Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Customizable wave tailoring nonlinear materials enabled by bilevel inverse design

Abstract Passive wave transformation via nonlinearity is ubiquitous in settings from acoustics to optics and electromagnetics. It is well known that different nonlinearities yield different effects on propagating signals, which raises the question of “what precise nonlinearity is the best for a given wave tailoring application?” In this work, considering a one-dimensional spring-mass chain connected by polynomial springs (a variant of the Fermi-Pasta-Ulam-Tsingou system), we introduce a bilevel inverse design method which couples the shape optimization of structures for tailored constitutive responses with reduced-order nonlinear dynamical inverse design. We apply it to two qualitatively distinct problems—minimization of peak transmitted kinetic energy from impact, and pulse shape transformation—demonstrating our method’s breadth of applicability. For the impact problem, we obtain two fundamental insights. First, small differences in nonlinearity can drastically change the dynamic response of the system, from severely under- to outperforming a comparative linear system. Second, the oft-used strategy of impact mitigation via “energy locking” bistability can be significantly outperformed by our optimal nonlinearity. We validate this case with impact experiments and find excellent agreement. This study establishes a framework for broader passive nonlinear mechanical wave tailoring material design, with applications to computing, signal processing, shock mitigation, and autonomous materials.

Science & Technology - Other Topics↗

A liquid hydrogen tube moderator arrangement for SNS second target station

Liquid hydrogen filled tubes arranged in a triangular shape surrounded by light-water premoderators were investigated as cold moderators coupled to a neutron production zone of a tungsten target fed by a 1.3 GeV proton beam in a short-pulse mode. A moderator concept optimized for the tube length, premoderator thickness, and target position was found to deliver the highest pulse-integrated neutron brightness suitable to send cold neutron beams for neutron scattering instrumentation geared toward medium resolution and small samples. Reducing the tube diameter from 50 to 10 mm boosts the cold neutron brightness (E < 10 meV) by a factor of 2.25, also with enhancements seen by downsizing the height of cylindrical moderators in earlier studies. Attempts were made to characterize this novel moderator system with regard to pulse shapes, local brightness distribution, and angular distribution of emission at the neutron emission port.

Gallmeier, Franz X. (ORCID:0000000171500764)↗

Leakage Reduces Device Coherence Demands for Pulse-Level Molecular Simulations

Quantum simulation on noisy intermediate-scale quantum devices is severely limited by short qubit coherence times. A variational pulse-shaping algorithm known as ctrl-VQE was recently proposed to address this issue by eliminating the need for parameterized quantum circuits, which lead to long state preparation times. Here, in this study, we find the fastest possible pulses that prepare target molecular wave functions for a given device Hamiltonian describing coupled transmon qubits using simulations. We find that the resulting time-optimal pulses develop a bang-bang form consistent with Pontryagin’s maximum principle. We further investigate how the minimal state preparation time is impacted by the number of energy levels active in the transmon simulations. We find that leakage outside the computational subspace (something that is usually considered problematic) speeds up the state preparation, further reducing device coherence-time demands. Our analysis reveals that this speedup is due to both an enlarged solution space of target wave functions and the appearance of additional channels connecting initial and target states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bandwidth extension and conversion efficiency improvements beyond phase matching limitations using cavity-enhanced OPCPA

The conversion efficiency and phase matching bandwidth of ultrafast optical parametric amplification (OPA) are constrained by the dispersion and nonlinear coefficient of the employed crystal as well as pulse shaping effects. In our work we show that an enhancement cavity resonant with the pump seeded at the full repetition rate of the pump laser can automatically reshape the small-signal gain in optical parametric chirped-pulse amplification (OPCPA) to achieve close-to-optimal operation. This new method termed cavity-enhanced OPCPA or C-OPCPA significantly increases both the gain bandwidth and the conversion efficiency, in addition to boosting gain for high-repetition-rate amplification. The goal in C-OPCPA is to arrive at a condition of impedance matching at all temporal coordinates, such that, in the absence of linear losses, all the incident pump power is dissipated in the nonlinear loss element, i.e., converted to signal and idler. The use of a low finesse enhancement cavity resonant with a low average power (<1W) and a high repetition rate (78MHz) pump source is shown to achieve more than 50% conversion efficiency into signal and idler from the coupled pump in an optical parametric process, whereas an equivalent amount of pump power in a single-pass configuration leads to negligible conversion. Additionally, the gain bandwidth is extended by a factor of 3-4 beyond the phase-matching limit. Our empirical observations are corroborated by a numerical analysis of depletion optimizing the single-pass case, which assesses the underlying impedance matching that is responsible for the observed performance improvements.

