Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Intelligent Partitioning based Fully Parallel AC Security-Constrained Optimal Power Flow

Today’s power grid is becoming more diverse and integrated with high-level distributed energy resources and smart control technologies that is creating a new set of grid management challenges in terms of large-scale, nonlinear, and non-convex problem modeling, complex and time-consuming computation, as well as difficult uncertainty handling. This project focused on solving a challenging multi-period security-constrained generation scheduling problem, which is of great importance for maximizing the social welfare of real-time dispatch, day-ahead market, as well as weekly planning of power systems. Our developed software explored parallel optimization algorithms for complex and realistic power system models, and develop fast, efficient, and robust grid optimization solutions on the high-performance computing platform that will enable increased grid economics, flexibility, resilience, as well as energy security in the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable PETSc Implementation of the Three-Phase Unbalanced AC Power Flow Solver

A revolutionary transition of energy infrastructure, spanning across supply and demand sectors, is happening all around the world. Integration of renewable energy sources into our ever-complex power distribution networks is central to the infrastructure planning of the future. One step towards achieving this goal is to solve unbalanced transmission and distribution systems. Traditional approaches and software tools are not suitable because they assume a completely balanced 3-phase system, hence a single-phase equivalent can be solved. Renewable energy such as wind and solar power are intermittent and can pose a challenge when integrating into an already unbalanced power grid. Furthermore, these power grids can be quite large at scale consisting of potentially thousands of buses, which can be computationally demanding. This poster presents preliminary work on designing a robust and scalable 3-phase unbalanced AC power flow solver. The proposed power flow solver will eventually be built on top of the PETSc library and utilizes state-of-the-art parallel data structures like the DMNetwork as well as iterative solvers and preconditioners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Strengthening the SDP Relaxation of AC Power Flows with Convex Envelopes, Bound Tightening, and Valid Inequalities

Here this work revisits the Semidefine Programming (SDP) relaxation of the AC power flow equations in light of recent results illustrating the benefits of bounds propagation, valid inequalities, and the Convex Quadratic (QC) relaxation. By integrating all of these results into the SDP model a new hybrid relaxation is proposed, which combines the benefits from all of these recent works. This strengthened SDP formulation is evaluated on 71 AC Optimal Power Flow test cases from the NESTA archive and is shown to have an optimality gap of less than 1% on 63 cases. This new hybrid relaxation closes 50% of the open cases considered, leaving only 8 for future investigation.

42 ENGINEERING↗

Inexact convex relaxations for AC optimal power flow: Towards AC feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. Here, this paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 test cases. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear power flow control applications to conventional generator swing equations subject to variable generation.

In this paper, the swing equations for renewable generators are formulated as a natural Hamiltonian system with externally applied non-conservative forces. A two-step process referred to as Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) is used to analyze and design feedback controllers for the renewable generator system. This formulation extends previous results on the analytical verification of the Potential Energy Boundary Surface (PEBS) method to nonlinear control analysis and design and justifies the decomposition of the system into conservative and non-conservative systems to enable a two-step, serial analysis and design procedure. In particular, this approach extends the work done by developing a formulation which applies to a larger set of Hamiltonian Systems that has Nearly Hamiltonian Systems as a subset. The results of this research include the determination of the required performance of a proposed Flexible AC Transmission System (FACTS)/storage device to enable the maximum power output of a wind turbine while meeting the power system constraints on frequency and phase. The FACTS/storage device is required to operate as both a generator and load (energy storage) on the power system in this design. The Second Law of Thermodynamics is applied to the power flow equations to determine the stability boundaries (limit cycles) of the renewable generator system and enable design of feedback controllers that meet stability requirements while maximizing the power generation and flow to the load. Necessary and sufficient conditions for stability of renewable generators systems are determined based on the concepts of Hamiltonian systems, power flow, exergy (the maximum work that can be extracted from an energy flow) rate, and entropy rate.

17 WIND ENERGY↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Flow simulation and analysis of high-power flow batteries

The cost of a flow battery system can be reduced by increasing its power density and thereby reducing its stack area. If per-pass utilizations are held constant, higher battery power densities can only be achieved using higher flow rates. Here, a 3D computational fluid dynamics model of a flow battery flow field and electrode is used to analyze the implications of increasing flow rates to high power density operating conditions. Interdigitated and serpentine designs, and cell sizes ranging from 10 cm 2 to 400 cm 2 , are simulated. The results quantify the dependence of pressure loss on cell size and design, demonstrating that the details of the passages that distribute flow between individual channels and the inlet and outlet have a major impact on pressure losses in larger cells. Additionally, in-cell flow behavior is analyzed as a function of cell size and design. Flow structures are interrogated to show how and where electrode parameters influence pressure drops, and how regions where transport is slow are correlated with the presence of experimentally observed cell degradation.

