Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Commercial submersible mixing pump for SRS tank waste removal - 15223

The Savannah River Site Tank Farms have 45 active underground waste tanks used to store and process nuclear waste materials. There are 4 different tank types, ranging in capacity from 2839 m{sup 3} to 4921m{sup 3} (750,000 to 1,300,000 gallons). Eighteen of the tanks are older style and do not meet all current federal standards for secondary containment. The older style tanks are the initial focus of waste removal efforts for tank closure and are referred to as closure tanks. Of the original 51 underground waste tanks, six of the original 24 older style tanks have completed waste removal and are filled with grout. The insoluble waste fraction that resides within most waste tanks at SRS requires vigorous agitation to suspend the solids within the waste liquid in order to transfer this material for eventual processing into glass filled canisters at the Defense Waste Processing Facility (DWPF). SRS suspends the solid waste by use of recirculating mixing pumps. Older style tanks generally have limited riser openings which will not support larger mixing pumps, since the riser access is typically 58.4 cm (23 inches) in diameter. Agitation for these tanks has been provided by four long shafted standard slurry pumps (SLP) powered by an above tank 112 kW (150 HP) electric motor. The pump shaft is lubricated and cooled in a pressurized water column that is sealed from the surrounding waste in the tank. Closure of four waste tanks has been accomplished utilizing long shafted pump technology combined with heel removal using multiple technologies. Newer style waste tanks at SRS have larger riser openings, allowing the processing of waste solids to be accomplished with four large diameter SLPs equipped with 224 kW (300 HP) motors. These tanks are used to process the waste from closure tanks for DWPF. In addition to the SLPs, a 224 kW (300 HP) submersible mixer pump (SMP) has also been developed and deployed within older style tanks. The SMPs are product cooled and product lubricated canned motor pumps designed to fit within available risers and have significant agitation capabilities to suspend waste solids. Waste removal and closure of two tanks has been accomplished with agitation provided by 3 SMPs installed within the tanks. In 2012, a team was assembled to investigate alternative solids removal technologies to support waste removal for closing tanks. The goal of the team was to find a more cost effective approach that could be used to replace the current mixing pump technology. This team was unable to identify an alternative technology outside of mixing pumps to support waste agitation and removal from SRS waste tanks. However, the team did identify a potentially lower cost mixing pump compared to the baseline SLPs and SMPs. Rather than using the traditional procurement using an engineering specification, the team proposed to seek commercially available submersible mixer pumps (CSMP) as alternatives to SLPs and SMPs. SLPs and SMPs have a high procurement cost and the actual cost of moving pumps between tanks has shown to be significantly higher than the original estimates that justified the reuse of SMPs and SLPs. The team recommended procurement of 'off-the-shelf' industry pumps which may be available for significant savings, but at an increased risk of failure and reduced operating life in the waste tank. The goal of the CSMP program is to obtain mixing pumps that could mix from bulk waste removal through tank closure and then be abandoned in place as part of tank closure. This paper will present the development, progress and relative advantages of the CSMP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Alternative Vacuum Pumps for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. The pumps would need to operate at lower rotational speeds to handle higher pressures and flow rates, which is best suited for Molecular Drag Pumps (MDP). To determine this, the vacuum pump characteristics must be determined for the MDP. This report details pump characteristics using an MDP backed by a Metal Bellows (Met-Bel) pump under static and flow conditions for various gases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-cost, high-performance nonevaporable getter pumps using nonevaporable getter pills

Nonevaporable getter (NEG) pumps are widely used for maintaining a clean ultrahigh vacuum (UHV) of ≤10{sup −8 }Pa because of their high pumping speeds for hydrogen (H{sub 2}) and active gases in the UHV region. In addition, they are oil free, evaporation free, sputtering free, sublimation free, magnetic field free, vibration free, economical, compact, lightweight, and energy saving. In the present paper, the authors report a new NEG pump which is composed of commercial 60 NEG pills (ϕ10 × 3 mm; 70 wt. % Zr, 24.6 wt. % V, and 5.4 wt. % Fe), titanium parts, a DN 40 conflat flange, and a tantalum heater. The NEG pills are vertically and radially aligned around the heater to maximize the effective area for pumping. After activation at 400 °C for 30 min, the pumping speeds of the NEG pump were measured with the orifice method. Pumping speeds of 140–130, 200–140, 190–130, and 35–17 l/s were estimated for H{sub 2}, CO, CO{sub 2}, and N{sub 2} gasses, respectively, in a pumped-quantity range of 0.01–0.1 Pa l. Since the NEG pump is composed of a heating unit and a NEG module, the pumping speeds can be improved by increasing the number of NEG modules. These NEG pumps are favorable alternatives to sputtering ion pumps or titanium sublimation pumps.