47 OTHER INSTRUMENTATION↗

Power Flow Spectroscopy Diagnostics & Platform Development at the Z Pulsed Power Facility

Large pulsed power accelerators deliver multi-MJ pulses of electrical energy to a variety of high energy density (HED) physics experiments that support stockpile science programs. Understanding the plasma formation mechanisms and resulting electrical power transport (or "power flow") in the vacuum magnetically insulated transmission lines (MITLs) is an important area of ongoing research, and could provide a means to improve the performance of today's pulsed power accelerators while improving confidence in the design options for next-generation pulsed power concepts. Power flow science has been studied for decades, but these studies have not provided a predictive understanding of plasma formation and expansion in MITL systems. Several recent factors in pulsed power system design have generated a renewed (and urgent) interest in developing validated, multi-physics power flow engineering models with increased scrutiny and understanding. Examples of these factors include (i) the use of high inductance experimental configurations that could increase current "loss", (ii) interest in long-pulse applications that require predictable pulse shapes, and (iii) the desire to develop a deeper understanding of how current loss phenomena scale to larger accelerator configurations. This work is directed to support the validation of multi-physics power flow engineering models required to realize pulsed power systems for the NNSA mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Single and Double Shell Ignition Targets for the National Ignition Facility at 527 nm

Converting and using the National Ignition Facility (NIF) to deliver 527 nm light instead of its current 351 nm would allow the laser to deliver more energy and power to ignition targets. We update previous 527 nm target design work to reflect more contemporary target designs using high-density carbon capsules and low density helium gas filled Hohlraums. We extend single shell capsule designs based on current experimental results to higher energy and power and also explore double shell capsules, both driven by green light. These studies were completed using detailed pulse shapes found for targets that converged with acceptable 2D implosion symmetries and then used the Lava Lamp II code to confirm their feasibility at NIF. A 1.2× dimensional scaleup of one tuned NIF target at the limit of its current 351 nm capabilities and shot 170827 uses 3.3 MJ, at the limit of the current NIF's 527 nm capability. With the less-structured pulse of a double shell target, 3.7 MJ could be delivered by the laser. Our LPI calculations do not preclude operation at 527 nm, particularly for low fill Hohlraums, and suggest that the stimulated Raman backscatter may be no worse than the small quantities seen in 170827; stimulated forward Raman scattering may be present. If Stimulated Brillouin Scattering is too great, the much greater laser bandwidth available at 527 nm could be used to decrease backscatter. These larger targets with higher energy and power may offer a better chance of achieving ignition with only modest changes to the NIF laser.

43 PARTICLE ACCELERATORS↗

High-energy, low-jitter, narrowband ps probe laser for kHz-rate fs/ps coherent anti-Stokes Raman scattering

Hybrid fs/ps coherent anti-Stokes Raman scattering (CARS) thermometry often utilizes ps probe pulses derived from pulse shaping or spectrally filtering the primary laser source or by synchronization with a low repetition rate external laser. This results in limited energy, spectral resolution, and/or repetition rate of the ps probe. In this work, a master-oscillator power-amplifier (MOPA) laser was synchronized to the oscillator of a Ti:sapphire regenerative amplifier to achieve high-energy (600 µJ), narrowband (58 ps) probe pulses at kHz repetition rates. Furthermore, temporal filtering allows the pulse characteristics to be adjusted for each application. At 25 Torr, relevant to high-speed flows, the kHz-rate MOPA system generated signal-to-noise ratios 3× higher in nitrogen and had improved precision relative to a 10 ps probe derived from spectral filtering and the power-amplifier. The MOPA system also enabled single-shot ro-vibrational hybrid fs/ps CARS thermometry in 650 K heated air.

47 OTHER INSTRUMENTATION↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

The DREAM Endstation at the Linac Coherent Light Source

Free-electron lasers (FEL), with their ultrashort pulses, ultrahigh intensities, and high repetition rates at short wavelength, have provided new approaches to Atomic and Molecular Optical Science. One such approach is following the birth of a photo electron to observe ion dynamics on an ultrafast timescale. Such an approach presents the opportunity to decipher the photon-initiated structural dynamics of an isolated atomic and molecular species. It is a fundamental step towards understanding single- and non-linear multi-photon processes and coherent electron dynamics in atoms and molecules, ultimately leading to coherent control following FEL research breakthroughs in pulse shaping and polarization control. A key aspect for exploring photoinduced quantum phenomena is visualizing the collective motion of electrons and nuclei in a single reaction process, as dynamics in atoms/ions proceed at femtosecond (10 –15 s) timescales while electronic dynamics take place in the attosecond timescale (10 –18 s). Here, we report on the design of a Dynamic Reaction Microscope (DREAM) endstation located at the second interaction point of the Time-Resolved Molecular and Optical (TMO) instrument at the Linac Coherent Light Source (LCLS) capable of following the photon–matter interactions by detecting ions and electrons in coincidence. The DREAM endstation takes advantage of the pulse properties and high repetition rate of LCLS-II to perform gas-phase soft X-ray experiments in a wide spectrum of scientific domains. With its design ability to detect multi-ions and electrons in coincidence while operating in step with the high repetition rate of LCLS-II, the DREAM endstation takes advantage of the inherent momentum conservation of reaction product ions with participating electrons to reconstruct the original X-ray photon–matter interactions. In this report, we outline in detail the design of the DREAM endstation and its functionality, with scientific opportunities enabled by this state-of-the-art instrument.

