Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shape discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Comparative analysis of new crystal and plastic scintillators for fast and thermal neutron detection

This paper considers scintillation and physical properties of efficient organic scintillators tested as single crystals and as components of plastics with pulse shape discrimination (PSD). For the first time, single crystals of 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) were grown for studies of the basic scintillation properties of this new compound. Comparison to classical organic crystals, like anthracene, trans-stilbene, and p-terphenyl, and to more recently introduced organic glass showed that the new crystal belongs to a group of the most efficient scintillators, with light output exceeding that of trans-stilbene and PSD comparable to that of p-terphenyl. Furthermore, additional studies were conducted to evaluate scintillation performance and physical properties, like hardness and dye leaching, of plastic scintillators prepared with PhF, organic glass, and liquid diisopropylnaphthalene (DIPN) that were considered as examples for potential replacement of PPO (2,5-diphenyloxazole) in current commercial PSD plastic scintillators. Comparison of the highest performing plastic scintillators prepared with these dyes shows that PhF formulations produced a record light output (LO) increase of 69 % relative to EJ-200. Similar improvements obtained with 6 Li-loaded formulations showed that future development of PSD plastics should not be limited to use of PPO but must involve the search and exploration of new efficient dyes that may lead to discovery of much brighter organic scintillators with improved physical properties required for fast and thermal neutron detection, fast neutron spectroscopy, and antineutrino detection applications.

9,9-dimethyl-2-phenyl-9H-fluorene↗

Organic Scintillator for Real-Time Neutron Dosimetry

We have developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept measurements were taken with 137 Cs and 252 Cf, and corresponding simulations were performed in MCNPX-PoliMi. Despite its small size, the detector is able to discriminate between neutron and gamma-rays via pulse shape discrimination. We simulated the response function of the detector to monoenergetic neutrons in the 100 keV–0 MeV range using MCNPX-PoliMi. The measured unfolded 252 Cf neutron spectrum is in good agreement with the theoretical Watt fission spectrum. We determined the ambient dose equivalent by folding the spectrum with the fluence-to-ambient dose conversion coefficient, with a 1.4% deviation from theory. Some preliminary proton beam experiments were preformed at the Bronowice Cyclotron Center patient treatment facility using a clinically relevant proton pencil beam for brain tumor and craino-spinal treatment directed at a child phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy spectrum and flux of fast neutrons in the atmosphere

The neutron energy spectrum and flux in the atmosphere at the Pfotzer maximum (about 100 g per cm squared) were measured at geomagnetic latitude 42 deg N, using a system capable of detecting a small flux of fast (5 to 20 MeV) neutrons in a much larger background flux of gamma rays and charged particles. The detector consisted of a cylindrical cell of organic liquid scintillator coupled to a high-resolution two-parameter multiparticle pulse shape discriminator with a two-parameter logarithmic pulse-height analyzer. The spectral parameter for the differential neutron energy spectrum was found to decrease from 4.4 plus or minus 0.8 between 3.5 and 6.0 MeV to 1.5 plus or minus 1.0 in the interval 11 to 20 MeV; a value of 0.36 plus or minus 0.10 neutrons per cm squared was calculated for neutron flux between 3.5 and 10 MeV. The importance of these results for evaluating the role of albedo neutron leakage as a source of the energetic proton flux in the radiation belts is also considered.

Saint Onge, R. N.↗

Real-Time Wavelength Discrimination for Improved Neutron Discrimination in CLYC

We investigated the effects of optical filters on the pulse shape discrimination properties of Cs 2 LiYCl 6 :Ce (CLYC) scintillator crystals. By viewing the scintillation light through various optical filters, we attempted to better distinguish between neutron and gamma ray events in the crystal. We applied commercial interference and colored glass filters in addition to fabricating quantum dot (QD) filters by suspending QDs in plastic films and glass. QD filters ultimately failed because of instability of the QDs with respect to oxidation when exposed to ambient air, and the tendency of the QDs to aggregate in the plastic. Of the commercial filters, the best results were obtained with a bandpass interference filter covering the spectral region containing core-valence luminescence (CVL) light. However, the PSD response of filtered CLYC light was always poorer than the response exhibited by unfiltered light because filters always reduced the amount of light available for signal processing.