36 MATERIALS SCIENCE↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Controls of Wellbore Flow Regimes on Pump Effluent Composition

Where well water and formation water are compositionally different or heterogeneous, pump effluent composition will vary due to partial mixing and transport induced by pumping. Investigating influences of purging and sampling methodology on composition variability requires quantification of wellbore flow regimes and mixing. As a basis for this quantification, analytical models simulating Poiseuille flow were developed to calculate flow paths and travel times. Finite element modeling was used to incorporate influences of mixing. Parabolic velocity distributions within the screened interval accelerate with cumulative inflow approaching the pump intake while an annulus of inflowing formation water contracts uniformly to displace an axial cylinder of pre-pumping well water as pumping proceeds. Increased dispersive mixing forms a more diffuse formation water annulus and the contribution of formation water to pump effluent increases more rapidly. Models incorporating viscous flow and diffusion scale mixing show that initially pump effluent is predominantly pre-pumping well water and compositions vary most rapidly. After two screen volumes of pumping, 94% of pump effluent is inflowing formation water. Where the composition of formation water and pre-pumping well water are likely to be similar, pump effluent compositions will not vary significantly and may be collected during early purging or with passive sampling. However, where these compositions are expected to be considerably different or heterogeneous, compositions would be most variable during early pumping, that is, when samples are collected during low-flow sampling. Purging of two screen volumes would be required to stabilize the content and collect a sample consisting of 94% formation water.

58 GEOSCIENCES↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Entrainment of Juvenile and Adult American Shad at a Pumped Storage Facility

The American Shad Alosa sapidissima has been targeted for restoration to the upper Susquehanna River, and entrainment losses at hydroelectric facilities on the river, including the Muddy Run Pumped Storage Facility, are of concern for the potential growth of the American Shad population. Based on the integration of pumping volume, time of entrainment, and literature–reported diel emigration of juvenile American Shad, the entrainment rate (N = 145; 53 exposed to pumping) was estimated at 3.5%. The entrainment rate for adults (N = 507) was estimated at 0.3–3.9%. Using multistate mark–recapture models, the estimated entrainment probabilities (Ψ) of radio–tagged juveniles were higher during periods of extended pumping (>1 h; Ψ = 0.093; 95% confidence interval [CI] = 0.054–0.156) than at periods of no pumping or short–duration pumping (<1 h; Ψ < 0.0001; 95% CI = 0.0–0.001); the high extended pumping occurred between 2300 and 0600 hours. Entrainment probabilities for adults were low (Ψ < 0.02); the highest probability occurred for fish detected downstream of the intake during the peak portion of the run (Ψ = 0.015; 95% CI = 0.004–0.047). Entrainment probability for most adult fish did not differ from zero. The low values of Ψ for both life stages were attributed to (1) the deep location of the intake (intake ceiling >11.7 m below the water surface), (2) the surface orientation of American Shad (upper 3.1 m), (3) the low overlap between high–volume pumping and peak emigration/migration times, (4) the pumping volume relative to prevailing river flows, and (5) the prolonged, robust swimming speed of American Shad, particularly that of adults (>2.2 m/s), which exceeded the intake velocity (0.2–0.9 m/s). Entrainment of juveniles increased with co–occurrence of low incoming river flows, high pumping volume, and peak emigration times. Furthermore, quantification of migratory species’ entrainment at pumped storage facilities requires integration of diel migration/emigration times with the frequency, timing, and duration of pumping volume.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗

Electroosmotic pump unit and assembly

An electroosmotic pump unit includes at least a first pump element, at least a second pump element, and an electrode. Each pump element includes a tube, an electrically grounded fluid inlet, a fluid outlet electrically coupled to the electrode, and a porous monolith immobilized in the tube and having open pores having net surface charges. When the electrode applies a voltage across the monoliths, a fluid supplied to the first pump element flows through the pump elements in a direction from a fluid inlet of the first pump element toward a fluid outlet of the second pump element. A plurality of electroosmotic pump units may be connected in series in a pump assembly. The electroosmotic pump unit, or pump assembly, may be connected to an apparatus such as a HPLC.