25 ENERGY STORAGE↗

Comparing Power Flow Approximations for Electricity Infrastructure Capacity Expansion Models with High Spatial Resolution

Future electricity system portfolios will require strategic transmission expansions for economically integrating regionally dependent, high-quality renewable resources. In this context, accurate representation of transmission flows in large-scale electricity infrastructure capacity expansion planning problems is important. This paper describes an approximate linearized power flow transmission modeling method for such expansion problems and demonstrates the impact on planning solutions using the National Renewable Energy Laboratory's Regional Energy Deployment System (ReEDS) model. Results are compared against a pipe flow transmission representation, which is used in a number of large-scale planning models. We show that national-scale generation and transmission expansion is not substantially influenced by the power flow methodology but that the pipe flow representation does underestimate required transmission capacity and total system costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Power Dispatch of DGs in Radial and Mesh AC Grids: A Hybrid Solution Methodology between the Salps Swarm Algorithm and Successive Approximation Power Flow Method

In this paper, we address the problem of the optimal power dispatch of Distributed Generators (DGs) in Alternating Current (AC) networks, better known as the Optimal Power Flow (OPF) problem. We used, as the objective function, the minimization of power losses (P loss ) associated with energy transport, which are subject to the set of constraints that compose AC networks in an environment of distributed generation. To validate the effectiveness of the proposed methodology in solving the OPF problem in any network topology, we employed one 10-node mesh test system and three radial text systems: 10, 33, and 69 nodes. In each test system, DGs were allowed to inject 20%, 40%, and 60% of the power supplied by the slack generator in the base case. To solve the OPF problem, we used a master–slave methodology that integrates the optimization method Salps Swarm Algorithm (SSA) and the load flow technique based on the Successive Approximation (SA) method. Moreover, for comparison purposes, we employed some of the algorithms reported in the specialized literature to solve the OPF problem (the continuous genetic algorithm, the particle swarm optimization algorithm, the black hole algorithm, the antlion optimization algorithm, and the Multi-Verse Optimizer algorithm), which were selected because of their excellent results in solving such problems. The results obtained by the proposed solution methodology demonstrate its superiority and convergence capacity in terms of minimization of P loss in both radial and mesh systems. It provided the best reduction in minimum P loss in short processing times and showed excellent repeatability in each test system and scenario under analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Limitations of Fault-Tolerant Quantum Linear System Solvers for Quantum Power Flow

Quantum computers hold promise for solving problems intractable for classical computers, especially those with high time or space complexity. Practical quantum advantage can be said to exist for such problems when the end-to-end time for solving such a problem using a classical algorithm exceeds that required by a quantum algorithm. Reducing the power flow (PF) problem into a linear system of equations allows for the formulation of quantum PF (QPF) algorithms, which are based on solving methods for quantum linear systems such as the Harrow-Hassidim-Lloyd (HHL) algorithm. Speedup from using QPF algorithms is often claimed to be exponential when compared to classical PF solved by state-of-the-art algorithms. Here, we investigate the potential for practical quantum advantage in solving QPF compared to classical methods on gate-based quantum computers. Notably, this paper does not present a new QPF solving algorithm but scrutinizes the end-to-end complexity of the QPF approach, providing a nuanced evaluation of the purported quantum speedup in this problem. Our analysis establishes a best-case bound for the HHL-based quantum power flow complexity, conclusively demonstrating that the HHL-based method has higher runtime complexity compared to the classical algorithm for solving the direct current power flow (DCPF) and fast decoupled load flow (FDLF) problem. Notably, our analysis and conclusions can be extended to any quantum linear system solver with rigorous performance guarantees, based on the known complexity lower bounds for this problem. Additionally, we establish that for potential practical quantum advantage (PQA) to exist it is necessary to consider DCPF-type problems with a very narrow range of condition number values and readout requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Risk-Based Distributionally Robust Optimal Power Flow With Dynamic Line Rating

In this paper, we propose a risk-based data-driven distributionally robust approach to investigating the optimal power flow with dynamic line rating. The risk terms, including penalties for load shedding, wind generation curtailment and line overload, are embedded into the objective function. To robustify the solution, we consider a distributional uncertainty set based on the second-order moment, that captures the correlation between wind generation outputs and line ratings, and also the Wasserstein distance, that hedges against data perturbations. We show that the proposed model can be reformulated as a convex conic program. Approximations of the proposed model are suggested, which leads to a significant reduction of the number of the constraints. For practical large-scale test systems, a distributionally robust optimal power flow model with Wasserstein-distance-based distributional uncertainty set and its convex reformulation are also provided. Simulation results on the 5-bus, the IEEE 118-bus and the Polish 2736-bus test systems validate the effectiveness of the proposed models.

distributionally robust optimization↗

Equivalent Relaxations of Optimal Power Flow

Several convex relaxations of the optimal power flow (OPF) problem have recently been developed using both bus injection models and branch flow models. In this paper, we prove relations among three convex relaxations: a semidefinite relaxation that computes a full matrix, a chordal relaxation based on a chordal extension of the network graph, and a second-order cone relaxation that computes the smallest partial matrix. We prove a bijection between the feasible sets of the OPF in the bus injection model and the branch flow model, establishing the equivalence of these two models and their second-order cone relaxations. Our results imply that, for radial networks, all these relaxations are equivalent and one should always solve the second-order cone relaxation. For mesh networks, the semidefinite relaxation and the chordal relaxation are equally tight and both are strictly tighter than the second-order cone relaxation. Therefore, for mesh networks, one should either solve the chordal relaxation or the SOCP relaxation, trading off tightness and the required computational effort. Simulations are used to illustrate these results.