36 MATERIALS SCIENCE↗

Development of a bi-solvent liquid scintillator with slow light emission

One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid scintillator chemistry. The development of a potentially suitable future detector liquid with particularly slow light emission is discussed in the present publication. This cocktail is compared with respect to its fundamental characteristics (scintillation efficiency, transparency, and time profile of light emission) with liquid scintillators currently used in large-scale neutrino detectors. In addition, the optimization of the admixture of wavelength shifters for a scintillator with particularly high light emission is presented. Furthermore, the pulse-shape discrimination capabilities of the novel medium was studied using a pulsed particle accelerator driven neutron source. Beyond that, purification methods based on column chromatography and fractional vacuum distillation for the co-solvent DIN (Diisopropylnaphthalene) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Characterization of Nuclear Material at Idaho National Laboratory

A measurement plan and preliminary Monte Carlo simulations are presented for the investigation of well-defined mixed-oxide fuel pins. Measurement analysis including pulse-height distributions and time-dependent cross-correlation functions will be performed separately for neutrons and gamma rays. The utilization of Monte Carlo particle transport codes, specifically MCNP-PoliMi, is discussed in conjunction with the anticipated measurements. Four EJ-309 liquid scintillation detectors with an accurate pulse timing and digital, offline, optimized pulse-shape discrimination method will be used to prove the dependency of pulse-height distributions, cross-correlation functions, and material multiplicities upon fuel pin composition, fuel pin quantity, and detector geometry. The objective of the measurements and simulations is to identify novel methods for describing mixed-oxide fuel samples by relating measured quantities to fuel characteristics such as criticality, mass quantity, and material composition. This research has applications in nuclear safeguards and nonproliferation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Lithium Iodide neutron scintillator with Eu 2 + activation II: Activator zoning and concentration effects in Bridgman-grown crystals

We have previously reported on the formation of Suzuki Phase precipitate particles as a result of the addition of the divalent activator ion Eu 2+ to the monovalent alkali halide host LiI. [Boatner et al. (2017)]. These precipitates form during Bridgman or other melt-growth processes, even at low Eu 2+ concentrations (e.g., 0.1% EuI 2 doping), and scatter the scintillation light reducing the optical transparency of the scintillator and adversely affecting its radiation-detection performance. In our prior work, we developed a two-stage thermal-treatment method for the post-growth removal of the Suzuki Phase particles and the realization of a significant improvement in the optical transparency and associated neutron-detection of LiI:Eu 2+ scintillators. These improvements resulted in neutron-detection performance that is superior to GS-20 glass and that allows for the application of pulse height gamma-ray discrimination over a wide range of gamma ray energies as opposed to pulse shape discrimination. Here in this paper, we apply the two-stage thermal-processing method for the removal of Suzuki phase precipitates and carry out an in-depth study, first, of the neutron scintillator performance versus the Eu 2+ activator-ion-concentration spatial variation as a result of zoning effects during the Bridgman growth of LiI:Eu and, second, of the effects of varying the initial Eu 2+ activator ion concentration prior to crystal growth. The Eu 2+ zoning variation results allow one to identify and select the most efficient location of the scintillation performance in a directionally solidified single-crystal boule. The present study of the initial activator concentration levels shows that there are, in fact, two distinct types of luminescence centers with varying performance properties — one that occurs only at low EuI 2 addition levels (e.g., 0.01 to 0.06 %EuI 2 ) and that is quickly replaced by a second luminescing center with increasing Eu content (e.g., at 0.1% EuI2). The light yield for the luminescing center formed using a Eu activator in LiI is a critical function of the Eu concentration in the range of 0.01 to 0.1 % EuI 2 , and a high light yield of 100,000 photons/neutron is observed at the 0.06 %EuIadditive level prior to thermal processing.

36 MATERIALS SCIENCE↗

Organic Scintillator Detector Response Simulations with DRiFT

Accurate detector modeling is a requirement to design systems in many non-proliferation scenarios; by determining a Detector’s Response Function (DRF) to incident radiation, it is possible characterize measurements of unknown sources. DRiFT is intended to post-process MCNP® output and create realistic detector spectra. Capabilities currently under development include the simulation of semiconductor, gas, and (as is discussed in this work) scintillator detector physics. Energy spectra and pulse shape discrimination (PSD) trends for incident photon and neutron radiation have been reproduced by DRiFT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer

A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5x10{sup 5} s{sup -1} is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-{gamma}) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-{gamma} discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of deconvolution to recover frequency-domain multiplexed detector pulses

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique “tags” by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. In conclusion, a figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual Gamma Neutron Directional Elpasolite Detector

