as the nitrogen pressure increased. There were no anomalous characteristics of the burn of this pyrotechnic that could be interpreted as a cause of the o-ring blow-by problem in the forward shear bolt assembly. Three NASA SKD26100098-301 pressure cartridges were fired into a fixed volume vessel that was sealed with an O-ring. A maximum pressure of 181.7 MPa(26,350 psi) was reached in around 100 ,mu sec for two shots fired into a volume of 16.3 cm3(0.996 in3). A maximum pressure of 33,460 psi was reached for one shot fired into a volume of 9.55 cm3(0.583 in3). The O-ring burned through on one shot in the larger volume and leaked on the other two thereby simulating the effects of an O-ring leak. The results imply that the piston in the shear bolt assembly would receive a large impulse even if there was a leak in an O-ring seal.

Holy, John A.↗

Development of a high force thermal latch

This paper describes the preliminary development of a high force thermal latch (HFTL). The HFTL has one moving part which is restrained in the latched position by a low melting temperature or fusible metal alloy. When heated the fusible alloy flows to a receiving chamber and in so doing at first releases the tension load in the latch bolt and later releases the bolt itself. The HFTL can be used in place of pyrotechnically activated spacecraft release devices in those instances where the elimination of both pyrotechnic shock-loading and rapid strain-energy release take precedence over the near instantaneous release offered by ordnance initiated devices.

Nygren, William D.↗