42 ENGINEERING↗

Managing an Aging Pump-and-Treat Groundwater Remediation System at the Fernald Preserve - 19557

The Fernald Preserve, Ohio, Site underwent restoration and remediation under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). With the exception of the Great Miami Aquifer, the CERCLA remediation was declared physically complete on October 29, 2006, and the site was turned over to the US Department of Energy Office of Legacy Management for long-term care and maintenance. The Record of Decision under CERCLA specifies a concentration-based cleanup that requires the extraction and treatment of Great Miami Aquifer groundwater above Final Remediation Levels (FRLs) until the full, beneficial use potential of the aquifer is achieved, including use as a drinking water source. The area of the aquifer targeted for remediation is 126.5 hectares (312.70 acres). The groundwater pumping remediation was designed by modeling cleanup with the Variable Saturated Analysis Model in 3 Dimensions (VAM-3D) modeling code, developed by Hydrogeologic Inc. The original design called for 23 extraction wells operating at 379 liters per minute (lpm) (100 gallons per minute [gpm]) to 1135 lpm (300 gpm) each for a system total of 18,073 lpm (4775 gpm). In 2014, the system was optimized down to 20 extraction wells operating at 379 to 1893 lpm each for a system total of 19,180 lpm (5075 gpm). To date, pumping has been an effective remediation technology for the aquifer. At the end of 2017, the area of the aquifer remaining above FRLs was down to 38.2 hectares (94.4 acres). From August 1993 through December 2017 (24 years), 6235 kilograms (kg) (13,733 pounds) of uranium were removed from the aquifer by the pumping of 1.74 x 10{sup 11} liters (46.2 billion gallons) of water. Since 2010, treatment of groundwater to achieve regulatory discharge limits at the Great Miami River has not been needed on a routine basis. The ongoing remediation is now essentially a pumping operation, and this water does not require treatment. Metrics reported in the annual Site Environmental Report for the groundwater remediation indicate that, based on the model-predicted estimate of the mass of uranium that needs to be removed from the aquifer to achieve a concentration-based cleanup, the cleanup is approximately 86% - 87% complete. Current model predictions indicate that pumping will need to continue an additional 16 years (until 2035) in some of the wells. During the additional 16 years, it is estimated that approximately 1012 kg (2231 pounds) of uranium will be removed from the aquifer. System pumping rates are designed to decrease over the course of the remaining 16 years, dropping down to a system total of 11,638 lpm (3075 gpm) in 2022 and a system total of 4163 lpm (1100 gpm) in 2033. Even with the designed decreases in pumping rates, it is estimated that approximately 1 x 10{sup 11} liters (26.6 billion gallons) of water will be pumped from the aquifer to remove 1012 kg (2231 pounds) of uranium. This indicates that the remaining 16 years of operation will be much less efficient than the first 24 years. Decreasing efficiency is common for pumping operations. The worst-case scenario is that decreasing concentration trends stabilize above the cleanup FRLs and remediation goals are never achieved. Performance assessments of the pumping remedy will need to be routinely conducted to determine if pumping should be discontinued, if it should be continued but optimized, or if the pumping technology can be supplemented with a different technology that will improve the outcome of the remediation and make the operation more efficient and successful. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A miniature jet pump for slurries

Here, this work reports on the design and performance of a jet pump system to pump slurries. The jet pump uses a high-velocity water jet to entrain and pump the slurry. This pumping action requires no valves and does not use moving solid parts. Hence, the system can be readily sealed, and the pumping action creates no observable mechanical damage to slurry particles. We tested carbon black beads suspended in water at concentrations of 0.0, 0.2, and 2.0 wt% at primary jet flow rates of 50 and 100 mL/min. Our measurements show an approximately linear decrease in entrainment ratio (slurry-to-jet flow rate) and absolute slurry flow rate with increasing adverse (load) pressure difference. The entrainment ratio is a strong function of the absolute jet flow rate. Pump performance was insensitive to slurry composition. Micron-resolution particle image velocimetry (micro-PIV) revealed qualitative changes in the pump’s internal flow due to changes in absolute jet flow rate, including evidence of the suppression of a vortex at higher flow rates. These findings establish key operational parameters for the jet pump and highlight its potential in a variety of slurry flow pumping applications. The pump is particularly suited for flow electrode slurries (e.g. as used for energy storage and water treatment) as it maintains particle integrity and can be used with standard tubing, tube fittings, and sealing methods.

42 ENGINEERING↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

A NORMETEX MODEL 15 M3/HR WATER VAPOR PUMPING TEST

Tests were performed using a Model 15 m{sup 3}/hr Normetex vacuum pump to determine if pump performance degraded after pumping a humid gas stream. An air feed stream containing 30% water vapor was introduced into the pump for 365 hours with the outlet pressure of the pump near the condensation conditions of the water. Performance of the pump was tested before and after the water vapor pumping test and indicated no loss in performance of the pump. The pump also appeared to tolerate small amounts of condensed water of short duration without increased noise, vibration, or other adverse indications. The Normetex pump was backed by a dual-head diaphragm pump which was affected by the condensation of water and produced some drift in operating conditions during the test.

42 ENGINEERING↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