Some applications, particularly in homeland security, require detection of both neutron and gamma radiation. Typically, this is accomplished with a combination of two detectors registering neutrons and gammas separately. We have investigated a new type of neutron/gamma (n/γ) directional detection capability. We explored a new class of scintillator, cerium (Ce)-doped Elpasolites such as Cs2LiYCl6:Ce (CLYC), Cs2LiLaCl6 (CLLC), Cs2LiLaBr6:Ce (CLLB), or Cs2LiYBr6:Ce (CLYB). These materials are capable of providing energy resolution as good as 2.9% at 662 keV (FWHM), which is better than that of NaI:Tl. Because they contain 6Li, Elpasolites can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 GEEn MeV. Thus, very effective pulse height discrimination is possible. In addition, the core-to-valence luminescence (CVL) provides Elpasolites with different temporal responses under gamma and neutron excitation, and, therefore, may be exploited for effective pulse shape discrimination. For instance, the CLLC emission consists of two main components: (1) CVL spanning from 220 nm to 320 nm and (2) Ce emission found in the range of 350 to 500 nm. The former emission is of particular interest because it appears only under gamma excitation. It is also very fast, decaying with a 2 ns time constant. The n/γ discrimination capability of Elpasolite detectors may be optimized by tuning the cerium doping content for maximum effect on n/γ pulse shape differences. The resulting Elpasolite detectors have the ability to collect neutron and gamma data simultaneously, with excellent discrimination. Further, an array of four of these Elpasolites detectors will perform directional detection in both the neutron and gamma channels simultaneously.

radiation detectors, neutron detectors, scintillat↗

Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr{sub 3}:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LL18-ML-3rdGenScint-PD3Jg_PM Answers

The project has two major technical objectives: a) Development of plastic scintillators with ultra-fast decays for fast neutron detection and imaging with: Light Output (LO) on the level of best commercial plastics (e.g. EJ-200), and Scintillation decay times <1 ns; b) Development of 6Li-loaded organic scintillators for simultaneous detection of fast and thermal neutrons discriminated from gammaray background with the goal is to achieve large gamma-neutron Pulse Shape Discrimination Figures of Merit (PSD FOM) ~4.5 in crystals and ~3.5 in plastics at the light output range of the thermal capture.

36 MATERIALS SCIENCE↗

Characteristics of cesium iodide for use as a particle discriminator for high energy cosmic rays

The possible use of CsI to discriminate between high energy cosmic ray electrons and interacting protons has been investigated. The pulse-shape properties as a function of ionization density, temperature, and spectral response are presented for thallium-activated CsI and as a function of ionization density for sodium-activated CsI. The results are based on previously published data and on corroborative measurements from the present work. Experimental results on the response of CsI to electron-induced electromagnetic cascades and to interacting hadrons are described. Bibliographies of publications dealing with the properties of CsI and with pulse-shape discrimination techniques are presented.

Crannell, C. J.↗

C$^{7}$LYC: A New Scintillator for Fast Neutron Spectroscopy

The scintillator Cs 2 LiYCl 6 (CLYC) has emerged as a versatile detector for both gammas and neutrons, with excellent pulse shape discrimination. Originally developed as a thermal neutron counter, the discovery of its unexpected and unprecedented ~10% pulse height resolution for fast neutrons in the few MeV range has prompted studies to benchmark its use in low-energy nuclear science and applications. Since the typical long time-of-flight arms are not needed for achieving good energy resolution, geometrical efficiency can be enhanced by positioning the detectors much closer to the target. We have constructed a 16-element array of 1” × 1”7Li-enriched C 7 LYC, to eliminate the dominant peak in the spectrum from thermal neutron capture on 6Li, leaving the energy region above 3 MeV with a clean baseline for fast neutron spectroscopy. We have also procured the first ever 3” × 3” C 7 LYC crystal. Test experiments under way with C 7 LYC include elastic and inelastic neutron scattering cross sections at Los Alamos with a pulsed white neutron source, efficiency measurements using mono-energetic neutron beams up to a few MeV at UMass Lowell, and fission neutron measurements with GRETINA and CHICO detector arrays at Argonne. Beta-delayed neutron spectroscopy experiments have also been initiated at the CARIBU and NSCL facilities, to evaluate C 7 LYC as a possible candidate for auxiliary scintillator arrays for stopped beam physics at the next generation rare isotope accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the Density of Different Materials by Using the Collimated Fast Neutron Beam

It was demonstrated in the previous work that various threat materials could be detected inside the sea going cargo container by measuring the three variables, carbon and oxygen concentration and density of investigated material. Density was determined by measuring transmitted neutrons, which is not always practical in terms of setting up the instrument geometry. In order to enable more geometry flexibility, we have investigated the possibility of using the scattered neutrons in cargo material identification. For that purpose, the densities of different materials were measured depending on the position of neutron detectors and neutron generator with respect to the target position. One neutron detector was put above the target, one behind and one in front of the target, above the neutron generator. It was shown that all three positions of neutron detectors can be successfully used to measure the target density, but only if the detected neutrons are successfully discriminated from the gamma rays. Although the associated alpha particle technique/associate particle imaging (API) was used to discriminate the neutrons from the gamma rays, it is believed that the same results would be obtained by using the pulse shape discrimination method. In that way API technique can be avoided and the neutron generator which produces much higher beam intensity than 10{sup 8} n/s can be used. (authors)

36 MATERIALS SCIENCE↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