47 OTHER INSTRUMENTATION↗

“Beam à la carte”: Laser heater shaping for attosecond pulses in a multiplexed x-ray free-electron laser

Electron beam shaping allows the control of the temporal properties of x-ray free-electron laser pulses from femtosecond to attosecond timescales. Here, we demonstrate the use of a laser heater to shape electron bunches and enable the generation of attosecond x-ray pulses. We demonstrate that this method can be applied in a selective way, shaping a targeted subset of bunches while leaving the remaining bunches unchanged. This experiment enables the delivery of shaped x-ray pulses to multiple undulator beamlines, with pulse properties tailored to specialized scientific applications.

43 PARTICLE ACCELERATORS↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Performance of the Solid-State Laser Trigger System for HERMES III

The HERMES III accelerator is an 18-20 MeV linear induction accelerator constructed at Sandia National Laboratories in the late 1980s and which continues operation to this day. As part of recent modernization efforts, the laser triggering system on the accelerator has been replaced with a newly designed solid-state system. This system consists of ten Nd:YAG lasers, each having a nominal output energy of 40-45 mJ at a wavelength of 266 nm. The beam from each laser is split such that it triggers two of the Rimfire gas switches on the accelerator. Compared to the previous laser triggering system, this arrangement makes it possible to more readily tailor the final output pulse shape, and overall reliability for the accelerator's operation with these new lasers has increased. The design of this new laser triggering system is presented in this paper, along with details pertaining to the energy budgeting, optical beam paths, and electrical triggering of the lasers. Initial operational data from the HERMES III accelerator using this new triggering system is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Dopant Optimization of Donors in Semiconductor Opening Switches to Eliminate Prepulse

Semiconductor opening switches are solid-state devices capable of delivering nanosecond, hundreds of kilovolts pulses by interrupting kiloamps of current. The interruption of the current occurs in a moderately doped p-region when a high electric field region (HFR) is formed. The HFR occurs because the reverse pumping current cannot be supported by the saturation velocity and majority carrier concentration of the doping level. However, the donor profile also significantly affects the pulse performance. A secondary prepulse occurs if a secondary HFR is formed at the interface of the background n-doping and N+ doping (X n ) . By moving the location of X n deeper into the diode, the effect of the prepulse is reduced. This article investigates the effect of the donor doping profile on the performance metrics of semiconductor opening switches through technology computer-aided design (TCAD) simulations and experimental results. Through a SILVACO TCAD optimization, we designed a P + /p/n - base/n/N + where the intersection of the moderate p-region and intrinsic n-base region (X p ) is at 160 μm and X n is at 220 μm. This profile is fabricated via silicon epitaxy. Experimentally, it is shown that a deep X n (220 μm) compared with a shallow X n (300 μm) reduces the rise time by >5× . In addition, the magnitude of current density during interruption affects the prepulse foot and pulse shape. At lower current densities without the graded donor profile, high peak voltages are not achieved. Comparing the experimental results to the TCAD simulations shows that the model is predictive under high-current densities in the semiconductor opening switch (SOS) regime.

nanosecond pulse power↗

The Data Acquisition System for Phase-III of the BeEST Experiment

The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of 7 Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. Here, we present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delivering laser performance conditions to enable fusion ignition, and beyond at the National Ignition Facility

On December 5th, 2022, controlled fusion ignition was demonstrated for the first time at the National Ignition Facility (NIF), a major achievement in the field of Inertial Confinement Fusion (ICF) requiring a multi-decadal effort involving broad national and international collaborations. To drive the fusion ignition reaction with the compressed fuel capsule, that yielded 3.15 MJ of nuclear energy [1], the NIF laser delivered a high-precision pulse shape with 2.05 MJ of ultra-violet (UV) laser energy and a peak power of 440 TW. This laser energy was an increase of ~8 % compared to that delivered on the previous “threshold of ignition” record yield experiment (1.37 MJ of yield for 1.89 MJ of laser energy) on August 8th, 2021. Here we explain how the results of our extensive research in laser technology and UV optics damage mitigation led to major improvements in the NIF laser, enabling this energy increase along with additional accuracy, precision, and power balance enhancements. Furthermore, we will discuss on-going efforts that have enabled operations at 2.2 MJ of UV energy as well as potential new initiatives to push the laser performance –accuracy and delivered energy– to even higher levels in the future as previously demonstrated on a small subset of NIF beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