Bose, S↗

Traveling wave linear accelerator with RF power flow outside of accelerating cavities

A high power RF traveling wave accelerator structure includes a symmetric RF feed, an input matching cell coupled to the symmetric RF feed, a sequence of regular accelerating cavities coupled to the input matching cell at an input beam pipe end of the sequence, one or more waveguides parallel to and coupled to the sequence of regular accelerating cavities, an output matching cell coupled to the sequence of regular accelerating cavities at an output beam pipe end of the sequence, and output waveguide circuit or RF loads coupled to the output matching cell. Each of the regular accelerating cavities has a nose cone that cuts off field propagating into the beam pipe and therefore all power flows in a traveling wave along the structure in the waveguide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chance-Constrained AC Optimal Power Flow for Distribution Systems With Renewables

This paper focuses on distribution systems featuring renewable energy sources (RESs) and energy storage systems, and presents an AC optimal power flow (OPF) approach to optimize system-level performance objectives while coping with uncertainty in both RES generation and loads. The proposed method hinges on a chance-constrained AC OPF formulation where probabilistic constraints are utilized to enforce voltage regulation with prescribed probability. A computationally more affordable convex reformulation is developed by resorting to suitable linear approximations of the AC power-flow equations as well as convex approximations of the chance constraints. The approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive strategy is then obtained by embedding the proposed AC OPF task into a model predictive control framework. Finally, a distributed solver is developed to strategically distribute the solution of the optimization problems across utility and customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mobility power flow analysis of an L-shaped plate structure subjected to distributed loading

An analytical investigation based in the Mobility Power Flow (MPF) method is presented for the determination of the vibrational response and power flow for two coupled flat plate structures in an L-shaped configuration, subjected to distributed excitation. The principle of the MPF method consists of dividing the global structure into a series of subsystems coupled together using mobility functions. Each separate subsystem is analyzed independently to determine the structural mobility functions for the junction and excitation locations. The mobility functions, together with the characteristics of the junction between the subsystems, are then used to determine the response of the global structure and the MPF. In the considered coupled plate structure, MPF expressions are derived for distributed mechanical excitation which is independent of the structure response. However using a similar approach with some modifications excitation by an acoustic plane wave can be considered. Some modifications are required to deal with the latter case are necessary because the forces (acoustic pressure) acting on the structure are dependent on the response of the structure due to the presence of the scattered pressure.

Cuschieri, J. M.↗

Chance Constrained Optimal Power Flow: Risk-Aware Network Control under Uncertainty

When uncontrollable resources fluctuate, Optimum Power Flow (OPF), routinely used by the electric power industry to re-dispatch hourly controllable generation (coal, gas and hydro plants) over control areas of transmission networks, can result in grid instability, and, potentially, cascading outages. This risk arises be cause OPF dispatch is computed without awareness of major uncertainty, in particular fluctuations in renewable output. As a result, grid operation under the OPF with renewable variability can lead to frequent conditions where power line flow ratings are significantly exceeded. Such a condition, which is borne by simulations of real grids, would likely resulting in automatic line tripping to protect lines from thermal stress, a risky and undesirable outcome which compromises stability. Smart grid goals include a commitment to large penetration of highly fluctuating renewables, thus calling to reconsider current practices, in particular the use of standard OPF. Our Chance Constrained (CC) OPF corrects the problem and mitigates dangerous renewable fluctuations with minimal changes in the current operational procedure. Assuming availability of a reliable wind forecast parameterizing the distribution function of the uncertain generation, our CC-OPF satisfies all the constraints with high probability while simultaneously minimizing the cost of economic re-dispatch. CC-OPF allows efficient implementation, e.g. solving a typical instance over the 2746-bus Polish network in 20s on a standard laptop.

Energy Planning, Policy, & Economy(29)↗

Design and Preliminary Experimental Results on a Uniform-Field Test Fixture for Power Flow Experiments

Electrodes that produce a uniform electric field across their surfaces are desired for a variety of high-voltage systems including spark-gap switches and transversely excited atmospheric lasers. Here, the implementation of uniform-field electrodes to a parallel-plate load is described for the study of vacuum power flow under pulsed-power applications. We begin with an overview of general uniform-field geometries, and provide an open-source program that generates these geometries as described by Ernst. Following that, a modification to an existing power-flow experimental platform, that adopts a uniform-field geometry, is introduced and its utility is described. Lastly, preliminary experimental results are presented and future steps are outlined.

Capacitors↗